Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Genomic selection in algae with biphasic lifecycles: A Saccharina latissima (sugar kelp) case study

Introduction Sugar kelp ( Saccharina latissima ) has a biphasic life cycle, allowing selection on both thediploid sporophytes (SPs) and haploid gametophytes (GPs). Methods We trained a genomic selection (GS) model from farm-tested SP phenotypic data and used a mixed-ploidy additive relationship matrix to predict GP breeding values. Topranked GPs were used to make crosses for further farm evaluation. The relationship matrix included 866 individuals: a) founder SPs sampled from the wild; b) progeny GPs from founders; c) Farm-tested SPs crossed from b); and d) progeny GPs from farm-tested SPs. The complete pedigree-based relationship matrix was estimated for all individuals. A subset of founder SPs ( n = 58) and GPs ( n = 276) were genotyped with Diversity Array Technology and whole genome sequencing, respectively. We evaluated GS prediction accuracy via cross validation for SPs tested on farm in 2019 and 2020 using a basic GBLUP model. We also estimated the general combining ability (GCA) and specific combining ability (SCA) variances of parental GPs. A total of 11 yield-related and morphology traits were evaluated. Results The cross validation accuracies for dry weight per meter ( r ranged from 0.16 to 0.35) and wet weight per meter ( r ranged 0.19 to 0.35) were comparable to GS accuracy for yield traits in terrestrial crops. For morphology traits, cross validation accuracy exceeded 0.18 in all scenarios except for blade thickness in the second year. Accuracy in a third validation year (2021) was 0.31 for dry weight per meter over a confirmation set of 87 individuals. Discussion Our findings indicate that progress can be made in sugar kelp breeding by using genomic selection.

59 BASIC BIOLOGICAL SCIENCES↗

EPCAPE-PT-LANL Measurements: PM Modulair 1

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Quant-AQ MODULAIR. Mounted external to the instrument container, near the GCVI inlet. The MODULAIR™ air quality monitor uses the same patent-pending PM sensor found in the MODULAIR™-PM and adds four gas-phase measurements (CO, NO, NO2, and O3) to provide an all-in-one solution. Files data_10sec_Quant_Gas.csv, data_10min_Quant_Gas.csv Header: - CO[ppb]: Concentration of carbon monoxide (CO) measured at the time of sampling, expressed in parts per billion (ppb) - NO[ppb]: Concentration of nitric oxide (NO) measured at the time of sampling, expressed in parts per billion (ppb). - O3[ppb]: Concentration of ozone (O3) measured at the time of sampling, expressed in parts per billion (ppb). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. Files data_10sec_Quant_PM.csv, data_10min_Quant_PM.csv Header: - PM1[ug/m3]: Concentration of particulate matter with a diameter of 1 micron or less, measured in micrograms per cubic meter (µg/m³). - PM2-5[ug/m3]: Concentration of particulate matter with a diameter of 2.5 microns or less measured in micrograms per cubic meter (µg/m³). - PM10[ug/m3]: Concentration of particulate matter with a diameter of 10 microns or less, measured in micrograms per cubic meter (µg/m³). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage.

54 ENVIRONMENTAL SCIENCES↗

Integrated GW Farm ABM

This Data Repository includes data used for the integrated groundwater- farm ABM model, raw model output from scenario ensemble, and processed outputs that isolate the groundwater storage depletion outcomes for the 35,000 farm cells. Model Inputs: Farm ABM Inputs: This folder contains the input data used by the integrated groundwater - farm ABM modelling script (Python file) used for the high performance computing (HPC) experiments. The sub-folder "data inputs" contains all of the farm attribute data, while the three files in the folder have the hydrogeological data lookup table (NLDAS Cost Curve Attributes.csv), a lookup table (Theis well function table.csv) for the groundwater cost curve function, and the farm indexes and corresponding NLDAS ids for all of the cells run in this experiment (nldas farms subset final.csv). NLDAS Cost curve hydrogeological data: Hydrogeological data aggregated to 1/8 degree resolution and aligned with the NLDAS grid. Parameters include: water depth below ground surface [meters], subsurface porosity [unitless], aquifer depth from ground surface to aquifer bottom [meters], annual average recharge (USGS: mm, Doll: meters), and three different hydraulic conductivity (K) values (meters/day). The three K values represent the mean value from Gleeson et al. (2018), one standard deviation above the mean from Gleeson et al. (2018), and the de Graaf et al. 2020 modifications to certain lithologies. Additional information about these datasets and their processing are documented in the supplement to Yoon et al. 2025 (in review). Output: Raw outputs: This folder contains a .zip file that has model outputs for the entire scenario ensemble. There is one csv for each farm id, using the format "farm farmid cases.csv". The relationship between the farm id and NLDAS id is defined by the "nldas farms subset final.csv" located in the Farm ABM Inputs folder. Each csv has 625 rows, corresponding to 625 combinations of different scenario parameter values. Each row (scenario) represents the outcome of a 100 year simulation. Columns define scenario settings and summary statistics for each scenario. The first four columns define the scenario settings: "hydro ratio," "econ ratio," "K scenario," and "gamma scenario." The hydro and econ ratios are values passed to the modeling script that influence multipliers for other model parameters, as documented in the supplement to Yoon et al. 2025 (in review). The gamma multiplier is a coefficient multiplier applied to the baseline gamma values (values below 1 represent lower unobserved costs compared to baseline, values above 1 represent higher costs). The K scenario names represent K values of: "low": 0.5 m/d, "int 1": 2.5 m/d, "int 2": 10 m/d, "high": 50 m/d, and "gleeson": mean Gleeson K value. "Perc vol depleted" is the fraction of groundwater depleted at the end of the 100 simulation. Processed Output: Derived depletion outcomes from raw outputs: All of the individual csv files from the Raw outputs were aggregated into a single file that has the scenario settings and fraction depletion "Perc vol depleted" for every farm cell, for every scenario. The other two files define relationships between the farm id, NLDAS id, and local and major aquifer units, used for aquifer-level depletion analysis.

Agent based modeling↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

A comparison and evaluation of satellite derived positions of tracking stations

A comparison is presented of sets of satellite tracking station coordinate values published in the past few years by a number of investigators, i.e. Goddard Space Flight Center, Smithsonian Astrophysical Observatory, Ohio State University, The Naval Weapons Laboratory, Air Force Cambridge Research Laboratories, and Wallops Island. The comparisons have been made in terms of latitude, longitude and height. The results of the various solutions have been compared directly and also with external standards such as local survey data and gravimetrically derived geoid heights. After taking into account systematic rotations, latitude and longitude agreement on a global basis is generally 15 meters or better, on the North American Datum agreement is generally better than 10 meters. Allowing for scale differences (of the order of 2 ppm) radial agreement is generally of the order of 10 meters.

Vincent, S. F.↗

Error studies for ground tracking of synchronous satellites

The results of various sets of tracking error analysis studies of the ability of ground stations to determine the position and velocity of synchronous satellites are summarized. The effects of varying: (1) the ground station configuration from 1 to 6 tracking stations in differing locations; (2) the ground station measurement type such as S-Band, C-Band, VHF, and lasers and (3) the uncertainties in ground station location are investigated. The linear error analysis computer program used includes the effects of ground tracking station location uncertainties, measurement noise and biases, and station timing bias. Results show that two ground trackers are needed if at least 2000 meters position accuracy is desired, with a favorable two-station solution giving less than 500 meters position accuracy. Under favorable circumstances, a multi-station laser solution gives a synchronous satellite position accuracy of less than 100 meters. The various cases illustrate features of synchronous satellite tracking from ground stations.

Cooley, J. L.↗

Light-detection electronics for a Raman lidar

A light-detection system for an optical radar, or lidar, unit to be used for remote temperature and composition measurements was designed, built, and bench tested. This detection system processes three return signal wavelengths: two Raman wavelengths, and the Rayleigh-Mie wavelength at 694.3 nanometers. Means of coping with photomultiplier tube instabilities and limitations are discussed. Circuits for gain control, ranging, and digitizing are included. The phototube gains can be switched fully on in 80 meters (450 nsec) or off in 30 meters (200 nsec) of range. The range circuit processes signals from 0.1 to 2 kilometers, with an estimated range resolution of less than 5 meters.

Leser, R. J.↗

A nuclear powered air cushion freighter for the 1980's.

A design for a transoceanic, dry cargo-carrying freighter is suggested; its use and operation in port are discussed. With a gross weight of 4500 metric tons (5000 tons), more than 50 percent of which is cargo, it will cruise at 50 meters per second (100 knots) in waves 2.4 meters (8 ft) high. Its peripheral jet-flexible skirt air cushion concept and air thrustors will let the freighter go over waves 8 meters high at reduced velocity. Power comes from a 1280 megawatt, helium-cooled thermal reactor. It could dock at any major port in the world, but because it needs no surface contact, it could also travel inland to land-locked ports. A modular terminal design and methods of cargo transfer are suggested. The concept of cargo containerization influences both the freighter and terminal design.

Anderson, J. L.↗

Comparative cut-bar thermal conductivity apparatus.

Construction details, error analysis, and typical data for a rapid comparative device for thermal conductivity measurements are presented. The apparatus consists of a comparative cut-bar arrangement contained in a bell-jar. The cylinder shaped specimen is placed between two ARMCO-iron meter bars of the same diameter. The upper bar is equipped with a heater, while the lower one is terminated in a heat sink. The temperature gradient along the bars is measured with a series of copper/constantan microthermocouples, spot welded to them. The assembly is held together by loading the bars to a desired pressure, via a pneumatic cylinder. Contact resistance at the boundaries between the specimen and the meter bars is minimized by using a Hg/In/Ga alloy film at the interface and sufficient loading force. The gradients determined for the meter bars then may be extrapolated to the boundaries yielding the temperature drop along the specimen. Using two different length specimens, the magnitude of the temperature drop across the interface can be computed, or the true gradient along the specimen can be obtained from the difference in overall temperature drops and lengths.

Gaal, P. S.↗

Research study to determine critical optical/mechanical properties of materials considered for selection as substrates for the primary mirror on a large telescope

An investigation was conducted to evaluate the stability of a specific low expansion glass-ceramic material relative to its use as a large, lightweight mirror substrate for diffraction-limited spaceborne optical applications. These evaluations were made on a segment (0.44 meter diameter by 0.31 meter thick) of a 2 to 3 meter diameter mirror blank. The dimensional stability of this mirror was measured interferometrically before and after lightweighting, as a function of rough machining, etching, thermal environment, and support configuration. A special computer analysis program was used to plot the coefficients corresponding to aberrations with sixfold symmetry (caused by the mirror's self-weight deflection on a three point support). The objective was to enhance the test sensitivity. Results indicate that any such effects due to self-weight deflection are of the order of 0.015 lambda rms. The rms and peak-to-peak figure changes associated with each processing operation are summarized.

Slomba, A. F.↗

Overall evaluation of ERTS-1 imagery for cartographic application

The author has identified the following significant results. Significant scientific conclusions are: (1) Bulk RBV's have internal positional accuracy in the order of 70 meters at ground scale while MSS internal accuracy is in the order of 200 to 300 meters. Both have precision processed images with accuracy within 70 meters. (2) Image quality exhibited by detectability and acutance is better than expected and perhaps twice as good as would be achieved by photographic film of the same resolution. (3) Photometric anomalies (shading) have limited RBV multispectral application, but it is believed that these anomalies can be further reduced. (4) The MSS has exceptionally high photometric fidelity but the matching of scenes taken under different conditions of illumination has not been resolved. (5) MSS bands 6 and 7 have enormous potential for surface water mapping including the correlation of shorelines at various water stages. (6) MSS band 7 demonstrates an actual cloud penetration capability beyond what was expected. It also has delineated cultural features better than the other MSS bands under certain conditions.

Colvocoresses, A. P.↗

High-pressure combustor exhaust emissions with improved air-atomizing and conventional pressure-atomizing fuel nozzles

A high-pressure combustor segment 0.456 meter (18 in.) long with a maximum cross section of 0.153 by 0.305 meter (6 by 12 in.) was tested with specially designed air-atomizing and conventional pressure-atomizing fuel nozzles at inlet-air temperatures of 340 to 755 k (610 deg to 1360 R), reference velocities of 12.4 to 26.1 meters per second (41 to 86 ft/sec), and fuel-air ratios of 0.008 to 0.020. Increasing inlet-air pressure from 4 to 20 atmospheres generally increased smoke number and nitric oxide, but decreased carbon monoxide and unburned hydrocarbon concentrations with air-atomizing and pressure-atomizing nozzles. Emission indexes for carbon monoxide and unburned hydrocarbons were lower at 4, 10, and 20 atmospheres, and nitric oxide emission indexes were lower at 10 and 20 atmospheres with air-atomizing than with pressure-atomizing nozzles.

Ingebo, R. D.↗

Effect of parallactic refraction correction on station height determination

The effect of omitting the parallactic refraction correction for satellite optical observations in the determination of station coordinates is analyzed for a large satellite data distribution. A significant error effect is seen in station heights. A geodetic satellite data distribution of 23 close earth satellites, containing 30,000 optical observations obtained by 13 principal Baker-Nunn camera sites, is employed. This distribution was used in a preliminary Goddard Earth Model (GEM 1) for the determination of the gravity field of the earth and geocentric tracking station locations. The parallactic refraction correction is modeled as an error on the above satellite data and a least squares adjustment for station locations is obtained for each of the 13 Baker-Nunn sites. Results show an average station height shift of +8 meters with a dispersion of plus or minus 0.7 meters for individual sites. Station latitude and longitude shifts amounted to less than a meter. Similar results are obtained from a theoretical method employing a probability distribution for the satellite optical observations.

Lerch, F. J.↗

Analysis of test data film generated by the lunar sounder (S-209)

The analysis of test films pertaining to the readiness of the Apollo 17 radar equipment is discussed. Emphasis is placed on the evaluation of the lunar sounder equipment. The lunar sounder experiment was to examine the lunar surface at three different radar frequencies of 2 meters, 60 meters, and 20 meters. Test films were made on the lunar sounder system to describe the purpose of the test, to describe the experiments used for analysis, and to provide conclusions reached after analysis.

Massey, N.↗

Titan/Centaur: NASA's newest launch vehicle

Titan/Centaur is NASA's last new expendable launch vehicle prior to the advent of the space shuttle. Titan/Centaur is an adaptation of the Air Force Titan 3 booster with an improved version of the Centaur stage and a new 4.2 meters payload fairing. Titan/Centaur is initially being used for high performance escape missions (Helios Solar Probe - 340 kilograms' Viking Mars Orbiter and Lander - 3,629 kilograms, and Mariner Jupiter/Saturn Fly-Bys at 771 kilograms, but is also particularly suited for larger spacecraft in synchronous orbits (transfer - 7,031 kilograms and equatorial, with three Centaur burns - 3,175 kilograms). The program which began in 1965 with internal NASA feasibility studies will culminate in a proof flight launch in early 1974. With the new payload fairing, which also encloses Centaur, payloads of nearly 8.5 meters long and 3.8 meters in diameter can be accommodated.

Stofan, A. J.↗

Life tests of small turbine-type flowmeters in liquid hydrogen

A total of 14 turbine-type flowmeters of 2.5- and 4-cm nominal size were operated for 100 or more hours at an average fluid speed in the unobstructed, upstream pipe of 20 m/s for the smaller meters and 9 m/s for the larger meters. Calibration shifts over a 6.1 range of calibration flow rates varied from 0.5 percent to 1 percent after 50 hr of operation. It is concluded that use of ball bearings with glass-filled Teflon retainers is most likely to produce minimal calibration shift with protracted use. Bearing replacement after 50 to 100 hr is recommended, depending on accuracy requirements, for meters used at the fluid speeds of the tests.

Hobart, H. F.↗

Principal sources and dispersal patterns of suspended particulate matter in nearshore surface waters of the northeast Pacific Ocean and the Hawaiian Islands

The author has identified the following significant results. ERTS-1 green and red band imagery supplemented by U-2 photographs provides synoptic views of turbid, nearshore, near-surface bodies of water which adds to the body of knowledge about the coastal ocean necessary for a thorough understanding of the dynamic environment. Tubidity and suspended sediment measurements made in the Gulf of the Farallones correlate well with water tonal patterns visible on satellite imagery. Three successively seaward zones of turbid water could be delineated. Secchi disc visibility tests were the most definitive, ranging from or = 2 meters in the main plume, to almost 3 meters in the second zone of turbid water, to 4 meters in the furthest seaward zone of turbid water measured. These variations in water clarity were reinforced by suspended sediment concentrations which ranged from 26-28 mg/1, to 20-24 mg/1, to 11-15 mg/1, respectively, in each of the three masses of water. Transmissiometer readings were basically in agreement with the suspended sediment and Secchi disc values measured. Satellite imagery and U-2 photographs of the California coastal zone taken early in April 1973 show numerous plumes of suspended sediment being deflected southward. This indicates a southward flow of the nearshore, near-surface waters, a reversal from that noted in January 1973.

Carlson, P. R.↗