Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Acoustically-tuned optical spectrometer

Lens arrangement corrects for aberrations and gives resolution of 0.7 seconds of arc. In spectrometer, light from telescope is relayed by doublet lens to acoustically tuned optical filter. Selected wavelengths are relayed by triplet lens to charge coupled device camera. Intervening cylindrical lens, tilted at 12 degree angle, corrects for astigmatism and coma introduced by two element birefringent crystal in filter.

Sklar, E.↗

Alteration in CM carbonaceous chondrites inferred from modal and chemical variations in matrix

The modal abundance of matrix in CM chondrites appears to vary from 57-85 vol%. The concentrations of volatile elements that should occur in matrix remain approximately constant despite differences in the proportions of matrix, suggesting that the differing matrix contents may not be real primary variations but are optical effects due to aqueous alteration processes that make other petrologic components unrecognizable. Apparent matrix content can be used as a qualitative measure of the degree of alteration experienced by each CM chondrite. Fe/Si ratios in matrices decrease progressively with increasing alteration due to the formation of new phyllosilicate phases with higher Mg/Fe ratios and optically recognizable opaque minerals that are not counted as matrix. The aqueous alteration process in CM chondrites appears to have been largely isochemical if the bulk meteorites are considered as the reacting systems, although depletion patterns and isotopic anomalies indicate open-system behavior for a few highly mobile components.

Mcsween, H. Y., Jr.↗

On the application of optical-fiber image scramblers to astronomical spectroscopy

Single, step-index optical fibers, when properly employed, can function as optically efficient image scramblers. Their use as optical feeds for astronomical slit spectrographs can reduce zonal error levels in those instruments by orders of magnitude. As a consequence, the application of optical-fiber couplers to new and existing spectrographs may greatly increase the wavelength metric quality of conventional astronomical spectroscopy. The optical efficiencies of fiber couplers of a few tens of meters in length can be comparable to those of typical coude mirror trains in the visible portions of the spectrum. Elements of the design of fiber couplers are illustrated by discussion of a currently operational instrument.

Heacox, W. D.↗

Effect of LID (Registered) processing on the microstructure and mechanical properties of Ti-6Al-4V and Ti-6Al-2Sn-4Zr-2Mo titanium foil-gauge materials

A study was undertaken to determine the mechanical properties and microstructures resulting from Liquid Interface Diffusion (LID -Registered) processing of foil-gauge specimens of Ti-6Al-4V and Ti-6Al-2Sn-4Zr-2Mo coated with varying amounts of LID material. In addition, the effects of various elevated temperature exposures on the concentration profiles of the LID alloying elements were investigated, using specimens with a narrow strip of LID material applied to the surface. Room and elevated temperature tensile properties were determined for both coated and uncoated specimens. Optical microscopy was used to examine alloy microstructures, and scanning electron microscopy to examine fracture surface morphologies. The chemical concentration profiles of the strip-coated specimens were determined with an electron microprobe.

Balckburn, Linda B.↗

The ultraviolet emission properties of five low-redshift active galactic nuclei at high signal-to-noise ratio and spectral resolution

We analyze the ultraviolet (UV) emission line and continuum properties of five low-redshift active galactic nuclei (four luminous quasars: PKS 0405-123, H1821 + 643, PG 0953 + 414, and 3C 273, and one bright Seyfert 1 galaxy: Mrk 205). The HST spectra have higher signal-to-noise ratios (typically approximately 60 per resolution element) and spectral resolution (R = 1300) than all previously published UV spectra used to study the emission characteristics of active galactic nuclei. We include in the analysis ground-based optical spectra covering H beta and the narrow (O III) lambda lambda 4959, 5007 doublet. New results are obtained and presented.

Laor, Ari↗

Implementation of Nonlinear Control Laws for an Optical Delay Line

This paper discusses the implementation of a globally stable nonlinear controller algorithm for the Real-Time Interferometer Control System Testbed (RICST) brassboard optical delay line (ODL) developed for the Interferometry Technology Program at the Jet Propulsion Laboratory. The control methodology essentially employs loop shaping to implement linear control laws. while utilizing nonlinear elements as means of ameliorating the effects of actuator saturation in its coarse, main, and vernier stages. The linear controllers were implemented as high-order digital filters and were designed using Bode integral techniques to determine the loop shape. The nonlinear techniques encompass the areas of exact linearization, anti-windup control, nonlinear rate limiting and modal control. Details of the design procedure are given as well as data from the actual mechanism.

Hench, John J.↗

Analysis and Verification of HET 1 m Mirror Deflections Due to Edge Sensor Loading

The ninety-one 1 m mirror segments which comprise the McDonald Observatory Hobby Eberly Telescope (HET) primary mirror have been observed to drift out of alignment in an unpredictable manner in response to time variant temperature deviations. A Segment Alignment Maintenance System (SAMS) is being developed to detect and correct this segment-to-segment drift using sensors mounted at the edges of the mirror segments. However, the segments were not originally designed to carry the weight of edge sensors. Thus, analyses and tests were conducted as part of the SAMS design to estimate the magnitude and shape of the edge sensor induced deformations as well as the resultant optical performance. Interferometric testing of a 26 m radius of curvature HET mirror segment was performed at the Marshall Space Flight Center using several load conditions to verify the finite element analyses.

Stallcup, Michael A.↗

A Comprehensive Plan for the Long-Term Calibration and Validation of Oceanic Biogeochemical Satellite Data

The primary objective of this planning document is to establish a long-term capability and validating oceanic biogeochemical satellite data. It is a pragmatic solution to a practical problem based primarily o the lessons learned from prior satellite missions. All of the plan's elements are seen to be interdependent, so a horizontal organizational scheme is anticipated wherein the overall leadership comes from the NASA Ocean Biology and Biogeochemistry (OBB) Program Manager and the entire enterprise is split into two components of equal sature: calibration and validation plus satellite data processing. The detailed elements of the activity are based on the basic tasks of the two main components plus the current objectives of the Carbon Cycle and Ecosystems Roadmap. The former is distinguished by an internal core set of responsibilities and the latter is facilitated through an external connecting-core ring of competed or contracted activities. The core elements for the calibration and validation component include a) publish protocols and performance metrics; b) verify uncertainty budgets; c) manage the development and evaluation of instrumentation; and d) coordinate international partnerships. The core elements for the satellite data processing component are e) process and reprocess multisensor data; f) acquire, distribute, and archive data products; and g) implement new data products. Both components have shared responsibilities for initializing and temporally monitoring satellite calibration. Connecting-core elements include (but are not restricted to) atmospheric correction and characterization, standards and traceability, instrument and analysis round robins, field campaigns and vicarious calibration sites, in situ database, bio-optical algorithm (and product) validation, satellite characterization and vicarious calibration, and image processing software. The plan also includes an accountability process, creating a Calibration and Validation Team (to help manage the activity), and a discussion of issues associated with the plan's scientific focus.

Hooker, Stanford B.↗

Thermal Design, Test and Analysis of PharmaSat, a Small Class D Spacecraft with a Biological Experiment

Small spacecraft have been increasing in popularity because of their low cost, short turnaround and relative efficiency. In the past, small spacecraft have been primarily used for technology demonstrations, but advances in technology have made the miniaturization of space science possible [1,2]. PharmaSat is a low cost, small three cube size spacecraft, with a biological experiment on board, built at NASA (National Aeronautics and Space Administration) Ames Research Center. The thermal design of small spacecraft presents challenges as their smaller surface areas translate into power and thermal constraints. The spacecraft is thermally designed to run colder in the Low Earth Orbit space environment, and heated to reach the temperatures required by the science payload. The limited power supply obtained from the solar panels on small surfaces creates a constraint in the power used to heat the payload to required temperatures. The pressurized payload is isolated with low thermally conductance paths from the large ambient temperature changes. The thermal design consists of different optical properties of section surfaces, Multi Layer Insulation (MLI), low thermal conductance materials, flexible heaters and thermal spreaders. The payload temperature is controlled with temperature sensors and flexible heaters. Finite Element Analysis (FEA) and testing were used to aid the thermal design of the spacecraft. Various tests were conducted to verify the thermal design. An infrared imager was used on the electronic boards to find large heat sources and eliminate any possible temperature runaways. The spacecraft was tested in a thermal vacuum chamber to optimize the thermal and power analysis and qualify the thermal design of the spacecraft for the mission.

Diaz-Aguado, Millan F.↗

Simulations of Deep Galaxy Fields I: Monte-Carlo Simulations of Optical and Near Infrared Counts

Monte-Carlo simulations of three dimensional galaxy distributions are performed, following the prescription of Chokishi & Wright (1988), to study the photometric properties of evolving galaxy populations in the optical and near infrared bands to high redshifts. Galaxies are spatially distributed according to the spatial two point correlation function in a range of cluster to field environments andin volume elements appropriate to the cosmological model under consideration. Details of individual galaxy properties, including luminosities, morphologies, disk-to-bulge ratios, and size distributions are simulated to match local observed galaxy properties. Galaxies have evolving gas fraction, metallicity and spectral energy distributions that include both stellar emission and internal dust absorption and re-emission. The simulations result in noiseless two dimensional galaxy distributions on the sky that canbe compared to the observed deep images in the blue and near-infrared bands...

faint↗

A TEOM (tm) particulate monitor for comet dust, near Earth space, and planetary atmospheres

Scientific missions to comets, near earth space, and planetary atmospheres require particulate and mass accumulation instrumentation for both scientific and navigation purposes. The Rupprecht & Patashnick tapered element oscillating microbalance can accurately measure both mass flux and mass distribution of particulates over a wide range of particle sizes and loadings. Individual particles of milligram size down to a few picograms can be resolved and counted, and the accumulation of smaller particles or molecular deposition can be accurately measured using the sensors perfected and toughened under this contract. No other sensor has the dynamic range or sensitivity attained by these picogram direct mass measurement sensors. The purpose of this contract was to develop and implement reliable and repeatable manufacturing methods; build and test prototype sensors; and outline a quality control program. A dust 'thrower' was to be designed and built, and used to verify performance. Characterization and improvement of the optical motion detection system and drive feedback circuitry was to be undertaken, with emphasis on reliability, low noise, and low power consumption. All the goals of the contract were met or exceeded. An automated glass puller was built and used to make repeatable tapered elements. Materials and assembly methods were standardized, and controllers and calibrated fixtures were developed and used in all phases of preparing, coating and assembling the sensors. Quality control and reliability resulted from the use of calibrated manufacturing equipment with measurable working parameters. Thermal and vibration testing of completed prototypes showed low temperature sensitivity and high vibration tolerance. An electrostatic dust thrower was used in vacuum to throw particles from 2 x 10(exp 6) g to 7 x 10(exp -12) g in size. Using long averaging times, particles as small as 0.7 to 4 x 10(exp 11) g were weighted to resolutions in the 5 to 9 x 10(exp -13) g range. The drive circuit and optics systems were developed beyond what was anticipated in the contract, and are now virtually flight prototypes. There is already commercial interest in the developed capability of measuring picogram mass losses and gains. One area is contamination and outgassing research, both measuring picogram losses from samples and collecting products of outgassing.

Source record↗

Cascaded clocks measurement and simulation findings

This paper will examine aspects related to network synchronization distribution and the cascading of timing elements. Methods of timing distribution have become a much debated topic in standards forums and among network service providers (both domestically and internationally). Essentially these concerns focus on the need to migrate their existing network synchronization plans (and capabilities) to those required for the next generation of transport technologies (namely, the Synchronous Digital Hierarchy (SDH), Synchronous Optical Networks (SONET), and Asynchronous Transfer Mode (ATM). The particular choices for synchronization distribution network architectures are now being evaluated and are demonstrating that they can indeed have a profound effect on the overall service performance levels that will be delivered to the customer. The salient aspects of these concerns reduce to the following: (1) identifying that the devil is in the details of the timing element specifications and the distribution of timing information (i.e., small design choices can have a large performance impact); (2) developing a standardized method of performance verification that will yield unambiguous results; and (3) presentation of those results. Specifically, this will be done for two general cases: an ideal input, and a noisy input to a cascaded chain of slave clocks.

Chislow, Don↗

An optical model for composite nuclear scattering

The optical model of composite particle scattering is considered and compared to the accuracies of other models. A nonrelativistic Schroedinger equation with two-body potentials is used for the scattering of a single particle by an energy-dependent local potential. The potential for the elastic channel is composed of matrix elements of a single scattering operator taken between the ground states of the projectile and the target; the coherent amplitude is considered as dominating the scattering in the forward direction. A multiple scattering series is analytically explored and formally summed by the solution of an equivalent Schroedinger equation. Cross sections of nuclear scattering are then determined for He-4 and C-12 nuclei at 3.6 GeV/nucleus and O-16 projectiles at 2.1 GeV/nucleus, and the optical model approximations are found to be consistently lower and more accurate than approximations made by use of Glauber's theory.

Wilson, J. W.↗

A Simple Physical Optics Algorithm Perfect for Parallel Computing Architecture

A reflector antenna computer program based upon a simple discreet approximation of the radiation integral has proven to be extremely easy to adapt to the parallel computing architecture of the modest number of large-gain computing elements such as are used in the Intel iPSC and Touchstone Delta parallel machines.

reflector antenna Intel iPSC Touchstone Delta↗

Direct Polishing of Full-Shell, High-Resolution X-Ray Optics

Future x-ray telescopes will likely require lightweight mirrors to attain the large collecting areas needed to accomplish the science objectives. Understanding and demonstrating processes now is critical to achieving sub-arcsecond performance in the future. Consequently, designs not only of the mirrors but of fixtures for supporting them during fabrication, metrology, handling, assembly, and testing must be adequately modeled and verified. To this end, MSFC is using finite-element modeling to study the effects of mounting on thin, full-shell grazing-incidence mirrors, during all processes leading to a flight.

X-Ray Optics↗

An in Situ Technique for Elemental Analysis of Lunar Surfaces

An in situ analytical technique that can remotely determine the elemental constituents of solids has been demonstrated. Laser-Induced Breakdown Spectroscopy (LIBS) is a form of atomic emission spectroscopy in which a powerful laser pulse is focused on a solid to generate a laser spark, or microplasma. Material in the plasma is vaporized, and the resulting atoms are excited to emit light. The light is spectrally resolved to identify the emitting species. LIBS is a simple technique that can be automated for inclusion aboard a remotely operated vehicle. Since only optical access to a sample is required, areas inaccessible to a rover can be analyzed remotely. A single laser spark both vaporizes and excites the sample so that near real-time analysis (a few minutes) is possible. This technique provides simultaneous multielement detection and has good sensitivity for many elements. LIBS also eliminates the need for sample retrieval and preparation preventing possible sample contamination. These qualities make the LIBS technique uniquely suited for use in the lunar environment.

Kane, K. Y.↗

Solar wind radiation damage effects in lunar material

The research on solar wind radiation damage and other effects in lunar samples which was conducted to understand the optical properties of lunar materials is reported. Papers presented include: solar radiation effects in lunar samples, albedo of the moon, radiation effects in lunar crystalline rocks, valence states of 3rd transition elements in Apollo 11 and 12 rocks, and trace ferric iron in lunar and meteoritic titanaugites.

Hapke, B.↗

A solid state multispectral imager.

Photodiode arrays used as image sensors in satellite remote imaging systems offer the advantages of geometric accuracy, precise registration of scene elements, enhanced operational reliability, and wide spectral response. Principles of photodiode-array operation are reviewed, and the latest developments in self-scanned array chip technology are described along with optical system requirements for multispectral coverage. Results of development efforts with a spaceborne solid-state multispectral camera based on linear sensing array technology are outlined to demonstrate the capabilities of this approach to multispectral sensing.

Green, A.↗