Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Onboard processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,483 records · Page 83

Spectroscopic diagnostics of high-temperature plasma in stellar coronae using Fe XXIV-XXIV K-shell lines with XRISM

The RS CVn type binary star GT Muscae was observed during its quiescence using the Resolve X-ray microcalorimeter spectrometer onboard XRISM. The main and satellite lines of the Fe XXIV-XXIV K-shell transitions were resolved for the first time from stellar sources. We conducted line ratio analysis to investigate any deviations from collisional ionization equilibrium and Maxwell electron energy distribution with a single temperature. By using five combinations of direct excitation lines and dielectronic recombination satellite lines in three line complexes (Fe He$\alpha$, Ly$\alpha$, and He$\beta$), we found that the plasma is well characterized by two-temperature thermal plasmas with temperatures of 1.7 and 4.3 keV, which is consistent with thermal broadening of Fe xxv, and the broad-band fitting results in the 1.7–10 keV band. Other forms of deviation from a single-temperature plasma, such as different ionization and electron temperatures or the $\kappa$ distribution for the electron energy distributions, are not favored, which is reasonable for stellar coronae at quiescence. This study demonstrates the utility of the Fe K-shell line ratio diagnostics to probe plasma conditions using X-ray microcalorimeters.

X-rays: stars↗

Metabolomic and Genomic Markers of Atherosclerosis as Related to Oxidative Stress, Inflammation, and Vascular Function in Twin Astronauts

Background: Future human space travel will consist primarily of long-duration missions onboard the International Space Station (ISS) or exploration-class missions to Mars, its moons, or nearby asteroids. Astronauts participating in long-duration missions may be at an increased risk of oxidative stress and inflammatory damage due to radiation, psychological stress, altered physical activity, nutritional insufficiency, and hyperoxia during extravehicular activity. By studying one identical twin during his 1-year ISS mission and one ground-based twin, this work extends a current NASA-funded investigation to determine whether these spaceflight factors contribute to an accelerated progression of atherosclerosis. This study of twins affords a unique opportunity to examine the spaceflight-related atherosclerosis risk independent of the confounding factors associated with different genotypes. Purpose: The purpose of this investigation is to determine whether biomarkers of oxidative and inflammatory stress are elevated during and after long-duration spaceflight and determine if a relation exists between levels of these biomarkers and structural and functional indices of atherosclerotic risk measured in the carotid and brachial arteries. These physiological and biochemical data will be extended by using an exploratory approach to investigate the relationship between intermediate phenotypes and risk factors for atherosclerosis and the metabolomic signature from plasma and urine samples. Since metabolites are often the indirect products of gene expression, we will simultaneously assess gene expression and DNA methylation in leukocytes. Hypothesis: We predict that the space-flown twin will experience elevated biomarkers of oxidative stress and inflammatory damage, altered arterial structure and function, accelerated telomere shortening, dysregulation of genes associated with oxidative stress and inflammation, and a metabolic profile shift that is associated with elevated atherosclerosis risk factors. Conversely, these will not be observed in the ground-based twin. Methods: We will measure blood and urine biomarkers of oxidative stress and inflammation as well as arterial structure and function (carotid intima-medial thickness and brachial artery flow-mediated dilation) in one twin astronaut before, during, and after long-duration spaceflight and in his twin serving as a ground-based control. Furthermore, we will measure metabolomics (targeted and untargeted approaches) and genomic markers (DNA methylation, mRNA gene expression, telomere length) to elucidate the molecular mechanisms involved. A panel of biomarkers of oxidative and inflammatory stress will be measured in venous blood samples and 24-hour (in-flight) and 48-hour (pre- and post-flight) urine pools twice before flight, early (flight days 15 and 60) and late (2 weeks before landing) during the mission, and early in the post-flight recovery phase (approximately 3-5 days after landing). Arterial structure, assessed from measures of intima-media thickness, will be measured at the same times. Arterial function will be assessed using brachial flow-mediated dilation, a well-validated measure used to assess endothelium-dependent vasodilation and a sensitive predictor of atherosclerotic risk, only before and after spaceflight. Discussion: Pre- and in-flight data collection is in progress for the space-flown twin, and similar data have been obtained from the ground-based twin. Blood and urine samples will be batch processed when received from ISS after the conclusion of the 1-year mission. Results from these individual subjects will be compared to the larger complement of subjects participating in the companion study currently ongoing in ISS astronauts.

Lee, Stuart M. C.↗

Size-resolved ice nucleating particle (INP) concentrations from the MOSAiC campaign

Sample collection: Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the U.S. DOE ARM AMF2 onboard the R/V Polarstern P-deck during MOSAiC from 23 Oct 2019 to 01 Oct 2020. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D had particle size cuts at 2.96, 1.21, 0.34, and 0.15 &micro;m in particle diameter, respectively. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. During MOSAiC, the pump typically pulled 20 &ndash; 35 lpm (average of 32 lpm) at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 28,800 &ndash; 50,400 total L of air (average of 46,080 L total L of air) per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Sample preparation for analysis: Following collection and transport from MOSAiC to the Kreidenweis/DeMott laboratory, care of PI Creamean, in Fort Collins, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile 15-mL centrifuge tubes and stored in a standard commercial freezer until analysis (approximately 4 &ndash; 12 months after collection). Sample analysis: Drop freezing assays (DFAs) were conducted on one daily sample set every 3 &ndash; 4 days of the study for all four stages using the Colorado State University (CSU) cold plate (CP). Sample set days were chosen to cover the entire year of MOSAiC and avoiding days where the AOS purge system was activated. Immediately after removal from the freezer, 2 mL of 0.1-&micro;m filtered deionized water was added with a single-use sterile syringe directly to the tubes, then mixed using a vortex mixer for at least 30 minutes at 500 rpm to resuspend particles from the PFA into the deionized water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 &micro;L each), though careful inspection. The plate was cooled at approximately 3 &ndash; 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen was and INP concentrations were calculated per L of air using the equation from Vali (1971): [INPs] = &minus;(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Data usage guidance: There are three files included with this dataset: (1) dumcp_inp_concentrations.csv which includes cumulative INP concentrations binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C for all samples and size ranges (i.e., DRUM stages) processed via DFA using the CSU CP; (2) dumcp_inp_standard_deviation.csv which includes the standard deviations for all samples and temperatures in dumcp_inp_concentrations.csv; and (3) dumcp_blank_concentrations_standard_deviation.csv which includes the INP concentrations and standard deviations for the deionized water and PFA blanks binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C. The first column in each file represents the freezing temperature in &deg;C binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C (first cell in this column = header = &ldquo;temp&rdquo;). The second column in each file represents the standard deviation of each temperature bin in &deg;C (first cell in this column = header = &ldquo;temperr&rdquo;). For file (1) dumcp_inp_concentrations.csv, the remaining columns indicate the INP concentrations per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (2) dumcp_inp_standard_deviation.csv, the remaining columns indicate the INP concentration standard deviation per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (3) dumcp_blank_concentrations_standard_deviation.csv, the remaining columns indicate the INP concentrations and standard deviations for the deionized water blank (&ldquo;di_0.1&rdquo; and &ldquo;di_0.1sd&rdquo; for the concentrations and standard deviations, respectively) and PFA blank (&ldquo;pfa&rdquo; and &ldquo;pfasd&rdquo; for the concentrations and standard deviations, respectively). Please see Creamean et al. (2019a; 2018a; 2018b; 2019b) for additional details on DRUM sample collection and offline processing. For questions or help with data interpretation, contact Dr. Jessie Creamean (jessie.creamean@colostate.edu). References: Creamean, J. M., Mignani, C., Bukowiecki, N., and Conen, F.: Using spectra characteristics to identify ice nucleating particle populations during winter storms in the Alps, Atmos. Chem. Phys., 19, 8123&ndash;8140, 2019a. Creamean, J. M., Kirpes, R. M., Pratt, K. A., Spada, N. S., Maahn, M., de Boer, G., Schnell, R. C., and China, S.: Marine and terrestrial influences on ice nucleating particles during continuous springtime measurements in an Arctic oilfield location, Atmospheric Chemistry and Physics, 18, 18023-18042, 10.5194/acp-18-18023-2018, 2018a. Creamean, J. M., Primm, K. M., Tolbert, M. A., Hall, E. G., Wendell, J., Jordan, A., Sheridan, P. J., Smith, J., and Schnell, R. C.: HOVERCAT: A novel aerial system for evaluation of aerosol-cloud interactions, Atmospheric Measurement Techniques, 11, 3969-3985, 10.5194/amt-11-3969-2018, 2018b. Creamean, J. M., Cross, J. N., Pickart, R., McRaven, L., Lin, P., Pacini, A., Hanlon, R., Schmale, D. G., Ceniceros, J., Aydell, T., Colombi, N., Bolger, E., and DeMott, P. J.: Ice nucleating particles carried from below a phytoplankton bloom to the Arctic atmosphere, Geophys. Res. Lett., 46, 8572-8581, https://doi.org/10.1029/2019GL083039, 2019b. Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2, 1971.

4-stage DRUM aerosol collector (DA400),Ice nuclei,↗

Robonaut 2 - IVA Experiments On-Board ISS and Development Towards EVA Capability

Robonaut 2 (R2) has completed its fixed base activities on-board the ISS and is scheduled to receive its climbing legs in early 2014. In its continuing line of firsts, the R2 torso finished up its on-orbit activities on its stanchion with the manipulation of space blanket materials and performed multiple tasks under teleoperation control by IVA astronauts. The successful completion of these two IVA experiments is a key step in Robonaut's progression towards an EVA capability. Integration with the legs and climbing inside the ISS will provide another important part of the experience that R2 will need prior to performing tasks on the outside of ISS. In support of these on-orbit activities, R2 has been traversing across handrails in simulated zero-g environments and working with EVA tools and equipment on the ground to determine manipulation strategies for an EVA Robonaut. R2 made significant advances in robotic manipulation of deformable materials in space while working with its softgoods task panel. This panel features quarter turn latches that secure a space blanket to the task panel structure. The space blanket covers two cloth cubes that are attached with Velcro to the structure. R2 was able to open and close the latches, pull back the blanket, and remove the cube underneath. R2 simulated cleaning up an EVA worksite as well, by replacing the cube and reattaching the blanket. In order to interact with the softgoods panel, R2 has both autonomously and with a human in the loop identified and localized these deformable objects. Using stereo color cameras, R2 identified characteristic elements on the softgoods panel then extracted the location and orientation of the object in its field of view using stereo disparity and kinematic transforms. R2 used both vision processing and supervisory control to successfully accomplish this important task. Teleoperation is a key capability for Robonaut's effectiveness as an EVA system. To build proficiency, crewmembers have attempted increasingly difficult tasks using R2 inside the Station. After donning motion capture equipment and a virtual reality visor, Expedition 34/35 flight engineer Tom Marshburn began operations with simple hand movements. Having gained confidence, Marshburn guided R2's arms in a leader-follower exercise with crewmate Chris Cassidy. He was also able to use the hand to grab a tumbling roll of tape, a task only demonstrable in microgravity. Later efforts saw Cassidy handle softgoods through shared control with ground operators, mimicking an activity previously achieved using only autonomy. Robotic climbing through the ISS on handrails requires both precision motion and compliant grasps in order to both position grippers on handrails/seat track and prevent large internal forces. R2 climbs using actively controlled compliance and torque limiting to meet both the precision and softness requirements. During a step, the attached leg is controlled to be strong and stiff in order to maintain precision trajectory tracking. The swing leg is controlled to be stiff but weak to minimize unintentional impact forces while maintaining precision. During a simulated dual limb grasp (as shown in Figure 1), the R2 controller maintains one limb rigid and one limb soft to prevent large internal forces from building up. R2's grippers also use a form of force control to limit grip force while not fully closed on either a handrail or seat track thus limiting unintentional forces on cables/objects that may be present in R2's translational path. The on-board torso R2 safety system relies on a single end-effector velocity limit to prevent potential impact forces from exceeding Station maximum load requirements. R2's mobile configuration required modifications to the velocity limiting safety function due to its large, dynamic inertia. R2's legs maneuver the robot's mass creating configuration dependent, joint-relative inertias. A single all-encompassing velocity limit to cover worst case inertia is prohibitively low. The upgraded R2 control and safety systems solve this problem using momentum limiting, momentum control, and kinetic energy minimization. Momentum and kinetic energy take the robot mass into account relieving low velocity restrictions on low inertia end-effectors while ensuring that the overall mass of R2 is limited from hazardous velocities. The momentum of R2's five safety nodes (each of the four end-effectors and the body) is monitored and compared to a single momentum limit. If any of the five nodes exceeds the safety limit, the motor power is removed and the robot comes to a stop. Momentum control/limiting also provides a simple, reliable method to integrate hand held tools into the safety system by providing the tool mass to the control system thus automatically reducing the allowable velocity of the end-effector with the tool. Work on the ground continues to build the skill set for an EVA Robonaut. Recent experiments (Figure 2) demonstrate how a teleoperator can use R2 to manipulate a tether hook, an important safety precaution on spacewalks. Another task displayed Robonaut's ability to pull back a protective jacket over a hose and search for damage, as well as inspect a quick-disconnect fitting for debris. Demonstrations such as these are indicative of EVA work done on ISS, specifically seen during a series of spacewalks over 2012 and 2013 where astronauts searched for an ammonia leak in one of the external cooling loops. Through experiments both on ISS and on the ground, R2 is evolving and providing the information needed to plan out the upgrades that will make an EVA Robonaut an effective tool. With the addition of legs, R2 will start climbing inside the space station and supply invaluable information on how the climbing strategies and task stabilization techniques must be refined. Ground R2 systems will continue to work with additional EVA tools and equipment in preparation for onboard IVA testing and future EVA applications.

Diftler, Myron↗

Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images

Purpose: To investigate whether the three-dimensional cone-beam CT (CBCT) is clinically equivalent to the four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) reconstructed images for internal target volume (ITV) localization in image-guided lung stereotactic radiotherapy.Methods: A ball-shaped polystyrene phantom with built-in cube, sphere, and cone of known volumes was attached to a motor-driven platform, which simulates a sinusoidal movement with changeable motion amplitude and frequency. Target motion was simulated in the patient in a superior-inferior (S-I) direction with three motion periods and 2 cm peak-to-peak amplitudes. The Varian onboard Exact-Arms kV CBCT system and the GE LightSpeed four-slice CT integrated with the respiratory-position-management 4DCT scanner were used to scan the moving phantom. MIP images were generated from the 4DCT images. The clinical equivalence of the two sets of images was evaluated by comparing the extreme locations of the moving objects along the motion direction, the centroid position of the ITV, and the ITV volumes that were contoured automatically by Velocity or calculated with an imaging gradient method. The authors compared the ITV volumes determined by the above methods with those theoretically predicted by taking into account the physical object dimensions and the motion amplitudes. The extreme locations were determined by the gradient method along the S-I axis through the center of the object. The centroid positions were determined by autocenter functions. The effect of motion period on the volume sizes was also studied.Results: It was found that the extreme locations of the objects determined from the two image modalities agreed with each other satisfactorily. They were not affected by the motion period. The average difference between the two modalities in the extreme locations was 0.68% for the cube, 1.35% for the sphere, and 0.5% for the cone, respectively. The maximum difference in the centroid position of the cylinder, sphere, and cone was less than 1.4 mm between the two modalities for all motion periods studied. For the ITV volume evaluation, the authors found that both MIP-based and CBCT-based ITVs increased with increases of motion period. Furthermore, the MIP-based ITV volumes were generally larger than those determined from the CBCT images, with the difference in autocontoured volumes being 2.57%, 1.66%, and 1.82% for the sphere, cylinder, and cone, respectively, while these differences increased to 9.57%, 3.52%, 8.71% for the above objects when the gradient method was used. The authors found that the autocontour method was accurate enough to predict the actual ITV values with the absolute differences less than 2.4% comparing to the theoretically predicted values.Conclusions: The extreme location and the centroid position of the objects agree with each other between the two image modalities when the breathing motion is sinusoidal. Although the ITV volumes delineated from both image modalities changed with the motion period, the differences in ITV between the two modalities were minimal when an optimized window level was used. The authors’ results suggest that CBCT and MIP images are equivalent in determining an ITV's position in the conditions studied. The CBCT is adequate in providing imaging-guidance for lung cancer treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$\alpha$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of ${\sim }$0.2 eV, equivalent to a line-of-sight velocity of ${\sim }$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$\alpha$ line shifts redward by ${\sim }$4 eV as q increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$\beta$ line at 7.06 keV shifts blueward by ${\sim }$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$\alpha$ and K$\beta$ line provides a robust estimate of q by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$\alpha$, K$\beta$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$\alpha$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

Astronomy and AstroPhysics↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗