At least 1,495 records · Page 83

Diablo Canyon power plant digital process protection system replacement licensing experience using ISG-06 - 395

This paper provides a summary of the preparation of a License Amendment Request (LAR) for replacement of the existing Diablo Canyon Power Plant (DCPP) Eagle 21 digital Process Protection System (PPS) by Pacific Gas and Electric Company (PG and E) using US Nuclear Regulatory Commission (USNRC) Digital I and C (DI and C) Interim Staff Guidance (ISG) document ISG-06, Licensing Process . The USNRC has designated the LAR for the DCPP PPS replacement project as the pilot application for use of DI and C ISG-06. DI and C ISG-06, Revision 1, issued for use on January 19, 2011, describes the licensing process the NRC staff may use to review an LAR for a DI and C modification. The LAR for the replacement of the Eagle 21 PPS was submitted to the NRC on October 26, 2011, was accepted for review on January 13, 2012, and was approved on December 21, 2016. A more detailed review of the specific PPS replacement design including the Defense-In-Depth and Diversity approach is provided in a paper presented at the 2015 conference. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Crop protection in algae by exogenous terpene expression

The present disclosure relates to terpene synthases capable of producing terpenoids. In one instance, a transformed organism can include terpene synthases or vectors encoding such synthases. One method of employing such synthases and organisms includes protecting an algal culture, in which the produced terpenoid can act as a biocide.

Davis, Ryan Wesley↗

Solid state protective smart plug device

A wireless-controlled smart plug device and methods of use and operation, using a solid state switch to provide electrical power from an outlet to a load, and provide protection against overload, short circuit, ground, arc, or voltage surge faults. The switch includes a bidirectional semiconductor switch with two back-to-back connected transistors, such as silicon power MOSFETs, silicon insulated-gate bipolar transistors (IGBTs), silicon carbide (SiC) transistors, or gallium nitride (GaN) transistors, each configured to control the current flow from the electrical receptacle to the external electrical load.

Shen, Zheng↗

Systems and methods for optical sensor protection

The present disclosure relates to an optical sensor protection system. The system may have a sensor for receiving an incoming optical signal, a passive sensing and modulation component, and an active sensing and modulation subsystem. The passive sensing and modulation component is configured to sense when a first characteristic is associated with the incoming optical signal is present that adversely affects operation of the sensor, and redirects at least a portion of the incoming optical signal thereof away from the sensor to thus reduce an intensity of the incoming optical signal reaching the sensor. The sensor is located on an image plane downstream of the ISM subsystem, relative to a path of travel of the incoming optical signal. The active sensing and modulation subsystem has an active modulation component and is located upstream of the passive sensing and modulation component, relative to the path of travel of the incoming optical signal, and is also located on a conjugate image plane, and is configured to use the redirected portion of the incoming optical signal as feedback in controlling a modification of the incoming optical signal to reduce a risk of damage to the passive sensing and modulation component.

Panas, Robert Matthew↗

Fermilab PIP II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance.

Wu, J. [Fermilab] (ORCID:0000000344329521)↗

Evaluation of NETL’s Self-Healing Metallic Coating for Internal Corrosion Protection of Natural Gas Pipelines: Field Test

Steel pipelines are a safe, reliable, and affordable way to transport natural gas. However, the presence of impurities (e.g., water, carbon dioxide, and hydrogen sulfide) in the natural gas can cause internal corrosion, which can lead to pipeline leaks and failure. This paper reports on field tests of an innovative self-healing, corrosion-resistant, metallic coating developed at the National Energy Technology Laboratory (NETL) for protecting the interior surfaces of pipelines.

carbon dioxide (CO2)↗

Radiation protection for high energy implantation of light ions in a production environment

In recent years the irradiation of semiconductor devices by light ions with high energies has increasingly become a well-established method to adjust charge carrier lifetimes in semiconductor devices. To introduce this process into the end of frontend production environment several measures in terms of radiation safety will have to be obeyed. An overview on thresholds for particles induced gamma emission will be given, starting with the {sup 11}B(p,{gamma}){sup 12}C reaction at 163keV. The environment has to be shielded from gamma rays, therefore those implanters have to be situated in adequate enclosures. Calculations for specific implant energies are done to define the thicknesses of tool enclosures. A set of radiation detectors monitors the values at well-defined positions online and radiation values are fed into a superordinate system that is directly coupled to the main power supply of the implanter.

36 MATERIALS SCIENCE↗

Los Alamos Radiation Protection Internal Dosimetry (Bioassay) Pamphlet

A radionuclide intake happens when a radioactive material enters the body through inhalation or ingestion or through a wound. Because the radiation produced by some materials (such as plutonium, americium, uranium, and tritium) cannot leave the body, we look for the materials themselves in urine samples.

61 RADIATION PROTECTION AND DOSIMETRY↗