Effect of natural ageing on volume stability of MSW and wood waste incineration residues

Highlights: ► Natural weathering on BA from MSW and wood waste incineration was evaluated. ► Type of mineral phases, pH and volume stability were considered. ► Weathering reactions effect in improved stability of the materials. - Abstract: This paper presents the results of a study on the effect of natural weathering on volume stability of bottom ash (BA) from municipal solid waste (MSW) and wood waste incineration. BA samples were taken at different steps of treatment (fresh, 4 weeks and 12 weeks aged) and then characterised for their chemical and mineralogical composition and for volume stability by means of the mineralogical test method (M HMVA-StB), which is part of the German quality control system for using aggregates in road construction (TL Gestein-StB 04). Changes of mineralogical composition with the proceeding of the weathering treatment were also monitored by leaching tests. At the end of the 12 weeks of treatment, almost all the considered samples resulted to be usable without restrictions in road construction with reference to the test parameter volume stability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes]

An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it was found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.

36 MATERIALS SCIENCE↗

Heat-Pulse Measurements Reveal Fiber Volume Fractions

Measurements of thermal diffusivities by heat-pulse method constitutes basis of noncontact, nondestructive method of determining fiber volume fractions (FVFs) of samples of composite (matrix/fiber) materials. Modulated radiant heat applied to sample, while resulting modulated infrared emitted is monitored. Phase shift between two modulations indicative of thermal diffusivity and fiber volume fraction of sample. Testing method takes less time, provides data to characterize sample through its thickness, and amenable to scanning for global determination of gradual spatial variations in FVF along sample.

Winfree, William P.↗

Mechanics Methodology for Textile Preform Composite Materials

NASA and its contractors have completed a program to develop a basic mechanics underpinning for textile composites. Three major deliverables were produced by the program: 1. A set of test methods for measuring material properties and design allowables; 2. Mechanics models to predict the effects of the fiber preform architecture and constituent properties on engineering moduli, strength, damage resistance, and fatigue life; and 3. An electronic data base of coupon type test data. This report describes these three deliverables.

Poe, Clarence C., Jr.↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Report Server. This fan can be used for research and development by many organizations. The fan is 3.5 inches in diameter, 9 inches long, and weighed 3.6 lb. The NASA Quiet Space Fan was designed to make 3.64 inches of water pressure rise at 150.3 cfm of airflow at 12,000 rpm at standard air conditions of 70ºF and 14.7 psia. The performance of the metal version of the fan was measured to be 3.48 inches of water at 150.6 cfm at design speed. A low-noise blade-vane count was chosen to try to reduce tone noise generated by this fan by cutting off the first three blade passing frequency tones. In-duct microphone array measurements indicated that the most evident tones occur for frequencies of 1800 Hz (1 BPF) and 7200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This is one way that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems on spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan, noise, ventilation↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Reports Server. This fan can be used for research and development by many organizations. The NASA Quiet Space Fan is 8.89 cm (3.50 in) in diameter, 22.9 cm (9.00 in) long, and the metal fan weighs 1.63 kg (3.6 lbm). The fan was designed to generate a system total pressure rise of 906 Pa (3.64 inches of water) at 0.709 m3/s (150.3 cfm) of airflow at 12,000 rpm (at 21.1ºC (70ºF) and 14.7 psia). Performance measured using standardized techniques showed good agreement with design and predicted values. A low-noise blade-vane count was chosen to reduce tonal noise generated by rotor-stator interaction for the first three blade passing frequency harmonics. In-duct microphone array measurements indicated that the most evident tones occur at frequencies of 1,800 Hz (1 BPF) and 7,200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This demonstrates that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems in spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan↗

Adaptation of the chevron-notch beam fracture toughness method to specimens harvested from diesel particulate filters

In this paper, the apparent fracture toughness of a porous cordierite ceramic was estimated using a large specimen whose geometry was inspired by the ASTM-C1421-standardized chevron-notch beam. In this paper, using the same combination of experiment and analysis used to develop the standardized chevron-notch test for small, monolithic ceramic bend bars, an apparent fracture toughness of 0.6 and 0.9 MPa√m were estimated for an unaged and aged cordierite diesel particulate filter structure, respectively. Finally, the effectiveness and simplicity of this adapted specimen geometry and test method lends itself to the evaluation of (macroscopic) apparent fracture toughness of an entire porous-ceramic, diesel particulate filter structure.

36 MATERIALS SCIENCE↗

A Comparison of Lifting-Line and CFD Methods with Flight Test Data from a Research Puma Helicopter

Four lifting-line methods were compared with flight test data from a research Puma helicopter and the accuracy assessed over a wide range of flight speeds. Hybrid Computational Fluid Dynamics (CFD) methods were also examined for two high-speed conditions. A parallel analytical effort was performed with the lifting-line methods to assess the effects of modeling assumptions and this provided insight into the adequacy of these methods for load predictions.

Bousman, William G.↗

Acousto-ultrasonic measurements to monitor damage during fatigue of composites

An acousto-ultrasonic nondestructive testing method used to monitor damage during static and fatigue loading of thin graphite epoxy laminates is described. The experimental procedure, the signal analysis by the Fast Fourier Transform (FFT) algorithm, and the results of this analysis are discussed. Quasi-static tension tests showed a sharp decrease in the quantitative parameters when transverse cracks developed in the 90 degrees plies of a (0, 90/2/)s laminate. When internal micro-delaminations unite to form macro-delaminations, a sharp decrease in the parameters is also observed. The parameters are found to correlate well with other indications of damage development such as stiffness and degradation. The root mean square value of the moment is found to be more sensitive to damage than stiffness. Various signals and spectrums of graphite epoxy systems are presented.

Govada, A.↗

Corrosion Prevention in Copper Combustion Chamber Liners of Liquid Oxygen/Methane Booster Engines

Prior research conducted by United Technologies Research Center and Rockwell International Rocketdyne Division encountered severe copper corrosion while flowing hydrocarbon fuels through copper cooling tubes. These experimental results have very important implications for the development of low-cost, regeneratively cooled, oxygen/hydrocarbon bipropellant booster engines. Aerojet TechSystems undertook a program sponsored by NASA/Lewis Research Center in 1986 with two objectives: (1) to define the corrosive interaction process that occurs between hydrocarbon fuels and copper combustion chamber liner materials, using both static and dynamic test methods, and (2) to identify and demonstrate protective measures against this corrosive process. The results of the first program task demonstrated that the most damaging corrosive process was caused by trace amounts of sulfur-containing impurities in the hydrocarbon fuel which react with the copper chamber liner material to form cuprous sulfide (Cu2S), as reported in Paper No. AlAA 88-3215. Experiments were conducted which demonstrated this corrosive process with Mil-Spec RP-1, propane, and methane fuels in contact with OFHC, NASA-Z, and ZrCu coppers. The preliminary results of the second program task demonstrated that electrodeposited gold and platinum coatings held promise of preventing corrosion of copper chamber liners by methane contaminated with sulfur-containing impurities, as reported in Paper No. AIAA 89-2738. Experiments were conducted which demonstrated greatly reduced corrosion of copper by hydrogen sulfide (H2S) and methyl mercaptan (CH3SH) as measured impurities in methane. This paper presents the concluding, confirmatory results from the second program task. The efficacy of a protective gold coating on NASA-Z copper cooling channel walls was conclusively demonstrated. Tests were conducted in the Aerojet Carbothermal Test Facility which provide realistic simulations of booster engine cooling channel conditions such as temperature, pressure, flow velocity, and heat flux. Dynamic test series were performed with methane containing 5 and 10 ppm (by volume) hydrogen sulfide. Gold-plated and unplated copper alloy specimens were evaluated. The tests demonstrated that gold coatings were effective in preventing corrosion of the copper. Posttest metallographic examinations of the unplated specimens showed severe corrosion as a result of reaction with the sulfur containing contaminant in the fuel. In contrast, posttest metallographic examination of the gold-coated specimens showed no corrosion under similar operating conditions. The findings from metallurgical and chemical analyses of the copper specimens, chemical analysis of the methane, and description of all test conditions are provided. Conclusions are reached as to the efficacy of the plating methods and the effectiveness of the metal coatings in the prevention of corrosion in hydrocarbon-fueled booster engine combustion chamber liners.

S D Rosenberg↗

In-Situ and Ex-Situ Studies on the Morphology Changes of Polymer Pipeline Materials for Use in Hydrogen Gas Environments

The US natural gas infrastructure is a national asset that could be used to deliver hydrogen and hydrogen blends of natural gas as a pathway to reduce carbon emissions. The distribution system comprises nearly 50% plastic pipe composed of medium- and high-density polyethylene materials (MDPE and HDPE). While these materials perform adequately for natural gas, research on their hydrogen compatibility is essential to understand if any immediate and long-term risks are associated with hydrogen addition. The Blended Gas CRADA, a HyBlend project, has established a comprehensive test method for evaluating MDPE and HDPE of various plastic resin compositions of pipeline material in pure hydrogen and 20% hydrogen/80% methane blends. Both in-situ and ex-situ measurements were performed to capture hydrogen-induced changes in the polyethylene material's crystalline, amorphous and their interphase regions. We investigated MDPE and HDPE pipeline materials made from different polymer resin systems to evaluate the effects of hydrogen gas. The materials were characterized by their density, diffusion coefficient, free volume ratio, and degree of crystallinity. Various advanced characterization methods, including in situ NMR, ex situ XRD, ex situ DSC, and ex situ TDA, were used to analyze the effects of changes in crystalline, amorphous, and interphase regions due to gas exposure. Time-dependent post-decompression quasi-static tensile tests were conducted to explore the effects of gas exposure time on the mechanical behavior of the pipe materials. This work will highlight the time sensitivities during and after gas exposure. The correlation between gas-induced polyethylene morphology changes and the associated material performance will be addressed for the intended applications. These studies will show that polyethylene resin composition and material exposure are important factors when considering whether hydrogen gas affects pipeline materials positively or negatively.

Simmons, Kevin L.↗

Material Testing of PH13-8MO H950 Steel for Xue-Wierzbicki Fracture Criterion Determination

Four tensile coupon designs of PH13-8Mo H950 steel were tested to failure using quasi-static rates to obtain data to calibrate the Xue-Wierzbicki failure model for ductile fracture. The tests recorded the force-displacement, location of the first crack, displacement to fracture, area reduction, and crack propagation path. The test method and coupon designs were adopted from Tomasz Wierzbicki’s “Calibration and evaluation of seven fracture models” report. The XueWierzbicki model predicts fracture based on accumulated equivalent plastic strain, stress triaxiality, and deviatoric state parameter. Calibrating the Xue-Wierzbicki failure model required testing four coupon designs to calculate the four free parameters in the model. The coupon designs tested a range of stress triaxialities with two axisymmetric tests, one shear test, and one plane stress test. The data obtained and presented in this report can be used to develop a Xue-Wierzbicki fracture model for PH13-8Mo H950 steel.

36 MATERIALS SCIENCE↗

Ceramic Composite Experimental Testing Status

Over recent years, ceramic matrix materials such as SiC–SiC and C–C have been gaining interest for use in fusion reactors, light water reactors (LWRs), and high-temperature reactors (HTRs). These materials are good candidates to operate in very high temperature and moderate to high radiation environments. The evaluation of composite materials, in general, is challenging because of variations in precursor materials, variations in the fabrication process across fabricators, and the wide range of potential fiber architectures, to name a few. However, the need to evaluate neutron-irradiated properties adds another layer of complexity, which includes cost, timeline, and specimen size limitations (often associated with irradiation testing). A qualification methodology for the use of ceramic composites is provided in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section III-5-HHB. The methodology is supported by ASTM International (ASTM) guides, which provide a pathway to accomplish this effort. Part of the qualification strategy is for the designer to collect material property data on environmental conditions representative of its design envelope. These data include irradiation effects. This report presents an experimental study and test campaign developed to partially address this gap by providing initial mechanical and physical property data required for design. A variety of different materials using different manufacturing techniques are considered as part of this campaign. The test plan suggests performing a screening or partial irradiation study to assist the designer during the material selection process. The designer can then perform a more comprehensive qualification study if the material performance is promising. This work focuses on the status of the specimen preparations (machining of samples), the current test methods and failure analysis as well as the preparation of irradiation vehicles for the irradiation campaign. The irradiation will be performed at Oak Ridge National Laboratory (ORNL) in the High Flux Isotope Reactor (HFIR) and at Idaho National Laboratory (INL) in the Advanced Test Reactor (ATR).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact Testing of 410 Stainless Steel for Material Impact Model Development

A project is underway to develop a consistent set of material properties, impact test data, and failure analysis for a variety of metallic aircraft materials that can be used to develop improved impact failure and deformation models. This project is jointly funded by the NASA Glenn Research Center and the Federal Aviation Administration William J. Hughes Technical Center. Particular features of this set of data are that all material property and impact test data are obtained using traceable material, the test methods and procedures are extensively documented, and all the raw data are available. Four parallel efforts are currently underway: measurement of material deformation and failure response over a wide range of strain rates and temperatures, failure analysis of material property specimens and impact test articles, development of improved numerical modeling techniques for deformation and failure, and impact testing of flat panels and substructures for model validation. This report describes impact testing performed on 410 stainless steel sheet and plate samples of different thicknesses with two different types of projectiles, one a regular cylinder and one with a more complex geometry incorporating features representative of a jet engine fan blade. Data from this testing will be used in validating material models developed under this program. The material tests and the material models developed in this program will be published in separate reports.

410 Stainless Steel↗

Suggested Modifications for Bifacial Capacity Testing

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of photovoltaic systems. With the increasing deployment of bifacial photovoltaic modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error were inherently higher for the measured capacity of bifacial systems, they could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance—either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2–10-month observation period. Capacity test accuracy could be improved further by using the measured back-of-module temperature and the IEC 61724-2 test method for well curated systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

Degradation of Insulating Glass Units: Thermal Performance, Measurements and Energy Impacts

Insulating glass unit (IGU) degradation has been studied extensively. However, there is limited understanding of how present durability evaluation standards relate to product lifetime. Furthermore, there is debate on how to quantify performance of installed windows over time to better understand degradation processes. More knowledge on these topics is required to link durability evaluation to product lifetime projections based on energy performance. Energy models provide helpful estimations of total annual building energy consumption. However, most models are based on “as installed” performance of envelope components and fail to account for performance degradation. This can lead to an underestimation of building lifetime energy consumption. A better understanding of the relationship between durability and energy performance can inform integration of degradation dynamics into energy modeling software. This will improve lifetime building energy consumption estimations as well as inform appropriate retrofit strategies and timing. This paper reviews current durability literature, various standards for window performance ratings and weathering methods, existing in situ IGU energy performance measurement techniques, and whole-building energy effects. The challenges and disparities among various studies are analyzed and discussed. The authors hope that further work in this area will lead to the development of improved in situ test methods to assess IGU degradation in the field and link this knowledge to improved energy performance modeling approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic testing of a single-degree-of-freedom strapdown gyroscope

Test methods and results are presented for the equivalent average input rate of a single-degree-of-freedom gyroscope operated both open loop and with a ternary-logic pulse-torque-to-balance loop during multiaxis angular oscillation. For the open-loop tests, good agreement was obtained with theoretical results. Two-axis testing was performed for oscillations about the Input-Output axes, the Input-Spin axes, and the Spin-Output axes. These tests run in the torque-to-balance mode revealed significant departures from open-loop results in the induced drift rate. An analysis is developed explaining much of the closed-loop data presented. Test data for the gryoscope in a ternary torque-to-balance loop with constant input rates is presented. The tests demonstrate that the instrument rate linearity does not change with interrogation frequency from 3,600 to 14,400 Hz if the torque coil is tuned to offer a resistive load to the current switch. Analysis cited shows that gyroscope lag compensation eliminates multiple pulsing and other equivalent forms of degraded resolution in a wide variety of quantizing loops. This result is test verified for the ternary delta-modulator loop.

Lory, C. B.↗