Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLICING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy

Purpose: Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of “true” information due to greater reliance on a priori information. Methods: Lung tumor motion trajectories in the superior–inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. Results: In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3–0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. Conclusions: The authors’ initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.

60 APPLIED LIFE SCIENCES↗

Correlation of FMISO simulations with pimonidazole-stained tumor xenografts: A question of O{sub 2} consumption?

Purpose: To compare a dedicated simulation model for hypoxia PET against tumor microsections stained for different parameters of the tumor microenvironment. The model can readily be adapted to a variety of conditions, such as different human head and neck squamous cell carcinoma (HNSCC) xenograft tumors. Methods: Nine different HNSCC tumor models were transplanted subcutaneously into nude mice. Tumors were excised and immunoflourescently labeled with pimonidazole, Hoechst 33342, and CD31, providing information on hypoxia, perfusion, and vessel distribution, respectively. Hoechst and CD31 images were used to generate maps of perfused blood vessels on which tissue oxygenation and the accumulation of the hypoxia tracer FMISO were mathematically simulated. The model includes a Michaelis–Menten relation to describe the oxygen consumption inside tissue. The maximum oxygen consumption rate M{sub 0} was chosen as the parameter for a tumor-specific optimization as it strongly influences tracer distribution. M{sub 0} was optimized on each tumor slice to reach optimum correlations between FMISO concentration 4 h postinjection and pimonidazole staining intensity. Results: After optimization, high pixel-based correlations up to R{sup 2} = 0.85 were found for individual tissue sections. Experimental pimonidazole images and FMISO simulations showed good visual agreement, confirming the validity of the approach. Median correlations per tumor model varied significantly (p < 0.05), with R{sup 2} ranging from 0.20 to 0.54. The optimum maximum oxygen consumption rate M{sub 0} differed significantly (p < 0.05) between tumor models, ranging from 2.4 to 5.2 mm Hg/s. Conclusions: It is feasible to simulate FMISO distributions that match the pimonidazole retention patterns observed in vivo. Good agreement was obtained for multiple tumor models by optimizing the oxygen consumption rate, M{sub 0}, whose optimum value differed significantly between tumor models.

60 APPLIED LIFE SCIENCES↗

Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment

Purpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. Methods: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisition with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. Results: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. Conclusions: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-06: Automatic Brain Tumor Segmentation for Stereotactic Radiosurgery Applications

Purpose: Stereotactic radiosurgery (SRS), which delivers a potent dose of highly conformal radiation to the target in a single fraction, requires accurate tumor delineation for treatment planning. We present an automatic segmentation strategy, that synergizes intensity histogram thresholding, super-voxel clustering, and level-set based contour evolving methods to efficiently and accurately delineate SRS brain tumors on contrast-enhance T1-weighted (T1c) Magnetic Resonance Images (MRI). Methods: The developed auto-segmentation strategy consists of three major steps. Firstly, tumor sites are localized through 2D slice intensity histogram scanning. Then, super voxels are obtained through clustering the corresponding voxels in 3D with reference to the similarity metrics composited from spatial distance and intensity difference. The combination of the above two could generate the initial contour surface. Finally, a localized region active contour model is utilized to evolve the surface to achieve the accurate delineation of the tumors. The developed method was evaluated on numerical phantom data, synthetic BRATS (Multimodal Brain Tumor Image Segmentation challenge) data, and clinical patients’ data. The auto-segmentation results were quantitatively evaluated by comparing to ground truths with both volume and surface similarity metrics. Results: DICE coefficient (DC) was performed as a quantitative metric to evaluate the auto-segmentation in the numerical phantom with 8 tumors. DCs are 0.999±0.001 without noise, 0.969±0.065 with Rician noise and 0.976±0.038 with Gaussian noise. DC, NMI (Normalized Mutual Information), SSIM (Structural Similarity) and Hausdorff distance (HD) were calculated as the metrics for the BRATS and patients’ data. Assessment of BRATS data across 25 tumor segmentation yield DC 0.886±0.078, NMI 0.817±0.108, SSIM 0.997±0.002, and HD 6.483±4.079mm. Evaluation on 8 patients with total 14 tumor sites yield DC 0.872±0.070, NMI 0.824±0.078, SSIM 0.999±0.001, and HD 5.926±6.141mm. Conclusion: The developed automatic segmentation strategy, which yields accurate brain tumor delineation in evaluation cases, is promising for its application in SRS treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-C-206-07: A Practical Sparse View Ultra-Low Dose CT Acquisition Scheme for PET Attenuation Correction in the Extended Scan Field-Of-View

Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CT technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.

60 APPLIED LIFE SCIENCES↗

SU-C-209-05: Monte Carlo Model of a Prototype Backscatter X-Ray (BSX) Imager for Projective and Selective Object-Plane Imaging

Purpose: To develop a Monte Carlo N-Particle (MCNP) model for the validation of a prototype backscatter x-ray (BSX) imager, and optimization of BSX technology for medical applications, including selective object-plane imaging. Methods: BSX is an emerging technology that represents an alternative to conventional computed tomography (CT) and projective digital radiography (DR). It employs detectors located on the same side as the incident x-ray source, making use of backscatter and avoiding ring geometry to enclose the imaging object. Current BSX imagers suffer from low spatial resolution. A MCNP model was designed to replicate a BSX prototype used for flaw detection in industrial materials. This prototype consisted of a 1.5mm diameter 60kVp pencil beam surrounded by a ring of four 5.0cm diameter NaI scintillation detectors. The imaging phantom consisted of a 2.9cm thick aluminum plate with five 0.6cm diameter holes drilled halfway. The experimental image was created using a raster scanning motion (in 1.5mm increments). Results: A qualitative comparison between the physical and simulated images showed very good agreement with 1.5mm spatial resolution in plane perpendicular to incident x-ray beam. The MCNP model developed the concept of radiography by selective plane detection (RSPD) for BSX, whereby specific object planes can be imaged by varying kVp. 10keV increments in mean x-ray energy yielded 4mm thick slice resolution in the phantom. Image resolution in the MCNP model can be further increased by increasing the number of detectors, and decreasing raster step size. Conclusion: MCNP modelling was used to validate a prototype BSX imager and introduce the RSPD concept, allowing for selective object-plane imaging. There was very good visual agreement between the experimental and MCNP imaging. Beyond optimizing system parameters for the existing prototype, new geometries can be investigated for volumetric image acquisition in medical applications. This material is based upon work supported under an Integrated University Program Graduate Fellowship sponsored by the Department of Energy Office of Nuclear Energy.

60 APPLIED LIFE SCIENCES↗

SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation

Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes. The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.

60 APPLIED LIFE SCIENCES↗

SU-D-202-03: Statistical Segmentation On Quantitative CT for Assessing Spatial Tumor Response During Radiation Therapy Delivery

Purpose: Develop a method to segment regions of interest (ROIs) in tumor with statistically similar Hounsfield unit (HU) values and/or HU changes during chemoradiation therapy (CRT) delivery, to assess spatial tumor treatment response based on daily CTs during CRT delivery. Methods: Generate a three region map of ROIs with differential HUs, by sampling neighboring voxels around a selected voxel and comparing to the mean of the entire ROI using a t-test. The cumulative distribution function, P, is calculated from the t-test. The P value is assigned to be the value at the selected voxel, and this is repeated over all voxels in the initial ROI. Three regions are defined as: (1-P) < 0.00001 (mid region), and 0.00001 < (1-P) (mean greater than baseline and mean lower than baseline). The test is then expanded to compare daily CT sets acquired during routine CT-guided RT delivery using a CT-on-rails. The first fraction CT is used as the baseline for comparison. We tested 15 pancreatic head tumor cases undergoing CRT, to identify the ROIs and changes corresponding to normal, fibrotic, and tumor tissue. The obtained ROIs were compared with MRI-ADC maps acquired pre- and post-CRT. Results: The ROIs in 13 out of 15 patients’ first fraction CTs and pre-CRT MRIs matched the general region and slices covered, as well as in 6 out of the 9 patients with post-CRT MRIs. The high HU region designated by the t-test was seen to correlate with the tumor region in MR, and these ROIs are positioned within the same region over the course of treatment. In patients with poorly delineated tumors in MR, the t-test was inconclusive. Conclusion: The proposed statistical segmentation technique shows the potential to identify regions in tumor with differential HUs and HU changes during CRT delivery for patients with pancreas head cancer.

60 APPLIED LIFE SCIENCES↗

SU-D-207A-05: Investigating Sparse-Sampled MRI for Motion Management in Thoracic Radiotherapy

Purpose: Sparse sampling and reconstruction-based MRI techniques represent an attractive strategy to achieve sufficiently high image acquisition speed while maintaining image quality for the task of radiotherapy guidance. In this study, we examine rapid dynamic MRI using a sparse sampling sequence k-t BLAST in capturing motion-induced, cycle-to-cycle variations in tumor position. We investigate the utility of long-term MRI-based motion monitoring as a means of better characterizing respiration-induced tumor motion compared to a single-cycle 4DCT. Methods: An MRI-compatible, programmable, deformable lung motion phantom with eleven 1.5 ml water marker tubes was placed inside a 3.0 T whole-body MR scanner (Philips Ingenia). The phantom was programmed with 10 lung tumor motion traces previously recorded using the Synchrony system. 2D+t image sequences of a coronal slice were acquired using a balanced-SSFP sequence combined with k-t BLAST (accn=3, resolution=0.66×0.66×5 mm3; acquisition time = 110 ms/slice). kV fluoroscopic (ground truth) and 4DCT imaging was performed with the same phantom setup and motion trajectories. Marker positions in all three modalities were segmented and tracked using an opensource deformable image registration package, NiftyReg. Results: Marker trajectories obtained from rapid MRI exhibited <1 mm error compared to kv Fluoro trajectories in the presence of complex motion including baseline shifts and changes in respiratory amplitude, indicating the ability of MRI to monitor motion with adequate geometric fidelity for the purpose of radiotherapy guidance. In contrast, the trajectory derived from 4DCT exhibited significant errors up to 6 mm due to cycle-to-cycle variations and baseline shifts. Consequently, 4DCT was found to underestimate the range of marker motion by as much as 50%. Conclusion: Dynamic MRI is a promising tool for radiotherapy motion management as it permits for longterm, dose-free, soft-tissue-based monitoring of motion, yielding richer and more accurate information about tumor position and motion range compared to the current state-of-the-art, 4DCT. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

SU-D-207A-06: Pediatric Abdominal Organ Motion Quantified Via a Novel 4D MRI Method

Purpose: To develop a 4D MRI method for assessing respiration-induced abdominal organ motion in children receiving radiation therapy. Methods: A 4D MRI using internal image-based respiratory surrogate has been developed and implemented on a clinical scanner (1.5T Siemens Avanto). Ten patients (younger group: N=6, 2–5 years, anesthetized; older group: N=4, 11–15 years) with neuroblastoma, Wilm’s tumor rhabdomyosarcoma, or desmoplastic small round cell tumor received free breathing 4D MRI scans for treatment planning. Coronal image slices of the entire abdomen were retrospectively constructed in 10 respiratory phases. A B-spline deformable registration (Metz et al. 2011) was performed on 4D datasets to automatically derive motion trajectories of selected anatomical landmarks, including the dome and the center of the liver, and the superior edges of kidneys and spleen. The extents of the motion in three dimensions (anteroposterior, AP; mediolateral, ML; superoinferior, SI) and the correlations between organ motion trajectories were quantified. Results: The 4D MRI scans were successfully performed in <20 minutes for all patients without the use of any external device. Organ motion extents were larger in adolescents (kidneys: 3–13 mm SI, liver and spleen: 6–18 mm SI) than in younger children (kidneys:<3mm in all directions; liver and spleen: 1–8 mm SI, 1–5 mm ML and AP). The magnitude of respiratory motion in some adolescents may warrant special motion management. Motion trajectories were not synchronized across selected anatomical landmarks, particularly in the ML and AP directions, indicating inter- and intra-organ variations of the respiratory-induced motion. Conclusion: The developed 4D MRI acquisition and motion analysis methods provide a non-ionizing, non-invasive approach to automatically measure the organ motion trajectory in the pediatric abdomen. It is useful for defining ITV and PRV, monitoring changes in target motion patterns during the treatment course, and studying interplay effects in proton scanning.

60 APPLIED LIFE SCIENCES↗

SU-D-209-06: Study On the Dose Conversion Coefficients in Pediatric Radiography with the Development of Children Voxel Phantoms

Purpose: Conversion coefficients of organ dose normalized to entrance skin dose (ESD) are widely used to evaluate the organ doses directly using ESD without time-consuming dose measurement, this work aims to investigate the dose conversion coefficients in pediatric chest and abdomen radiography with the development of 5 years and 10 years old children voxel phantoms. Methods: After segmentation of organs and tissues from CT slice images of ATOM tissue-equivalent phantoms, a 5-year-old and a 10-year-old children computational voxel phantoms were developed for Monte Carlo simulation. The organ doses and the entrance skin dose for pediatric chest postero-anterior projection and abdominal antero-posterior projection were simulated at the same time, and then the organ dose conversion coefficients were calculated.To verify the simulated results, dose measurement was carried out with ATOM tissue-equivalent phantoms for 5 year chest radiography. Results: Simulated results and experimental results matched very well with each other, the result differences of all the organs covered in radiation field were below 16% for 5-year-old child in chest projection. I showed that the conversion coefficients of organs covered in the radiation field were much larger than organs out of the field for all the study cases, for example, the conversion coefficients of stomach, liver intestines, and pancreas are larger for abdomen radiography while conversion coefficients of lungs are larger for chest radiography. Conclusion: The voxel children phantoms were helpful to evaluate the radiation doses more accurately and efficiently. Radiation field was the essential factor that affects the organ dose, use reasonably small field should be encouraged for radiation protection. This work was supported by the National Natural Science Foundation of China(11475047)

60 APPLIED LIFE SCIENCES↗

SU-D-207B-04: Morphological Features of MRI as a Correlate of Capsular Contracture in Breast Cancer Patients with Implant-Based Reconstructions

Purpose: Capsular contracture (CC) is a serious complication in patients receiving implant-based reconstruction for breast cancer. The goal of this study was to identify image-based correlates of CC using MRI imaging in breast cancer patients who received both MRI and clinical evaluation following reconstructive surgery. Methods: We analyzed a retrospective dataset of 50 patients who had both a diagnostic MR and a plastic surgeon’s evaluations of CC score (Baker’s score) within a six month period following mastectomy and reconstructive surgery. T2w sagittal MRIs (TR/TE = 3500/102 ms, slice thickness = 4 mm) were used for morphological shape features (roundness, eccentricity, solidity, extent and ratio-length) and histogram features (median, skewness and kurtosis) of the implant and the pectoralis muscle overlying the implant. Implant and pectoralis muscles were segmented in 3D using Computation Environment for Radiological Research (CERR) and shape and histogram features were calculated as a function of Baker’s score. Results: Shape features such as roundness and eccentricity were statistically significant in differentiating grade 1 and grade 2 (p = 0.009; p = 0.06) as well as grade 1 and grade 3 CC (p = 0.001; p = 0.006). Solidity and extent were statistically significant in differentiating grade 1 and grade 3 CC (p = 0.04; p = 0.04). Ratio-length was statistically significant in differentiating all grades of CC except grade 2 and grade 3 that showed borderline significance (p = 0.06). The muscle thickness, median intensity and kurtosis were significant in differentiating between grade 1 and grade 3 (p = 0.02), grade 1 and grade 2 (p = 0.03) and grade 1 and grade 3 (p = 0.01) respectively. Conclusion: Morphological shape features described on MR images were associated with the severity of CC. MRI may be important in objectively evaluating outcomes in breast cancer patients who undergo implant reconstruction.

60 APPLIED LIFE SCIENCES↗

SU-F-R-18: Updates to the Computational Environment for Radiological Research for Image Analysis

Purpose: To present new tools in CERR for Texture Analysis and Visualization. Method: (1) Quantitative Image Analysis: We added the ability to compute Haralick texture features based on local neighbourhood. The Texture features depend on many parameters used in their derivation. For example: (a) directionality, (b) quantization of image, (c) patch-size for the neighborhood, (d) handling of the edge voxels within the region of interest, (e) Averaging co-occurance matrix vs texture features for different directions etc. A graphical user interface was built to set these parameters and then visualize their impact on the resulting texture maps. The entire functionality was written in Matlab. Array indexing was used to speed up the texture calculation. The computation speed is very competitive with the ITK library. Moreover, our implementation works with multiple CPUs and the computation time can be further reduced by using multiple processor threads. In order to reduce the Haralick texture maps into scalar features, we propose the use of Texture Volume Histograms. This lets users make use of the entire distribution of texture values within the region of interest rather than using just the mean and the standard deviations. (2) Qualitative/Visualization tools: The derived texture maps are stored as a new scan (derived) within CERR’s planC data structure. A display that compares various scans was built to show the raw image and the derived texture maps side-by-side. These images are positionally linked and can be navigated together. CERR’s graphics handling was updated and sped-up to be compatible with the newer Matlab versions. As a result, the users can use (a) different window levels and colormaps for different viewports, (b) click-and-drag or use mouse scroll-wheel to navigate slices. Results: The new features and updates are available via https://www.github.com/adityaapte/cerr . Conclusion: Features added to CERR increase its utility in Radiomics and Outcomes modeling.

60 APPLIED LIFE SCIENCES↗

SU-F-R-22: Malignancy Classification for Small Pulmonary Nodules with Radiomics and Logistic Regression

Purpose: We conducted a retrospective study of Radiomics research for classifying malignancy of small pulmonary nodules. A machine learning algorithm of logistic regression and open research platform of Radiomics, IBEX (Imaging Biomarker Explorer), were used to evaluate the classification accuracy. Methods: The training set included 100 CT image series from cancer patients with small pulmonary nodules where the average diameter is 1.10 cm. These patients registered at Chang Gung Memorial Hospital and received a CT-guided operation of lung cancer lobectomy. The specimens were classified by experienced pathologists with a B (benign) or M (malignant). CT images with slice thickness of 0.625 mm were acquired from a GE BrightSpeed 16 scanner. The study was formally approved by our institutional internal review board. Nodules were delineated and 374 feature parameters were extracted from IBEX. We first used the t-test and p-value criteria to study which feature can differentiate between group B and M. Then we implemented a logistic regression algorithm to perform nodule malignancy classification. 10-fold cross-validation and the receiver operating characteristic curve (ROC) were used to evaluate the classification accuracy. Finally hierarchical clustering analysis, Spearman rank correlation coefficient, and clustering heat map were used to further study correlation characteristics among different features. Results: 238 features were found differentiable between group B and M based on whether their statistical p-values were less than 0.05. A forward search algorithm was used to select an optimal combination of features for the best classification and 9 features were identified. Our study found the best accuracy of classifying malignancy was 0.79±0.01 with the 10-fold cross-validation. The area under the ROC curve was 0.81±0.02. Conclusion: Benign nodules may be treated as a malignant tumor in low-dose CT and patients may undergo unnecessary surgeries or treatments. Our study may help radiologists to differentiate nodule malignancy for low-dose CT.

60 APPLIED LIFE SCIENCES↗

SU-F-R-30: Interscanner Variability of Radiomics Features in Computed Tomography (CT) Using a Standard ACR Phantom

Purpose: A simple approach to investigate Interscanner variability of Radiomics features in computed tomography (CT) using a standard ACR phantom. Methods: The standard ACR phantom was scanned on CT scanners from three different manufacturers. Scanning parameters of 120 KVp, 200 mA were used while slice thickness of 3.0 mm on two scanners and 3.27 mm on third scanner was used. Three spherical regions of interest (ROI) from water, medium density and high density inserts were contoured. Ninety four Radiomics features were extracted using an in-house program. These features include shape (11), intensity (22), GLCM (26), GLZSM (11), RLM (11), and NGTDM (5) and 8 fractal dimensions features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) is calculated for each feature group. Each group is further classified according to the COV- by calculating the percentage of features in each of the following categories: COV less than 2%, between 2 and 10% and greater than 10%. Results: For all feature groups, similar trend was observed for three different inserts. Shape features were the most robust for all scanners as expected. 70% of the shape features had COV <2%. For intensity feature group, 2% COV varied from 9 to 32% for three scanners. All features in four groups GLCM, GLZSM, RLM and NGTDM were found to have Interscanner variability ≥2%. The fractal dimensions dependence for medium and high density inserts were similar while it was different for water inserts. Conclusion: We concluded that even for similar scanning conditions, Interscanner variability across different scanners was significant. The texture features based on GLCM, GLZSM, RLM and NGTDM are highly scanner dependent. Since the inserts of the ACR Phantom are not heterogeneous in HU values suggests that matrix based 2nd order features are highly affected by variation in noise. Research partly funded by NIH/NCI R01CA190105-01.

60 APPLIED LIFE SCIENCES↗

SU-F-R-32: Evaluation of MRI Acquisition Parameter Variations On Texture Feature Extraction Using ACR Phantom

Purpose: To investigate the sensitivity of classic texture features to variations of MRI acquisition parameters. Methods: This study was performed on American College of Radiology (ACR) MRI Accreditation Program Phantom. MR imaging was acquired on a GE 750 3T scanner with XRM explain gradient, employing a T1-weighted images (TR/TE=500/20ms) with the following parameters as the reference standard: number of signal average (NEX) = 1, matrix size = 256×256, flip angle = 90°, slice thickness = 5mm. The effect of the acquisition parameters on texture features with and without non-uniformity correction were investigated respectively, while all the other parameters were kept as reference standard. Protocol parameters were set as follows: (a). NEX = 0.5, 2 and 4; (b).Phase encoding steps = 128, 160 and 192; (c). Matrix size = 128×128, 192×192 and 512×512. 32 classic texture features were generated using the classic gray level run length matrix (GLRLM) and gray level co-occurrence matrix (GLCOM) from each image data set. Normalized range ((maximum-minimum)/mean) was calculated to determine variation among the scans with different protocol parameters. Results: For different NEX, 31 out of 32 texture features’ range are within 10%. For different phase encoding steps, 31 out of 32 texture features’ range are within 10%. For different acquisition matrix size without non-uniformity correction, 14 out of 32 texture features’ range are within 10%; for different acquisition matrix size with non-uniformity correction, 16 out of 32 texture features’ range are within 10%. Conclusion: Initial results indicated that those texture features that range within 10% are less sensitive to variations in T1-weighted MRI acquisition parameters. This might suggest that certain texture features might be more reliable to be used as potential biomarkers in MR quantitative image analysis.

60 APPLIED LIFE SCIENCES↗

SU-F-R-39: Effects of Radiation Dose Reduction On Renal Cell Carcinoma Discrimination Using Multi-Phasic CT Imaging

Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom) measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant Support from: U01 CA181156.

60 APPLIED LIFE SCIENCES↗

SU-F-R-48: Early Prediction of Pathological Response of Locally Advanced Rectal Cancer Using Perfusion CT:A Prospective Clinical Study

Purpose: To prospectively evaluate the tumor vascularity assessed by perfusion CT for prediction of chemo-radiation treatment (CRT) response in locally advanced rectal cancer (LARC). Methods: Eighteen consecutive patients (61.9±8.8 years, from March–June 2015) diagnosed with LARC who underwent 6–8 weeks CRT followed by surgery were included. The pre-treatment perfusion CT was acquired after a 5s delay of contrast agent injection for 45s with 1s interval. A total of 7-cm craniocaudal range covered the tumor region with 3-mm slice thickness. The effective radiation dose is around 15mSv, which is about 1.5 the conventional abdomen/pelvis CT dose. The parametric map of blood flow (BF), blood volume (BV), mean transit time (MTT), permeability (PMB), and maximum intensity map (MIP) were obtained from commercial software (Syngo-CT 2011A, Siemens). An experienced radiation oncologist outlined the tumor based on the pre-operative MR and pathologic residual region, but was blinded with regards to pathological tumor stage. The perfusion parameters were compared to histopathological response quantified by tumor regression grade as good-responder (GR, TRG 0-1) vs. non-good responder (non-GR). Furthermore, the predictive value for pathological complete response (pCR) was also investigated. Results: Both BV (p=0.02) and MTT (P=0.02) was significantly higher and permeambility was lower (p=0.004) in the good responders. The BF was higher in GR group but not statistically significant. Regarding the discrimination of pCR vs non-pCR, the BF was higher in the pCR group (p=0.08) but none of those parameters showed statistically significant differences. Conclusion: BV and MTT can discriminate patients with a favorable response from those that fail to respond well, potentially selecting high-risk patients with resistant tumors that may benefit from an aggressive preoperative treatment approach. However, future studies with more patient data are needed to verify the prognostic value of perfusion CT especially for pCR prediction. This work is supported by the National High-tech R&D program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917), Natural Science Foundation of China (NSFC Grant No. 81201091).

60 APPLIED LIFE SCIENCES↗