Further Analyses of the Unburied Goiania Accident Packages - 19161

In 1987, in the city of Goiania, Brazil, a derelict teletherapy machine was disassembled by scavengers and Cs-137 was released in the environment, unleashing the biggest radiological accident in Brazil. During the 15 days before the accident was acknowledged, some contaminated materials were sold and delivered to recycling factories in a few cities in the state of Sao Paulo, Brazil, in the form of metal scrap and recycled paper bales. The contaminated material was then collected, the metal scrap was conditioned in forty-three 200-liter drums, and the paper bales were stored in fifty 1.6 cubic meter steel boxes at the interim storage of the Nuclear and Energy Research Institute (IPEN), in the city of Sao Paulo, and there remained ever since. In 2017, 30 years later, initial analyses were performed at a sample of these boxes, checking for their activity, weight, and incongruences between the original values recorded at the time of collection and the measurement results 30 years later. The results indicated that none of the boxes checked were close to the clearance limit and that, without any sort of treatment, this radioactive waste should be stored for at least 150 years more. Visual inspection could not be performed at that time. Nowadays, some of the boxes were opened and samples from the contaminated material inside were taken for analysis. The main objective of this work is to report the results from the evaluation of the physical state of this material. After these analyses, the treatment options for volume reduction that were previously proposed were reviewed, and the method that best suits the current characteristics of the waste was chosen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Severe accident: hardening of standards and qualification requirements for nuclear pressure transmitters - 319

Nuclear power stations are designed according to the nuclear safety principle: the achievement of proper operating conditions, prevention of accidents or mitigation of accident consequences, resulting in protection of workers, the public and the environment from undue radiation hazards. This principle is applicable from the design to the dismantling of the power station, including normal and accident (and post-accident) operation. To take into account the world experience (incident or accident as Fukushima), international safety authorities recommends to reinforce safety functions and qualification requirements level. Concerning the instrumentation, devices like sensors are mainly impacted by the following constraint improvements: - Radiation resistance in normal and accident conditions: - Higher total dose; - Dose Rate; - Nature of radiation; - Pressure and Temperature profile in terms of: - Magnitude of pressure and / or temperature (higher); - Duration of higher constraints (longer). All these specifications induce: - The creation of a new qualification level - Severe Accident (SA) or equivalent; - An impact on the sensor technology to improve the resistance to harsh environment. Finally, the paper will present in details the evolution of the requirements and will sum up the advantages and disadvantages of different technologies to meet the severe accident conditions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Secondary neutron yields from thick-target GCR accelerator experiments - 25434

This work overviews recent experiments conducted at the NASA Space Radiation Laboratory which sought to experimentally verify model predictions of an optimal spacecraft shielding thickness and provide data which can be used to quantify uncertainties in the physics models within the standard particle transport codes which presently, in some places, poorly predict data and whose results can vary significantly from code to code. Now that the multi-year experiment campaign is complete, some of the overarching trends in the data can be studied; though this work only provides a cursory look at these overarching trends. A small set of the neutron yields measured in these experiments are showcased here. The experiment employed two thick targets along a beamline to emulate the walls of a spacecraft being bombarded by galactic cosmic rays. Time-of-flight techniques were used to characterize neutrons produced in the upstream target while a novel pulse height deconvolution methodology was developed and implemented to characterize neutrons produced in the downstream target. (authors)

43 PARTICLE ACCELERATORS↗

Implementation of a new dose record keeping system - Paper 45

During 2013, AWE implemented a new dosimetry system. As such events occur every twenty years or so, it was considered a major project that would require close collaboration between the end user, supplier and the regulator. This paper describes the journey taken by the project team to ensure a seamless transition from the current system to the newly approved dosimetry database. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of Space Radiation On, and On the Way To, Mars - Paper 123

The Mars Science Laboratory (MSL) spacecraft, with the Curiosity rover inside, was launched to Mars on November 25, 2011, and landed successfully on August 6, 2012. Curiosity's science payload includes ten science instruments, one of which is the Radiation Assessment Detector, RAD. The radiation environment in deep space is harsh, and is a limiting factor in planning future human missions. RAD's measurements of the radiation environments on Mars, and on a spacecraft during transit to Mars, are important precursors to a crewed mission. RAD is a compact instrument with a mass of just 1.56 kg. Despite its small size, RAD is capable of measuring the charged and neutral particles that make up the complex environments created by Galactic Cosmic Rays (GCRs) and Solar Energetic Particles (SEPs) as they traverse shielding materials. The space radiation environment consists of a continuous flux of GCRs, the intensity of which is modulated by solar activity. At or near times of solar maximum, the interplanetary magnetic field is relatively strong, and lower-energy GCRs are screened. At solar minimum, the field weakens with a corresponding increase in GCR fluxes. SEP events are sporadic, and are more likely to occur near solar maximum. Both GCRs and SEPs present potential health risks to astronauts, but the risks are of different types. The dose rate from GCRs is modest and cannot cause acute health effects. However serious late effects may arise; of particular concern are the largely unknown health effects of exposure to high-energy GCR heavy ions. There is no terrestrial analog for this exposure and this leads to large uncertainties in health risk estimates. In contrast, SEP events can be extremely intense and could potentially cause acute health effects, but they are also dominated by protons with energies below 100 MeV, which means that shielding is a practical and effective option. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar particle event predictions for manned Mars missions

Manned space missions to Mars require consideration of the effects of high radiation doses produced by solar particle events (SPE). Without some provision for protection, the radiation doses from such events can exceed standards for maximum exposure and may be life threatening. Several alternative ways of providing protection require a capability for predicting SPE in time to take some protective actions. The SPE may occur at any time during the eleven year solar cycle so that two year missions cannot be scheduled to insure avoiding them although they are less likely to occur at solar minimum. The present forecasts are sufficiently accurate to use for setting alert modes but are not accurate enough to make yes/no decisions that have major mission operational impacts. Forecasts made for one to two year periods can only be done as probabilistic forecasts where there is a chance of SPE occurring. These are current capabilities but are not likely to change significantly by the year 2000 with the exception of some improvement in the one to ten day forecasts. The effects of SPE are concentrated in solar longitudes near where their parent solar flares occur, which will require a manned Mars mission to carry its own small solar telescope to monitor the development of potentially dangerous solar activity. The preferred telescope complement includes a solar X-ray imager, a hydrogen-alpha scanner, and a solar magnetograph.

Heckman, Gary↗

A critical evaluation of the NCRP COMMENTARY 27 endorsement of the linear no-threshold model of radiation effects

Highlights: • The linear no-threshold (LNT) model of radiation effects has fractured the scientific community. • This paper analyzes the latest review of the LNT model, NCRP Commentary 27. • Expert reviews of the LNT model rely on institutional inertia and numerous logical fallacies. • Recommendations to advance this debate in an objective future review are provided. Regulatory policy to protect the public and the environment from radiation is universally based on the linear, no-threshold model (LNT) of radiation effects. This model has been controversial since its inception over nine decades ago, and remains so to this day, but it has proved remarkably resistant to challenge from the scientific community. The LNT model has been repeatedly endorsed by expert advisory bodies, and regulatory agencies in turn adopt policies that reflect this advice. Unfortunately, these endorsements rest on a foundation of institutional inertia and numerous logical fallacies. These include most significantly setting the LNT as the null hypothesis, and shifting the burden of proof onto LNT skeptics. Other examples include arbitrary exclusion of alternative hypotheses, ignoring criticisms of the LNT, cherry-picking evidence, and making policy judgements without foundation. This paper presents an evaluation of the National Council on Radiation Protection and Measurements’ (NCRP) Commentary 27, which concluded that recent epidemiological studies are compatible with the continued use of the LNT model for radiation protection. While this report will likely provide political cover for regulators’ continued reliance on the LNT, it is a missed opportunity to advance the scientific discussion of the effects of low dose, low dose-rate radiation exposure. Due to its Congressionally chartered mission, no organization is better positioned than the NCRP to move this debate forward, and recommendations for doing so in future reviews are provided.

54 ENVIRONMENTAL SCIENCES↗

The Approach of the Environmental Consequences and Impacts during Transport of Radioactive Materials (RAM)-A Safety Case - 16420

International Atomic Energy Agency (IAEA) works, together with Member States (MS), to provide a strong, sustainable and visible global nuclear safety and security framework, protecting people and the environment from the harmful effects of ionizing radiation. In the announcement of this IAEA Conference it is underlined that 'nuclear safety and security are to a great extent scientific in nature, a regulatory body with responsibilities for nuclear facilities and other licensed activities involving radioactive material needs to have permanent access to supporting expertise'. This can be provided internally to the regulatory body or through an external entity such as a TSO in order to provide a competent and timely response to regulatory needs, and the development and maintenance of an appropriate knowledge base and associated tools and services, including training and tutoring services, are the main areas on which the conference will focus. This paper presents certain results obtained during carrying out the IAEA-Romanian Scientific Research Contract entitled: 'Romanian Contribution to the Development of Methodology for Risk Assessment and State Management of Nuclear Security Regime (Risk and Radiological Consequences)' where the author served as CSI (Chief Scientific Investigator) a part of the IAEA CRP-(Coordinated Research Project) on the: 'Development of Methodology for Risk Assessment and State Management of Nuclear Security Regime'. Also, potential risks and their possible radiological consequences to peoples and environment must not be underestimated. However, the assessment of risk must be realistic and quantified, and the requirements placed on the appropriate. The IAEA regulations for the Safe Transport of Radioactive Material, 2012 Edition, Specific Safety Requirements, SSR-6, are applicable to the national and international carriage of radioactive material by all modes of transport- by road, by rail, by air, by sea or by inland waters. The Radioactive Material to be transported must be categorized on the basis of its activity concentration, total activity, fissile characteristics (if any) and other relevant subsidiary characteristics. Packaging and package requirements are then specified on the basis of the hazard of the contents and range from normal commercial packaging (for low hazard contents) to strict design and performance requirements (for higher hazard contents). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel morphometry system automatically assessing the growth and regeneration of intestinal organoids

Highlights: • A new morphometry system for objectively evaluating organoid growth. • Measurable perimeter of organoid cultured for 24 h taken as an “Organoid Unit”. • Heterogeneities and regeneration of organoids can be evaluated by “Organoid Unit”. • Effects of radiation sensitizing or protective agents were objectively measured. As compared with 2D cell line cultures, 3D intestinal organoids are better at maximally recapitulating the physiological features of stem cells in vivo. However, the complex 3D structure is an obstacle which must be objectively and automatically evaluated to assess colony growth and regeneration. Meanwhile, no internal standard currently exists for evaluating the size of heterogeneities in organoids or defining those regenerating colonies. Herein, we developed a simple morphometry system to image MTT-stained organoids. The growth curve of organoids can be automatically generated based upon analyzing the integrated optical density using software. Referencing the definition standards of in vivo regenerating crypts, the perimeters of crypts cultured 24 h after seeding were selected as an “Organoid Unit” to further evaluate colony survival rate and colony size heterogeneities after exposure to varying doses of irradiation. Moreover, the morphometry-based quantification data collected confirmed other findings associated with radiation sensitizing effects of ataxia telangiectasia mutated (ATM) and ataxia telangiectasia and Rad3-related protein (ATR) inhibitor and the radiation protective effect of IL-22. In summary, the novel organoid morphometry system combined with a new internal reference is a practical means for standardizing assessment of growth, survival and regeneration of intestinal organoid colonies. This method has promise to facilitate drug screens in intestinal and other organoid systems.

60 APPLIED LIFE SCIENCES↗

ISEP: A Joint SRAG/CCMC Collaboration to Improve Mitigation of Space Weather Effects on Crew Health in the Exo-LEO Era

The Space Radiation Analysis Group (SRAG) at Johnson Space Center (JSC) is tasked with monitoring changes to space weather and mitigating any resultant impacts to crew health and safety. As human spaceflight goals extend from Low-Earth Orbit (LEO) missions like the International Space Station (ISS) to the moon, Mars and beyond, SRAG will need to update their current approach for crew monitoring of and protection from radiation exposure due to energetic Solar Particle Events (ESPEs). Challenges faced in planning exo-LEO missions include the lack of protection from the Earth’s geomagnetic field employed by the ISS in addition to limited communication capability between the crew and the ground. In the event of an ESPE, the current ISS trajectory ensures that the vehicle is only traveling through fields of higher radiation exposure for a brief period of time; the Earth’s geomagnetic field prevents the penetration of the high-energy particles of concern throughout the majority of the orbit. Exo-LEO missions, on the other hand, require that the vehicle travel through free space, exposing vehicle and crew to the full impact of the ESPE. NASA has combined multiple approaches to resolve this radiation exposure issue. New vehicles are designed to take advantage of advances in particle transport modeling capabilities and shielding technology, allowing redistribution of mass throughout the vehicle to areas of thinner shielding when the energetic particle flux has increased to levels of concern. Although vehicle shielding is an important aspect of radiation exposure protection, there is a continued requirement to monitor and predict the space weather environment. To this end, SRAG maintains a console position in Mission Control with 24/7 mission support capability. In the event of increased solar activity, SRAG collaborates with the Flight Control Team (FCT) to determine if crew action (i.e., shelter) is required. During any increase in solar activity, the FCT needs three pieces of information to effectively decide the crew response in light of other required mission tasks: if an event (ESPE) will occur, how ‘intense’ an observed event will be, and how long will an observed event will last. An ideal alert system limits false alarms, therefore causing the crew to take action unnecessarily, without ignoring events that pose a hazard to the crew. SRAG’s current operational concept for ISS missions focuses on short-term forecasts, best described as ‘now-casting’. Console operators are in daily communication with the Space Weather Prediction Center (SWPC) for situational awareness purposes. When conditions exist that may lead to increased solar activity, operators receive notifications from SWPC. In the case of a well-connected ESPE, the console operator may only have on the order of minutes to several hours to notify the FCT of the event and provide a recommendation for crew action. As NASA shifts to exo-LEO missions, the increased time in free space as well as the reduced ability to communicate with the crew will force a transition in crew protection strategy that emphasizes improvments to both the accuracy and the lead time in forecasting capabilities.

Barzilla, Janet E.↗

Path Toward a Unifid Geometry for Radiation Transport

The Direct Accelerated Geometry for Radiation Analysis and Design (DAGRAD) element of the RadWorks Project under Advanced Exploration Systems (AES) within the Space Technology Mission Directorate (STMD) of NASA will enable new designs and concepts of operation for radiation risk assessment, mitigation and protection. This element is designed to produce a solution that will allow NASA to calculate the transport of space radiation through complex computer-aided design (CAD) models using the state-of-the-art analytic and Monte Carlo radiation transport codes. Due to the inherent hazard of astronaut and spacecraft exposure to ionizing radiation in low-Earth orbit (LEO) or in deep space, risk analyses must be performed for all crew vehicles and habitats. Incorporating these analyses into the design process can minimize the mass needed solely for radiation protection. Transport of the radiation fields as they pass through shielding and body materials can be simulated using Monte Carlo techniques or described by the Boltzmann equation, which is obtained by balancing changes in particle fluxes as they traverse a small volume of material with the gains and losses caused by atomic and nuclear collisions. Deterministic codes that solve the Boltzmann transport equation, such as HZETRN [high charge and energy transport code developed by NASA Langley Research Center (LaRC)], are generally computationally faster than Monte Carlo codes such as FLUKA, GEANT4, MCNP(X) or PHITS; however, they are currently limited to transport in one dimension, which poorly represents the secondary light ion and neutron radiation fields. NASA currently uses HZETRN space radiation transport software, both because it is computationally efficient and because proven methods have been developed for using this software to analyze complex geometries. Although Monte Carlo codes describe the relevant physics in a fully three-dimensional manner, their computational costs have thus far prevented their widespread use for analysis of complex CAD models, leading to the creation and maintenance of toolkit-specific simplistic geometry models. The work presented here builds on the Direct Accelerated Geometry Monte Carlo (DAGMC) toolkit developed for use with the Monte Carlo N-Particle (MCNP) transport code. The workflow for achieving radiation transport on CAD models using MCNP and FLUKA has been demonstrated and the results of analyses on realistic spacecraft/habitats will be presented. Future work is planned that will further automate this process and enable the use of multiple radiation transport codes on identical geometry models imported from CAD. This effort will enhance the modeling tools used by NASA to accurately evaluate the astronaut space radiation risk and accurately determine the protection provided by as-designed exploration mission vehicles and habitats

Lee, Kerry↗

Luminescence dosimetry for evaluation of the external exposure in Metlino, upper Techa River valley, Southern Urals, Russia: Analysis of new results

Luminescence dosimetry was applied in the former settlement of Metlino, Southern Urals, Russia as part of a full-scale study to validate the Techa River Dosimetry System (TRDS) 2016 for the upper Techa River region. The village, which was evacuated in 1956, was located 7 km downstream of the release point of liquid radioactive waste by the Mayak plutonium facility. Several brick samples were taken from north-eastern and south-eastern walls of the granary, facing the former Techa river shoreline and floodplain. Samples were all taken at the same height and measured at different depths into the brick. For the majority of brick samples, good Optically Stimulated Luminescence properties of the quartz grains were observed. In some cases, however, strong levels of sensitization and/or signal recuperation were encountered which necessitated adjustment in the measurement protocols. Anthropogenic doses in bricks varied from 1.5 to 6.6 Gy and the horizontal profiles along both walls showed significant variation, which is explained on a qualitative basis. Further, a dose depth profile is observed for selected samples, which is different from the dose depth profile measured and simulated for samples from the north-western wall of the granary in previous studies. This is qualitatively explained by the differences in source configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Emergency department management of patients internally contaminated with radioactive material

After a radiation emergency that involves the dispersal of radioactive material, patients can become externally and internally contaminated with one or more radionuclides. Internal contamination can lead to the delivery of harmful ionizing radiation doses to various organs and tissues or the whole body. The clinical consequences can range from acute radiation syndrome (ARS) to the long term development of cancer. Estimating the amount of radioactive material absorbed into the body can guide the management of patients. Treatment includes, in addition to supportive care and long term monitoring, certain medical countermeasures like Prussian blue, Calcium DTPA and Zinc DTPA.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal field-splitting algorithm in intensity-modulated radiotherapy: Evaluations using head-and-neck and female pelvic IMRT cases

To develop an optimal field-splitting algorithm of minimal complexity and verify the algorithm using head-and-neck (H and N) and female pelvic intensity-modulated radiotherapy (IMRT) cases. An optimal field-splitting algorithm was developed in which a large intensity map (IM) was split into multiple sub-IMs (≥2). The algorithm reduced the total complexity by minimizing the monitor units (MU) delivered and segment number of each sub-IM. The algorithm was verified through comparison studies with the algorithm as used in a commercial treatment planning system. Seven IMRT, H and N, and female pelvic cancer cases (54 IMs) were analyzed by MU, segment numbers, and dose distributions. The optimal field-splitting algorithm was found to reduce both total MU and the total number of segments. We found on average a 7.9 ± 11.8% and 9.6 ± 18.2% reduction in MU and segment numbers for H and N IMRT cases with an 11.9 ± 17.4% and 11.1 ± 13.7% reduction for female pelvic cases. The overall percent (absolute) reduction in the numbers of MU and segments were found to be on average −9.7 ± 14.6% (−15 ± 25 MU) and −10.3 ± 16.3% (−3 ± 5), respectively. In addition, all dose distributions from the optimal field-splitting method showed improved dose distributions. The optimal field-splitting algorithm shows considerable improvements in both total MU and total segment number. The algorithm is expected to be beneficial for the radiotherapy treatment of large-field IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Differences in dose-volumetric data between the analytical anisotropic algorithm and the x-ray voxel Monte Carlo algorithm in stereotactic body radiation therapy for lung cancer

The objective of this study was to evaluate the differences in dose-volumetric data obtained using the analytical anisotropic algorithm (AAA) vs the x-ray voxel Monte Carlo (XVMC) algorithm for stereotactic body radiation therapy (SBRT) for lung cancer. Dose-volumetric data from 20 patients treated with SBRT for solitary lung cancer generated using the iPlan XVMC for the Novalis system consisting of a 6-MV linear accelerator and micro-multileaf collimators were recalculated with the AAA in Eclipse using the same monitor units and identical beam setup. The mean isocenter dose was 100.2% and 98.7% of the prescribed dose according to XVMC and AAA, respectively. Mean values of the maximal dose (D{sub max}), the minimal dose (D{sub min}), and dose received by 95% volume (D{sub 95}) for the planning target volume (PTV) with XVMC were 104.3%, 75.1%, and 86.2%, respectively. When recalculated with the AAA, those values were 100.8%, 77.1%, and 85.4%, respectively. Mean dose parameter values considered for the normal lung, namely the mean lung dose, V{sub 5}, and V{sub 20}, were 3.7 Gy, 19.4%, and 5.0% for XVMC and 3.6 Gy, 18.3%, and 4.7% for the AAA, respectively. All of these dose-volumetric differences between the 2 algorithms were within 5% of the prescribed dose. The effect of PTV size and tumor location, respectively, on the differences in dose parameters for the PTV between the AAA and XVMC was evaluated. A significant effect of the PTV on the difference in D{sub 95} between the AAA and XVMC was observed (p = 0.03). Differences in the marginal doses, namely D{sub min} and D{sub 95}, were statistically significant between peripherally and centrally located tumors (p = 0.04 and p = 0.02, respectively). Tumor location and volume might have an effect on the differences in dose-volumetric parameters. The differences between AAA and XVMC were considered to be within an acceptable range (<5 percentage points)

61 RADIATION PROTECTION AND DOSIMETRY↗

Reinforcing of QA/QC programs in radiotherapy departments in Croatia: Results of treatment planning system verification

Implementation of advanced techniques in clinical practice can greatly improve the outcome of radiation therapy, but it also makes the process much more complex with a lot of room for errors. An important part of the quality assurance program is verification of treatment planning system (TPS). Dosimetric verifications in anthropomorphic phantom were performed in 4 centers where new systems were installed. A total of 14 tests for 2 photon energies and multigrid superposition algorithms were conducted using the CMS XiO TPS. Evaluation criteria as specified in the International Atomic Energy Agency Technical Reports Series (IAEA TRS) 430 were employed. Results of measurements are grouped according to the placement of the measuring point and the beam energy. The majority of differences between calculated and measured doses in the water-equivalent part of the phantom were in tolerance. Significantly more out-of-tolerance values were observed in “nonwater-equivalent” parts of the phantom, especially for higher-energy photon beams. This survey was done as a part of continuous effort to build up awareness of quality assurance/quality control (QA/QC) importance in the Croatian radiotherapy community. Understanding the limitations of different parts of the various systems used in radiation therapy can systematically improve quality as well.

61 RADIATION PROTECTION AND DOSIMETRY↗

A planning study of simultaneous integrated boost with forward IMRT for multiple brain metastases

The objective of this study was to evaluate the dose conformity and feasibility of whole-brain radiotherapy with a simultaneous integrated boost by forward intensity-modulated radiation therapy in patients with 1 to 3 brain metastases. Forward intensity-modulated radiation therapy plans were generated for 10 patients with 1 to 3 brain metastases on Pinnacle 6.2 Treatment Planning System. The prescribed dose was 30 Gy to the whole brain (planning target volume [PTV]{sub wbrt}) and 40 Gy to individual brain metastases (PTV{sub boost}) simultaneously, and both doses were given in 10 fractions. The maximum diameters of individual brain metastases ranged from 1.6 to 6 cm, and the summated PTVs per patient ranged from 1.62 to 69.81 cm{sup 3}. Conformity and feasibility were evaluated regarding conformation number and treatment delivery time. One hundred percent volume of the PTV{sub boost} received at least 95% of the prescribed dose in all cases. The maximum doses were less than 110% of the prescribed dose to the PTV{sub boost}, and all of the hot spots were within the PTV{sub boost}. The volume of the PTV{sub wbrt} that received at least 95% of the prescribed dose ranged from 99.2% to 100%. The mean values of conformation number were 0.682. The mean treatment delivery time was 2.79 minutes. Ten beams were used on an average in these plans. Whole-brain radiotherapy with a simultaneous integrated boost by forward intensity-modulated radiation therapy in 1 to 3 brain metastases is feasible, and treatment delivery time is short.

61 RADIATION PROTECTION AND DOSIMETRY↗