Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subwavelength films for standoff radiation dosimetry

We present optical subwavelength nanostructure architecture suitable for standoff radiation dosimetry with remote optical readout in the visible or infrared spectral regions. To achieve this, films of subwavelength structures are fabricated over several square inches via the creation of a 2D non-close packed (NCP) array template of radiation-sensitive polymeric nanoparticles, followed by magnetron sputtering of a metallic coating to form a 2D array of separated hemispherical nanoscale metallic shells. The nanoshells are highly reflective at resonance in the visible or infrared depending on design. These structures and their behavior are based on the open ring resonator (ORR) architecture and have their analog in resonant inductive-capacitive (LC) circuits, which display a resonance wavelength that is inversely proportional to the square root of the product of the inductance and capacitance. Therefore, any modification of the nanostructure material properties due to radiation alters the inductive or capacitive behavior of the subwavelength features, which in turn changes their optical properties resulting in a shift in the optical resonance. This shift in resonance may be remotely interrogated actively using either laser illumination or passively by hyperspectral or multispectral sensing with broadband illumination. These structures may be designed to be either anisotropic or isotropic, which can also offer polarization-sensitive interrogation. We present experimental measurements of a radiation induced shift in the optical resonance of a subwavelength film after exposure to an absorbed dose of gamma radiation from 2 Mrad up to 62 Mrad demonstrating the effect. Interestingly the resonance shift is non-monotonic for this material system and possible radiation damage mechanisms to the nanoparticles are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intelligent Experiments Through Real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and Future EIC Detectors (Final Report)

The overall vision of this project was to integrate real-time artificial intelligence (AI) directly into the data acquisition and detector-control systems of nuclear physics experiments, including both fast online event selection and an autonomous detector-control feedback loop. The work carried out under the award focused on the fast online event-selection half of that vision: the efficient recording of low-momentum heavy-flavor (HF) hadron decays in proton-proton collisions at the sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)—an observable that requires fast tracking and topological trigger selection not previously demonstrated at RHIC, and that is essential for QCD studies at future facilities such as the Electron-Ion Collider (EIC). The autonomous detector-control (GPU-based feedback) component named in the project title remained a design concept and was not implemented under this award. The Massachusetts Institute of Technology (MIT) group led the offline simulation and data processing needed to train the machine-learning (ML) models, the translation of trained models to Field-Programmable Gate Array (FPGA) firmware using the hls4ml framework, and the physics validation of heavy-flavor reconstruction. Over the award period, the team developed and hardware-tested the principal components of an AI-based heavy-flavor trigger on simulated and recorded sPHENIX tracker data: a software Bipartite Graph Attention Network (BiGAT) trigger model reaching > 95% signal efficiency at 99% background rejection; an FPGA-native hit clusterizer matching the offline clustering; smaller networks synthesized to FPGA within the required sub-10 µs latency; and an assembled decoder–clusterizer–inference firmware chain exercised on the FELIX readout board. A complete, fully integrated hardware demonstrator was not finished within the award period. This report documents the project goals, the MIT group’s contributions, the technical accomplishments, and the outlook toward applications at the future EIC ePIC detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Development and Operation of a Material Identification and Discrimination Imaging Spectroradiometer

Many imaging applications require quantitative determination of a scene's spectral radiance. This paper describes a new system capable of real-time spectroradiometric imagery. Operating at a full-spectrum update rate of 30Hz, this imager is capable of collecting a 30 point spectrum from each of three imaging heads: the first operates from 400 nm to 950 nm, with a 2% bandwidth; the second operates from 1.5 micro-m to 5.5 micro-m with a 1.5% bandwidth; the third operates from 5 micro-m to 12 micro-m, also at a 1.5% bandwidth. Standard image format is 256 x 256, with 512 x 512 possible in the VIS/NIR head. Spectra of up to 256 points are available at proportionately lower frame rates. In order to make such a tremendous amount of data more manageable, internal processing electronics perform four important operations on the spectral imagery data in real-time. First, all data in the spatial/spectral cube of data is spectro-radiometrically calibrated as it is collected. Second, to allow the imager to simulate sensors with arbitrary spectral response, any set of three spectral response functions may be loaded into the imager including delta functions to allow single wavelength viewing; the instrument then evaluates the integral of the product of the scene spectral radiances and the response function. Third, more powerful exploitation of the gathered spectral radiances can be effected by application of various spectral-matched filtering algorithms to identify pixels whose relative spectral radiance distribution matches a sought-after spectral radiance distribution, allowing materials-based identification and discrimination. Fourth, the instrument allows determination of spectral reflectance, surface temperature, and spectral emissivity, also in real-time. The spectral imaging technique used in the instrument allows tailoring of the frame rate and/or the spectral bandwidth to suit the scene radiance levels, i.e., frame rate can be reduced, or bandwidth increased to improve SNR when viewing low radiance scenes. The unique challenges of design and calibration are described. Pixel readout rates of 160 MHz, for full frame readout rates of 1000 Hz (512 x 512 image) present the first challenge; processing rates of nearly 600 million integer operations per second for sensor emulation, or over 2 billion per second for matched filtering, present the second. Spatial and spectral calibration of 66,536 pixels (262,144 for the 512 x 512 version) and up to 1,000 spectral positions mandate novel decoupling methods to keep the required calibration memory to a reasonable size. Large radiometric dynamic range also requires care to maintain precision operation with minimum memory size.

Dombrowski, Mark↗

Overhaul and installation of the ICARUS-T600 liquid argon TPC electronics for the FNAL Short Baseline Neutrino program

The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016–2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme are described. The design of a new signal feed-through flange is also a fundamental piece of this overhaul whose major feature is the integration of all electronics components onto the signal flange. Initial functionality tests of the full TPC electronics chain installed in the T600 detector at FNAL are also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance study of a 3×1×1 m 3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m 3 ) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory

Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and commissioning of CMS CE prototype silicon modules

As part of its HL-LHC upgrade program, the CMS collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CEE) and hadronic (CE-H) compartments. The calorimeter will be built with ~30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1 cm 2 , and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.

Calorimeters↗

The ePIC dual-radiator RICH detector

The dual radiator Ring Imaging Cherenkov (dRICH) detector is required to provide continuous hadron identification from ≈3 GeV/c up to ≈50 GeV/c, and to supplement electron and positron identification from a few hundred MeV/c up to about 15 GeV/c, in the forward (ion-side) end-cap of the ePIC experiment. Such an extended momentum range imposes the use of two radiators, gas and aerogel. The common imaging system, that ensures compactness and cost-effectiveness, is based on SiPM sensors to work in a high non-uniform magnetic field. During the R&D phase, the dual radiator principle and the single component performance have been validated. A status overview of the project is presented. The design and technological choices are discussed together with the results obtained from laboratory characterization of the component demonstrators and beam tests of the evolving prototypes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20–300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗