Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Mesoscopic quantum cryptography

Since a strictly single-photon source is not yet available, in quantum cryptography systems, one uses, as information quantum states, coherent radiation of a laser with an average number of photons of μ ≈ 0.1–0.5 in a pulse, attenuated to the quasi-single-photon level. The linear independence of a set of coherent quasi-single-photon information states leads to the possibility of unambiguous measurements that, in the presence of losses in the line, restrict the transmission range of secret keys. Starting from a certain value of critical loss (the length of the line), the eavesdropper knows the entire key, does not make errors, and is not detected—the distribution of secret keys becomes impossible. This problem is solved by introducing an additional reference state with an average number of photons of μ{sub cl} ≈ 10{sup 3}–10{sup 6}, depending on the length of the communication line. It is shown that the use of a reference state does not allow the eavesdropper to carry out measurements with conclusive outcome while remaining undetected. A reference state guarantees detecting an eavesdropper in a channel with high losses. In this case, information states may contain a mesoscopic average number of photons in the range of μ{sub q} ≈ 0.5–10{sup 2}. The protocol proposed is easy to implement technically, admits flexible adjustment of parameters to the length of the communication line, and is simple and transparent for proving the secrecy of keys.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

QA/QC-ed Groundwater Level Time Series in PLM-1 and PLM-6 Monitoring Wells, East River, Colorado (2016-2022)

This data set contains QA/QC-ed (Quality Assurance and Quality Control) water level data for the PLM1 and PLM6 wells. PLM1 and PLM6 are location identifiers used by the Watershed Function SFA project for two groundwater monitoring wells along an elevation gradient located along the lower montane life zone of a hillslope near the Pumphouse location at the East River Watershed, Colorado, USA. These wells are used to monitor subsurface water and carbon inventories and fluxes, and to determine the seasonally dependent flow of groundwater under the PLM hillslope. The downslope flow of groundwater in combination with data on groundwater chemistry (see related references) can be used to estimate rates of solute export from the hillslope to the floodplain and river. QA/QC analysis of measured groundwater levels in monitoring wells PLM-1 and PLM-6 included identification and flagging of duplicated values of timestamps, gap filling of missing timestamps and water levels, removal of abnormal/bad and outliers of measured water levels. The QA/QC analysis also tested the application of different QA/QC methods and the development of regular (5-minute, 1-hour, and 1-day) time series datasets, which can serve as a benchmark for testing other QA/QC techniques, and will be applicable for ecohydrological modeling. The package includes a Readme file, one R code file used to perform QA/QC, a series of 8 data csv files (six QA/QC-ed regular time series datasets of varying intervals (5-min, 1-hr, 1-day) and two files with QA/QC flagging of original data), and three files for the reporting format adoption of this dataset (InstallationMethods, file level metadata (flmd), and data dictionary (dd) files).QA/QC-ed data herein were derived from the original/raw data publication available at Williams et al., 2020 (DOI: 10.15485/1818367). For more information about running R code file (10.15485_1866836_QAQC_PLM1_PLM6.R) to reproduce QA/QC output files, see README (QAQC_PLM_readme.docx). This dataset replaces the previously published raw data time series, and is the final groundwater data product for the PLM wells in the East River. Complete metadata information on the PLM1 and PLM6 wells are available in a related dataset on ESS-DIVE: Varadharajan C, et al (2022). https://doi.org/10.15485/1660962. These data products are part of the Watershed Function Scientific Focus Area collection effort to further scientific understanding of biogeochemical dynamics from genome to watershed scales. 2022/09/09 Update: Converted data files using ESS-DIVE’s Hydrological Monitoring Reporting Format. With the adoption of this reporting format, the addition of three new files (v1_20220909_flmd.csv, V1_20220909_dd.csv, and InstallationMethods.csv) were added. The file-level metadata file (v1_20220909_flmd.csv) contains information specific to the files contained within the dataset. The data dictionary file (v1_20220909_dd.csv) contains definitions of column headers and other terms across the dataset. The installation methods file (InstallationMethods.csv) contains a description of methods associated with installation and deployment at PLM1 and PLM6 wells. Additionally, eight data files were re-formatted to follow the reporting format guidance (er_plm1_waterlevel_2016-2020.csv, er_plm1_waterlevel_1-hour_2016-2020.csv, er_plm1_waterlevel_daily_2016-2020.csv, QA_PLM1_Flagging.csv, er_plm6_waterlevel_2016-2020.csv, er_plm6_waterlevel_1-hour_2016-2020.csv, er_plm6_waterlevel_daily_2016-2020.csv, QA_PLM6_Flagging.csv). The major changes to the data files include the addition of header_rows above the data containing metadata about the particular well, units, and sensor description. 2023/01/18 Update: Dataset updated to include additional QA/QC-ed water level data up until 2022-10-12 for ER-PLM1 and 2022-10-13 for ER-PLM6. Reporting format specific files (v2_20230118_flmd.csv, v2_20230118_dd.csv, v2_20230118_InstallationMethods.csv) were updated to reflect the additional data. R code file (QAQC_PLM1_PLM6.R) was added to replace the previously uploaded HTML files to enable execution of the associated code. R code file (QAQC_PLM1_PLM6.R) and ReadMe file (QAQC_PLM_readme.docx) were revised to clarify where original data was retrieved from and to remove local file paths.

54 ENVIRONMENTAL SCIENCES↗

Hot Coordinate Measuring Machine Technology Assessment (U)

The goal of this report is to document a technology assessment performed following the guidance created by LA-UR-13-22870, “Hot Coordinate Measuring Machine Technical Specifications and Requirements (U)”. The intent was to capture specific values for technical specifications and requirements listed by the guide and assign a weight factors based on TA-55 importance. After the information was obtained, an optimal coordinate measuring machine for TA-55 was revealed – Hexagon’s Leitz Reference Xi 15.9.7. An internal look at on-site technology revealed that the current Hot CMM (Xcel 765) has the worst performance specification or accuracy statement of all CMMs currently at LANL. A look at Quindos license file options revealed that while most machines appear to have a standard set of options, some machines appear to be missing options and may contain unneeded ones. Controller firmware versions also appear to not be standardized at this time.

42 ENGINEERING↗

Finding beam loss locations in a linac with oscillating dipole correctors

The paper proposes a method of finding the beam loss locations in a linac. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync produces a line at the corresponding frequency in spectra of current-sensitive devices downstream of the loss point. The phase of this signal contains information about the location of the beam loss. Similar lines appear also in the position signals of Beam Position Monitors (BPMs). The phases of the BPM position lines change monotonically (within each 2π) along the linac and can be used a reference system. The phase of the loss signal compared with this reference system pinpoints the beam loss location, assuming that longitudinal coordinates of the BPMs are known. If the correctors deflection amplitudes and the phase offset between their waveforms are chosen optimally and well calibrated, the same measurement provides values of the β-function and the betatron phase advance at the BPM locations. Optics measurements of this type can be made parasitically, with negligible effect on the emittance, if a long measurement time is acceptable.

43 PARTICLE ACCELERATORS↗

Weak Form Scientific Machine Learning: Test Function Construction for System Identification

Weak form Scientific Machine Learning (WSciML) is a recently developed framework for data-driven modeling and scientific discovery. It leverages the weak form of equation error residuals to provide enhanced noise robustness in system identification via convolving model equations with test functions, reformulating the problem to avoid direct differentiation of data. The performance, however, relies on wisely choosing a set of compactly supported test functions. In this work, we mathematically motivate a novel data-driven method for constructing Single-scale-Local reference functions for creating the set of test functions. Our approach numerically approximates the integration error introduced by the quadrature and identifies the support size for which the error is minimal, without requiring access to the model parameter values. Through numerical experiments across various models, noise levels, and temporal resolutions, we demonstrate that the selected supports consistently align with regions of minimal parameter estimation error. We also compare the proposed method against the strategy for constructing Multi-scale-Global (and orthogonal) test functions introduced in our prior work, demonstrating the improved computational efficiency.

FOS: Computer and information sciences↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Nonnegative canonical tensor decomposition with linear constraints: nnCANDELINC

Abstract There is an emerging interest for tensor factorization applications in big‐data analytics and machine learning. To speed up the factorization of extra‐large datasets, organized in multidimensional arrays (also known as tensors), easy to compute compression‐based tensor representations, such as, Tucker and tensor train formats, are used to approximate the initial large‐tensor. Further, tensor factorization is used to extract latent features that can facilitate discoveries of new mechanisms and signatures hidden in the data, where the explainability of the latent features is of principal importance. Nonnegative tensor factorization extracts latent features that are naturally sparse and parts of the data, which makes them easily interpretable. However, to take into account available domain knowledge and subject matter expertise, often additional constraints need to be imposed, which lead us to canonical decomposition with linear constraints (CANDELINC), a canonical polyadic decomposition with rank deficient factors. In CANDELINC, Tucker compression is used as a preprocessing step, which lead to a larger residual error but to more explainable latent features. Here, we propose a nonnegative CANDELINC (nnCANDELINC) accomplished via a specific nonnegative Tucker decomposition; we refer to as minimal or canonical nonnegative Tucker. We derive several results required to understand the specificity of nnCANDELINC, focusing on the difficulties of preserving the nonnegative rank of a tensor to its Tucker core and comparing the real valued to nonnegative case. Finally, we demonstrate nnCANDELINC performance on synthetic and real‐world examples.

97 MATHEMATICS AND COMPUTING↗

Universality of quantum information in chaotic CFTs

We study the Eigenstate Thermalization Hypothesis (ETH) in chaotic conformal field theories (CFTs) of arbitrary dimensions. Assuming local ETH, we compute the reduced density matrix of a ball-shaped subsystem of finite size in the infinite volume limit when the full system is an energy eigenstate. This reduced density matrix is close in trace distance to a density matrix, to which we refer as the ETH density matrix , that is independent of all the details of an eigenstate except its energy and charges under global symmetries. In two dimensions, the ETH density matrix is universal for all theories with the same value of central charge. We argue that the ETH density matrix is close in trace distance to the reduced density matrix of the (micro)canonical ensemble. We support the argument in higher dimensions by comparing the Von Neumann entropy of the ETH density matrix with the entropy of a black hole in holographic systems in the low temperature limit. Finally, we generalize our analysis to the coherent states with energy density that varies slowly in space, and show that locally such states are well described by the ETH density matrix.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Patient Dose Reference Levels for Interventional Radiology: A National Approach

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm{sup 2} for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm{sup 2} for lower limb arteriography (685 cases), 89 Gy cm{sup 2} for renal arteriography (55 cases), 80 Gy cm{sup 2} for biliary drainage (205 cases), 289 Gy cm{sup 2} for hepatic chemoembolization (151 cases), 94 Gy cm{sup 2} for iliac stent (70 cases), and 236 Gy cm{sup 2} for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancement of the efficiency of dye-sensitized solar cell with multi-wall carbon nanotubes/polypyrrole composite counter electrodes prepared by electrophoresis/electrochemical polymerization

Graphical abstract: The overall energy conversion efficiency of the DSSC employing the MWCNT/PPy CE reached 3.78%. Compared with a reference DSSC using single MWCNT film CE with efficiency of 2.68%, the energy conversion efficiency was increased by 41.04%. Highlights: ► MWCNT/PPy composite film prepared by electrodeposition layer by layer was used as counter electrode in DSSC. ► The overall energy conversion efficiency of the DSSC was 3.78% by employing the composite film. ► The energy conversion efficiency increased by 41.04% compared with efficiency of 2.68% by using the single MWCNT film. ► We analyzed the mechanism and influence factor of electron transfer in the composite electrode by EIS. - Abstract: For the purpose of replacing the precious Pt counter electrode in dye-sensitized solar cells (DSSCs) with higher energy conversion efficiency, multi-wall carbon nanotube (MWCNT)/polypyrrole (PPy) double layers film counter electrode (CE) was fabricated by electrophoresis and cyclic voltammetry (CV) layer by layer. Atom force microscopy (AFM), scanning electron microscopy (SEM) and transmission electron microscope (TEM) demonstrated the morphologies of the composite electrode and Raman spectroscopy verified the PPy had come into being. The overall energy conversion efficiency of the DSSC employing the MWCNT/PPy CE reached 3.78%. Compared with a reference DSSC using single MWCNT film CE with efficiency of 2.68%, the energy conversion efficiency was increased by 41.04%. The result of impedance showed that the charge transfer resistance R{sub ct} of the MWCNT/PPy CE had the lowest value compared to that of MWCNT or PPy electrode. These results indicate that the composite film with high conductivity, high active surface area, and good catalytic properties for I{sub 3}{sup −} reduction can potentially be used as the CE in a high-performance DSSC.

36 MATERIALS SCIENCE↗

Molecular dynamics simulations of the amino acid-ZnO (10-10) interface: A comparison between density functional theory and density functional tight binding results

We investigate the adsorption behavior of four different amino acids (glutamine, glutamate, serine, cysteine) on the zinc oxide (101{sup ¯}0) surface, comparing the geometry and energy associated with a number of different adsorption configurations. In doing this, we highlight the benefits and limits of using density-functional tight-binding (DFTB) with respect to standard density functional theory (DFT). The DFTB method is found to reliably reproduce the DFT adsorption geometries. Analysis of the adsorption configurations emphasizes the fundamental role of the first hydration layer in mediating the interactions between the amino acids and the surface. Direct surface-molecule bonds are found to form predominantly via the carboxylate groups of the studied amino acids. No surface-mediated chemical reactions are observed, with the notable exception of a proton transfer from the thiol group of cysteine to a hydroxyl group of the surface hydration layer. The adsorption energies are found to be dominated both by the formation of direct or indirect surface-molecule hydrogen bonds, but also by the rearrangement of the hydrogen-bond network in surface proximity in a non-intuitive way. Energetic comparisons between DFTB and DFT are made difficult on one side by the long time necessary to achieve convergence of potential energy values in MD simulations and on the other side by the necessity of including higher-order corrections to DFTB to obtain a good description of the hydrogen bond energetics. Overall, our results suggest that DFTB is a good reference method to set the correct chemical states and the initial geometries of hybrid biomolecule/ZnO systems to be simulated with non-reactive force fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lanthanide recognition: determination of thulium(III) ions in presence of other rare earth elements by a thulium(III) sensor based on 4-methyl-1,2-Bis(2-Pyridinecarboxamido)benzene as a sensing material

In this research, a novel thulium(III) potentiometric membrane sensor based on 4-methyl-1,2-bis(2-pyridinecarboxamido) benzene (MPB) is described. The sensor exhibits a Nernstian response over a concentration range of 1.010-7M to 1.010-1M, with a detection limit of 9.010-8M. The best performance was achieved with a membrane composition of 30% PVC, 60% nitrobenzene (NB), 6% MPB, and 4% sodium tetraphenylborate (NaTPB). It was found that at the pH range of 3.6 to 9.0, the potential response of the sensor was not affected by the pH. Furthermore, the electrode presents satisfactory reproducibility, very fast response time (15s), and relatively good discriminating ability for Tm(III) ions with respect to many common cations and lanthanide ions. The validation of the proposed electrode was tested by using Coal and Fuel Ash (FFA 1 Fly Ash) as a Certified Reference Material (CRM).

01 COAL, LIGNITE, AND PEAT↗

LIFTING THE DUSTY VEIL WITH NEAR- AND MID-INFRARED PHOTOMETRY. I. DESCRIPTION AND APPLICATIONS OF THE RAYLEIGH-JEANS COLOR EXCESS METHOD

The Milky Way (MW) remains a primary laboratory for understanding the structure and evolution of spiral galaxies, but typically we are denied clear views of MW stellar populations at low Galactic latitudes because of extinction by interstellar dust. However, the combination of Two Micron All-Sky Survey (2MASS) near-infrared (NIR) and Spitzer-IRAC mid-infrared (MIR) photometry enables a powerful method for determining the line-of-sight reddening to any star: the sampled wavelengths lie in the Rayleigh-Jeans part of the spectral energy distribution of most stars, where, to first order, all stars have essentially the same intrinsic color. Thus, changes in stellar NIR-MIR colors due to interstellar reddening are readily apparent, and (under an assumed extinction law) the observed colors and magnitudes of stars can be easily and accurately restored to their intrinsic values, greatly increasing their usefulness for Galactic structure studies. In this paper, we explore this 'Rayleigh-Jeans Color Excess' (RJCE) method and demonstrate that use of even a simple variant of the RJCE method based on a single reference color, (H -[4.5{mu}]), can rather accurately remove dust effects from previously uninterpretable 2MASS color-magnitude diagrams of stars in fields along the heavily reddened Galactic midplane, with results far superior to those derived from application of other dereddening methods. We also show that 'total' Galactic midplane extinction looks rather different from that predicted using 100{mu} emission maps from the IRAS/ISSA and COBE/DIRBE instruments as presented by Schlegel et al. Instead, the Galactic midplane extinction strongly resembles the distribution of {sup 13}CO (J = 1{yields}0) emission. Future papers will focus on refining the RJCE method and applying the technique to understand better not only dust and its distribution but also the distribution of stars intermixed with the dust in the low-latitude Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

FORBIDDEN AND INTERCOMBINATION LINES OF RR TELESCOPII: WAVELENGTH MEASUREMENTS AND ENERGY LEVELS

Ultraviolet and visible spectra of the symbiotic nova RR Telescopii are used to derive reference wavelengths for many forbidden and intercombination transitions of ions +1 to +6 of elements C, N, O, Ne, Na, Mg, Al, Si, P, S, Cl, Ar, K, and Ca. The wavelengths are then used to determine new energy values for the levels within the ions' ground configurations or first excited configuration. The spectra were recorded by the Space Telescope Imaging Spectrograph of the Hubble Space Telescope and the Ultraviolet Echelle Spectrograph of the European Southern Observatory in 2000 and 1999, respectively, and cover 1140-6915 A. Particular care was taken to assess the accuracy of the wavelength scale between the two instruments. An investigation of the profiles of the emission lines reveals that the nebula consists of at least two plasma components at different velocities. The components have different densities, and a simple model of the lines' emissions demonstrates that most of the lines principally arise from the high density component. Only these lines were used for the wavelength study.

79 ASTRONOMY AND ASTROPHYSICS↗

Superallowed 0 + → 0 + nuclear β decays: 2020 critical survey, with implications for V ud and CKM unitarity

A new critical survey of all half-life, decay-energy and branching-ratio measurements related to 23 superallowed 0 + → 0 + β decays is presented. Included are 222 individual measurements of comparable precision obtained from 174 published references. Compared with our last survey in 2015, we have added results from 28 new publications and eliminated an approximately equal number whose results have been superseded by much more precise modern data. We obtain world-average ft values for each of the 21 transitions that have a complete set of data, then apply radiative and isospin-symmetry-breaking corrections to extract “corrected” Ft values. Fifteen of these Ft values now have a precision of 0.3% or better and all take the same value within statistics, as expected from conservation of the vector current. Their average, Ft¯, when combined with the muon lifetime, yields the up-down quark-mixing element of the Cabibbo-Kobayashi-Maskawa matrix, V ud = 0.97373 ± 0.00031. This is lower than our 2015 result by one standard deviation and its uncertainty is increased by 50%. This is a consequence, not of any shifts in the experimental data, but of new calculations for the radiative corrections. The lower V ud value now leads to greater tension in the top-row test of unitarity in the CKM matrix. Updates in experimental data have independently led to a factor-of-two tighter limit being set on the possible existence of a scalar interaction. In conclusion, the new limit on Fierz interference is b F ≤ 0.0033 at the 90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

μSR study of Eu{sub 0.8}Ce{sub 0.2}Mn{sub 2}O{sub 5} and EuMn{sub 2}O{sub 5} multiferroics

A comparative μSR study of ceramic samples of the EuMn{sub 2}O{sub 5} and Eu{sub 0.8}Ce{sub 0.2}Mn{sub 2}O{sub 5} multiferroics is performed in the temperature range from 15 to 300 K. It is found that the Ce doping of the EuMn{sub 2}O{sub 5} sample slightly reduces the temperature of the magnetic phase transition from T{sub N} = 45 K for the EuMn{sub 2}O{sub 5} sample to T{sub N} = 42.5 K for the Eu{sub 0.8}Ce{sub 0.2}Mn{sub 2}O{sub 5} sample. Below the temperature T{sub N} for both samples, there are two types of localization of a thermalized muon with different temperature dependences of the precession frequency of the magnetic moment of the muon in an internal magnetic field. The higher frequency in both samples refers to the initial antiferromagnetic matrix. The behavior of this frequency in Eu{sub 0.8}Ce{sub 0.2}Mn{sub 2}O{sub 5} follows the Curie–Weiss law with the exponent β = 0.29 ± 0.02, which differs from the value β = 0.39 standard for 3D Heisenberg magnetics and is observed in EuMn{sub 2}O{sub 5}, because of the strong frustration of the doped sample. The temperature-independent low frequency is due to the presence of Mn{sup 3+}–Mn{sup 4+} ferromagnetic pairs located along the b axis of the antiferromagnetic matrix and in the regions of phase separation, which contain such ion pairs and e{sub g} electrons recharging them. In both samples, polarization losses are the same (about 20%) and are associated with the formation of Mn{sup 4+}–Mn{sup 4+} + Mu complexes near Mn{sup 3+}–Mn{sup 4+} ferromagnetic pairs. In the temperature interval from 25 to 45 K, the separation of the Eu{sub 0.8}Ce{sub 0.2}Mn{sub 2}O{sub 5} structure into two fractions where the relaxation rates of polarization of muons differ by an order of magnitude is revealed. This effect is due to a change in the state of regions of phase separation (1D superlattices) at the indicated temperatures. Such effect in EuMn{sub 2}O{sub 5} is significantly weaker.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MetaStrider: Architectures for Scalable Memory-centric Reduction of Sparse Data Streams

Reduction is an operation performed on the values of two or more key-value pairs that share the same key. Reduction of sparse data streams finds application in a wide variety of domains such as data and graph analytics, cybersecurity, machine learning, and HPC applications. However, these applications exhibit low locality of reference, rendering traditional architectures and data representations inefficient. This article presents MetaStrider, a significant algorithmic and architectural enhancement to the state-of-the-art, SuperStrider. Furthermore, these enhancements enable a variety of parallel, memory-centric architectures that we propose, resulting in demonstrated performance that scales near-linearly with available memory-level parallelism.

97 MATHEMATICS AND COMPUTING↗

Internal Mammary Chain Sentinel Nodes in Early-Stage Breast Cancer Patients: Toward Selective Removal

Background: Removal of internal mammary chain sentinel nodes (IMCSNs) affects prognosis and treatment of breast cancer, and internal mammary chain radiotherapy (IMCRT) can improve survival for selected patients. This study aimed to determine the effect of IMCSN biopsy on recurrence-free survival (RFS) and overall survival (OS) and to identify predictive factors for IMCSN and distant metastasis. Methods: Patients with IMCSNs were selected from a prospective database for the period 1999–2007. Lymphoscintigraphy was performed after intratumoral technetium-99 m injection, and all sentinel nodes were removed. Both RFS and OS were calculated for subgroups with tumor-positive, tumor-negative, or non-removed IMCSNs. Predictive factors were identified for tumor-positive IMCSNs and distant metastasis by regression analysis. Results: For 287 (85%) of 336 patients, IMCSN biopsy was performed, and metastasis was detected in 38 patients (13%). The patients with tumor-positive IMCSNs had poorer OS than the patients with no IMCSN metastasis or non-removed IMCSNs (p = 0.002). These patients also had worse RFS due to distant metastasis (p = 0.002). Axillary metastasis was predictive for tumor-positive IMCSNs (positive predictive value, 38.5%). The predictive factors for distant metastasis were tumor-positive IMCSNs (hazard ratio [HR], 2.5), non-removed IMCSNs (HR, 2.3), tumor diameter greater than 1.5 cm (HR, 3.5), and age older than 65 years (HR, 3.1; reference, < 50 years). Conclusions: Patients with IMCSNs have worse survival due to distant metastasis. The clinically relevant predictive factor for distant metastasis is tumor larger than 1.5 cm. According to the authors’ current protocol, IMCSN biopsy is performed for patients younger than 70 years who have a tumor larger than 1.5 cm, with the cardiotoxicity of the adjuvant IMCRT weighed against the survival benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗