Hexavalent Chrome Free Coatings for Electronics Electromagnetic Interference (EMI) Shielding Effectiveness (SE) Interim Test Report

Test specimen configuration was provided by Parker Chomerics. The EMI gasket used in this project was Cho-Seal 6503E. Black oxide alloy steel socket head bolts were used to hold the plates together. Non-conductive spacers were used to control the amount of compression on the gaskets. The following test fixture specifications were provided by Parker Chomerics. The CHO‐TP09 test plate sets selected for this project consist of two aluminum plates manufactured to the specifications detailed in CHO­‐TP09. The first plate, referred to as the test frame, is illustrated in Figure 1. The test frame is designed with a cutout in the center and two alternating bolt patterns. One pattern is used to bolt the test frame to the corresponding test cover plate (Figure 2), forming a test plate set. The second pattern accepts the hardware used to mount the fully assembled test plate set to the main adapter plate (Figure 3).

trivalent chromium↗

Terminal Descent Sensor Simulation

Sulcata software simulates the operation of the Mars Science Laboratory (MSL) radar terminal descent sensor (TDS). The program models TDS radar antennas, RF hardware, and digital processing, as well as the physics of scattering from a coherent ground surface. This application is specific to this sensor and is flexible enough to handle end-to-end design validation. Sulcata is a high-fidelity simulation and is used for performance evaluation, anomaly resolution, and design validation. Within the trajectory frame, almost all internal vectors are represented in whatever coordinate system is used to represent platform position. The trajectory frame must be planet-fixed. The platform body frame is specified relative to arbitrary reference points relative to the platform (spacecraft or test vehicle). Its rotation is a function of time from the trajectory coordinate system specified via dynamics input (file for open loop, callback for closed loop). Orientation of the frame relative to the body is arbitrary, but constant over time. The TDS frame must have a constant rotation and translation from the platform body frame specified at run time. The DEM frame has an arbitrary, but time-constant, rotation and translation with respect to the simulation frame specified at run time. It has the same orientation as sigma0 frame, but is possibly translated. Surface sigma0 has the same arbitrary rotation and translation as DEM frame.

Chen, Curtis W.↗

A CONVENIENT SOLUTION TO GEOMETRIC DISTORTION AND ITS APPLICATION TO PHOEBE'S OBSERVATIONS

A simple but effective approach is proposed for measuring the geometric distortion of a CCD field of view of a ground-based telescope. For three open clusters (M35, M67, and NGC 2324), 425 CCD frames taken by a 1 m telescope at the Yunnan Observatory are used to test this approach. It is found that the geometric distortion pattern depends strongly on the corresponding filter used. The geometric distortion is then used to correct the pixel positions for Phoebe, the ninth satellite of Saturn, and its reference stars imaged in 220 CCD frames taken by the same telescope. The standard deviation of the (O - C; observed minus computed) residuals of Phoebe is significantly improved after correcting the geometric distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Early Results from GLASS-JWST. V: The First Rest-frame Optical Size–Luminosity Relation of Galaxies at z > 7

We present the first rest-frame optical size–luminosity relation of galaxies at z > 7, using the NIRCam imaging data obtained by the GLASS James Webb Space Telescope Early Release Science (GLASS-JWST-ERS) program, providing the deepest extragalactic data of the ERS campaign. Our sample consists of 19 photometrically selected bright galaxies with m F444W ≤ 27.8 at 7 < z < 9 and m F444W < 28.2 at z ~ 9–15. We measure the size of the galaxies in five bands, from rest-frame optical (~4800 Å) to the UV (~1600 Å) based on the Sérsic model, and analyse the size–luminosity relation as a function of wavelength. Remarkably, the data quality of the NIRCam imaging is sufficient to probe the half-light radius r e down to ~100 pc at z > 7. Given the limited sample size and magnitude range, we first fix the slope to that observed for larger samples in rest-frame UV using Hubble Space Telescope samples. The median size r 0 at the reference luminosity M = –21 decreases slightly from rest-frame optical (600 ± 80 pc) to UV (450 ± 130 pc). We then refit the size–luminosity relation allowing the slope to vary. The slope is consistent with β ~ 0.2 for all bands except F150W, where we find a marginally steeper slope of β = 0.53 ± 0.15. The steep UV slope is mainly driven by the smallest and faintest galaxies. If confirmed by larger samples, it implies that the UV size–luminosity relation breaks toward the faint end, as suggested by lensing studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Resolution of the COBE Earth sensor anomaly

Since its launch on November 18, 1989, the Earth sensors on the Cosmic Background Explorer (COBE) have shown much greater noise than expected. The problem was traced to an error in Earth horizon acquisition-of-signal (AOS) times. Due to this error, the AOS timing correction was ignored, causing Earth sensor split-to-index (SI) angles to be incorrectly time-tagged to minor frame synchronization times. Resulting Earth sensor residuals, based on gyro-propagated fine attitude solutions, were as large as plus or minus 0.45 deg (much greater than plus or minus 0.10 deg from scanner specifications (Reference 1)). Also, discontinuities in single-frame coarse attitude pitch and roll angles (as large as 0.80 and 0.30 deg, respectively) were noted several times during each orbit. However, over the course of the mission, each Earth sensor was observed to independently and unexpectedly reset and then reactivate into a new configuration. Although the telemetered AOS timing corrections are still in error, a procedure has been developed to approximate and apply these corrections. This paper describes the approach, analysis, and results of approximating and applying AOS timing adjustments to correct Earth scanner data. Furthermore, due to the continuing degradation of COBE's gyroscopes, gyro-propagated fine attitude solutions may soon become unavailable, requiring an alternative method for attitude determination. By correcting Earth scanner AOS telemetry, as described in this paper, more accurate single-frame attitude solutions are obtained. All aforementioned pitch and roll discontinuities are removed. When proper AOS corrections are applied, the standard deviation of pitch residuals between coarse attitude and gyro-propagated fine attitude solutions decrease by a factor of 3. Also, the overall standard deviation of SI residuals from fine attitude solutions decrease by a factor of 4 (meeting sensor specifications) when AOS corrections are applied.

Sedler, J.↗

Dissociative photoionization of NO across a shape resonance in the XUV range using circularly polarized synchrotron radiation

We report benchmark results for dissociative photoionization (DPI) spectroscopy and dynamics of the NO molecule in the region of the σ* shape resonance in the ionization leading to the NO + (c 3 Π) ionic state. The experimental study combines well characterized extreme ultraviolet (XUV) circularly polarized synchrotron radiation, delivered at the DESIRS beamline (SOLEIL), with ion-electron coincidence 3D momentum spectroscopy. The measured (N + , e) kinetic energy correlation diagrams reported at four discrete photon energies in the extended 23-33 eV energy range allow for resolving the different active DPI reactions and underline the importance of spectrally resolved studies using synchrotron radiation in the context of time-resolved studies where photoionization is induced by broadband XUV attosecond pulses. In the dominant DPI reaction which leads to the NO + (c 3 Π) ionic state, photoionization dynamics across the σ* shape resonance are probed by molecular frame photoelectron angular distributions where the parallel and perpendicular transitions are highlighted, as well as the circular dichroism CDAD(θ e ) in the molecular frame. The latter also constitute benchmark references for molecular polarimetry. The measured dynamical parameters are well described by multichannel Schwinger configuration interaction calculations. Finally, similar results are obtained for the DPI spectroscopy of highly excited NO + electronic states populated in the explored XUV photon energy range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lorentz invariance of basis tensor gauge theory

Basis tensor gauge theory (BTGT) is a vierbein analog reformulation of ordinary gauge theories in which the vierbein field describes the Wilson line. After a brief review of the BTGT, we clarify the Lorentz group representation properties associated with the variables used for its quantization. In particular, we show that starting from an SO(1,3) representation satisfying the Lorentz-invariant U(1,3) matrix constraints, BTGT introduces a Lorentz frame choice to pick the Abelian group manifold generated by the Cartan subalgebra of U(1,3) for the convenience of quantization even though the theory is frame independent. This freedom to choose a frame can be viewed as an additional symmetry of BTGT that was not emphasized before. We then show how an [Formula: see text] permutation symmetry and a parity symmetry of frame fields natural in BTGT can be used to construct renormalizable gauge theories that introduce frame-dependent fields but remain frame independent perturbatively without any explicit reference to the usual gauge field.

Physics↗

Carbon Capture Approaches for Natural Gas Combined Cycle Systems

This study develops ASPEN PLUS simulation models and cost estimates for Natural Gas Combined Cycle plants with CO2 capture. Three approaches for carbon capture are examined: pre-Adv. Combustion Systems, post-Adv. Combustion Systems and oxy-Adv. Combustion Systems. In pre-Adv. Combustion Systems carbon capture, the carbon in the fuel is converted to CO2 and removed before the Adv. Combustion Systems process, whereas in post-Adv. Combustion Systems, the more dilute CO2 is separated from the flue gas at a lower pressure. Oxy-Adv. Combustion Systems technologies use nearly pure oxygen as the oxidant so that the flue gas consists primarily of CO2 and water vapor. Case results are compared with a reference plant based on an 7F frame Adv. Combustion Systems turbine.

Approaches for Natural Gas Combined Cycle Systems↗

Very long baseline interferometry /VLBI/ applications to secular geodynamics and earth strain measurement

An instrumental technique from radio astronomy known as very long baseline interferometry (VLBI) offers significant promise for the solution of the problem of accurate long-distance, three-dimensional surveying and determination of whole earth geodynamical phenomena. The methods of VLBI make it possible for receiving stations to be independently operated at arbitrary separations using extragalactic radio sources as their frame of time-invariant angular reference. Feasibility demonstrations at S-band (13 cm) wavelengths have been performed, and accuracies of a few centimeters for three-dimensional surveying over a short distance (16 km) have been demonstrated. VLBI operation on longer baselines (8400 km) has been performed between Goldstone, California, and Madrid, Spain, in order to develop the capability for determination of universal time variations, in addition to the measurements of this intercontinental baseline. Systems analysis indicates that necessary calibrations can be developed so as to make possible the implementation of a transportable radio interferometer station concept.

Macdoran, P. F.↗

Transformation theory and translation factors in inelastic atomic collisions

It is shown through the use of transformation theory that unique semiclassical atomic scattering states which obey the asymptotic conditions of formal scattering theory can be derived by transforming 'nontraveling' atomic states, ie., states whose coordinate variables are referred to a stationary origin, to frames at rest with respect to the incoming or outgoing particles. An overview of the problem of properly defining such scattering states is presented. The operator which carries out the necessary transformation from inertial to noninertial frames is derived and its properties are discussed. The relation of this transformation operator to the 'translation factor' discussed in the literature is presented. The application of this operator to transform the time-dependent Schroedinger equation from an inertial to a noninertial frame is presented and shown to introduce new terms in the resulting equation. The implications of these new terms to scattering problems are discussed.

Schmid, G. B.↗

Beam’s-eye-view imaging during non-coplanar lung SBRT

Purpose: Beam’s-eye-view (BEV) imaging with an electronic portal imaging device (EPID) can be performed during lung stereotactic body radiation therapy (SBRT) to monitor the tumor location in real-time. Image quality for each patient and treatment field depends on several factors including the patient anatomy and the gantry and couch angles. The authors investigated the angular dependence of automatic tumor localization during non-coplanar lung SBRT delivery. Methods: All images were acquired at a frame rate of 12 Hz with an amorphous silicon EPID. A previously validated markerless lung tumor localization algorithm was employed with manual localization as the reference. From ten SBRT patients, 12 987 image frames of 123 image sequences acquired at 48 different gantry–couch rotations were analyzed. δ was defined by the position difference of the automatic and manual localization. Results: Regardless of the couch angle, the best tracking performance was found in image sequences with a gantry angle within 20° of 250° (δ = 1.40 mm). Image sequences acquired with gantry angles of 150°, 210°, and 350° also led to good tracking performances with δ = 1.77–2.00 mm. Overall, the couch angle was not correlated with the tracking results. Among all the gantry–couch combinations, image sequences acquired at (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) led to the best tracking results with δ = 1.19–1.82 mm. The worst performing combinations were (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) with δ > 3.5 mm. However, 35% (17/48) of the gantry–couch rotations demonstrated substantial variability in tracking performances between patients. For example, the field angle (θ = 70°, ϕ = 10°) was acquired for five patients. While the tracking errors were ≤1.98 mm for three patients, poor performance was found for the other two patients with δ ≥ 2.18 mm, leading to average tracking error of 2.70 mm. Only one image sequence was acquired for all other gantry–couch rotations (δ = 1.18–10.29 mm). Conclusions: Non-coplanar beams with gantry–couch rotation of (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) have the highest accuracy for BEV lung tumor localization. Additionally, gantry angles of 150°, 210°, 250°, and 350° also offer good tracking performance. The beam geometries (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) are associated with substantial automatic localization errors. Overall, lung tumor visibility and tracking performance were patient dependent for a substantial number of the gantry–couch angle combinations studied.

60 APPLIED LIFE SCIENCES↗

Instrument Pointing Capabilities: Past, Present, and Future

This paper surveys the instrument pointing capabilities of past, present and future space telescopes and interferometers. As an important aspect of this survey, we present a taxonomy for "apples-to-apples" comparisons of pointing performances. First, pointing errors are defined relative to either an inertial frame or a celestial target. Pointing error can then be further sub-divided into DC, that is, steady state, and AC components. We refer to the magnitude of the DC error relative to the inertial frame as absolute pointing accuracy, and we refer to the magnitude of the DC error relative to a celestial target as relative pointing accuracy. The magnitude of the AC error is referred to as pointing stability. While an AC/DC partition is not new, we leverage previous work by some of the authors to quantitatively clarify and compare varying definitions of jitter and time window averages. With this taxonomy and for sixteen past, present, and future missions, pointing accuracies and stabilities, both required and achieved, are presented. In addition, we describe the attitude control technologies used to and, for future missions, planned to achieve these pointing performances.

celestial targets↗

Imaging for Hypersonic Experimental Aeroheating Testing (IHEAT) Version 4.0: User Manual

The IHEAT v4.0 software is a data reduction code for global thermography data acquired in the NASA Langley Aerothermodynamics Laboratory (LAL) hypersonic wind tunnels. IHEAT uses red and green color-intensity data from two-dimensional images of wind tunnel models to compute temperatures and heat-transfer rates using a semi-infinite, one-dimensional heat transfer approximation at each image pixel. Multiple automated tools in IHEAT v4.0 decrease the time required to reduce the data from a phosphor thermography wind tunnel run. Data at one or all of the image pixel locations can be exported to computer files for further analysis. The prior version of IHEAT, v3.2, was written in PV-WAVE® (now owned by Rogue Wave® Software) in 1994 and was limited in functionality to fit within the memory constraints of the available computers at the time. IHEAT v4.0 is written in MATLAB® by MathWorks® and contains several new features that leverage the increase in available memory of the current computers. A Piecewise tool permits the user to extract data along a segmented line cut that can follow interesting features in the image better than the single, straight line cuts that were possible with the legacy Length and Profile tools. The new Load Run and Batch tools facilitate batch processing by loading in all of the input files and images for a run at the same time. Load Run permits the user to process the available run images manually, while Batch automatically saves heat transfer data from all of the images based on the analysis previously performed on a single frame. IHEAT v4.0 also can automatically calculate the temporal collapse of reference line cuts from the time history heating data for a run to indicate the appropriate frame to reduce for each run. The IHEAT v4.0 source code was compiled into a standalone executable file that can be accessed remotely from several computers with different operating systems, simultaneously. The software is run through the MATLAB® Compiler Runtime engine, and therefore, IHEAT does not require a software license to run. Any software commands executed in the IHEAT v4.0 code will not affect other similar applications running on the same machine. Similarly, changes to the parent software do not affect a compiled code. These features of IHEAT v4.0 are improvements over the legacy v3.2 code, which required regular maintenance to avoid losing functionality as the PVWAVE ® programming language was upgraded.

Mason, Michelle L.↗

Comparison of computer- and human-derived coronary angiographic end-point measures for controlled therapy trials

The Cholesterol Lowering Atherosclerosis Study, a randomized angiographic clinical trial, demonstrated the beneficial effect of niacin/colestipol plus diet therapy on coronary atherosclerosis. Outcome was determined by panel-based estimates (viewed in both still and cine modes) of percent stenosis severity and change in native artery and bypass graft lesions. Computer-based quantitative coronary angiography (QCA) was also used to measure lesion and bypass graft stenosis severity and change in individual frames closely matched in orientation, opacification, and cardiac phase. Both methods jointly evaluated 350 nonoccluded lesions. The correlation between QCA and panel estimates of lesion size was 0.70 (p less than 0.0001) and for change in lesion size was 0.28 (p = 0.002). Agreement between the two methods in classifying lesion changes (i.e., regression, unchanged, or progression) occurred for 60% (210 of 350) of the lesions kappa +/- SEM = 0.20 +/- 0.05, p less than 0.001). The panel identified 442 nonoccluded lesions for which QCA stenosis measurements could not be obtained. Lesions not measurable by QCA included those with stenosis greater than 85% that could not be reliably edge tracked, segments with diffuse or ecstatic disease that had no reliable reference diameter, and segments for which matched frames could not be located. Seventy-nine lesions, the majority between 21% and 40% stenosis, were identified and measured by QCA but were not identified by the panel. This comparison study demonstrates the need to consider available angiographic measurement methods in relation to the goals of their use.

NASA Center JPL↗

Comparison of z-known GRBs with the Main Groups of Bright BATSE Events

The small reference sample of six BATSE gamma-ray bursts with known redshifts from optical afterglows is compared with a comparison group of the 218 brightest BATSE bursts. These two groups are shown to be consistent both with respect to the distributions of the spectral peak parameter in the observer's frame and also with respect to the distributions of the frame-independent cosmological invariant parameter (CIP). Using the known values of the redshifts z for the reference sample, the rest-frame distribution of spectral parameters is built. The de-redshifted distribution of the spectral parameters of the reference sample is compared with distribution of these parameters for the comparison group after de-redshifting by the factor 1/(1+z), with z a free parameter. Requiring consistency between these two distributions produces a collective estimation of the best fitting redshifts z for the comparison group, z=1.8--3.6. These values can be considered as the average cosmological redshift of the sources of the brightest BATSE bursts. The most probable value of the peak energy of the spectrum in the rest frame is 920 keV, close to the rest mass of an electron-positron pair.

Mitrofanov, Igor G.↗

Reconfigurable assembly work station

A reconfigurable autonomous workstation includes a multi-faced superstructure including a horizontally-arranged frame section supported on a plurality of posts. The posts form a plurality of vertical faces arranged between adjacent pairs of the posts, the faces including first and second faces and a power distribution and position reference face. A controllable robotic arm suspends from the rectangular frame section, and a work table fixedly couples to the power distribution and position reference face. A plurality of conveyor tables are fixedly coupled to the work table including a first conveyor table through the first face and a second conveyor table through the second face. A vision system monitors the work table and each of the conveyor tables. A programmable controller monitors signal inputs from the vision system to identify and determine orientation of the component on the first conveyor table and control the robotic arm to execute an assembly task.

42 ENGINEERING↗

Bridging the gap between LCA, LCC and CBA as sustainability assessment tools

Increasing interest in sustainability has led to the development of sustainability assessment tools such as Life Cycle Analysis (LCA), Life Cycle Costing (LCC) and Cost–Benefit Analysis (CBA). Due to methodological disparity of these three tools, conflicting assessment results generate confusion for many policy and business decisions. In order to interpret and integrate assessment results, the paper provides a framework that clarifies the connections and coherence between the included assessment methodologies. Building on this framework, the paper further focuses on key aspects to adapt any of the methodologies to full sustainability assessments. Aspects dealt with in the review are for example the reported metrics, the scope, data requirements, discounting, product- or project-related and approaches with respect to scarcity and labor requirements. In addition to these key aspects, the review shows that important connections exist: (i) the three tools can cope with social inequality, (ii) processes such as valuation techniques for LCC and CBA are common, (iii) Environmental Impact Assessment (EIA) is used as input in both LCA and CBA and (iv) LCA can be used in parallel with LCC. Furthermore, the most integrated sustainability approach combines elements of LCA and LCC to achieve the Life Cycle Sustainability Assessment (LCSA). The key aspects and the connections referred to in the review are illustrated with a case study on the treatment of end-of-life automotive glass. - Highlights: • Proliferation of assessment tools creates ambiguity and confusion. • The developed assessment framework clarifies connections between assessment tools. • Broadening LCA, key aspects are metric and data requirements. • Broadening LCC, key aspects are scope, time frame and discounting. • Broadening CBA, focus point, timespan, references, labor and scarcity are key.

54 ENVIRONMENTAL SCIENCES↗

Four dimensional studies in earth space

A system of reference which is directly related to observations, is proposed for four-dimensional studies in earth space. Global control network and polar wandering are defined. The determination of variations in the earth's gravitational field with time also forms part of such a system. Techniques are outlined for the unique definition of the motion of the geocenter, and the changes in the location of the axis of rotation of an instantaneous earth model, in relation to values at some epoch of reference. The instantaneous system referred to is directly related to a fundamental equation in geodynamics. The reference system defined would provide an unambiguous frame for long period studies in earth space, provided the scale of the space were specified.

Mather, R. S.↗