Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

High-Magnification Faraday Rotation Imaging and Analysis of X-pinch Implosion Dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 μm), a short axial extent (<1 mm), and a short duration (.1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x-rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. To study the current distribution in the coronal plasma throughout the implosion process, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the 1-MA, 100-ns MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10&times;), this diagnostic achieves a spatial resolution of approximately 35 μm, which is useful for resolving the ~100-μm-scale coronal plasma region immediately surrounding the dense core. Combined with the corresponding interferogram, which provides the radial density distribution in the low-density coronal plasma, the measured rotation can be used to diagnose the delivery of the driver current, and thus the magnetic drive pressure, to the micro-pinch plasma as it approaches minimal radius. Using this technique on MAIZE, we have measured

Dowhan, G. V.↗

Far-infrared line images of dwarf galaxies

Irregular dwarf galaxies are about ten times more widespread in the universe than regular spiral galaxies. They are characterized by a relatively low metallicity, i.e., lower abundance of the heavier elements (metals) with respect to hydrogen than in the solar neighborhood. These heavier elements in the form of molecules, atoms, or ions, which have radiative transitions in the infrared play a decisive role in the energy balance of the ISM and thereby for the formation of stars. Dwarf galaxies are thus model cases for the physical conditions in the early phase of the universe. Large Magellanic Cloud: 30 Doradus. The two nearest dwarf galaxies are the Magellanic clouds at a distance approximately 50 kpc. The LMC contains 30 Dor, a region with young, extremely massive stars which strongly interact with the surrounding ISM on account of their stellar winds and intense UV radiation. 30 Dor is the brightest object in the LMC at almost all wavelengths.

Poglitsch, A.↗

Radiation Belt Environment Model: Application to Space Weather and Beyond

Understanding the dynamics and variability of the radiation belts are of great scientific and space weather significance. A physics-based Radiation Belt Environment (RBE) model has been developed to simulate and predict the radiation particle intensities. The RBE model considers the influences from the solar wind, ring current and plasmasphere. It takes into account the particle drift in realistic, time-varying magnetic and electric field, and includes diffusive effects of wave-particle interactions with various wave modes in the magnetosphere. The RBE model has been used to perform event studies and real-time prediction of energetic electron fluxes. In this talk, we will describe the RBE model equation, inputs and capabilities. Recent advancement in space weather application and artificial radiation belt study will be discussed as well.

Fok, Mei-Ching H.↗

Computational study of nanosecond pulsed laser ablation and the application to momentum coupling

During the evaporation and ablation of a matter induced by intensive laser radiation, the vapor plasma is ejected from the surface of the target which induces the recoil pressure and impulse in the target. Impulse coupling of laser beams with matter has been extensively studied as the basis of laser propulsion and laser clearing space debris. A one-dimensional (1D) bulk absorption model to simulate the solid target ablated directly by the laser beam is presented; numerical calculation of impulse acting on the target in vacuum with different laser parameters is performed with fluid dynamics theory and 1D Lagrange difference scheme. The calculated results of the impulse coupling coefficients are in good agreement with the experimental results and Phipps' empirical value. The simulated results show that the mechanical coupling coefficients decrease with the increment of laser intensity when the laser pulses generate plasma. The present model can be applied when the laser intensity is 10{sup 8} - 10{sup 10} W/cm{sup 2}, which will provide a guide to the study of momentum coupling of laser beams with matter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of {>=}5% in {approx}1 mm{sup 2} areas and {>=}2% in {approx}20 mm{sup 2} areas. Conclusions: The ability to detect small dose differences ({<=}2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified.

60 APPLIED LIFE SCIENCES↗

Generation of singlet oxygen in fullerene-containing media: 2. Fullerene-containing solutions

The generation of singlet oxygen in fullerene solutions is studied by luminescence methods upon excitation by pulsed, repetitively pulsed, and continuous radiation sources. The concentration of singlet oxygen in solutions is measured in stationary and pulsed irradiation regimes. The rate constants of quenching of O{sub 2}({sup 1}{delta}{sub g}) by fullerenes C{sub 70} and C{sub 60} in the CCl{sub 4} solution are measured to be (7.2{+-}0.1)x10{sup 7} L mol{sup -1} s{sup -1} and less than 6x10{sup 4} L mol{sup -1} s{sup -1}, respectively. The temperature and photolytic variations in the generation properties of the fullerene solution exposed to intense continuous radiation are studied by the methods of optical and EPR spectroscopy. Pulsed irradiation resulted in the production of singlet oxygen in suspensions of fullerene-like structures, in particular, astralenes. A liquid pulsed singlet-oxygen generator based on the fullerene solution in CCl{sub 4} is developed and studied, in which the yield of O{sub 2} ({sup 1}{delta}{sub g}) to the gas phase at concentrations up to 5x10{sup 16} cm{sup -3} is obtained. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accuracy of Analog Fiber-Optic Links in Pulsed Radiation Environments

Interferometric fiber-optic links used in pulsed-power experiments are evaluated for accuracy in the presence of radiation fields which alter fiber transmission. Amplitude-modulated format (e.g., Mach-Zehnder) and phase-modulated formats are compared. Historically, studies of radiation effects on optical fibers have focused on degradation and recovery of the fibers transmission properties; such work is either in the context of survivability of fibers in catastrophic conditions or suitability of fibers installed for command and control systems within an experimental facility [1], [2]. In this work, we consider links used to transmit realtime diagnostic data, and we analyze the error introduced by radiation effects during the drive pulse. The result is increased uncertainties in key parameters required to unfold the sinusoidal transfer function. Two types of modulation are considered: amplitude modulation typical of a Mach-Zehnder (M-Z) modulator [3], and phase modulation, which offers more flexible demodulation options but relies on the spatiotemporal coherence of the light in the fiber. The M-Z link is shown schematically in Fig. 1, and the phase-modulated link is shown in Fig. 2. We present data from two experimental environments: one with intense, controlled radiation fields to simulate conditions expected at the next generation of pulsed-power facilities, and the second with radiation effects below the noise level of the recording system. In the first case, we intentionally expose three types of single-mode fiber (SMF) to ionizing radiation and study the response by simultaneously monitoring phase and amplitude of the transmitted light. The phase and amplitude effects are evidently dominated by different physical phenomena, as their recovery dynamics are markedly different; both effects, though, show similar short-term behavior during exposure, integrating the dose at the dose levels studied, from 1 to 300 kRad, over the exposure times of 50 ps and 30 ns. In the second case, we present data using a state-of-the-art fiber-optic link for single-shot transmission and recording, fielded at the OMEGA laser facility on high-yield fusion experiments. Gamma reaction history data are measured with a gas Cherenkov detector (GCD) [4], [5] and transmitted by M-Z link to a 12 GHz digitizer. Since radiation effects on the fibers are not above the noise floor, the error analysis for the unfolded data is dominated by the performance of the fast digitizer, the photoreceiver, and the laser.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benefits of adaptive radiation therapy in lung cancer as a function of replanning frequency

Purpose: To quantify the potential benefit associated with daily replanning in lung cancer in terms of normal tissue dose sparing and to characterize the tradeoff between adaptive benefit and replanning frequency. Methods: A set of synthetic images and contours, derived from weekly active breathing control images of 12 patients who underwent radiation therapy treatment for nonsmall cell lung cancer, is generated for each fraction of treatment using principal component analysis in a way that preserves temporal anatomical trends (e.g., tumor regression). Daily synthetic images and contours are used to simulate four different treatment scenarios: (1) a “no-adapt” scenario that simulates delivery of an initial plan throughout treatment, (2) a “midadapt” scenario that implements a single replan for fraction 18, (3) a “weekly adapt” scenario that simulates weekly adaptations, and (4) a “full-adapt” scenario that simulates daily replanning. An initial intensity modulated radiation therapy plan is created for each patient and replanning is carried out in an automated fashion by reoptimizing beam apertures and weights. Dose is calculated on each image and accumulated to the first in the series using deformable mappings utilized in synthetic image creation for comparison between simulated treatments. Results: Target coverage was maintained and cord tolerance was not exceeded for any of the adaptive simulations. Average reductions in mean lung dose (MLD) and volume of lung receiving 20 Gy or more (V20{sub lung}) were 65 ± 49 cGy (p = 0.000 01) and 1.1% ± 1.2% (p = 0.0006), respectively, for all patients. The largest reduction in MLD for a single patient was 162 cGy, which allowed an isotoxic escalation of the target dose of 1668 cGy. Average reductions in cord max dose, mean esophageal dose (MED), dose received by 66% of the heart (D66{sub heart}), and dose received by 33% of the heart (D33{sub heart}), were 158 ± 280, 117 ± 121, 37 ± 77, and 99 ± 120 cGy, respectively. Average incremental reductions in MLD for the midadapt, weekly adapt, and full-adapt treatments were 38, 18, and 8 cGy, respectively. Incremental reductions in MED for the same treatments were 57, 37, and 23 cGy. Reductions in MLD and MED for the full-adapt treatment were correlated with the absolute decrease in the planning target volume (r = 0.34 and r = 0.26). Conclusions: Adaptive radiation therapy for lung cancer yields clinically relevant reductions in normal tissue doses for frequencies of adaptation ranging from a single replan up to daily replanning. Increased frequencies of adaptation result in additional benefit while magnitude of benefit decreases.

60 APPLIED LIFE SCIENCES↗

Optically Stimulated Luminescence Response of Commercial SiO2 Optical Fiber

The use of Optically Stimulated Luminescence (OSL) for radiation dosimetry has become increasingly popular in recent years. The OSL method is based on luminescence emitted from semiconductor materials stimulated with specific wavelengths of light, after being exposed to ionizing radiation. The OSL intensity is a function of the radiation dose absorbed by the material. This work complements previous studies by the authors of the thermoluminescence (TL) response by SiO{sub 2} commercial optical fiber exposed to ionizing radiation and provides preliminary results describing some of the material's OSL properties. Linear OSL response to beta-radiation dose, along with a consistent shape of the photon emission curve with time, were observed using a green/blue OSL excitation laser. The reproducibility of OSL response after repeated irradiations and the change in intensity with time were also examined. The search for and characterization of materials that exhibit this OSL response, in parallel with the continued development of OSL methodology and instrumentation, is an important scientific and commercial issue.

36 MATERIALS SCIENCE↗

Optimization of Isocenter Location for Intensity Modulated Stereotactic Treatment of Small Intracranial Targets

Purpose: To quantify the impact of isocenter location on treatment plan quality for intensity-modulated stereotactic treatment of small intracranial lesions. Methods and Materials: For 18 patients previously treated by stereotactic-intensity modulated radiosurgery (IMRS) or intensity-modulated radiation therapy (IMRT), a retrospective virtual planning study was conducted wherein the impact of isocenter location on plan quality was measured. Treatment indications studied included six arteriovenous malformations, six acoustic neuromas, and six intracranial metastases, ranging in volume from 0.71 to 3.21 cm{sup 3} (mean = 2.26 cm{sup 3}), 1.08 to 2.84 cm{sup 3} (mean = 1.73 cm{sup 3}), and 0.19 to 2.30 cm{sup 3} (mean = 0.79 cm{sup 3}), respectively. Variation of isocenter location causes the geometric grid of pencil beams into which the target is segmented for intensity-modulated treatment to be altered. The impact of this pencil-beam-grid redefinition on achievable conformity index was quantified for three collimators (Varian Millennium 120; BrainLab MM3; Nomos binary Mimic) and three treatment planning systems (TPS; Varian Eclipse v6.5; BrainLab BrainScan v5.31; Best-Nomos Corvus v6.2), resulting in the evaluation of 3,446 treatment plans. Results: For all patients, collimator, and TPS combinations studied, a significant variation in plan quality was observed as a function of isocenter and pencil-beam-grid relocation. Optimization of isocenter location resulted in treatment plan conformity variations as large as 109% (min = 15%, mean = 51%, max = 109%). Conclusion: Optimization of isocenter location for IMRT/IMRS treatment of small intracranial lesions in which pencil-beam dimensions are comparable to target dimensions, can result in significant improvements in treatment plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystalline Colloidal Arrays in Polymer Matrices

Crystalline Colloidal Arrays (CCA, also known as colloidal crystals), composed of aqueous or nonaqueous dispersions of self-assembled nanosized polymer colloidal spheres, are emerging toward the development of advanced optical devices for technological applications. The spontaneous self assembly of polymer spheres in a dielectric medium results from the electrostatic repulsive interaction between particles of uniform size and charge distribution. In a way similar to atomic crystals that diffract X-rays, CCA dispersions in thin quartz cells selectively and efficiently Bragg diffract the incident visible light. The reason for this diffraction is because the lattice (body or face centered cubic) spacing is on the order of the wavelength of visible light. Unlike the atomic crystals that diffract a fixed wavelength, colloidal crystals in principle, depending on the particle size, particle number and charge density, can diffract W, Vis or IR light. Therefore, the CCA dispersions can be used as laser filters. Besides, the diffraction intensity depends on the refractive index mismatch between polymer spheres and dielectric medium; therefore, it is possible to modulate incident light intensities by manipulating the index of either the spheres or the medium. Our interest in CCA is in the fabrication of all-optical devices such as optical switches, limiters, and spatial light modulators for optical signal processing. The two major requirements from a materials standpoint are the incorporation of suitable nonlinear optical materials (NLO) into polymer spheres which will allow us to alter the refractive index of the spheres by intense laser radiation, and preparation of solid CCA filters which can resist laser damage. The fabrication of solid composite filters not only has the advantage that the films are easier to handle, but also the arrays in solid films are more robust than in liquid media. In this paper, we report the photopolymerization process used to trap CCA in polymer matrices, the factors which affect the optical diffraction qualities of resulting polymer films, and methods to improve the efficiencies of solid optical filters. Before this, we also present the experimental demonstration, of controlling the optical diffraction intensities from aqueous CCA dispersions by varying the temperature, which establishes the feasibility of fabricating all-optical switching devices with nonlinear periodic array structures.

Sunkara, Hari B.↗

The Effect of Changing Technique, Dose, and PTV Margin on Therapeutic Ratio During Prostate Radiotherapy

Purpose: To quantify the dosimetric and radiobiological changes seen when using intensity-modulated radiation therapy (IMRT) or planning target volume (PTV) margin reduction with consistent planning parameters in a representative sample of localized prostate cancer patients. Methods and Materials: Twenty patients were randomly selected from a cohort that received 79.8 Gy using six-field conformal radiotherapy. Using the clinical contours, PTV margin, planning system, and dose constraints, five-field IMRT plans were generated for 79.8, 83.8, and 88.0 Gy. The 88.0-Gy IMRT plan was then reoptimized with a PTV margin reduced to 3 mm. These plans were then compared using various dosimetric and radiobiological endpoints calculated for various {alpha}/{beta}. Results: Intensity-modulated RT resulted in greater conformity to the PTV (p < 0.001). No improvement in mean normal tissue complication probabilities in the rectal wall (NTCPrw) was seen, and the modified therapeutic ratio (TR{sub mod}) was largely unchanged between six-field conformal and IMRT for the majority of the patients. When IMRT was used to escalate dose, NTCPrw increased by 9% at each 5% prescription increase (p < 0.001). Reducing the posterior PTV margin from 7 mm to 3 mm for an IMRT plan reduced the mean NTCPrw by 12% (p < 0.001) and resulted in a trend toward increased TR{sub mod}(p = 0.005). Changes in TR{sub mod} between conformal and IMRT planning or PTV reduction showed large interpatient variability. Conclusions: Changing from conformal to IMRT, or from PTV{sub 10-7} to PTV{sub 3}, did not produce a uniform interpatient increase in TR{sub mod}when the CTV contained the prostate alone. Radiobiological benefits of these two methods seem to be dependent on the particular anatomy of individual patients, supporting the use of patient-specific margin, planning, and dose prescription strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Stereotactic Spine Radiosurgery on a Conventional Linear Accelerator

Stereotactic radiosurgery for spinal metastasis consists of a high radiation dose delivered to the tumor in 1 to 5 fractions. Due to the high radiation dose in a single or fewer treatments, the precision of tumor localization and dose delivery is of great concern. Many groups have published their experiences of spinal radiosurgery with the use of CyberKnife System (Accuray Inc.). In this study, we report in detail our approach to stereotactic spine radiosurgery (SSRS) using a conventional linear accelerator (Varian Trilogy), utilizing the features of kilovolt on-board imaging (kV-OBI) and cone beam computed tomography (CBCT) for image guidance. We present our experience in various aspects of the SSRS procedure, including patient simulation and immobilization, intensity-modulated radiation treatment (IMRT) planning and beam selection, portal dosimetry for patient planning quality assurance (QA), and the use of image guidance in tumor localization prior to and during treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

U and Pu Gamma-Ray Measurements of Spent Fuel Using a Gamma-Ray Mirror Band-Pass Filter

Abstract. We report on the use of grazing incidence gamma-ray mirrors to serve as a narrow band-pass filter for advanced non-destructive analysis (NDA) of spent nuclear fuel. The purpose of the mirrors is to limit the radiation reaching a HPGe detector to narrow spectral bands around characteristic emission lines from fissile isotopes in the fuel. This overcomes the normal rate issues when performing gamma-ray NDA measurements. In a proof-of-concept experiment, a set of simple flat gamma-ray mirrors were used to directly observe the atomic florescence lines from U and Pu from spent fuel pins with the detector located in a shirt-sleeve environment. The mirrors, consisting of highly polished silicon substrates deposited with WC/SiC multilayer coatings, successfully deflected the lines of interest while the intense primary radiation beam from the fuel was blocked by a lead beam stop. The gamma-ray multilayer coatings that make the mirrors work at the gamma-ray energies used here (~ 100 keV) have been experimentally tested at energies as high as 645 keV, indicating that direct observation of nuclear emission lines from 239Pu should be possible with an appropriately designed optic and shielding configuration.

Ziock, Klaus-Peter↗

A Method for Evaluating Quality Assurance Needs in Radiation Therapy

The increasing complexity of modern radiation therapy planning and delivery techniques challenges traditional prescriptive quality control and quality assurance programs that ensure safety and reliability of treatment planning and delivery systems under all clinical scenarios. Until now quality management (QM) guidelines published by concerned organizations (e.g., American Association of Physicists in Medicine [AAPM], European Society for Therapeutic Radiology and Oncology [ESTRO], International Atomic Energy Agency [IAEA]) have focused on monitoring functional performance of radiotherapy equipment by measurable parameters, with tolerances set at strict but achievable values. In the modern environment, however, the number and sophistication of possible tests and measurements have increased dramatically. There is a need to prioritize QM activities in a way that will strike a balance between being reasonably achievable and optimally beneficial to patients. A systematic understanding of possible errors over the course of a radiation therapy treatment and the potential clinical impact of each is needed to direct limited resources in such a way to produce maximal benefit to the quality of patient care. Task Group 100 of the AAPM has taken a broad view of these issues and is developing a framework for designing QM activities, and hence allocating resources, based on estimates of clinical outcome, risk assessment, and failure modes. The report will provide guidelines on risk assessment approaches with emphasis on failure mode and effect analysis (FMEA) and an achievable QM program based on risk analysis. Examples of FMEA to intensity-modulated radiation therapy and high-dose-rate brachytherapy are presented. Recommendations on how to apply this new approach to individual clinics and further research and development will also be discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Heart-sparing radiotherapy in patients with breast cancer: What are the techniques used in the clinical routine?

The aim of this study was to understand the practice of care in German-speaking countries with regard to heart-sparing radiotherapy techniques. Between August 2015 and September 2015, an e-mail/fax-based survey was sent to radiation oncology departments in Germany, Austria, and the German-speaking Switzerland. The questionnaire was divided into 3 chapters: a general chapter on the department, a chapter specific for heart-sparing techniques in patients with breast cancer, and a third chapter on personal beliefs on the topic of heart sparing in patients with breast cancer. A total of 82 radiation oncology departments answered the questionnaire: 16 university clinics and 66 other departments. In general, heart-sparing techniques are being offered by 90.2% of departments for radiation oncology in the German-speaking countries. However, in the clinical routine, 87.7% of institutions use heart-sparing techniques in less than 50% of patients with breast cancer. Heart-sparing techniques are especially provided for patients with left-sided breast cancer (80%), patients after mastectomy (52.5%), and when the mammaria interna lymph drainage vessels are irradiated (41.3%). In 46.3% of departments, there are written internal guidelines for heart sparing in patients with breast cancer. Breathing-adapted radiotherapy is used as the most frequent heart-sparing technique in 64.7% of the institutions, followed by intensity-modulated radiation therapy, which is most frequently used by 22.1%. The only significant difference between university hospitals and other departments was seen for the offering of partial breast irradiation. The most commonly used heart-sparing technique is breathing-adapted radiotherapy, but there is no coherent approach for heart sparing in patients with breast cancer in the German-speaking countries. Overall, all options for cardiac protection/cardiac avoidance have their advantages and disadvantages, with deep inspiration breath-hold radiotherapyhaving the most clear data, which should be the preferred choice when using heart-sparing techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer

Stereotactic body radiation therapy (SBRT), which delivers a much higher fractional dose than conventional treatment in only a few fractions, is an effective treatment for liver metastases. For patients who are treated under free-breathing conditions, however, respiration-induced tumor motion in the liver is a concern. Limited clinical information is available related to the impact of tumor motion and treatment technique on the dosimetric consequences. This study evaluated the dosimetric deviations between planned and delivered SBRT dose in the presence of tumor motion for three delivery techniques: three-dimensional conformal static beams (3DCRT), dynamic conformal arc (DARC), and intensity-modulated radiation therapy (IMRT). Five cases treated with SBRT for liver metastases were included in the study, with tumor motions ranging from 0.5 to 1.75 cm. For each case, three different treatment plans were developed using 3DCRT, DARC, and IMRT. The gantry/multileaf collimator (MLC) motion in the DARC plans and the MLC motion in the IMRT plans were synchronized to the patient's respiratory motion. Retrospectively sorted four-dimensional computed tomography image sets were used to determine patient-organ motion and to calculate the dose delivered during each respiratory phase. Deformable registration, using thin-plate-spline models, was performed to encode the tumor motion and deformation and to register the dose-per-phase to the reference phase images. The different dose distributions resulting from the different delivery techniques and motion ranges were compared to assess the effect of organ motion on dose delivery. Voxel dose variations occurred mostly in the high gradient regions, typically between the target volume and normal tissues, with a maximum variation up to 20%. The greatest CTV variation of all the plans was seen in the IMRT technique with the largest motion range (D99: -8.9%, D95: -8.3%, and D90: -6.3%). The greatest variation for all 3DCRT plans was less than 2% for D95. Dose variations for DARC fell between the 3DCRT and IMRT techniques. The dose volume histogram variations for normal organs were negligible. Therefore, the IMRT technique may be a preferable treatment choice in cases where the target volume and critical organs are in close proximity, or when normal organ protection is a high priority, provided that motion effect for the target volume can be managed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗