Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ray tracing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

A diamond anvil cell for x-ray fluorescence measurements of trace elements in fluids at high pressure and high temperature

We present a new diamond anvil cell (DAC), hereafter called the fluoX DAC, dedicated for x-ray fluorescence (XRF) analysis of trace elements in fluids under high pressure and high temperature to 10 GPa and 1273 K at least. This new setup has allowed measurement of Rb, Sr, Y, Zr, with concentrations of 50 ppm to 5.6 GPa and 1273 K. The characteristics of the fluoX DAC consist in an optimized shielding and collection geometry in order to reduce the background level in XRF spectrum. Consequently, minimum detection limits of 0.3 ppm were calculated for the abovementioned elements in this new setup. This new DAC setup coupled to the hard x-rays focusing beamline ID22 (ESRF, France) offers the possibility to analyze in situ at high pressure and high temperature, ppm level concentrations of heavy elements, rare earth elements, and first transition metals, which are of prime importance in geochemical processes. The fluoX DAC is also suitable to x-ray diffraction over the same high pressure-temperature range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical ray paths in a quasi-periodic waveguide or a multipass cavity with smoothly varying properties

Ray paths in a quasi-periodic optical system (waveguide of cavity) with smoothly varying properties have been constructed along the ray path. The ray-transfer matrix is constructed for a large number of ray paths; it has been shown that the conventional stability condition (the modulus of the ray-transfer matrix trace for a ray path is smaller than two) does not ensure the boundedness of the beam path after a large number of paths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rf-sputtered cadmium sulfide 'thin crystals'

RF-sputtered CdS thin films structural and electrical characteristics from X ray diffractometer tracings, reflection electron diffraction and X ray double crystal spectrometry

Lagnado, I.↗

Ab Initio Molecular Dynamics of Uranium Incorporated in Goethite (α-FeOOH): Interpretation of X-ray Absorption Spectroscopy of Trace Polyvalent Metals

Incorporation of economically or environmentally consequential polyvalent metals into iron (oxyhydr)oxides has applications in environmental chemistry, remediation, and materials science. A primary tool for characterizing the local coordination environment of such metals, and therefore building models to predict their behavior, is extended X-ray absorption fine structure spectroscopy (EXAFS). Accurate structural information can be lacking, yet is required to constrain and inform data interpretation. In this regard, ab initio molecular dynamics (AIMD) was used to calculate the local coordination environment of minor amounts of U incorporated in the structure of goethite (α-FeOOH). U oxidation state (VI, V, and IV) and charge compensation scheme (CCS) were varied. Simulated trajectories were used to calculate the U LIII-edge EXAFS function and fit experimental EXAFS data for U incorporated into goethite under reducing conditions. Calculations that closely matched the U EXAFS of the well-characterized mineral uraninite (UO2), and constrained the S02 parameter to be 0.909, validated the approach. The results for the U-goethite system indicated that U(V) substituted for structural Fe(III) in octahedral uranate coordination. Charge balance was achieved by the loss of one structural proton coupled to injection of one electron into the solid (–1 H+, + 1 e-). The ability of AIMD to model higher-energy states thermally accessible at room temperature is particularly relevant for protonated systems such as goethite, where proton transfers between adjacent octahedra had a dramatic effect on the calculated EXAFS. Vibrational effects as a function of temperature were also estimated using AIMD, allowing separate quantification of thermal and configurational disorder. In summary, coupling AIMD structural modeling and EXAFS experiments enables modeling of the redox behavior of polyvalent metals that are incorporated in conductive materials such as iron (oxyhydr)oxides, with applications over a broad swath of chemistry and materials science.

36 MATERIALS SCIENCE↗

RSPECT: A PROSPECT-based model incorporating the real structure of rice leaves

Radiative transfer models (RTMs) describe how light is absorbed, scattered, and transmitted within leaves by simulating mechanistic light propagation processes. The PROSPECT model is based on measurable parameters (the leaf biochemical content) and a non-measurable parameter (the leaf anatomical structure represented by the leaf structure parameter (N)). The effect of N on the optical properties of leaves has been investigated through a number of local and global sensitivity analyses. Other studies have directly evaluated the effect of the leaf anatomical structure on spectral reflectance, particularly in the near infrared region. However, the relationship between N and the anatomical structure is unclear. Here, in this study, we leveraged eLeaf, a ray tracing-based 3D rice leaf simulator, to establish relationships between leaf anatomical features and spectral properties, enabling us to replace N in the PROSPECT-4 model with measurable leaf anatomical parameters and develop the RSPECT model. The leaf thickness at minor vein, leaf thickness at bulliform cells, mesophyll thickness at minor vein, and distance between two minor veins could be used to predict N effectively. The RSPECT model achieved spectral simulation accuracy comparable to PROSPECT-4 and was more suitable for parameter inversion of the physical and chemical properties of rice leaves, with relative root mean square errors of 7.4% for chlorophyll content, 5.6% for equivalent water thickness, and 7.5% for dry matter content. In conclusion, RSPECT improves radiative transfer modeling by integrating measurable anatomical features and provides a framework for extending this approach to other vegetation types.

hyperspectral↗

DYNAMICS AND MAGNETIZATION IN GALAXY CLUSTER CORES TRACED BY X-RAY COLD FRONTS

Cold fronts (CFs)-density and temperature plasma discontinuities-are ubiquitous in cool cores of galaxy clusters, where they appear as X-ray brightness edges in the intracluster medium, nearly concentric with the cluster center. We analyze the thermodynamic profiles deprojected across core CFs found in the literature. While the pressure appears continuous across these CFs, we find that all of them require significant centripetal acceleration beneath the front. This is naturally explained by a tangential, nearly sonic bulk flow just below the CF, and a tangential shear flow involving a fair fraction of the plasma beneath the front. Such shear should generate near-equipartition magnetic fields on scales {approx}<50pc from the front and could magnetize the entire core. Such fields would explain the apparent stability of cool core CFs and the recently reported CF-radio minihalo association.

79 ASTRONOMY AND ASTROPHYSICS↗

The history of metal enrichment traced by X-ray observations of high-redshift galaxy clusters

ABSTRACT We present the analysis of deep X-ray observations of 10 massive galaxy clusters at redshifts 1.05 < z < 1.71, with the primary goal of measuring the metallicity of the intracluster medium (ICM) at intermediate radii, to better constrain models of the metal enrichment of the intergalactic medium. The targets were selected from X-ray and Sunyaev–Zel’dovich effect surveys, and observed with both the XMM–Newton and Chandra satellites. For each cluster, a precise gas mass profile was extracted, from which the value of r500 could be estimated. This allows us to define consistent radial ranges over which the metallicity measurements can be compared. In general, the data are of sufficient quality to extract meaningful metallicity measurements in two radial bins, r < 0.3r500 and 0.3 < r/r500 < 1.0. For the outer bin, the combined measurement for all 10 clusters, Z/Z⊙ = 0.21 ± 0.09, represents a substantial improvement in precision over previous results. This measurement is consistent with, but slightly lower than, the average metallicity of 0.315 solar measured at intermediate-to-large radii in low-redshift clusters. Combining our new high-redshift data with the previous low-redshift results allows us to place the tightest constraints to date on models of the evolution of cluster metallicity at intermediate radii. Adopting a power-law model of the form Z ∝ (1 + z)γ, we measure a slope $\gamma = -0.5^{+0.4}_{-0.3}$, consistent with the majority of the enrichment of the ICM having occurred at very early times and before massive clusters formed, but leaving open the possibility that some additional enrichment in these regions may have occurred since a redshift of 2.

79 ASTRONOMY AND ASTROPHYSICS↗

EVOLUTION OF THE RADIO-X-RAY COUPLING THROUGHOUT AN ENTIRE OUTBURST OF AQUILA X-1

The 2009 November outburst of the neutron star X-ray binary Aquila X-1 (Aql X-1) was observed with unprecedented radio coverage and simultaneous pointed X-ray observations, tracing the radio emission around the full X-ray hysteresis loop of the outburst for the first time. We use these data to discuss the disk-jet coupling, finding the radio emission to be consistent with being triggered at state transitions, both from the hard to the soft spectral state and vice versa. Our data appear to confirm previous suggestions of radio quenching in the soft state above a threshold X-ray luminosity of {approx}10% of the Eddington luminosity. We also present the first detections of Aql X-1 with very long baseline interferometry, showing that any extended emission is relatively diffuse and consistent with steady jets rather than arising from discrete, compact knots. In all cases where multi-frequency data were available, the source radio spectrum is consistent with being flat or slightly inverted, suggesting that the internal shock mechanism that is believed to produce optically thin transient radio ejecta in black hole X-ray binaries is not active in Aql X-1.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent advances in analysis of trace elements in environmental samples by X-ray based techniques (IUPAC Technical Report)

Trace elements analysis is a foundational challenge in environmental sciences. Scientists measure trace elements in environmental media in order to assess the quality and safety of ecosystems and to quantify the burden of anthropogenic pollution. Among the available analytical techniques, X-ray based methods are particularly powerful, as they can quantify trace elements in situ . Chemical extraction is not required, as is the case for many other analytical techniques. In the last few years, the potential for X-ray techniques to be applied in the environmental sciences has dramatically increased due to developments in laboratory instruments and synchrotron radiation facilities with improved sensitivity and spatial resolution. In this report, we summarize the principles of the X-ray based analytical techniques most frequently employed to study trace elements in environmental samples. We report on the most recent developments in laboratory and synchrotron techniques, as well as advances in instrumentation, with a special attention on X-ray sources, detectors, and optics. Lastly, we inform readers on recent applications of X-ray based analysis to different environmental matrices, such as soil, sediments, waters, wastes, living organisms, geological samples, and atmospheric particulate, and we report examples of sample preparation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High frequency scattering from trihedral corner reflectors and other benchmark targets - SBR versus experiment

A general method for calculating the radar cross section (RCS) from a three-dimensional target is described. The target is first constructed by using a solid-geometry-modeling computer-aided design (CAD) package. Following the shooting and bouncing ray (SBR) method, a very dense grid of rays is launched from the incident direction toward the target. Each ray is traced according to the geometrical optics theory including the effect of ray tube divergence, polarization, and material reflection coefficient. At the point where the ray exits the target, a physical optics-type integration is performed to obtain the scattered far fields. This method is tested using several simple examples involving interaction among plates, cylinders, and spheres. The theoretical results are generally in good agreement with measured data.

Baldauf, John↗

The Development of the Chandra X-Ray Observatory

The Chandra X-Ray Observatory traces its origins almost to the beginning of the field of X-Ray astronomy. We will present the history of the development of this Great Observatory from the perspective of the Project Scientist.

Weisskopf, Martin C.↗

Trace element abundance determinations by Synchrotron X Ray Fluorescence (SXRF) on returned comet nucleus mineral grains

Trace element analyses were performed on bulk cosmic dust particles by Proton Induced X Ray Emission (PIXE) and Synchrotron X Ray Fluorescence (SXRF). When present at or near chondritic abundances the trace elements K, Ti, Cr, Mn, Cu, Zn, Ga, Ge, Se, and Br are presently detectable by SXRF in particles of 20 micron diameter. Improvements to the SXRF analysis facility at the National Synchrotron Light Source presently underway should increase the range of detectable elements and permit the analysis of smaller samples. In addition the Advanced Photon Source will be commissioned at Argonne National Laboratory in 1995. This 7 to 8 GeV positron storage ring, specifically designed for high-energy undulator and wiggler insertion devices, will be an ideal source for an x ray microprobe with one micron spatial resolution and better than 100 ppb elemental sensitivity for most elements. Thus trace element analysis of individual micron-sized grains should be possible by the time of the comet nucleus sample return mission.

Flynn, G. J.↗

Cosmic ray particle dosimetry and trajectory tracing

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.

Cruty, M. R.↗

Wave-current interaction study in the Gulf of Alaska for detection of eddies by synthetic aperture radar

High resolution Esa Remote Sensing Satellite-1 (ERS-1) Synthetic Aperture Radar (SAR) images are used to detect a mesoscale eddy. Such features limit dispersal of pollock larvae and therefore likely influence recruitment of fish in the Gulf of Alaska. During high sea states and high winds, the direct surface signature of the eddy was not clearly visible, but the wave refraction in the eddy area was observed. The rays of the wave field are traced out directly from the SAR image. The ray pattern gives information on the refraction pattern and on the relative variation of the wave energy along a ray through wave current interaction. These observations are simulated by a ray-tracing model which incorporates a surface current field associated with the eddy. The numerical results of the model show that the waves are refracted and diverge in the eddy field with energy density decreasing. The model-data comparison for each ray shows the model predictions are in good agreement with the SAR data.

Liu, Antony K.↗

X-ray follow-up observations of unidentified VHE {gamma}-ray sources

A large fraction of the recently discovered Galactic Very High Energy (VHE) source population remains unidentified to date. VHE {gamma}-ray emission traces high energy particles in these sources, but for example in case of hadronic processes also the gas density at the emission site. Moreover, the particles have sufficiently long lifetimes to be able to escape from their acceleration sites. Therefore, the {gamma}-ray sources or at least the areas of maximum surface brightness are in many cases spatially offset from the actual accelerators. A promising way to identify the objects in which the particles are accelerated seems to be to search for emission signatures of the acceleration process (like emission from shock-heated plasma). Also the particles themselves (through primary or secondary synchrotron emission) can be traced in lower wavebands. Those signatures are best visible in the X-ray band, and current X-ray observatories are well suited to conduct such follow-up observations. Some aspects of the current status of these investigations are reviewed.

79 ASTRONOMY AND ASTROPHYSICS↗

Penetration of the LCLS Injector Shield Wall at Sector 20

Penetrations through the LCLS injector shield wall are needed for the alignment of the accelerator, a diagnostic laser beam and utilities, and are shown in figure 1. The 1-inch diameter LCLS injector beam tube is blocked by the PPS stopper when the injector side of the wall is occupied. The two 3-inch diameter penetrations above and to the left of the beam tube are used by Precision Alignment and will be open only during installation of the injector beamline. Additional 3-inch diameter penetrations are for laser beams which will be used for electron beam diagnostics. These will not be plugged when the injector occupied. Other penetrations for the RF waveguide and other utilities are approximately 13-inch from the floor and as such are far from the line-of-sight of any radiation sources. The waveguide and utility penetrations pass only through the thicker wall as shown in the figure. The principal issue is with the two laser penetrations, since these will be open when the linac is operating and people are in the LCLS injector area. A principal concern is radiation streaming through the penetrations due to direct line-of sight of the PEP-2 lines. To answer this, fans of rays were traced through the 3-inch diameter laser penetrations as shown in Figures 2 and 3. Figure 2 gives the top view of the shield walls, the main linac and PEP-2 lines, and the ray-fans. The fans appear to originate between the walls since their angular envelope is defined by the greatest angle possible when rays are just on the 3-inch diameter at the inner most and outermost wall surfaces. The crossovers of all possible rays lie half way between these two surfaces. As the end-on view of Figure 3 clearly shows, there is no direct line-of-sight through the laser penetrations of the PEP-2 or linac beamlines.

43 PARTICLE ACCELERATORS↗