Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum Information Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

TaZr_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys tantalum-zirconium (Ta-Zr). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach \cite{PAW}. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Ta and Zr. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on NERSC-Perlmutter and OLCF-Summit using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Cases 1-10 have been run without generating the file 'vaspout.h5'. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for binary alloys is AXBY, where A and B refer to the constituents, whereas X and Y are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: FILES contained in each subdirectory with name "case-N" where N ranges between 11 and 80, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. 0.POSCAR: input file that defines the atomic structure of a system 4. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 7. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. OUTCAR: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. 13. CHGCAR: contains the charge density data of a system. This data is crucial for analyzing electronic structures, calculating electrostatic potential, and studying the distribution of charge in a crystal or molecular system FILES contained in each subdirectory with name "case-N" where N ranges between 1 and 10 and between 81 and 100, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. {ID}.POSCAR: input file that defines the atomic structure of a system at the beginning of ID execution of geometry optimization with PREC=LOW 4. {ID}.CONTCAR: output file that provides the atomic positions and cell parameters at the end of ID execution of geometry optimization with PREC=LOW in the INCAR file 5. {ID}.OUTCAR: output file that contains detailed information about the progress of a calculation after the ID execution of geometry optimization that has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.{ID}.out: file with diagnostic information about the execution of the ID execution of the geometry optimization with precision variable set to PREC=Low in the INCAR file 7. N{ID}.POSCAR: input file that defines the atomic structure of a system after the geometry optimization run at low precision. This represents the input for the ID execution of the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. N{ID}.CONTCAR: output file that provides the atomic positions and cell parameters after the ID execution of the geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 9. N{ID}.OUTCAR: output file that contains detailed information about the progress of a calculation after the ID execution of the geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.{ID}.out: file with diagnostic information about the ID execution of geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. 13. CHGCAR: contains the charge density data of a system. This data is crucial for analyzing electronic structures, calculating electrostatic potential, and studying the distribution of charge in a crystal or molecular system This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216. REFERENCES (1) Kresse, G. & Hafner, J. Ab initio molecular dynamics for liquid metals. Phys. review B 47, 558 (1993). (2) Kresse, G. & Hafner, J. Ab initio molecular-dynamics simulation of the liquid-metal–amorphous-semiconductor transition in germanium. Phys. Rev. B 49, 14251 (1994) (3) Kresse, G. & Furthmüller, J. Efficiency of ab-initio total energy calculations for metals and semiconductors using a plane-wave basis set. Comput. materials science 6, 15–50 (1996) (4) Kresse, G. & Furthmüller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Phys. review B 54, 11169 (1996) (5) Kresse, G. & Joubert, D. From ultrasoft pseudopotentials to the projector augmented-wave method. Phys. review b 59, 1758 (1999)

36 MATERIALS SCIENCE↗

Symmetry-Based Phenomenological Model for Magnon Transport in a Multiferroic

Magnons-carriers of spin information-can be controlled by electric fields in the multiferroic BiFeO 3 (BFO), a milestone that brings magnons closer to application in future devices. The origin of magnon-spin currents in BFO, however, is not fully understood due to BFO's complicated magnetic texture. In this Letter, we present a phenomenological model to elucidate the existence of magnon spin currents in generalized multiferroics by examining the symmetries inherent to their magnetic and polar structures. This model is grounded in experimental data obtained from BFO and its derivatives, which informs the symmetry operations and resultant magnon behavior. By doing so, we address the issue of symmetry-allowed, switchable magnon spin transport in multiferroics, thereby establishing a critical framework for comprehending magnon transport within complex magnetic textures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and Theoretical Confirmation of Covalent Bonding in α‐Pu

Plutonium's radioactivity provides functionality for nuclear batteries, nuclear reactors, etc., but its complex electronic properties harbor strongly correlated behavior giving rise to a host of interesting phenomena including the presence of a ca. 25% volume collapse between δ-Pu and α-Pu. The complex bonding environments of the ground state allotrope, α-Pu, serve as a unique testing ground for new computational and experimental approaches within the Pu science community. For the first time, a combination of novel ansatzes is used in all-electron density functional theory (DFT) and pair distribution functions (PDF) obtained from high-Q X-ray diffraction to study the bonding behavior in α-Pu. This first experimental and theoretical co-informed description of local bonding behavior for α-Pu reveals covalent bonds, which is a topic that remains of interest in this allotrope. The covalent bonding present at the atomistic level accounts for several of α-Pu's macropscopic properties (e.g., Poisson's ratio) that in turn explains its physical functionalities relative to other allotropic phases like δ-Pu.

36 MATERIALS SCIENCE↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗

Near-infrared spectral tomography integrated with digital breast tomosynthesis: Effects of tissue scattering on optical data acquisition design

Purpose: Design optimization and phantom validation of an integrated digital breast tomosynthesis (DBT) and near-infrared spectral tomography (NIRST) system targeting improvement in sensitivity and specificity of breast cancer detection is presented. Factors affecting instrumentation design include minimization of cost, complexity, and examination time while maintaining high fidelity NIRST measurements with sufficient information to recover accurate optical property maps. Methods: Reconstructed DBT slices from eight patients with abnormal mammograms provided anatomical information for the NIRST simulations. A limited frequency domain (FD) and extensive continuous wave (CW) NIRST system was modeled. The FD components provided tissue scattering estimations used in the reconstruction of the CW data. Scattering estimates were perturbed to study the effects on hemoglobin recovery. Breast mimicking agar phantoms with inclusions were imaged using the combined DBT/NIRST system for comparison with simulation results. Results: Patient simulations derived from DBT images show successful reconstruction of both normal and malignant lesions in the breast. They also demonstrate the importance of accurately quantifying tissue scattering. Specifically, 20% errors in optical scattering resulted in 22.6% or 35.1% error in quantification of total hemoglobin concentrations, depending on whether scattering was over- or underestimated, respectively. Limited frequency-domain optical signal sampling provided two regions scattering estimates (for fat and fibroglandular tissues) that led to hemoglobin concentrations that reduced the error in the tumor region by 31% relative to when a single estimate of optical scattering was used throughout the breast volume of interest. Acquiring frequency-domain data with six wavelengths instead of three did not significantly improve the hemoglobin concentration estimates. Simulation results were confirmed through experiments in two-region breast mimicking gelatin phantoms. Conclusions: Accurate characterization of scattering is necessary for quantification of hemoglobin. Based on this study, a system design is described to optimally combine breast tomosynthesis with NIRST.

60 APPLIED LIFE SCIENCES↗

SU-D-204-01: A Methodology Based On Machine Learning and Quantum Clustering to Predict Lung SBRT Dosimetric Endpoints From Patient Specific Anatomic Features

Purpose: To develop a data-mining methodology based on quantum clustering and machine learning to predict expected dosimetric endpoints for lung SBRT applications based on patient-specific anatomic features. Methods: Ninety-three patients who received lung SBRT at our clinic from 2011–2013 were retrospectively identified. Planning information was acquired for each patient, from which various features were extracted using in-house semi-automatic software. Anatomic features included tumor-to-OAR distances, tumor location, total-lung-volume, GTV and ITV. Dosimetric endpoints were adopted from RTOG-0195 recommendations, and consisted of various OAR-specific partial-volume doses and maximum point-doses. First, PCA analysis and unsupervised quantum-clustering was used to explore the feature-space to identify potentially strong classifiers. Secondly, a multi-class logistic regression algorithm was developed and trained to predict dose-volume endpoints based on patient-specific anatomic features. Classes were defined by discretizing the dose-volume data, and the feature-space was zero-mean normalized. Fitting parameters were determined by minimizing a regularized cost function, and optimization was performed via gradient descent. As a pilot study, the model was tested on two esophageal dosimetric planning endpoints (maximum point-dose, dose-to-5cc), and its generalizability was evaluated with leave-one-out cross-validation. Results: Quantum-Clustering demonstrated a strong separation of feature-space at 15Gy across the first-and-second Principle Components of the data when the dosimetric endpoints were retrospectively identified. Maximum point dose prediction to the esophagus demonstrated a cross-validation accuracy of 87%, and the maximum dose to 5cc demonstrated a respective value of 79%. The largest optimized weighting factor was placed on GTV-to-esophagus distance (a factor of 10 greater than the second largest weighting factor), indicating an intuitively strong correlation between this feature and both endpoints. Conclusion: This pilot study shows that it is feasible to predict dose-volume endpoints based on patient-specific anatomic features. The developed methodology can potentially help to identify patients at risk for higher OAR doses, thus improving the efficiency of treatment planning. R01-184173.

60 APPLIED LIFE SCIENCES↗

Dysprosium-doped cadmium oxide as a gateway material for mid-infrared plasmonics

The interest in plasmonic technologies surrounds many emergent optoelectronic applications, such as plasmon lasers, transistors, sensors and information storage. Although plasmonic materials for ultraviolet–visible and near-infrared wavelengths have been found, the mid-infrared range remains a challenge to address: few known systems can achieve subwavelength optical confinement with low loss in this range. With a combination of experiments and ab initio modelling, here we demonstrate an extreme peak of electron mobility in Dy-doped CdO that is achieved through accurate ‘defect equilibrium engineering’. In so doing, we create a tunable plasmon host that satisfies the criteria for mid-infrared spectrum plasmonics, and overcomes the losses seen in conventional plasmonic materials. In particular, extrinsic doping pins the CdO Fermi level above the conduction band minimum and it increases the formation energy of native oxygen vacancies, thus reducing their populations by several orders of magnitude. The substitutional lattice strain induced by Dy doping is sufficiently small, allowing mobility values around 500 cm 2 V –1 s –1 for carrier densities above 10 20 cm –3 . As a result, our work shows that CdO:Dy is a model system for intrinsic and extrinsic manipulation of defects affecting electrical, optical and thermal properties, that oxide conductors are ideal candidates for plasmonic devices and that the defect engineering approach for property optimization is generally applicable to other conducting metal oxides.

36 MATERIALS SCIENCE↗

Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE

Purpose: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study was to design anatomically informed textured phantoms and use the phantoms to assess quantum noise properties across two clinically available reconstruction algorithms, filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE). Methods: Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom included intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based on a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and, along with a uniform phantom of similar size, were imaged on a Siemens SOMATOM Definition Flash CT scanner and reconstructed with FBP and SAFIRE. Fifty repeated acquisitions were acquired for each background type and noise was assessed by estimating pixel-value statistics, such as standard deviation (i.e., noise magnitude), autocorrelation, and noise power spectrum. Noise stationarity was also assessed by examining the spatial distribution of noise magnitude. The noise properties were compared across background types and between the two reconstruction algorithms. Results: In FBP and SAFIRE images, noise was globally nonstationary for all phantoms. In FBP images of all phantoms, and in SAFIRE images of the uniform phantom, noise appeared to be locally stationary (within a reasonably small region of interest). Noise was locally nonstationary in SAFIRE images of the textured phantoms with edge pixels showing higher noise magnitude compared to pixels in more homogenous regions. For pixels in uniform regions, noise magnitude was reduced by an average of 60% in SAFIRE images compared to FBP. However, for edge pixels, noise magnitude ranged from 20% higher to 40% lower in SAFIRE images compared to FBP. SAFIRE images of the lung phantom exhibited distinct regions with varying noise texture (i.e., noise autocorrelation/power spectra). Conclusions: Quantum noise properties observed in uniform phantoms may not be representative of those in actual patients for nonlinear reconstruction algorithms. Anatomical texture should be considered when evaluating the performance of CT systems that use such nonlinear algorithms.

60 APPLIED LIFE SCIENCES↗

A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data

Purpose: Digital breast tomosynthesis (DBT) is a promising breast cancer screening tool that has already begun making inroads into clinical practice. However, there is ongoing debate over how to quantitatively evaluate and optimize these systems, because different definitions of image quality can lead to different optimal design strategies. Powerful and accurate tools are desired to extend our understanding of DBT system optimization and validate published design principles. Methods: The authors developed a virtual trial framework for task-specific DBT assessment that uses digital phantoms, open-source x-ray transport codes, and a projection-space, spatial-domain observer model for quantitative system evaluation. The authors considered evaluation of reconstruction algorithms as a separate problem and focused on the information content in the raw, unfiltered projection images. Specifically, the authors investigated the effects of scan angle and number of angular projections on detectability of a small (3 mm diameter) signal embedded in randomly-varying anatomical backgrounds. Detectability was measured by the area under the receiver-operating characteristic curve (AUC). Experiments were repeated for three test cases where the detectability-limiting factor was anatomical variability, quantum noise, or electronic noise. The authors also juxtaposed the virtual trial framework with other published studies to illustrate its advantages and disadvantages. Results: The large number of variables in a virtual DBT study make it difficult to directly compare different authors' results, so each result must be interpreted within the context of the specific virtual trial framework. The following results apply to 25% density phantoms with 5.15 cm compressed thickness and 500 {mu}m{sup 3} voxels (larger 500 {mu}m{sup 2} detector pixels were used to avoid voxel-edge artifacts): 1. For raw, unfiltered projection images in the anatomical-variability-limited regime, AUC appeared to remain constant or increase slightly with scan angle. 2. In the same regime, when the authors fixed the scan angle, AUC increased asymptotically with the number of projections. The threshold number of projections for asymptotic AUC performance depended on the scan angle. In the quantum- and electronic-noise dominant regimes, AUC behaviors as a function of scan angle and number of projections sometimes differed from the anatomy-limited regime. For example, with a fixed scan angle, AUC generally decreased with the number of projections in the electronic-noise dominant regime. These results are intended to demonstrate the capabilities of the virtual trial framework, not to be used as optimization rules for DBT. Conclusions: The authors have demonstrated a novel simulation framework and tools for evaluating DBT systems in an objective, task-specific manner. This framework facilitates further investigation of image quality tradeoffs in DBT.

60 APPLIED LIFE SCIENCES↗

Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

Purpose: To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Methods: Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Results: Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. Conclusions: The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.

60 APPLIED LIFE SCIENCES↗

Local-Ising-type magnetic order and metamagnetism in the rare-earth pyrogermanate Er 2 Ge 2 O 7

The recent discoveries of proximate quantum spin-liquid compounds and their potential application in quantum computing informs the search for new candidate materials for quantum spin-ice and spin-liquid physics. While the majority of such work has centered on members of the pyrochlore family due to their inherently frustrated linked tetrahedral structure, the rare-earth pyrogermanates also show promise for possible frustrated magnetic behavior. With the familiar stoichiometry R 2 Ge 2 O 7 , these compounds generally have tetragonal symmetry with a rare-earth sublattice built of a spiral of alternating edge and corner-sharing rare-earth site triangles. Studies on Dy 2 Ge 2 O 7 and Ho 2 Ge 2 O 7 have shown tunable low temperature antiferromagnetic order, a high frustration index, and spin-ice-like dynamics. Here we use neutron diffraction to study magnetic order in Er 2 Ge 2 O 7 (space group P4 1 2 1 2) and find the lowest yet Neél temperature in the pyrogermanates of 1.15 K. Using neutron powder diffraction, we find the magnetic structure to order with k=(0,0,0) ordering vector, magnetic space group symmetry P4' 1 2 1 2', and a refined Er moment of m=8.1μ B near the expected value for the Er 3+ free ion. Provocatively, the magnetic structure exhibits similar “local Ising” behavior to that seen in the pyrocholres where the Er moment points up or down along the short Er-Er bond. Upon applying a magnetic field, we find a first-order metamagnetic transition at ~0.35T to a lower symmetry P2' 1 2' 1 2 structure. This magnetic transition involves an inversion of Er moments aligned antiparallel to the applied field describing a class I spin-flip-type transition, indicating a strong local anisotropy at the Er site—reminiscent of that seen in the spin-ice pyrochlores.

36 MATERIALS SCIENCE↗

Stability and support issues in the construction of large span caverns for physics

New physics experiments, proposed to study neutrinos and protons, call for the use of large underground particle detectors. In the United States, such detectors would be housed in the US Deep Underground Science and Engineering Laboratory (DUSEL), sited within the footprint of the defunct Homestake Mine, South Dakota. Although the experimental proposals differ in detail, all rely heavily upon the ability of the mined and reinforced rock mass to serve as a stable host for the detector facilities. Experimental proposals, based on the use of Water Cherenkov detector technology, specify rock caverns with excavated volumes in excess of half a million cubic meters, spans of at least 50 m, sited at depths of approximately one to 1.5 kilometers. Although perhaps sited at shallower depth, proposals based on the use of Liquid Argon (LAr) detector technology are no less challenging. LAr proposals not only call for the excavation of large span caverns, but have an additional need for the safe management of large quantities (kilo-tonnes) of cryogenic liquid, including critical provisions for the fail-safe egress of underground personnel and the reliable exhaust of Argon gas in the event of a catastrophic release. These multi-year, high value physics experiments will provide the key experimental data needed to support the research of a new generation of physicists as they probe the behavior of basic particles and the fundamental laws of nature. The rock engineer must deliver caverns that will reliably meet operational requirements and remain stable for periods conservatively estimated to be in excess of twenty years. This paper provides an overview of the DUSEL site conditions and discusses key end-user requirements and design criteria likely to dominate in determining the viability of experimental options. The paper stresses the paramount importance of collecting adequate site-specific data to inform early siting, dimensioning and layout decisions. Given the large-scale of the excavation and likely timeline to construction, the paper also strongly suggests that there are exciting opportunities for the rock mechanics and engineering community to identify and efficiently integrate research components into the design and construction process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical note: Optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method

Purpose: This article describes the spectral optimization of dual-energy computed tomography using balanced filters (bf-DECT) to reduce the tube loadings and dose by dedicating to the acquisition of electron density information, which is essential for treatment planning in radiotherapy. Methods: For the spectral optimization of bf-DECT, the author calculated the beam-hardening error and air kerma required to achieve a desired noise level in an electron density image of a 50-cm-diameter cylindrical water phantom. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. Results: The optimal combination of tube voltages was 80 kV/140 kV in conjunction with Tb/Hf and Bi/Mo filter pairs; this combination agrees with that obtained in a previous study [M. Saito, ''Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method,'' Med. Phys. 36, 3631-3642 (2009)], although the thicknesses of the filters that yielded a minimum tube output were slightly different from those obtained in the previous study. The resultant tube loading of a low-energy scan of the present bf-DECT significantly decreased from 57.5 to 4.5 times that of a high-energy scan for conventional DECT. Furthermore, the air kerma of bf-DECT could be reduced to less than that of conventional DECT, while obtaining the same figure of merit for the measurement of electron density and effective atomic number. Conclusions: The tube-loading and dose efficiencies of bf-DECT were considerably improved by sacrificing the quality of the noise level in the images of effective atomic number.

60 APPLIED LIFE SCIENCES↗

TH-C-17A-01: Imaging Sensor Comparison for Real-Time Cherenkov Signal Detection From Tissue for Treatment Verification

Purpose: To identify the optimum imaging sensor for a clinical system that would provide real-time imaging of the surface beam profile on patients as novel visual information to radiation therapy technologists, and more rapidly collect clinical data for large-scale studies of Cherenkov applications in radiotherapy. Methods: Four camera types, CMOS, CCD, ICCD and EMICCD, were tested to determine proficiency in the detection of Cherenkov signal in the clinical radiotherapy setting, and subsequent maximum supportable frame rate. Where possible, time-gating between the trigger signal from the LINAC and the intensifiers was implemented to detect signal with room lighting conditions comparable to patient treatment scenarios. A solid water phantom was imaged by the EM-ICCD and ICCD to evaluate the minimum number of accumulations-on-chip required for adequate Cherenkov detection, defined as >200% electron counts per pixel over background signal. Additionally, an ICCD and EM-ICCD were used clinically to image patients undergoing whole-breast radiation therapy, to understand the impact of the resolution limitation of the EM-ICCD. Results: The intensifier-coupled cameras performed best at imaging Cherenkov signal, even with room lights on, which is essential for patient comfort. The tested EM-ICCD was able to support single-shot imaging and frame rates of 30 fps, however, the current maximum resolution of 512 × 512 pixels was restricting. The ICCD used in current clinical trials was limited to 4.7 fps at a 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths (30% QE vs current 7%) promises 16 fps at the same resolution at lower cost than the EM-ICCD. Conclusion: The ICCD with the better red wavelength QE intensifier was determined to be the best suited commercial-off-the-shelf camera to detect real-time Cherenkov signal and provide the best potential for real-time display of radiation dose on the skin during treatment. Funding is from grants from the NIH numbers R01CA109558 and R21EB017559.

60 APPLIED LIFE SCIENCES↗

Synthesis and properties of ferromagnetic nanostructures embedded within a high-quality crystalline silicon matrix via ion implantation and nanocavity assisted gettering processes

Integrating magnetic functionalities with silicon holds the promise of developing, in the most dominant semiconductor, a paradigm-shift information technology based on the manipulation and control of electron spin and charge. Here, we demonstrate an ion implantation approach enabling the synthesis of a ferromagnetic layer within a defect free Si environment by exploiting an additional implant of hydrogen in a region deep below the metal implanted layer. Upon post-implantation annealing, nanocavities created within the H-implanted region act as trapping sites for gettering the implanted metal species, resulting in the formation of metal nanoparticles in a Si region of excellent crystal quality. This is exemplified by the synthesis of magnetic nickel nanoparticles in Si implanted with H{sup +} (range: ∼850 nm; dose: 1.5 × 10{sup 16 }cm{sup −2}) and Ni{sup +} (range: ∼60 nm; dose: 2 × 10{sup 15 }cm{sup −2}). Following annealing, the H implanted regions populated with Ni nanoparticles of size (∼10–25 nm) and density (∼10{sup 11}/cm{sup 2}) typical of those achievable via conventional thin film deposition and growth techniques. In particular, a maximum amount of gettered Ni atoms occurs after annealing at 900 °C, yielding strong ferromagnetism persisting even at room temperature, as well as fully recovered crystalline Si environments adjacent to these Ni nanoparticles. Furthermore, Ni nanoparticles capsulated within a high-quality crystalline Si layer exhibit a very high magnetic switching energy barrier of ∼0.86 eV, an increase by about one order of magnitude as compared to their counterparts on a Si surface or in a highly defective Si environment.

36 MATERIALS SCIENCE↗

Laboratory-Scale Coal-Derived Graphene Process (Final Report)

The Energy & Environmental Research Center (EERC) conducted a laboratory-scale coal-derived graphene (CDG) project focused on developing a technological process for making graphene from four U.S. domestic coal or coal wastes, including lignite from North Dakota, subbituminous coal from Wyoming, bituminous coal from Utah, and anthracite from Pennsylvania. The project was divided into two performance or budget periods (BPs), with BP1 comprising the up-front laboratory experiments to make graphene materials from coal beginning on May 1, 2020, to April 30, 2022. BP2 was conducted from May 1, 2022, to April 30, 2023, and was focused on analyzing the CDG process economic feasibility and the technical gaps for technological scale-up and commercialization. During this project, a few different coal-derived high-value products have been demonstrated, including graphite, graphene oxide (GO), reduced graphene oxide (rGO), and graphene quantum dots (GQDs). A new graphite microstructure was discovered and named “croissant graphite” because of the exterior morphological and textural resemblance to croissant food items sold in commercial groceries stores. The new graphite structure and the associated preparation from coal or coal waste feedstocks has been the subject of a U.S. patent application. The systematic experimental processes involving coal cleaning, upgrading, and conversion to high-value carbon products culminated into a developed upgraded coal-to-products (UCP) technology that is being pursued for potential fast-track commercialization, if funding is available. It is envisioned that commercialization of the UCP technology would increase consumption of U.S. domestic coals or coal wastes to make environmentally sustainable high-value products for the electronics industry, high-energy-storage applications, and clean energy technologies such as electric vehicle (EV) lithium-ion batteries (LIBs), for which graphite has become a critical mineral commodity. Croissant graphite microstructures, when observed by field emission scanning electron microscopy (FESEM), display wavy surface morphology and often grow from a base that is made of graphitized particles with honeycomb-like layers, which are believed to be graphene layers. While more studies are needed to fully ascertain the mechanisms of the croissant graphite microstructure formation, it is postulated that their growth may begin from curling of the graphene sheets into ribbon-like structures, and continuous growth and densification of the ribbon-like structures forms croissant microstructures. Additional studies are ongoing to evaluate the electrochemical performance of croissant graphite for LIB applications and to determine the experimental conditions necessary to tune on/off croissant formation so that it can be either optimized or suppressed depending on performance evaluation results. In addition to the discovery of croissant graphite, the graphitization process from the four coal ranks in general was successful. X-ray diffraction (XRD) analysis showed that the degree of graphitization (DoG) ranged from 12% to 80% in an early sample set, and further optimization on lignite coal produces a DoG of about 92%, which was spectacular to see as lignite is the lowest-rank coal. Thus, it is expected that the graphitization performance for higher-rank coals will be similar or better when optimized as well. The coal-derived graphite was used to make GO and rGO. Analytical characterization, e.g., by methods such as Raman spectroscopy, XRD, Fourier transform infrared (FTIR) spectroscopy and FESEM, showed that the sequence of converting the coal to graphite, exfoliating it to GO, and then chemically reducing the GO to rGO was successful. Although coal naturally contains aromatic compounds and some relatively small-sized condensed aromatic units, it does not contain graphene sheets. In the UCP process, the aromatic domains in the coals, particularly low-rank coals, are concentrated and condensed further into graphene sheets, which are ordered into a 3D stack during graphitization. The synthesized graphite is then unpacked by methods such as exfoliation to various graphene products. GQDs were synthesized from all four coal types, and their optical properties were demonstrated to be tunable by the coal precursor preprocessing treatments. In all four coal types, enhanced optical properties were observed for the produced GDQs with incremental improvements made to the coal precursors. GQDs produced from raw coal samples displayed lower ultraviolet–visible (UV–Vis) spectroscopy absorbance intensity compared to those obtained from cleaned and upgraded coal residues. The photoluminescence (PL) intensities also varied with pretreatment conditions and with the concentration of GQDs in aqueous solutions. GQDs obtained from anthracite show longer emission wavelengths and can be excited by visible light as opposed to GQDs derived from the other coal ranks. UV fluorescence 3D maps and spectra revealed that the emission wavelength at which the GQDs solutions display the highest intensity was slightly redshifted based on the coal precursor pretreatments. In low-rank coal (lignite and subbituminous) samples, two clusters were observed in the maps for GQDs, which may suggest that there are potentially two types of fluorophores in solution or two main size populations. The ability to tune the properties of GQDs based on processing methods can be exploited to make GQDs for various optical display or optoelectronics applications. The results also highlight the importance of removing coal-borne impurities to improve the quality of the coal precursor for preparation of graphene products. Coal and/or coal wastes preprocessing methods were developed and applied to clean and upgrade the coal precursors prior to graphitization and subsequent conversion to graphene products. The preprocessing methods involve high specific-gravity separations, mineral acid cleaning (no hydrofluoric acid), and subsequent upgrading by reducing the coal-borne heteroatom (nitrogen, sulfur, and oxygen) content using proprietary chemical agents. Analytical characterization revealed that the preprocessing steps were successful, with ash reductions that range from 38% to 80% and residual ash content that was below the 5 wt% initial target. Based on proximate and ultimate analysis, the heteroatom reduction reactions produced upgraded coal residues with the oxygen content reduced by 8% to 24%, with additional reductions in the nitrogen and sulfur contents. An initial assessment of the waste streams from the UCP process shows very small to negligible environmental impact due to CO 2 , NO x , and SO x because most process steps are performed under inert atmosphere with argon. Consequently, reactive oxygen environments that tend to create these species are avoided. The inorganic and potentially hazardous species are released into aqueous waste streams that are easy to handle for proper disposal. The liquid waste streams were found to contain low-level concentrations of rare-earth elements (REEs), which could be concentrated and recovered as value-added by-products. Additionally, the volatile and gaseous fractions from carbonization and heat treatment contain useful organic compounds that can also be recovered as potential valuable by-products. Thus, the UCP technology is considered an environmentally sustainable and promising emerging technology for making high-value products from coal and coal wastes, with potential additional value-added by-products. Analysis of potential markets for the coal-derived carbon products shows a strong demand in both niche market sectors and across a wide variety of other industrial sectors. Graphite is currently considered a critical mineral commodity that has a large and growing demand in the LIB industry for EV applications. Based on data from Fortune Business Insights (2022) and Marketwatch (2023) reports, the average global graphite market is projected to reach about 33 billion by 2028, growing at a compound annual growth rate (CAGR) of about 7%, with much of this growth expected to be in the LIB industry. GO and rGO have strong market potentials in various application areas, such as coatings for anticorrosion, anti-icing, and antimicrobial protection, thermal barriers, wear resistance, sensors, additive manufacturing such as 3D inks, and others. GQDs are the emerging key player in the bioimaging, photovoltaics, and light-emitting diodes (LEDs) applications, with the potential to replace traditional semiconductor quantum dots (SQDs), which are based on metallic systems that are more toxic and more expensive. Biomedical applications of GQDs are becoming more attractive because of low to no toxicity and extremely low cost compared to SQDs. The major challenges for scale-up and commercialization of coal-derived carbon products such as graphene vary from the inherent attributes of graphene itself to reluctance to accept graphene in new manufacturing processes because of the uncertainty of the unknown. The 2D nature of graphene materials with a thickness of one atom presents significant challenges to proper handling/processing, and process scale-up becomes difficult because it requires high-end, expensive equipment, even for routine handling and analysis for quality assurance and control. Pristine graphene can also be extremely difficult to work into other matrices, thus hindering downstream processibility, especially at large scale. Currently, the cost of graphene and graphene products is still high and presents an economic risk that tends to slow down investment in scaling up emerging technologies. The lack of a standard for graphene materials for quality assurance and quality control poses a great challenge not only for the markets but also for commercialization efforts. A first-look economic feasibility analysis of the UCP technology provided valuable information that suggests the UCP process would be feasible, especially when it is scaled to a pilot scale and could be more competitive at the full scale. Graphitization was found to be the most energy-consuming and most capital-intensive step in the overall process. In small laboratory- and bench-scale experiments, labor is a significant contributor to the total process costs. Although these energy, capital, and labor constraints contribute to a higher selling price for the product, a preliminary economic model suggests that the process would be feasible at large scale when the process is fully integrated, optimized, and automated.

01 COAL, LIGNITE, AND PEAT↗

αB-Crystallin. A Hybrid Solid-State/Solution-State NMR Investigation Reveals Structural Aspects of the Heterogeneous Oligomer

Atomic-level structural information on αB-Crystallin (αB), a prominent member of the small heat-shock protein family, has been a challenge to obtain due its polydisperse oligomeric nature. We show that magic-angle spinning solid-state NMR can be used to obtain high-resolution information on an ~580-kDa human αB assembled from 175-residue 20-kDa subunits. An ~100-residue α-crystallin domain is common to all small heat-shock proteins, and solution-state NMR was performed on two different α- crystallin domain constructs isolated from αB. In vitro, the chaperone-like activities of full-length αB and the isolated α-crystallin domain are identical. Chemical shifts of the backbone and C β resonances have been obtained for residues 64–162 (α-crystallin domain plus part of the C-terminus) in αB and the isolated α-crystallin domain by solid-state and solution-state NMR, respectively. Both sets of data strongly predict six β-strands in the α-crystallin domain. A majority of residues in the α-crystallin domain have similar chemical shifts in both solid-state and solution-state, indicating similar structures for the domain in its isolated and oligomeric forms. Sites of intersubunit interaction are identified from chemical shift differences that cluster to specific regions of the α-crystallin domain. Multiple signals are observed for the resonances of M68 in the oligomer, identifying the region containing this residue as existing in heterogeneous environments within αB. Evidence for a novel dimerization motif in the human α-crystallin domain is obtained by a comparison of (i) solid-state and solution-state chemical shift data and (ii) 1 H– 15 N heteronuclear single quantum coherence spectra as a function of pH. The isolated α-crystallin domain undergoes a dimer–monomer transition over the pH range 7.5–6.8. This steep pHdependent switch may be important for αB to function optimally (e.g., to preserve the filament integrity of cardiac muscle proteins such as actin and desmin during cardiac ischemia, which is accompanied by acidosis).

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics

Purpose: The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 {mu}m pixel pitch and 300 {mu}m thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 {mu}m pixel pitch and 600 {mu}m thick CsI phosphor). The linear system metrics such as modulation transfer function (MTF), noise power spectrum, and detection quantum efficiency (DQE) are commonly used to gauge the intrinsic detector performance in the detector plane. However, these linear system metrics do not provide information about the image receptor performance in a real system since they do not include the effects of other parameters such as focal spot distribution, scatter radiation, and geometric unsharpness, which may compromise detector performance characteristics. Use of generalized linear system metrics [generalized modulation transfer function (GMTF), generalized normalized noise power spectrum (GNNPS), and generalized detection quantum efficiency (GDQE)] that include these effects gives a more meaningful, complete, and appropriate evaluation of detector performance as part of the imaging system. Methods: A uniform head equivalent phantom was used to simulate realistic clinical parameters and x-ray spectra. The detector MTFs were measured using the slanted edge method and the focal spot MTFs were measured using a pinhole assembly. The scatter MTF was simulated and the scatter fraction was measured for a head-equivalent phantom. The generalized system metrics were calculated for different combinations of three choices of focal spots and three different magnifications with two different air-gaps. The performance of the MAF was also illustrated using stent images obtained with different focal spots under similar conditions. Results: Results for the generalized metrics provide a quantitative description of the performance of the imaging system for both detectors. This generalized analysis demonstrated that both detectors have similar imaging capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. Conclusions: This generalized performance analysis demonstrates the significance of focal spot size, magnification, and scatter on the system performance metrics (GMTF, GNNPS, and GDQE). Although the ideal detector performance characteristics of the MAF are not fully realized due to these other system factors, it still retains an advantage in DQE at high spatial frequencies over the FPD. Similar studies based on the generalized linear system metrics can serve as an efficient tool to evaluate total system capabilities under different realistic conditions to enable optimal design for specific imaging tasks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗