Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Signals from fluorescent materials on the surface of silicon micro-strip sensors

For the High-Luminosity Upgrade of the Large Hadron Collider at CERN, the ATLAS Inner Detector will be replaced with a new, all-silicon tracker (ITk). In order to minimise the amount of material in the ITk, circuit boards with readout electronics will be glued onto the active area of the sensor. Several adhesives, investigated to be used for the construction of detector modules, were found to become fluorescent when exposed to UV light. These adhesives could become a light source in the high-radiation environment of the ATLAS detector. The effect of fluorescent material covering the sensor surface in a high-radiation environment has been studied for a silicon micro-strip sensor using a micro-focused X-ray beam. By positioning the beam parallel to the sensor surface and pointing it both inside the sensor and above the sensor surface inside the deposited glue, the sensor responses from direct hits and fluorescence can be compared with high precision. This contribution presents a setup to study the susceptibility of silicon strip sensors to light contamination from fluorescent materials and shows their impact on the noise and fake signal rate of a sensor operated in a high-radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an array of liquid-scintillator-based bar detectors: SABRE

We present that an array of neutron detectors based on liquid scintillator technology has been developed for nuclear reaction studies, in particular measurements with radioactive ion beams (RIBs). Reaction measurements with RIBs often involve low reaction yields and high gamma-induced backgrounds, which requires high solid angle coverage, high efficiency, and background reduction capability. The kinematics of the reaction neutrons require energy and position determination with good resolution, but preferably without a large number of readouts to minimize cost. To address these requirements, the Scintillation Array of Bars for Reaction Experiments (SABRE) consists of five 12” long, 2” diameter bar detectors filled with organic liquid scintillator and capped at both ends with individually read-out superbialkali photomultiplier tubes (PMTs). Finally, in-house purification of the scintillator mixtures resulted in improved light collection. Discussion of the liquid scintillator development and the design and commissioning of SABRE will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and test of the Mu2e undoped CsI+SiPM crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating neutrino-less conversion of a negative muoninto an electron in the field of an aluminum nucleus. The calorimeter plays an important role in providing a fast trigger filter,excellent particle identification and a seeding for track reconstruction. Its requirements are to provide an energy (timing) resolutionbetter than 10% (0.5 ns) and a position resolution below 1 cm, for 100 MeV electrons. The calorimeter consists of two disks, eachone made of 674 un-doped CsI crystals readout by two large area arrays of 23 UV-extended SiPMs of 66 mm2dimensions.A large scale prototype (Module-0) has been constructed and tested with an electron beam in the energy range between 60 and 120MeV at the BTF of Frascati National Laboratories. Results demonstrated that this calorimeter satisfies the Mu2e requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the LaBr 3 (Ce) detector array at the National Superconducting Cyclotron Laboratory

The timing and energy resolution properties of LaBr 3 (Ce) scintillators are well suited for use in γγ fast-timing experiments. Here, using standard 60 Co, 88 Y, and 152 Eu sources, the 16-element array of 1.5 inch by 1.5 inch right-cylindrical LaBr 3 (Ce) detectors and the associated readout electronics at the National Superconducting Cyclotron Laboratory were commissioned by measuring the lifetimes of excited states and the angular correlations of γ rays emitted in cascade. Excited-state lifetimes in 152 Sm and 152 Gd were measured using the exponential slope of the decay and a method based on the centroids of time-difference spectra. Results for the lifetimes are consistent with the well-known literature values which cover a range from a few picoseconds to several nanoseconds. Finally, the γγ angular correlations for the 4 + → 2 + → 0 + cascade in 60 Ni and the 3 - → 2 + → 0 + cascade in 88 Sr were measured and shown to agree with GEANT4 simulations that take into account the expected angular correlations within the cascades as well as the geometry of the array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronics of the energy plane of the NEXT-White detector

This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterráneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit -1 in the chain of 214 Bi . All the components and materials have been carefully screened to assure a low radioactivity level and at the same time meet the required front-end electronics specifications. In order to reduce low frequency noise effects and enhance detector safety a grounded cathode connection has been used for the PMTs. This implies an AC-coupled readout and baseline variations in the PMT signals. A detailed description of the electronics and a novel approach based on a digital baseline restoration to obtain a linear response and handle AC coupling effects is presented. The final PMT channel design has been characterized with linearity better than 0.4% and noise below 0.4 mV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗

Development of a neutron spectrometer utilizing rubberized Eu:LiCAF wafers

A portable ten-layer neutron spectrometer has been developed using a novel material, LiCAF. The spectrometer consists of rubber matrix wafers with embedded europium doped lithium calcium aluminum uoride (Eu:LiCAF) crystals and crosshatched wave shifting fibers (WSF). Layers of high density polyethylene (HDPE) separating each Eu:LiCAF wafer serve as neutron moderating material. Neutrons entering the spec- trometer react in the Eu:LiCAF crystal, creating scintillation photons. The photons travel down the WSFs to silicon photomultipliers (SiPMs) that convert the photons to an electrical signal. Custom electronics are used to gather, amplify, process, and readout the signal. A library of several neutron response curves was created in Geant4 and MCNP. The experimental output of the spectrometer was unfolded using a maximum entropy algorithm, MAXED. The spectrometer was tested using two separate DD generators. These two tests resulted in unfolded neutron spectra with average neutron energies of 2.71 and 2.78 MeV and chi-squared values of 0.88 and 1.51 χ 2 /D.O.F. respectively, when fit to a 2.45 MeV monoenergetic energy spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of deconvolution to recover frequency-domain multiplexed detector pulses

Multiplexing of radiation detectors reduces the number of readout channels, which in turn reduces the number of digitizer input channels for data acquisition. We recently demonstrated frequency domain multiplexing (FDM) of pulse mode radiation detectors using a resonator that converts the detector signal into a damped sinusoid by convolution. The detectors were given unique “tags” by the oscillation frequency of each resonator. The charge collected and the time-of-arrival of the detector pulse were estimated from the corresponding resonator output in the frequency domain. In this paper, we demonstrate a new method to recover the detector pulse from the damped sinusoidal output by deconvolution. Deconvolution converts the frequency-encoded detector signal back to the original detector pulse. We have developed a new prototype FDM system to multiplex organic scintillators based on convolution and deconvolution. Using the new prototype, the charge collected under the anode pulse can be estimated from the recovered pulse with an uncertainty of about 4.4 keVee (keV electron equivalent). The time-of-arrival can be estimated from the recovered pulse with an uncertainty of about 102 ps. We also used a CeBr3 inorganic scintillator to measure the Cs-137 gamma spectrum using the recovered pulses and found a standard deviation of 13.8 keV at 662 keV compared to a standard deviation of 13.5 keV when the original pulses were used. Coincidence measurements with Na-22 using the deconvolved pulses resulted in a timing uncertainty of 617 ps compared to an uncertainty of 603 ps using the original pulses. Pulse shape discrimination was also performed using Cf-252 source and EJ-309 organic scintillator pulses recovered by deconvolution. In conclusion, a figure of merit value of 1.08 was observed when the recovered pulses were used compared to 1.2 for the original pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing and synchronization of the DUNE neutrino detector

The DUNE neutrino experiment far detector has a fiducial mass of 40 kt. The O(1 M) readout channels are distributed over the 4 x 10kt modules and need to be synchronized to O(10 ns) with a reliable, simple, affordable system. For the majority of channels a simple DC-balanced protocol is used, with clock and synchronization information encoded on the same fibre. The remaining channels use “White Rabbit” (IEEE-1588). Small scale tests show a timing jitter of <100 ps. The DUNE timing system has been successfully prototyped at the ProtoDUNE-SP detector at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADGET: a Gaseous Detector with Germanium Tagging

The Gaseous Detector with Germanium Tagging (GADGET) is a new detection system devoted to the measurement of weak, low-energy β-delayed proton decays relevant for nuclear astrophysics studies. It is comprised of a new gaseous Proton Detector equipped with a Micromegas readout for charged particle detection, surrounded by the existing Segmented Germanium Array (SeGA) for the high-resolution detection of the prompt γ-rays. Here in this work we describe in detail for the first time the design, construction, and operation of the GADGET system, including performance of the Proton Detector. We present the results of a recent commissioning experiment performed with 25 Si beam at the National Superconducting Cyclotron Laboratory (NSCL). GADGET provided low-background, low-energy β-delayed proton detection with efficiency above 95%, and relatively good efficiency for proton-gamma coincidences (2.7% at 1.37 MeV).

β-delayed proton emission↗

A simulation model of front-end electronics for high-precision timing measurements with low-gain avalanche detectors

Here, we report simulation results of a study aiming to optimize parameters of a detector that uses low-gain avalanche detectors (LGAD) for high-precision timing measurements. The detector is assumed to be composed of a 50μm LGAD sensor coupled to front-end readout electronics which is used to measure the time of arrival of minimum ionizing particles. The simulation includes modeling of signal fluctuations in the LGAD sensor, variations of the analog bandwidth and signal-to-noise ratio (SNR) of the front-end electronics, time bin quantization, and radiation damage of the LGAD sensors. Two approaches to measure the timestamp are considered: leading edge and constant fraction. Simulated LGAD pulses before irradiation, and after irradiation with neutron fluences of 5×10 14 n/cm 2 and 1×10 15 n/cm 2 , are studied. The time resolution for a 50μm LGADs was found to be 35 ps for front-end electronics bandwidths larger than 350 MHz and SNRs larger than 30. The time resolution at SNR of 30 for fluences of 5×10 14 n/cm 2 and 1×10 15 n/cm 2 were found to be 31 ps and 37 ps, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high precision calibration of the nonlinear energy response at Daya Bay

A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment’s antineutrino detectors is observed. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by γ calibration points from deployed and naturally occurring radioactive sources, the β spectrum from 12 B decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. With this beind said, less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of a semiconductor-based atmospheric radioxenon detection system

A prototype radioxenon detection system for beta–gamma coincidence measurements has been designed using a PIPSBox and a pair of coplanar CdZnTe (CZT) detectors. Coincidence events are identified in real-time using a Field-Programmable Gate Array (FPGA). The measurement of 131m Xe and studies on electron backscatter and memory effect in the PIPSBox have been presented previously; this paper details the measurement of 133/133m Xe, 135 Xe, and background. Here, absolute efficiencies were determined, regions of interest were defined, and Minimum Detectable Concentrations (MDC) for all four radioxenon isotopes were calculated. When neglecting interferences between the radioxenons, the prototype system has an estimated MDC of 0.61 ± 0.15 mBq/m 3 for 133 Xe when using gas processing parameters associated with Xenon International, satisfying the CTBTO requirement for sensitivity of ≤1 mBq/m 3 for 133 Xe. Simulation suggests that by increasing number of CZT detectors used by a factor of 16, the MDCs of the system can be improved by a factor of 2-3. The design shows great promise for future improvement and expansion due to its exceptional energy resolution, high background rejection rate, room temperature operation, minimal memory effect, and simple readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Micromegas Vertex Tracker

The Micromegas Vertex Tracker was designed to improve upon the tracking capabilities of the baseline design of the CLAS12 spectrometer in Hall~B at Jefferson Laboratory. A Barrel Micromegas Tracker made with six concentric cylinders, each made of three 120$^\circ$-sector tiles, surrounds the Silicon Vertex Tracker, and a Forward Micromegas Tracker composed of 6 disks is placed 30~cm downstream of the liquid-hydrogen target. Both trackers sit in a 5~T solenoid magnetic field. All Micromegas elements are based on resistive technology to withstand luminosities up to $10^{35}$~cm$^{-2}$s$^{-1}$, as well as on bulk technology to enforce gain uniformity and mechanical robustness. Due to the high magnetic field, dedicated electronics have been designed and displaced $\sim$2~m away from the detectors. The electronics readout is based on the DREAM ASICs that allow sustained operation up to 20~kHz trigger rate at the maximum luminosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Forward Time-of-Flight system

The Forward Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system is positioned at distances in the range from 6.2 m to 7.2 m from the beam–target interaction point and spans laboratory polar angles from 5 deg → 45 deg and nearly the full azimuth. The system consists of 540 individual scintillation counters with double-ended readout that range in length from 17 cm to 426 cm of discrete widths of 6 cm, 15 cm, and 22 cm, and of discrete thicknesses of 5 cm and 6 cm. We see the effective counter time resolution for passing charged particles varies from 50 ps for the shortest counters at small angles to 200 ps for the longest counters at large angles. The detectors are part of the forward-angle particle identification system for CLAS12 during offline event reconstruction and are a component of the online data acquisition trigger to select final state event topologies with forward-going charged particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strip sensor performance in prototype modules built for ATLAS ITk

ATLAS experiment is preparing an upgrade of its detector for High-Luminosity LHC (HL-LHC) operation. The upgrade involves installation of the new all-silicon Inner Tracker (ITk). In the context of the ITk preparations, more than 80 strip modules were built with prototype barrel sensors. They were tested with electrical readout on a per-channel basis. In general, an excellent performance was observed, consistent with previous ASIC-level and sensor-level tests. However, the lessons learned included two phenomena important for the future phases of the project. First was the need to store and test the modules in a dry environment due to humidity sensitivity of the sensors. The second was an observation of high noise regions for 2 modules. The high noise regions were tested further in several ways, including monitoring the performance as a function of time and bias voltage. Additionally, direct sensor-level tests were performed on the affected channels. The inter-strip resistance and bias resistance tests showed low values, indicating a temporary loss of the inter-strip isolation. A subsequent recovery of the noise performance was observed. Here we present the test details, an analysis of how the inter-strip isolation affects the module noise, and the relationship with sensor-level quality control tests.

47 OTHER INSTRUMENTATION↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗