Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

A Comparative Study of Redox Mediators for Improved Performance of Li-Oxygen Batteries.

Redox meditators (RMs) are soluble catalysts located in an electrolyte that can improve the energy efficiency (reduced overpotential) and cyclability of Li-oxygen (Li-O-2) batteries. In this work, 20 RMs within a Li-O-2 system with dimethyl sulfoxide and tetraethylene glycol dimethyl ether electrolytes are studied and their electrochemical features such as redox potential, the separation of cathodic and anodic peaks, and their current intensities are measured using cyclic voltammetry (CV) experiments. Six RMs are selected as "primary" choices based on their electrochemical performance, and stability tests are then performed to examine their electrochemical responses after consecutive cycles. Moreover, galvanostatic cycling tests are performed within a Li-O-2 battery system assembled with selected six RMs for real case consistency investigations. It is found that results from CV to galvanostatic cycling tests are consistent for halides and organometallic RMs, where the former exhibit much higher stability. However, the organic RMs show high reversibility in CV but low in battery cycling results. Density functional theory calculations are carried out to gain more understanding of the stability and redox potentials of the RMs. This study provides comparative information to select the most reliable RMs for Li-O-2 batteries along with new fundamental understanding of their electrochemical activity and stability.

cyclic voltammetry↗

Comprehensive evaluation of commercially scalable atomic-layer-deposited alumina coating impact on full cell battery performance across varied test conditions

Atomic Layer Deposition (ALD) has emerged as a strategic enhancement method for lithium-ion battery (LIB) materials offering potential benefits and durability benefits for industrial battery production. However, the translation from laboratory achievements to commercial-scale applications has been limited. Here, this study aims to bridge this gap by comprehensively evaluating the effects of commercially scalable Al 2 O 3 ALD coatings using full pouch cell performance as a means to assess the ALD impact. We utilized large-scale slot-die coating techniques to ensure consistent electrode quality and tested four configurations of pouch cells to analyze the individual effects of ALD coating on anode and cathode electroactive materials. Our extensive testing matrix included long-term cycling, fast discharge, fast charge, leakage current, and high voltage tests. While at lower C-rates (<~1C), the influence of Al 2 O 3 coatings on cell performance is not significant. Fast charging conditions reveal that the anode ALD coating significantly enhances performance via a passivating effect, while on the cathode, it is detrimental, potentially due to increased resistance of the thin interfacial layer formed during the ALD processing. Leakage current and high-voltage tests show that the application of ALD coatings on either anode or cathode effectively minimizes side reactions at the electrode-electrolyte interface. Additionally, ALD coatings significantly mitigate concentrated and localized lithium plating on the anodes. These insights provide a valuable understanding of the potential of ALD technologies in LIB manufacturing to tailor cell performance, paving the way for safer, more efficient, and cost-effective battery solutions.

25 ENERGY STORAGE↗

Comparison of the PLTEMP code flow instability predictions with measurements made with electrically heated channels for the advanced test reactor.

When the University of Missouri Research Reactor (MURR) was designed in the 1960s the potential for fuel element burnout by a phenomenon referred to at that time as 'autocatalytic vapor binding' was of serious concern. This type of burnout was observed to occur at power levels considerably lower than those that were known to cause critical heat flux. The conversion of the MURR from HEU fuel to LEU fuel will probably require significant design changes, such as changes in coolant channel thicknesses, that could affect the thermal-hydraulic behavior of the reactor core. Therefore, the redesign of the MURR to accommodate an LEU core must address the same issues of fuel element burnout that were of concern in the 1960s. The Advanced Test Reactor (ATR) was designed at about the same time as the MURR and had similar concerns with regard to fuel element burnout. These concerns were addressed in the ATR by two groups of thermal-hydraulic tests that employed electrically heated simulated fuel channels. The Croft (1964), Reference 1, tests were performed at ANL. The Waters (1966), Reference 2, tests were performed at Hanford Laboratories in Richland Washington. Since fuel element surface temperatures rise rapidly as burnout conditions are approached, channel surface temperatures were carefully monitored in these experiments. For self-protection, the experimental facilities were designed to cut off the electric power when rapidly increasing surface temperatures were detected. In both the ATR reactor and in the tests with electrically heated channels, the heated length of the fuel plate was 48 inches, which is about twice that of the MURR. Whittle and Forgan (1967) independently conducted tests with electrically heated rectangular channels that were similar to the tests by Croft and by Walters. In the Whittle and Forgan tests the heated length of the channel varied among the tests and was between 16 and 24 inches. Both Waters and Whittle and Forgan show that the cause of the fuel element burnout is due to a form of flow instability. Whittle and Forgan provide a formula that predicts when this flow instability will occur. This formula is included in the PLTEMP/ANL code.Error! Reference source not found. Olson has shown that the PLTEMP/ANL code accurately predicts the powers at which flow instability occurs in the Whittle and Forgan experiments. He also considered the electrically heated tests performed in the ANS Thermal-Hydraulic Test Loop at ORNL and report by M. Siman-Tov et al. The purpose of this memorandum is to demonstrate that the PLTEMP/ANL code accurately predicts the Croft and the Waters tests. This demonstration should provide sufficient confidence that the PLTEMP/ANL code can adequately predict the onset of flow instability for the converted MURR. The MURR core uses light water as a coolant, has a 24-inch active fuel length, downward flow in the core, and an average core velocity of about 7 m/s. The inlet temperature is about 50 C and the peak outlet is about 20 C higher than the inlet for reactor operation at 10 MW. The core pressures range from about 4 to about 5 bar. The peak heat flux is about 110 W/cm{sup 2}. Section 2 describes the mechanism that causes flow instability. Section 3 describes the Whittle and Forgan formula for flow instability. Section 4 briefly describes both the Croft and the Waters experiments. Section 5 describes the PLTEMP/ANL models. Section 6 compares the PLTEMP/ANL predictions based on the Whittle and Forgan formula with the Croft measurements. Section 7 does the same for the Waters measurements. Section 8 provides the range of parameters for the Whittle and Forgan tests. Section 9 discusses the results and provides conclusions. In conclusion, although there is no single test that by itself closely matches the limiting conditions in the MURR, the preponderance of measured data and the ability of the Whittle and Forgan correlation, as implemented in PLTEMP/ANL, to predict the onset of flow instability for these tests leads one to the conclusion that the same method should be able to predict the onset of flow instability in the MURR reasonably well.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of an RPM based on Gd-lined plastic scintillator for neutron and gamma detection [ANIMMA--2015-IO-372]

A Radiation Portal Monitor (RPM) was developed by the Istituto Nazionale di Fisica Nucleare (INFN) and Ansaldo Nucleare (ANN) within the FP7 SCINTILLA European project. The system was designed to detect both gamma and neutron radiation with a single technology. It is conceived to monitor vehicle and cargo containers in transits across borders or ports, to find radioactive elements and to avoid illegal trafficking of strategic nuclear materials. The system is based on a {sup 3}He-free neutron detection technology using plastic scintillators coupled to Gadolinium to detect and discriminate gamma from neutron signals. During the 3 years of the SCINTILLA project the construction and test of the first two prototypes drove the definition of the final layout of a full RPM system consisting of two twin pillars as a portal for vehicle and cargo container scan. A custom System Control Software (SCS) manages the electronics of the RPM, the ancillary devices and the data analysis. The combination of the detector layout and of the software functionalities enables both to distinguish neutrons and gammas and to identify the energy range of a detected gamma source. The system was initially characterized via static tests with gamma and neutron sources in the INFN laboratory. These measurements were used to calibrate the detector, evaluate the response of the single pillars as well as of the full system, and optimize the RPM configuration and discrimination algorithm. During this phase, specific tests were performed to study the stability over time of the system, monitoring the measured the neutron and gamma count rates over periods of several weeks. The results allow us to demonstrate the reliability and robustness of the RPM. In a second time the RPM performance was studied via dynamic tests performed during the SCINTILLA test and benchmark campaigns. These measurements took place in the JRC ITRAP+10 facility at Ispra (Varese-Italy). The laboratory is equipped with an experimental set-up for dynamic tests of multiple systems according to international standards. The performed measurements utilized radioactive sources with activities selected according to ANSI and IEC standards to test the detector alarm performances in terms of gamma and neutron response, sensitivity to high gamma fields, sensitivity to moderated neutron sources as well as false alarm rates (FAR). In addition, the RPM was tested in challenging configurations exceeding the requirements set by international standards to determine the real limits of the system. The results obtained during these campaigns demonstrated that the system detection efficiency is not only compliant to international standards for its category, but often exceeds them, demonstrating the validity of the chosen technology and of the implemented layout. The positive performance also showed the effectiveness of the SCS and of its functionalities. To further demonstrate the system capabilities, a test in a real-life environment of the RPM is planned to happen in a near future by installing the detectors in a seaport. In this presentation I will give an overview of the RPM characteristics, of its performances as determined in the test campaign mentioned above and of future plans, to demonstrate how this technology can be an effective choice for the realization of {sup 3}He-free RPM detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly

DOE manages over 300 types of SNF, most of which are located at the INL site. “Road-ready dry storage” is a management concept where SNF is packaged into dry, sealed canisters, which are then placed in on-site storage in anticipation of later removal. The Idaho Cleanup Project and INL are collaborating on the Road-Ready Capability Demonstration Project, which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE SNF for road-ready dry storage. In support of establishing a large-scale road-ready dry storage program at the INL site, the demonstration will package a select amount of DOE-managed SNF into DOE Standard Canisters. The closure process for the DOE Standard Canisters will include fuel and basket loading, welding, inspection, leak testing, and if needed, repair. As a follow-up to previous discussion on the design of the DOE Closure Leak Test Assembly, this report describes recent fabrication and testing efforts performed at INL. DOE Standard Canisters are sealed by two sequential gas tungsten arc welds. Both are performed by remotely operated and semi-autonomous welding systems. The first weld is a circumferential pipe weld that completes assembly of the canister body and lid assembly. The second and final closure weld connects the vent plug to the vent port with an identical butt joint to the circumferential pipe weld. After the second weld is performed on the vent port, these welds are helium leak tested using an inside-out technique. In addition to the commercially available vacuum and leak detector systems, the DOE Standard Canister Closure Leak Test Assembly was designed for both remote and manual operation. This report describes fabrication and performance testing associated with the inside-out technique. INL staff designed and tested systems to accomplish these tasks. Hardware fabrication occurred at INL facilities. Forthcoming work includes design optimization, integration to existing systems, and implementation to packaging demonstration operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bench-Scale Testing and Process Performance Projections of CO2 Capture by CO2–Binding Organic Liquids (CO2BOLs) With and Without Polarity-Swing-Assisted Regeneration

This manuscript provides a detailed analysis of a continuous flow, bench scale study of the CO2BOL solvent platform with and without its Polarity Swing Assisted Regeneration (PSAR). This study encompassed four months of continuous flow testing of a candidate CO2BOL with a thermal regeneration and PSAR regeneration using decane antisolvent. In both regeneration schemes, steady state capture of >90 %CO2 was achieved using simulated flue gas at acceptable L/G ratios. Aspen Plus™ modeling was performed to assess process performance compared to previous equilibrium performance projections. This paper also includes net power projections, and comparisons to DOE’s Case 10 amine baseline.

Zheng, Feng↗

Assessing and Testing Hydrokinetic Turbine Performance and Effects on Open Channel Hydrodynamics: An Irrigation Canal Case Study.

Hydrokinetic energy from flowing water in open channels has the potential to support local electricity needs with lower regulatory or capital investment than impounding water with more conventional means. MOU agencies involved in federal hydropower development have identified the need to better understand the opportunities for hydrokinetic (HK) energy development within existing canal systems that may already have integrated hydropower plants. This document provides an overview of the main considerations, tools, and assessment methods, for implementing field tests in an open-channel water system to characterize current energy converter (CEC) device performance and hydrodynamic effects. It describes open channel processes relevant to their HK site and perform pertinent analyses to guide siting and CEC layout design, with the goal of streamlining the evaluation process and reducing the risk of interfering with existing uses of the site. This document outlines key site parameters of interest and effective tools and methods for measurement and analysis with examples drawn from the Roza Main Canal, in Yakima, WA to illustrate a site application.

13 HYDRO ENERGY↗

JV Task 119 - Effects of Aging on Treated Activated Carbons

For both the United States and Canada, testing has been under way for electric utilities to find viable and economical mercury control strategies to meet pending future mercury emission limits. The technology that holds the most promise for mercury control in low-chlorine lignite to meet the needs of the Clean Air Act in the United States and the Canada-Wide Standards in Canada is injection of treated activated carbon (AC) into the flue gas stream. Most of the treated carbons are reported to be halogenated, often with bromine. Under a previous multiyear project headed by the Energy & Environmental Research Center (EERC), testing was performed on a slipstream unit using actual lignite-derived flue gas to evaluate various sorbent technologies for their effectiveness, performance, and cost. Testing under this project showed that halogenated ACs performed very well, with mercury capture rates often {ge} 90%. However, differences were noted between treated ACs with respect to reactivity and capacity, possibly as a result of storage conditions. Under certain conditions (primarily storage in ambient air), notable performance degradation had occurred in mercury capture efficiency. Therefore, a small exploratory task within this project evaluated possible differences resulting from storage conditions and subsequent effects of aging that might somehow alter their chemical or physical properties. In order to further investigate this potential degradation of treated (halogenated) ACs, the EERC, together with DOE's National Energy Technology Laboratory, the North Dakota Industrial Commission (NDIC), the Electric Power Research Institute (EPRI), SaskPower, and Otter Tail Power Company, assessed the aging effects of brominated ACs for the effect that different storage durations, temperatures, and humidity conditions have on the mercury sorption capacity of treated ACs. No aging effects on initial capture activity were observed for any carbons or conditions in the investigation. As measured by the 50% breakthrough time, no changes in capacity were observed for Norit LH samples stored frozen and likely none for Norit LH samples stored under high humidity conditions. The major aging effects on capacity for the EERC brominated sample were seen as a decrease in capacity during the first week of storage under high humidity conditions. Storage of the Norit LH and the EERC 5% brominated samples under low humidity conditions resulted in slightly improved capacities. Storage of the 15% brominated sample under high humidity conditions also improved the capacity. Surface analysis using x-ray photoelectron spectroscopy (XPS) showed some migration of bromine to and from the surface occurred during storage, although no net loss of bromine was observed. The migration to the surface in the case of the 15% brominated carbon correlates with the increased capacity observed for this sample. The XPS elemental speciation data for the EERC brominated carbons showed a trend toward more bromide being formed at the expense of covalent bromine during storage. This was especially great for the 15% and the 5% stored in low humidity. The Norit LH samples did not show this increase in bromide concentration. This is consistent with the lack of change in capacity for the Norit LH during storage. The carbon speciation data showed generally more oxidization of carbon surfaces with storage, especially formation of carboxylate groups. The least increase in carboxylate groups was seen for the Norit LH stored under low humidity, which correlates with its increased capacity. In conclusion, the observed changes in surface chemistry can be related to the minimal changes in capacity observed, but the factors operate in different directions, so the relationships are complex. High-quality x-ray absorption fine structure spectra were obtained for most of the samples. Significant changes were observed in the x-ray absorption near edge structure and extended x-ray absorption fine structure spectra of the stored carbons, but proved difficult to interpret and correlate with structural changes.

01 COAL, LIGNITE, AND PEAT↗

Methods for Quantifying the Uncertainties of LSIT Test Parameters, Test Results, and Full-Scale Mixing Performance Using Models Developed from Scaled Test Data

This report discusses the statistical methods for quantifying uncertainties in 1) test responses and other parameters in the Large Scale Integrated Testing (LSIT), and 2) estimates of coefficients and predictions of mixing performance from models that relate test responses to test parameters. Testing at a larger scale has been committed to by Bechtel National, Inc. and the U.S. Department of Energy (DOE) to “address uncertainties and increase confidence in the projected, full-scale mixing performance and operations” in the Waste Treatment and Immobilization Plant (WTP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Standardized Analysis Process Using Digital Image Correlation to Calculate In Situ Cladding Strain from Modified Burst Tests for Fuel Performance Code Validation

Historical data collection on nuclear fuel cladding materials has focused on generating a statistically significant amount of data to assess the material and its failure behavior. Furthermore, data generated to support material model and failure criteria development were previously posttest evaluations, so a large number of tests was required to gain new understanding. A way to expedite this process is to develop techniques capable of generating large, high-fidelity data sets from a single test with lower uncertainty or quantified uncertainty. One such example of this approach is Oak Ridge National Laboratory’s use of modified burst tests (MBTs) to analyze the mechanical behavior and failure conditions of cladding during a simulated reactivity-initiated accident (RIA). Each test incorporates digital image correlation (DIC) analysis techniques that are used to assess the accumulated strain in situ, as well as eventual cladding failure. This work has been fruitful in defining strain-to-failure conditions for materials like silicon carbide (SiC) fiber–reinforced/SiC matrix composite tubes (SiC/SiC), iron-chromium-aluminum (FeCrAl) alloy tubes, and chromium-coated Zircaloy-4 tubes. However, there are numerous DIC software available, including open-source and proprietary software. The different DIC software use various algorithms to process images and calculate displacement values. Using these different software and algorithms can lead to varying results, and perhaps larger-than-expected uncertainties. In the present study, previously published MBT data encompassing a variety of test conditions were reanalyzed with two different DIC software to assess the variance in the calculated strain results. The data consisted of SiC/SiC, FeCrAl, and chromium-coated Zircaloy-4 tubes. Plots of the calculated strains during the transient revealed good agreement between the two DIC software. The average root-mean-square errors between the two software was 0.20% strain, which is slightly larger than a previously reported error value for these tests. In conclusion, this variance in results is low enough that this analysis method can be used for code validation.

Reactivity-initiated accident↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

Test Methods for Cementitious Seal Materials for Borehole Disposal - 17352

The Nuclear and Energy Research Institute (IPEN-CNEN/SP) in Sao Paulo-Brazil, is considering borehole disposal of disused sealed radioactive sources (DSRS), which were used in smoke detectors, lightning arresters, radiotherapy, industrial gauges, irradiators, and other applications. The current IPEN concept of borehole is a modified BOSS system developed by the International Atomic Energy Agency (IAEA). It differs from the IAEA's design in that the disposal zone is below 300 m, and the DSRS are placed directly in the disposal packages constituted of stainless steel containers with 1.5 L capacity. A borehole drilled through sediment and granite, stabilized with stainless steel casing and cement grout is proposed for the conceptual model. Standard cement-material test methods and performance specific test methods, including accelerated aging methods, are needed for modeling the performance of the candidate cementitious grouts. A cross-disciplinary team from the USA Savannah River National laboratory is providing technical assistance to IPEN in this performance assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring Hilbert space on a budget: Novel benchmark set and performance metric for testing electronic structure methods in the regime of strong correlation

This work explores the ability of classical electronic structure methods to efficiently represent (compress) the information content of full configuration interaction (FCI) wave functions. We introduce a benchmark set of four hydrogen model systems of different dimensionalities and distinctive electronic structures: a 1D chain, a 1D ring, a 2D triangular lattice, and a 3D close-packed pyramid. To assess the ability of a computational method to produce accurate and compact wave functions, we introduce the accuracy volume, a metric that measures the number of variational parameters necessary to achieve a target energy error. Using this metric and the hydrogen models, we examine the performance of three classical deterministic methods: (i) selected configuration interaction (sCI) realized both via an a posteriori (ap-sCI) and variational selection of the most important determinants, (ii) an a posteriori singular value decomposition (SVD) of the FCI tensor (SVD-FCI), and (iii) the matrix product state representation obtained via the density matrix renormalization group (DMRG). We find that the DMRG generally gives the most efficient wave function representation for all systems, particularly in the 1D chain with a localized basis. For the 2D and 3D systems, all methods (except DMRG) perform best with a delocalized basis, and the efficiency of sCI and SVD-FCI is closer to that of DMRG. For larger analogs of the models, the DMRG consistently requires the fewest parameters but still scales exponentially in 2D and 3D systems, and the performance of SVD-FCI is essentially equivalent to that of ap-sCI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient Testing of Nuclear Fuels Performed in the Original Operation of TREAT (First Edition)

This report provides summary information on a selected set of key historic experiment series which were performed in the Transient Reactor Test Facility (TREAT) during its original operation from 1959-1994. The selected experiments are intended to illustrate the diversity in experiments which have been performed, and the range in capabilities of the TREAT reactor. Knowledge of those prior experiments provides a foundation for qualification and safety evaluation of numerous fuel forms already tested in TREAT, planning and designing new future tests, and for future TREAT operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CATHARE calculations of Phenix ultimate natural convection test

The Phenix Sodium cooled Fast Reactor (SFR) started operation in 1973 and it was stopped in 2009. Before the reactor was definitively shutdown, in order to collect experimental data for code assessments in the frame of Generation IV an intensive program of ultimate tests was set up. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip on one secondary pump and a natural convection test in the primary circuit. The natural convection test has been used for an international benchmark on system codes in the frame of the IAEA. The CATHARE code - initially developed for water cooled reactors and now extended for safety analyses for other kinds of reactors, including Sodium Fast Reactor - was used by CEA for this benchmark. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. Main test results are also briefly reminded including the evolution of the core and the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The main developments to perform CATHARE SFR computations and the strategy of system code assessment are presented. Then the CATHARE modelling of Phenix reactor is depicted and the various assumptions are pointed out. CATHARE encountered no problem to predict the initial nominal state. Afterwards, the whole transient scenario is calculated and CATHARE calculations are compared to the Phenix measurements. The global trend is rather well predicted by the CATHARE code. Nevertheless, due to complex flow phenomena occurring in large plena and components, the system code encountered physical limitations, leading to remaining discrepancies between code prediction and plant data. Various sensitivity calculations are presented and they bring partial answers. Additional analyses are in progress to understand more deeply the complex 3D phenomena involved during the different phases of the natural convection test. Additional work for coupling CATHARE system code and TRIO-U CFD code is in progress and will bring useful information to better understand the physical phenomena involved during the natural convection test and to improve system modeling for future SFR safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-P-39: End-To-End Validation of a 6 MV High Dose Rate Photon Beam, Configured for Eclipse AAA Algorithm Using Golden Beam Data, for SBRT Treatments Using RapidArc

Purpose: To use end-to-end testing to validate a 6 MV high dose rate photon beam, configured for Eclipse AAA algorithm using Golden Beam Data (GBD), for SBRT treatments using RapidArc. Methods: Beam data was configured for Varian Eclipse AAA algorithm using the GBD provided by the vendor. Transverse and diagonals dose profiles, PDDs and output factors down to a field size of 2×2 cm2 were measured on a Varian Trilogy Linac and compared with GBD library using 2% 2mm 1D gamma analysis. The MLC transmission factor and dosimetric leaf gap were determined to characterize the MLC in Eclipse. Mechanical and dosimetric tests were performed combining different gantry rotation speeds, dose rates and leaf speeds to evaluate the delivery system performance according to VMAT accuracy requirements. An end-to-end test was implemented planning several SBRT RapidArc treatments on a CIRS 002LFC IMRT Thorax Phantom. The CT scanner calibration curve was acquired and loaded in Eclipse. PTW 31013 ionization chamber was used with Keithley 35617EBS electrometer for absolute point dose measurements in water and lung equivalent inserts. TPS calculated planar dose distributions were compared to those measured using EPID and MapCheck, as an independent verification method. Results were evaluated with gamma criteria of 2% dose difference and 2mm DTA for 95% of points. Results: GBD set vs. measured data passed 2% 2mm 1D gamma analysis even for small fields. Machine performance tests show results are independent of machine delivery configuration, as expected. Absolute point dosimetry comparison resulted within 4% for the worst case scenario in lung. Over 97% of the points evaluated in dose distributions passed gamma index analysis. Conclusion: Eclipse AAA algorithm configuration of the 6 MV high dose rate photon beam using GBD proved efficient. End-to-end test dose calculation results indicate it can be used clinically for SBRT using RapidArc.

60 APPLIED LIFE SCIENCES↗

Pt-functionalized reduced graphene oxide for excellent hydrogen sensing at room temperature

Cost effective and faster detection of H{sub 2} has always remained a challenge. We report synthesis of reduced graphene oxide (RGO)–Pt composite and its application as highly sensitive and selective H{sub 2} sensors at room temperature. Four samples by varying the ratio of RGO and Pt were prepared to test their sensing performance. The tests were carried out in inert (N{sub 2}) ambience as well as air ambience. It was observed that the RGO:Pt (1:3) 1 h reduced sample demonstrated the best H{sub 2} sensing performance in terms of sensitivity, response time, and recovery time at room temperature. Its response varied from ∼19% (200 ppm) to 57% (5000 ppm) against H{sub 2} in air ambience. Also, the response time and recovery time of the RGO:Pt (1:3) sample were found to be as fast as 65 s and 230 s against 5000 ppm, respectively, in air ambience. In N{sub 2} ambience, the RGO:Pt (1:3) sample demonstrated the best response of −97% (500 ppm), but its recovery was found to be poor. The RGO–Pt composite formation was verified by high resolution transmission electron microscopy and X-ray photoelectron spectroscopy. The detailed physics behind the sensing mechanisms have been explained and experimentally verified in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗