Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Parameterization of generic positive sequence models to represent behavior of inverter based resources in low short circuit scenarios

The connection of large inverter based resources (IBR) in transmission systems is often located geographically and electrically far away from load centers. This, coupled with the displacement of synchronous machine plants, results in a reduction of the network short circuit strength at the point of connection. Under these conditions, state-of-the-art positive sequence simulation platforms and models can have difficulties maintaining numerical stability and/or providing an accurate representation of IBR plant dynamic behavior. As a result, computationally heavy time domain electromagnetic transient (EMT) simulations may be required to evaluate these systems. In this paper, a recently developed improved generic positive sequence model is parameterized to provide a representation of IBR behavior in low short circuit networks. Further, comparisons against generic and detailed EMT models demonstrate the suitability of the improved positive sequence model to study practical stability issues experienced with presently in-service plants. Such a model can provide some of the accuracy of an EMT representation with a much lower computational burden. The performance of the positive sequence model is validated against the behavior shown by both open white box and closed black box EMT domain models from around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation

Modern power systems are increasingly vulnerable to frequency instability as inverter-based resources (IBRs) replace synchronous machines and reduce system rotational inertia. Existing small-signal frequency stability assessment methods are either computationally intensive, relying on simulation-driven approaches, or lack analytical stability regions that explicitly account for secondary frequency response (SFR). This paper introduces new analytical frameworks that enable evaluation small-signal frequency stability while explicitly incorporating tunable IBR and SFR parameters. Using Kharitonov’s theorem with an overbounding approach, explicit small-signal stability criteria are derived. In addition, based on Białas’ criterion and Hurwitz matrix, analytical stability regions are established to reveal feasible design spaces for SFR and IBR parameters tuning. Extensive Matlab/Simulink-based simulations validate the accuracy and computational efficiency of the proposed methods, demonstrating that coordinated tuning of SFR and IBR parameters can substantially enhance system resilience. By bridging analytical rigor with practical tunability, this work provides an analytical framework for assessing small-signal frequency stability in low-inertia grids, supporting the real-time, scalable, and resilient operation of sustainable power systems.

14 SOLAR ENERGY↗

Temperature evolution on Rh/Al{sub 2}O{sub 3} catalyst during partial oxidation of methane in a reverse flow reactor

Catalytic partial oxidation of methane was investigated in a reverse flow reactor with commercial Rh/Al{sub 2}O{sub 3} catalyst in pellets. The process is carried out in a catalytic fixed bed reactor and switching of feed flow direction is obtained through four electrovalves synchronized in pairs. Temperature profile along the catalyst bed was measured by fast IR thermography and product composition was measured with a continuous gas analyzer. Feed direction switching time, water to methane ratio and inert section length were investigated as process parameters. Data of catalyst bed temperature evolution during the flow cycle are presented, discussed and related to reactor performance as a function of reverse flow switching period. The effect of water addition to the reacting mixture on the dynamics of catalyst bed temperature evolution is also presented. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of high-speed, species-specific chemiluminescence imaging for laminar flame speed and Markstein length measurements in spherically expanding flames

A high-speed chemiluminescence imaging diagnostic system has been developed and characterized for measuring species-specific properties of spherically expanding flames, with the objective of obtaining synchronized measurements of multiple flame properties from a single flame experiment. The imaging system comprises a high-speed camera coupled to a high-speed image intensifier and optical filters to isolate emission from desired excited species. Here this study validates the diagnostic scheme specifically for measuring laminar flame speed and Markstein length from chemiluminescence at three wavelength bands corresponding to OH*, CH*, and total chemiluminescence, respectively. Mixtures of methane-air and methane/ethane-air were tested at initial conditions of atmospheric pressure and room temperature. An under-utilized methodology for computing unburned Markstein length from burned Markstein length was implemented. Flame speed modeling of each mixture was conducted in Chemkin using AramcoMech 2.0. No significant differences were observed between the results derived from the three emission wavelength bands for the flame speeds nor the Markstein lengths. For both of these properties, excellent agreement was observed between the experimental results and the values reported in the literature. Because laminar flame speed and Markstein length show no dependency on the imaging wavelength, the present results imply that multiple flame properties, such as laminar flame speed, Markstein length, flame thickness, and excited-species intensity profiles, can all be acquired simultaneously for the same flame using this method.

42 ENGINEERING↗

Economic analysis of the benefits to petroleum refiners for low carbon boosted spark ignition biofuels

A refinery modeling framework is developed to estimate the benefits of blending high-quality biofuels directly with refinery gasoline components for attaining a premium grade fuel (also termed as Co-Optima Boosted SI gasoline here). Our results change the paradigm of bio-blendstocks (BBs) being competitors to fossil components, by identifying opportunities for refineries to add value to their product slate, from some favorable BB properties. This potential value can be characterized by calculating the breakeven value (BEV), as defined down below. The proposed modeling framework incorporates extensive data from (1) projected product over the next few decades, (2) crude oil and refinery products pricing, and (3) fuel specifications. The complete refinery models serve as a basis for assessing the value of biofuels, assuming profitability remains the same for representative petroleum refinery configurations. Our assessment showed wide range of variation of biofuels BEV from $\$$20-$\$$120/bbl, within the considered blending level and crude prices. Further, the BEV was correlated with the fuel octane ratings such as octane numbers (research, RON and motor octane numbers, MON) and both antiknock index (AKI, average of RON and MON) and sensitivity (S, difference between RON and MON), with a slightly higher correlation with the sensitivity. However, the expected decrease in gasoline demand for the upcoming years could negatively impact biofuels demand and value, in a business-as-usual scenario. Our analysis also showed a more valuable bio-blendstocks incorporation in smaller refineries since they can enhance the capabilities for producing specialty, high-value fuels/products, and introduce high octane-barrels into otherwise constrained blending operations. Additional implications towards refiners include opportunities to rebalance operations, access to high-value fuel markets, and synchronization with broader transportation industry trends. Furthermore, results indicate the value of Co-Optima boosted spark ignition (BSI) efficiency gains can extend to refiners to incentivize decarbonization and diversified feedstock production.

09 BIOMASS FUELS↗

The formation and evolution of the Moon’s crust inferred from the Sm-Nd isotopic systematics of highlands rocks

Ages determined for magnesian and ferroan anorthosite crustal rock suites overlap, suggesting they formed contemporaneously about 4.3–4.5 Ga. A notable exception is the Sm-Nd age previously determined on Mg-suite gabbronorite 67667 which is at least 100 Ma younger than the youngest ferroan anorthosite. New chronologic measurements of 67667 presented here yield concordant Sm-Nd and Rb-Sr mineral isochron ages of 4349 ± 31 Ma and 4368 ± 67 Ma, suggesting the sample is older than previous estimates. Furthermore, a whole rock Sm-Nd isochron of Mg-suite rocks from the Apollo 14, 15, 16, and 17 landing sites yields an age of 4348 ± 25 Ma, indicating that Mg-suite magmatism was widespread and roughly contemporaneous on the lunar nearside. Here, analysis of Sm-Nd internal isochron ages confirms that Mg-suite magmatism was restricted to a period between about 4.33 and 4.35 Ga at the Apollo 14, 15, 16, and 17 landing sites and was synchronous with magmatism at the Apollo 16 site associated with the ferroan anorthosite suite between 4.35 and 4.37 Ga. Magnesian- and ferroan anorthosite suite rocks with ages younger than ~4.33 Ga appear to have experienced slow cooling in the deep lunar interior, so that the ages record when the samples cooled below the closure temperature of the Sm-Nd isotopic system and not the time they crystallized.

79 ASTRONOMY AND ASTROPHYSICS↗

Controls on aggradation and incision in the NE Negev, Israel, since the middle Pleistocene

Here, we investigated the mid-Pleistocene to recent aggradation-incision pattern of two drainage systems (Nahal Peres and Nahal Tahmas) in the hyperarid north eastern Negev desert, southern Israel. Although these drainage systems drain into the tectonically active Dead Sea basin, lake level fluctuations cannot account for the aggradation-incision pattern as bedrock knickpoints disconnect the investigated parts of these drainage systems from base level influence. We applied geomorphic mapping, soil stratigraphy, optically stimulated luminescence (OSL) and cosmogenic (in situ 10 Be) exposure dating to reconstruct cycles of aggradation and incision of alluvial terraces and to study their temporal association with regional periods of humidity and aridity and global glacial-interglacial cycles. The spatial and temporal relationships between the alluvial units suggest changes in the drainage system behavior since the middle Pleistocene, and show a pattern in which prolonged periods of sediment aggradation alternated with short periods of rapid and intense degradation through erosion and incision into sediment and bedrock. We obtain ages for several Pleistocene-Holocene periods of incision: ~ 1.1 Ma, ~ 300 ka, ~ 120 ka, ~ 20 ka, ~ 12 ka and ~ 2 ka. Although broadly synchronous, the Nahal Peres and Nahal Tahmas systems exhibit temporal differences in aggradation and incision.

58 GEOSCIENCES↗

Single Stage PLL-less Decoupled Active and Reactive Power Control for Weak Grid Interactive Inverters

This paper presents a single stage phase locked loop-less (PLL-less) active and reactive power (PQ) control for single-phase weak grid interactive inverters. The absence of the PLL requirement in the proposed PQ control enhances the stability margin comparing to conventional current control approaches in both the stationary or the synchronous reference frame. Additionally, the proposed control scheme enables direct PQ control with a single loop control structure. This paper demonstrates that the proposed PLL-less PQ control scheme is asymptotically stable if the controller gains are positive. The necessary conditions for supplying the rated active power into the weak grid are derived. The provided analysis shows that certain amount of reactive power injection is necessary to avoid point of common coupling (PCC) voltage collapse when the rated active power is injected into the weak grid. Several case studies are provided to demonstrate the performance of the proposed PLL-less PQ control scheme under weak grid condition.

Khan, Ahmad↗

Propagation of non-Gaussian voltage angle fluctuations in high-voltage power grids

Recent measurements have reported non-Gaussian tails in the distribution of frequency data in electric power grids. Large frequency deviations may induce grid instabilities and it is therefore crucial to understand how noise disturbances with long, non-Gaussian tails propagate. Here, we investigate how fluctuations in power feed-in, characterized by non-zero cumulants of their distribution, propagate through high-voltage power grids. Unlike previous investigations which focused on the white-noise limit, we consider the limit of long noise correlation time, where power feed-in fluctuates over times longer than the inherent dynamical time scales of the grid - the relevant regime for large-scale, high-voltage distribution grids. In this work, we show that in this limit, the skewness and kurtosis of the power feed-in distribution propagate similarly as its variance, independently of the distribution of inertia. Non-Gaussianities from individual sources of noise therefore persist throughout the entire network. This finding is corroborated by numerical results on a realistic model of the synchronous grid of continental Europe.

42 ENGINEERING↗

Validation of Phasor-Domain Transmission and Distribution Co-simulation Against Electromagnetic Transient Simulation

The rapid deployment of renewable energy resources has led to the widespread use of power electronics in modern power systems. As these systems transition from being dominated by large synchronous machines to increasingly incorporating inverter-based resources (IBRs), traditional methods are becoming inadequate. Addressing this challenge, this paper introduces a scalable phasor-domain T\&D co-simulation framework based on open-source software. It focuses on the framework's validation against the PSCAD Electromagnetic Transient (EMT) analysis tool. The validation results demonstrate the framework's high-fidelity and a computational time speed-up of 60 to 100 times, marking a pioneering validation effort in T\&D co-simulation research.

Inverter-based resources, co-simulation, Electroma↗

Cause identification of electromagnetic transient events using spatiotemporal feature learning

This paper presents a spatiotemporal feature learning method for cause identification of electromagnetic transient events in power grids. The proposed method is formulated based on the availability of time-synchronized high-frequency measurements and using the convolutional neural network as the spatiotemporal feature representation along with softmax function for the classification. Despite the existing threshold-based, or energy-based events analysis methods, such as support vector machine autoencoder, and tapered multi-layer perceptron neural network, the proposed feature learning is carried out with respect to both time and space. The effectiveness of the proposed feature learning and the subsequent cause identification is validated through the Electromagnetic Transients Program (EMTP) simulation of different events such as line energization, capacitor bank energization, lightning, fault, and high-impedance fault in the IEEE 30-bus, and the real-time digital simulation of the Western System Coordinating Council (WSCC) 9-bus system.

42 ENGINEERING↗

A time-domain electromechanical co-simulation framework for power system transient analysis with retainment of user defined models

This paper proposes a time-domain electromechanical co-simulation framework to accomplish concurrent running of multiple simulators in order to preserve user-defined models and allow maximum simulation accuracy for power system transient analysis. Here, a middleware interface is developed to manage the interaction and synchronization of the multiple simulators via boundary model. Consequently, it eliminates the requirement of model conversion of each subsystem and thus ensure the user-defined models in each specific software are retained for entire system situational awareness. Preliminary testing results on 140-bus Northeastern Power Coordinating Council (NPCC) model validate the effectiveness and accuracy of the proposed framework for PSS/E and PSLF co-simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamically robust coordinated set point tracking of distributed DERs at point of common coupling

Low-inertia operation of small-scale power systems, such as a microgrid or a portion of a long feeder, requires careful coordination of the controller performance of the constituting devices. This challenge is exacerbated in microgrids serving the functionalities of a conventional synchronous-based generation unit while comprised of smaller DERs operating mainly interfaced through power electronics converters. This paper builds on the idea of set point modulation and proposes a two-level control strategy that aims to achieve superior performance at the point of common coupling (PCC) of microgrids by combining a local control level with a distributed and coordinated level. Several case studies on both AC and DC systems, the CIGRE low-voltage benchmark system as the AC system and a test DC microgrid, validate the performance of the proposed approach. The real-world applicability of the approach is established via a high-fidelity power hardware-in-the-loop (PHIL) experimental setup and an application case study on grid frequency regulation. The proposed approach enables a microgrid to participate in ancillary service provisions where speed and quality of regulation are critical.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Grid Strength under Uncertain Renewable Generation

The increasing displacement of synchronous generators with renewable resources such as wind and solar via power electronic interfaces causes a reduction in short-circuit strength and weak grid issues. The variation and uncertainty of renewable energy increase challenges for identifying weak grid conditions. This paper proposes an efficient method to analyze the impact of uncertain renewable energy on grid strength. The proposed method uses the probabilistic collocation method (PCM) to approximate the results of grid strength assessment under uncertain renewable generation, in order to reduce computational burden without compromising result accuracy when compared with traditional Monte Carlo simulation (MCS). To improve the accuracy of the approximation results, the proposed method integrates the K-means clustering technique with PCM to select the approximation samples of input variables. The efficacy of the proposed method is demonstrated by comparison with MCS on the modified IEEE 9-bus system and modified IEEE 39-bus system with multiple renewable generators.

grid strength↗

Specifying angular reference for robust three-phase state estimation

While the phase angle of any of the bus voltages can be chosen as the angular reference in the state estimation formulation of positive sequence networks, the same approach does not readily extend to three-phase network state estimation problem. It is commonly assumed that there is at least one bus where the bus voltages are perfectly balanced with phase angles displaced ±120° and these balanced three phase voltages are used as the three-phase reference in solving the three-phase state estimation problem. This assumption may be quite realistic in transmission networks, and for distribution networks with a strong transmission system connection. However, it might not be realistic to assume existence of a perfectly balanced reference bus in today’s distribution systems with ever increasing penetration of renewable sources or for isolated operation of microgrids. In this paper, a novel state estimation formulation will be presented which facilitates correct solution irrespective of the existence of buses with perfectly balanced voltages. The new formulation is general, and lends itself to bad data processing. It yields accurate results in any three-phase power system irrespective of its operating conditions (balanced or highly unbalanced), configuration (isolated microgrid, connected to transmission system, etc.) and whether or not it contains any synchronous generators. The performance of the method is validated using the IEEE 123 bus three-phase system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.

Noh, Seung-Gil↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phase-field modeling of crack growth and mitigation in solid oxide cells

Fracture and crack growth is one of the main degradation mechanisms in solid oxide cells (SOCs). However, the modeling of crack growth in SOCs is challenging due to their complex microstructures and possible plasticity development within the Ni particles in Ni-based SOC electrodes. In this study, a phase-field fracture model is developed, which incorporates the SOC microstructures and phase-dependent material properties, including yield strength, fracture toughness in the bulk and at the interphase boundaries. The model is employed to study crack initiation and growth under thermal and redox cycling on the hydrogen electrode side of SOCs. The simulation results demonstrate that under thermal cycling, work-zone cracking dominates in electrolyte-supported SOCs with cracks initiated at the triple-phase boundaries, while only minor mechanical degradation occurs in hydrogen-electrode-supported SOCs after hundreds of thermal cycles. Under redox cycling, through-cracking of yttria-stabilized zirconia (YSZ) in the hydrogen electrode and electrolyte layers dominates. Finally, the simulation results suggest several crack-mitigation strategies, including decreasing the porosity in the hydrogen electrode support layer and synchronizing thermal strain to balance oxidation strain.

08 HYDROGEN↗