Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TAPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

An intelligent Data Delivery Service for and beyond the ATLAS experiment

The intelligent Data Delivery Service (iDDS) has been developed to cope with the huge increase of computing and storage resource usage in the coming LHC data taking. It has been designed to intelligently orchestrate workflows and data management systems, decoupling data pre-processing, delivery, and primary processing in large scale workflows. It is an experiment-agnostic service that has been deployed to serve data carousel (orchestrating efficient processing of tape-resident data), machine learning hyperparameter optimization, active learning, and other complex multi-stage workflows defined via DAG (Directed Acyclic Graph), CWL (Common Workflow Language) and other descriptions, including a growing number of analysis workflows. We will at first introduce some deployed use cases in a summary. Then we will focus on new improvements and use cases under developments in ATLAS, Rubin Observatory and sPHENIX, together with future efforts.

97 MATHEMATICS AND COMPUTING↗

The Structural Characterisation and DFT-Aided Interpretation of Vibrational Spectra for Cyclo(l-Cys-d-Cys) Cyclic Dipeptide in a Solid State

Cyclic dipeptides with two intramolecular peptide bonds forming a six-membered 2,5-diketopiperazine ring are gaining significant attention due to their biological and chemical properties. Small changes in the local geometry of such molecules (from cis to trans) can lead to significant structural differences. This work presents the results of a study of cyclo(l-Cys-d-Cys), a dipeptide comprising two cysteine molecules in opposite chiral configurations, with the functional groups situated at both sides of the diketopiperazine ring. X-ray diffraction (XRD) experiment revealed that the molecule crystallises in the $P$-1 space group, which includes the centre of inversion. The IR and Raman vibrational spectra of the molecule were acquired and interpreted in terms of the potential energy distribution (PED) according to the results of density functional theory (DFT) calculations. The DFT-assisted analysis of energy frameworks for the hydrogen bond network within molecular crystals was performed to support the interpretation of X-ray structural data. The optimisation of the computational model based on three-molecule geometry sections from the crystallographic structure, selected to appropriately reflect the intermolecular interactions responsible for the formation of 1D molecular tapes in cyclo(l-Cys-d-Cys) crystal, allowed for better correspondence between theoretical and experimental vibrational spectra. This work can be considered the first complete structural characterisation of cyclo(l-Cys-d-Cys), complemented via vibrational spectroscopy results with full band assignment aided with the use of the DFT method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Characterization of a Burst Mode 20 Mfps Low Noise CMOS Image Sensor

This paper presents a novel ultra-high speed, high conversion-gain, low noise CMOS image sensor (CIS) based on charge-sweep transfer gates implemented in a standard 180 nm CIS process. Through the optimization of the photodiode geometry and the utilization of charge-sweep transfer gates, the proposed pixels achieve a charge transfer time of less than 10 ns without requiring any process modifications. Moreover, the gate structure significantly reduces the floating diffusion capacitance, resulting in an increased conversion gain of 183 µV/e−. This advancement enables the image sensor to achieve the lowest reported noise of 5.1 e− rms. To demonstrate the effectiveness of both optimizations, a proof-of-concept CMOS image sensor is designed, taped-out and characterized.

47 OTHER INSTRUMENTATION↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Rapid-cycling ReBCO dipole magnet concept for muon acceleration

We present a concept of the rapid-cycling 1.7 T ReBCO magnet for 1 to 10 kT/s ramping range as required for muon acceleration in a future muon collider presently under study. This approach is based on the 6 kA CORC-like cable constructed with 12 superconducting ReBCO tapes of 2 mm width. Based on theoretical prediction there is a linear scaling of the ReBCO cable hysteresis loss with the crossing magnetic field possibly generating power loss independent of the magnetic field ramping speed. This feature makes this ReBCO cable suitable for the construction of rapid-cycling magnets. In this work we outline the design of a dipole magnet for 1.7 T gap magnetic field and discuss the helium coolant parameters for the minimal electric power.

Piekarz, Henryk [Fermilab] (ORCID:0000000194225662↗

BSEC Air Quality: Stationary Aerosol Composition and Mass Concentration at Baltimore

Data is 10-min average mass composition and mass concentration from the TOF-ACSM-X and Aethalometer AE33. TOF-ACSM-X reports fine (less than 2.5 um diameter) non-refractory aerosol, including organic aerosol, sulfate, nitrate, ammonium, and non-refractory chloride. Aethalometer measured the attenuation at different wavelengths for aerosol collected onto tape; one wavelength is used to convert to black carbon mass concentration. Also reported is the elemental ratios determined for organic aerosol (O/C, H/C, and organic matter to organic carbon ratio, OM/OC).

aerosol↗

An Acoustic Quench Detection Method for CICC Conductor Operating in Gas or Liquid

A method using micro-electro-mechanical system (MEMS) acoustic sensor technology to detect a quench and abnormal behavior of a superconductor is discussed. MEMS of microphone chips are installed along the coolant space of a superconducting conductor to monitor the coolant condition. By arranging the acoustic sensor array in a coolant flow channel, it is possible to quickly detect a change in the local condition of the coolant with precise spatial resolution. This method is useful for monitoring superconducting magnets and power cables, especially those made with a cable-in-conduit-conductor (CICC) configuration. The methodology described in this work will also be very useful for a high temperature superconducting (HTS) conductor, such as REBCO tape conductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Passive Gravitational Attitude Control System for Satellites

It is shown how the gravity-gradient effect may be utilized to design a long-lived, earth-pointing satellite attitude control system which requires no fuel supplies, attitude sensors or active control equipment. This two-body system is provided with a magnetic hysteresis damper which effectively damps out oscillations (librations) about the local vertical. The long rods, which must be extended in space from coiled up metal tapes, provide the required large moments of inertia and possess adequate rigidity and sufficient strength to endure the rigors of the extension process. The system is compatible with the requirements of multiple satellite launchings from a single last-stage vehicle. Analysis indicates that the gravitational torques are sufficient to keep the disturbing effects of solar radiation pressure, residual magnetic dipole moments, orbit eccentricity, rod curvature, eddy currents, and meteorite impacts within tolerable limits. It is believed that the high-performance, earth-pointing system described and analyzed in this paper represents an essential step in the development of high-capacity communications satellites requiring long life.

GRAVITY↗

Auxiliary circuit enables automatic monitoring of EKG'S

Auxiliary circuits allow direct, automatic monitoring of electrocardiograms by digital computers. One noiseless square-wave output signal for each trigger pulse from an electrocardiogram preamplifier is produced. The circuit also permits automatic processing of cardiovascular data from analog tapes.

Source record↗

Capacitive system detects and locates fluid leaks

Electronic monitoring system automatically detects and locates minute leaks in seams of large fluid storage tanks and pipelines covered with thermal insulation. The system uses a capacitive tape-sensing element that is adhesively bonded over seams where fluid leaks are likely to occur.

Source record↗

Phonocardiograph system monitors heart sounds

Phonocardiograph system monitors the mechanical activity of the heart in extreme environments. It uses a piezoelectric-crystal microphone with an integral preamplifier, and a signal conditioner having special frequency characteristics. The output signals can be recorded on tape, presented aurally, or transmitted telemetrically to a remote station.

Source record↗

Electronic phase-locked-loop speed control system is stable

Phase locked-loop circuit is used for playback motors in digital tape recorders where the reproducer output remains in exact synchronism with an external reference clock over extended periods. It removes the motor dynamics from the control loop so that the loop is stable without damping.

Stone, F. A.↗

Fixed vacuum plate clamps styrofoam for machining

Aluminum plate holds styrofoam securely in place for machining operations. The styrofoam is clamped to rubber or cork pads on the plate surface by vacuum. Foam rubber tape provides the vacuum seal.

Rauschl, J. A.↗