Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Streaming data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Reducing streak film data via electronic cross correlator

Continuous /nonframing/ motion picture projector, two photocells, a cross-correlator, and a ground glass screen where the photocells intercept the stream image determine the time delay between successive streak images. Velocities corresponding to the streaks are determined from the delay together with the distance separating the photocells.

Dickerson, R. A.↗

Application of optical interferometry in compressible flows

Interferometry methods were applied to the investigation of steady and unsteady flows in large scale transonic wind tunnels. Holographic interferometry was demonstrated to provide reliable flow visualization and quantitative results for a number of two-dimensional flows. These conclusions were based on extensive comparisons with results obtained by other means. Data obtained on a NACA 64A010 airfoil with an oscillating flap installed in the Ames 11-foot transonic tunnel are presented. Interferograms were recorded at a free stream Mach number of 0.8, flap frequency of 30 Hertz and chord Reynolds numbers of 6.6 x 10 to the 6th and 12.3 x 10 to the 6th. The interferometric results were reduced to dynamic surface pressures, Mach contours and wake flow profiles. A new interferometry method that is capable of providing real-time interferometry data is also discussed.

Bachalo, W. D.↗

Analysis of Crossflow Transition Flight Experiment aboard the Pegasus Launch Vehicle

The Pegasus wing-glove flight experiment was designed to provide crossflow transition data at high Mach numbers, specifically to help validate stability based predictions for transition onset in a flight environment. This paper provides an analysis of the flight experiment, with emphasis on computational results for crossflow disturbances and the correlation of disturbance growth factors with in-flight transition locations via the e(sup N) method. Implications of the flight data for attachment line stability are also examined. Analysis of the thermocouple data reveals that transition (from turbulent to laminar flow) was first detected during the ascending flight of the rocket when the free stream Mach number exceeded about 4. Therefore, computations have been performed for flight Mach numbers of 4.13, 4.35, 4.56 and 4.99. Due to continually decreasing unit Reynolds number at higher altitudes, the entire wing-glove boundary layer became laminar at the highest flight Mach number computed above. In contrast, the boundary layer flow over the inboard tile region remained transitional up to and somewhat beyond the time of laminarization over the instrumented glove region. Linear stability predictions confirmed that the tile boundary layer is indeed more unstable to crossflow disturbances than the much colder stainless steel glove boundary layer. The transition locations based on thermocouple data from both the glove and the tile regions are found to correlate with stationary-crossflow N-factors within the range of 7 to 12.4 and with traveling mode N-factors between 7.6 and 14.1. Data from the thermocouples and hot film sensors indicates that transition from turbulent to laminar flow (i.e., laminarization) at a fixed point over the glove is generally completed within a flight time interval of 3 seconds. However, the times at which transition begins and ends as inferred from the hot film sensors are found to differ by about 2 seconds from the corresponding estimates based on the thermocouple data.

Malik, Mujeeb R.↗

The Calculated and Measured Performance Characteristics of a Heated-Wire Liquid-Water-Content Meter for Measuring Icing Severity

Ground tests have been made of an instrument which, when assembled in a more compact form for flight installation, could be used to obtain statistical flight data on the liquid-water content of icing clouds and to provide an indication of icing severity. The sensing element of the instrument consists of an electrically heated wire which is mounted in the air stream. The degree of cooling of the wire resulting from evaporation of the impinging water droplets is a measure. of the liquid-water content of the cloud. Determination of the value of the liquid-water content from the wire temperature at any instant requires a knowledge of the airspeed, altitude, and air temperature. An analysis was made of the temperature response of a heated wire exposed to an air stream containing water drops. Comparisons were made of the liquid-water content as measured with several heated wires and absorbent cylinders in an artificially produced cloud. For one of the wires, comparative tests were made with a rotating-disk icing-rate meter in an icing wind tunnel. From the test results, it was shown that an instrument for measuring the concentration of liquid water in an air stream can be built using an electrically heated wire of known temperatureresistance characteristics, and that the performance of such a device can be predicted using appropriate theory. Although an instrument in a form suitable for gathering statistical data in flight was not built, the practicability of constructing such an instrument was illustrated. The ground-test results indicated that a flight heated-wire instrument would be simple and durable, would respond rapidly to variations in liquid-water content, and could be used for the measurement of water content in clouds which are above freezing temperature, as well as in icing clouds.

Neel, Carr B.↗

Aeroheating Testing and Predictions for Project Orion CEV at Turbulent Conditions

An investigation of the aeroheating environment of the Project Orion Crew Exploration Vehicle was performed in the Arnold Engineering Development Center Hypervelocity Wind Tunnel No. 9 Mach 8 and Mach 10 nozzles and in the NASA Langley Research Center 20 - Inch Mach 6 Air Tunnel. Heating data were obtained using a thermocouple-instrumented approx.0.035-scale model (0.1778-m/7-inch diameter) of the flight vehicle. Runs were performed in the Tunnel 9 Mach 10 nozzle at free stream unit Reynolds numbers of 1x10(exp 6)/ft to 20x10(exp 6)/ft, in the Tunnel 9 Mach 8 nozzle at free stream unit Reynolds numbers of 8 x 10(exp 6)/ft to 48x10(exp 6)/ft, and in the 20-Inch Mach 6 Air Tunnel at free stream unit Reynolds numbers of 1x10(exp 6)/ft to 7x10(exp 6)/ft. In both facilities, enthalpy levels were low and the test gas (N2 in Tunnel 9 and air in the 20-Inch Mach 6) behaved as a perfect-gas. These test conditions produced laminar, transitional and turbulent data in the Tunnel 9 Mach 10 nozzle, transitional and turbulent data in the Tunnel 9 Mach 8 nozzle, and laminar and transitional data in the 20- Inch Mach 6 Air Tunnel. Laminar and turbulent predictions were generated for all wind tunnel test conditions and comparisons were performed with the experimental data to help define the accuracy of computational method. In general, it was found that both laminar data and predictions, and turbulent data and predictions, agreed to within less than the estimated 12% experimental uncertainty estimate. Laminar heating distributions from all three data sets were shown to correlate well and demonstrated Reynolds numbers independence when expressed in terms of the Stanton number based on adiabatic wall-recovery enthalpy. Transition onset locations on the leeside centerline were determined from the data and correlated in terms of boundary-layer parameters. Finally turbulent heating augmentation ratios were determined for several body-point locations and correlated in terms of the boundary-layer momentum Reynolds number.

Hollis, Brian R.↗

Aeroheating Test of CEV Entry Vehicle at Turbulent Conditions

An investigation of the aeroheating environment of the Project Orion Crew Entry Vehicle has been performed in the Arnold Engineering Development Center Tunnel 9. Data were measured on a approx. 3.5% scale model (0.1778m/7-inch diam.) of the vehicle using coaxial thermocouples in the Mach 8 and Mach 10 nozzles of Tunnel 9. Runs were performed at free stream Reynolds numbers of 1 106/ft to 20 10(exp 6)/ft in the Mach 10 nozzle and 8 10(exp 6)/ft to 48 10(exp 6)/ft in the Mach 8 nozzle. The test gas in Tunnel 9 is pure N2, which at these operating conditions remains un-dissociated and may be treated as a perfect gas. At these conditions, laminar, transitional, and turbulent flow was produced on the model at Mach 10, and transitional and turbulent conditions were produced on the model at Mach 8. The majority of runs were made on a clean, smooth-surface model configuration and a limited number of runs were made in which inserts with varying boundary-layer trips configurations were used to force the occurrence of transition. Laminar and turbulent predictions were generated for all wind tunnel test conditions and comparisons were performed with the data for the purpose of helping to define uncertainty margins for the computational method. Data from both the wind tunnel test and the computations are presented herein. Figure 1 shows a schematic of the thermocouple locations on the model and figures 2 and 3 show a photo and schematic of the AEDC Hypervelocity Tunnel 9. Figure 4 shows a typical grid used in the computations. From the comparisons shown in figures 5 through 8 it was concluded that for perfect-gas conditions, the computations could predict either fully-laminar or full-turbulent flow to within +/-10% of the experimental data. The experimental data showed that transition began on the leeside of the heatshield at a free stream Reynolds number of 9 10(exp 6)/ft in the Mach 10 nozzle and fully-developed turbulent flow was produced at 20 10(exp 6)/ft. In the Mach 8 nozzle, transition on the leeside of the heat-shield was observed for all test conditions, and full-developed turbulent flow occurred at a free stream Reynolds number of 18 10(exp 6)/ft. On the aftbody of the vehicle no evidence of turbulence was detected at Mach 10 conditions, and at Mach 8 conditions, transition appeared to begin on the windside of the aftbody at free stream Reynolds number of 18x10(exp 6)/ft with fully-developed turbulent flow occurring only at the highest test condition of 48x10(exp 6)/ft.

Hollis, Brian R.↗

Comparison of measured and modeled radiation, heat and water vapor fluxes: FIFE pilot study

The feasibility of using radio frequency receivers to collect data from automated weather stations to model fluxes of latent heat, sensible heat, and radiation using routine weather data collected by automated weather stations was tested and the estimated fluxes were compared with fluxes measured over wheat. The model Cupid was used to model the fluxes. Two or more automated weather stations, interrogated by radio frequency and other means, were utilized to examine some of the climatic variability of the First ISLSCP (International Satellite Land-Surface Climatology Project) Field Experiment (FIFE) site, to measure and model reflected and emitted radiation streams from various locations at the site and to compare modeled latent and sensible heat fluxes with measured values. Some bidirectional reflected and emitted radiation data were collected from 23 locations throughout the FIFE site. Analysis of these data along with analysis of the measured sensible and latent heat fluxes is just beginning.

Blad, Blaine L.↗

Ice-Borehole Probe

An instrumentation system has been developed for studying interactions between a glacier or ice sheet and the underlying rock and/or soil. Prior borehole imaging systems have been used in well-drilling and mineral-exploration applications and for studying relatively thin valley glaciers, but have not been used for studying thick ice sheets like those of Antarctica. The system includes a cylindrical imaging probe that is lowered into a hole that has been bored through the ice to the ice/bedrock interface by use of an established hot-water-jet technique. The images acquired by the cameras yield information on the movement of the ice relative to the bedrock and on visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At the time of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-data-transmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At the time of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-datatransmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the visible features of the lower structure of the ice sheet, including ice layers formed at different times, bubbles, and mineralogical inclusions. At thime of reporting the information for this article, the system was just deployed in two boreholes on the Amery ice shelf in East Antarctica and after successful 2000 2001 deployments in 4 boreholes at Ice Stream C, West Antarctica, and in 2002 at Black Rapids Glacier, Alaska. The probe is designed to operate at temperatures from 40 to +40 C and to withstand the cold, wet, high-pressure [130-atm (13.20-MPa)] environment at the bottom of a water-filled borehole in ice as deep as 1.6 km. A current version is being outfitted to service 2.4-km-deep boreholes at the Rutford Ice Stream in West Antarctica. The probe (see figure) contains a sidelooking charge-coupled-device (CCD) camera that generates both a real-time analog video signal and a sequence of still-image data, and contains a digital videotape recorder. The probe also contains a downward-looking CCD analog video camera, plus halogen lamps to illuminate the fields of view of both cameras. The analog video outputs of the cameras are converted to optical signals that are transmitted to a surface station via optical fibers in a cable. Electric power is supplied to the probe through wires in the cable at a potential of 170 VDC. A DC-to-DC converter steps the supply down to 12 VDC for the lights, cameras, and image-datatransmission circuitry. Heat generated by dissipation of electric power in the probe is removed simply by conduction through the probe housing to the adjacent water and ice.

Behar, Alberto↗

Analytical and Experimental Evaluation of the Heat Transfer Distribution over the Surfaces of Turbine Vanes

Three airfoil data sets were selected for use in evaluating currently available analytical models for predicting airfoil surface heat transfer distributions in a 2-D flow field. Two additional airfoils, representative of highly loaded, low solidity airfoils currently being designed, were selected for cascade testing at simulated engine conditions. Some 2-D analytical methods were examined and a version of the STAN5 boundary layer code was chosen for modification. The final form of the method utilized a time dependent, transonic inviscid cascade code coupled to a modified version of the STAN5 boundary layer code featuring zero order turbulence modeling. The boundary layer code is structured to accommodate a full spectrum of empirical correlations addressing the coupled influences of pressure gradient, airfoil curvature, and free-stream turbulence on airfoil surface heat transfer distribution and boundary layer transitional behavior. Comparison of pedictions made with the model to the data base indicates a significant improvement in predictive capability.

Hylton, L. D.↗

Analysis of the 2019 Midwest US Flooding Using NASA Data

In the wake of Winter Storm Ulmer, an intense "bomb cyclone" that set preliminary low-pressure records, historic flooding occurred in 41 locations across the Midwest United States, causing many streams and rivers - including the Platte, Missouri, and Elkhorn Rivers - to rise to all-time record flood levels in Nebraska. Warm and dry conditions, along with 4-8 inches of snowfall, and over 1" of rain caused over 3-5" of storm water runoff from rapid melting.A rare confluence of circumstances produced the flooding, including extreme cold earlier in the winter that preserved a significant amount of snowfall, a thick layer of ice on waterways, and the large downpour of rain from Winter Storm Ulmer. Unusually warm air caused the snow and ice to rapidly melt, producing record amounts of runoff within a short period of time. This poster presents several data sets from NASA and the USGS (our partner agency) that can be used in analyzing floods and flood areas, including soil moisture, snowfall, floodwater areas, vicinity of urban areas and impervious surfaces, and proximity of strategic or critical infrastructure.

DAAC↗

Sea level differences across the Gulf Stream and Kuroshio extension

The sea level differences between the Sargasso Sea and the slope waters across the Gulf Stream region, averaged between 73 and 61 deg W, and the comparable areas across the Kuroshio extension region, averaged between 143 and 156 deg E, were estimated using the Geosat altimeter data obtained between November 1986 and December 1988. The sea-level differences between the two regions showed a strong correlation between the northwest Atlantic and Pacific, dominated by annual cycles that peak in late-September to mid-October, with about 9 cm (the Gulf Stream region) and about 6.9 cm (Kuroshio region) amplitudes.

Zlotnicki, Victor↗

Steady and unsteady transonic flow

An investigation of the transonic flow over a circular arc airfoil was conducted to obtain basic information for turbulence modeling of shock-induced separated flows and to verify numerical computer codes which are being developed to simulate such flows. The investigation included the employment of a laser velocimeter to obtain data concerning the mean velocity, the shear stress, and the turbulent kinetic energy profiles in the flowfield downstream of the airfoil midchord where the flow features are more complex. Depending on the free-stream Mach number, the flowfield developed was either steady with shock-wave-induced separation extending from the foot of the shock wave to beyond the trailing edge or unsteady with a periodic motion also undergoing shock-induced separation. The experimental data were compared with the results of numerical simulations in which a computer code was employed that solved the time-dependent Reynolds' averaged compressible Navier-Stokes equations.

Seegmiller, H. L.↗

Do Coronal Holes Cause 27 Day Recurring Geomagnetic Storms?

We examine 3 years of interplanetary data and geomagnetic activity indices (1973-1975) to determine the causes of geomagnetic storms and substorms during the descending phase of the solar cycle. In this paper, we specifically studied the year 1974 where two long lasting coronating streams existed.

geomagnetic storms geomagnetic activity interplane↗

Jet Stream Analysis and Forecast Errors Using GADS Aircraft Observations in the DAO, ECMWF, and NCEP Models

We have utilized an extensive set of independent British Airways flight data recording wind vector and temperature observations (the Global Aircraft Data Set [GADS] archive) in three ways: (a) as an independent check of operational analyses; (b) as an analysis observing system experiment (OSE) as if the GADS observations were available in real time; and (c) as the corresponding forecast simulation experiment applicable to future operational forecasts. Using a 31 day sample (0000 UTC 20 December 2000 through 0000 UTC 20 January 2000) from Winter 2000, we conclude that over the data-dense continental U. S. analyzed jet streaks are too weak by -2% to -5%. Over nearby data-sparse regions of Canada, analyzed jet streaks are too weak by -5% to -9%. The second range provides a limit on the accuracy of current jet streak analyses over the portions of the -85% of the earth's surface that are poorly covered by non-satellite observations. The -5% to -9% range is relevant for the pre-third generation satellite (AIRS, IASI, GIFTS) era.

Cardinali, Carla↗

Methods and Apparatus for Aggregation of Multiple Pulse Code Modulation Channels into a Signal Time Division Multiplexing Stream

Methods and apparatus are provided for telemetry processing using a telemetry processor. The telemetry processor can include a plurality of communications interfaces, a computer processor, and data storage. The telemetry processor can buffer sensor data by: receiving a frame of sensor data using a first communications interface and clock data using a second communications interface, receiving an end of frame signal using a third communications interface, and storing the received frame of sensor data in the data storage. After buffering the sensor data, the telemetry processor can generate an encapsulated data packet including a single encapsulated data packet header, the buffered sensor data, and identifiers identifying telemetry devices that provided the sensor data. A format of the encapsulated data packet can comply with a Consultative Committee for Space Data Systems (CCSDS) standard. The telemetry processor can send the encapsulated data packet using a fourth and a fifth communications interfaces.

Chang, Chen J.↗

Electronic research and technology requirements for marine resources

The Woods Hole air/space oceanographic program for 1969 is discussed. Studies included: (1) monitoring the sharp temperature boundary of the Gulf Stream by microwave and infrared observation, (2) spectrophotometry of the Gulf Stream and the adjacent continental slope and shelf water over Georges Bank, (3) interpretation of cloud and other meteorological data in terms of the effects of wind and sun on the upper ocean, (4) a sea state test plan, (5) systems research, and (6) ocean data recovery by aircraft and satellite.

Ewing, G. C.↗

Boundary layer integral matrix procedure code modifications and verifications

A summary of modifications to Aerotherm's Boundary Layer Integral Matrix Procedure (BLIMP) code is presented. These modifications represent a preliminary effort to make BLIMP compatible with other JANNAF codes and to adjust the code for specific application to rocket nozzle flows. Results of the initial verification of the code for prediction of rocket nozzle type flows are discussed. For those cases in which measured free stream flow conditions were used as input to the code, the boundary layer predictions and measurements are in excellent agreement. In two cases, with free stream flow conditions calculated by another JANNAF code (TDK) for use as input to BLIMP, the predictions and the data were in fair agreement for one case and in poor agreement for the other case. The poor agreement is believed to result from failure of the turbulent model in BLIMP to account for laminarization of a turbulent flow. Recommendations for further code modifications and improvements are also presented.

Evans, R. M.↗

Evaluation of viscous drag reduction schemes for subsonic transports

The results are described of a theoretical study of viscous drag reduction schemes for potential application to the fuselage of a long-haul subsonic transport aircraft. The schemes which were examined included tangential slot injection on the fuselage and various synergetic combinations of tangential slot injection and distributed suction applied to wing and fuselage surfaces. Both passive and mechanical (utilizing turbo-machinery) systems were examined. Overall performance of the selected systems was determined at a fixed subsonic cruise condition corresponding to a flight Mach number of free stream M = 0.8 and an altitude of 11,000 m. The nominal aircraft to which most of the performance data was referenced was a wide-body transport of the Boeing 747 category. Some of the performance results obtained with wing suction are referenced to a Lockheed C-141 Star Lifter wing section. Alternate designs investigated involved combinations of boundary layer suction on the wing surfaces and injection on the fuselage, and suction and injection combinations applied to the fuselage only.

Marino, A.↗