Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Temperature-induced anomalous magnetotransport in the Weyl semimetal Mn 3 Ge

The magnetic Weyl semimetallic state can lead to intriguing magnetotransport, such as chiral anomaly and the layered quantum Hall effect. Mn3X (X = Sn, Ge) is a noncollinear antiferromagnetic semimetal where a Weyl semimetallic state is stabilized by time-reversal symmetry breaking. Compared to the well-studied Mn3Sn, the Weyl fermion-induced magnetotransport in Mn3Ge has been merely studied. Here, we report an in-depth study on the magnetotransport in a microfabricated Mn3Ge single crystal from room temperature to 10 K. We reveal an anomalous anisotropic magnetoresistance with fourfold symmetry and a positive high-field longitudinal magnetoresistance below the critical temperature (160–170 K). The possible origin is the temperature-induced tilting of the Weyl nodes. Our study helps to understand the magnetotransport properties in the Weyl fermion system.

36 MATERIALS SCIENCE↗

Investigating Nanoscale Electron Transfer Processes at the Cell-Mineral Interface in Cobalt-Doped Ferrihydrite Using Geobacter sulfurreducens: A Multi-Technique Approach

Cobalt is an essential element for life and plays a crucial role in supporting the drive to clean energy, due to its importance in rechargeable batteries. Co is often associated with Fe in the environment, but the fate of Co in Fe-rich biogeochemically-active environments is poorly understood. To address this, synchrotron-based scanning X-ray microscopy (SXM) was used investigate the behaviour of cobalt at the nanoscale in Co-Fe(III)-oxyhydroxides undergoing microbial reduction. SXM can assess spatial changes in metal speciation and organic compounds helping to elucidate the electron transfer processes occurring at the cell-mineral interface and inform on the fate of cobalt in redox horizons. G. sulfurreducens was used to reduce synthetic Co-ferrihydrite as an analogue of natural cobalt-iron-oxides. Magnetite [Fe(II)/Fe(III) 3 O 4 ] production was confirmed by powder X-ray diffraction (XRD), SXM and X-ray magnetic circular dichroism (XMCD) data, where best fits of the latter suggested Co-bearing magnetite. Macro-scale XAS techniques suggested Co(III) reduction occurred and complementary SXM at the nanoscale, coupled with imaging, found localised biogenic Co(III) reduction at the cell-mineral interface via direct contact with outer membrane cytochromes. No discernible localised changes in Fe speciation were detected in the reordered cobalt-iron-oxides that were formed and at the end point of the experiment only 11% Co and 1.5% Fe had been solubilised. The solid phase retention, alongside the highly localised and preferential cobalt bioreduction observed at the nanoscale is consistent with retention of Co in redox zones. This work improves our fundamental molecular-scale understanding of the fate of Co in complex environmental systems and supports the development of biogenic Co-doped magnetite for industrial applications from drug delivery systems to magnetic recording media.

58 GEOSCIENCES↗

Constant-voltage drive current-steering switch

Two-element voltage control system regulates a magnetic switch consisting of dual ferrite-core shift registers. The system has a magnetic, two-core-per-bit, voltage-controlled shift register.

Caplette, R. K.↗

Low-carrier density and fragile magnetism in a Kondo lattice system

Kondo-based semimetals and semiconductors are of extensive current interest as a viable platform for strongly correlated states in the dilute carrier limit. It is thus important to explore the routes to understand such systems. One established pathway is through the Kondo effect in metallic nonmagnetic analogs, in the so called half-filling case of one conduction electron and one 4f electron per site. Here, we demonstrate that Kondo-based semimetals develop out of conduction electrons with a low-carrier density in the presence of an even number of rare-earth sites. We do so by studying the Kondo material Yb 3 Ir 4 Ge 13 along with its closed-4f-shell counterpart, Lu 3 Ir 4 Ge 13 . Through magnetotransport, optical conductivity, and thermodynamic measurements, we establish that the correlated semimetallic state of Yb 3 Ir 4 Ge 13 below its Kondo temperature originates from the Kondo effect of a low-carrier conduction-electron background. In addition, it displays fragile magnetism at very low temperatures, which in turn, can be tuned to a Griffiths-phase-like regime through Lu-for-Yb substitution. These findings are connected with recent theoretical studies in simplified models. Furthermore, our results can pave the way to exploring strong correlation physics in a semimetallic environment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flowing plasma rearrangement in the presence of static perturbing fields

Charged particles interacting with electromagnetic waves have a portion of their energy tied up in wave-driven oscillations. When these waves are localized to the exhaust of linear magnetic confinement systems, this ponderomotive effect can be utilized to enhance particle confinement. The same effect can be derived for particles moving via an E×B drift into a region of a static perturbation to the electromagnetic fields which has a large wave vector component in the direction of the motion. In this work, we use a simplified slab model to self-consistently solve for the electromagnetic fields within the fluid flowing plasma of a static flute-like (k∥=0) perturbation and evaluate the resulting ponderomotive potential. We find that two types of perturbations can exist within the flowing plasma, which are an O wave and an X wave in the frame moving with the fluid. In the case of tenuous plasma, these perturbations are magnetostatic or electrostatic multipole-analog perpendicular to the guiding magnetic field in the lab frame, respectfully. For denser plasmas, the O wave-like perturbation is screened at the electron skin depth scale, and the X wave-like perturbation is a combination of a similar perpendicular electric perturbation and parallel magnetic perturbation. The ponderomotive potential generated in the X wave-like case is gyrofrequency-dependent and can be used as either potential barriers or potential wells, depending on the direction of the flow velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryogenic Permanent Magnet Undulators

For an in-vacuum undulator operated at small gaps the permanent magnet material needs to be highly resistant to possible electron beam exposure. At room temperature, one generally uses Sm{sub 2}Co{sub 17} or high coercivity NdFeB magnets at the expense of a limited field performance. In a cryogenic permanent magnet undulator (CPMU), at a temperature of around 150 K, any NdFeB grade reveals a coercivity large enough to be radiation resistant. In particular, very high remanence NdFeB material can be used to build undulators with enhanced field and X-ray brilliance at high photon energy provided that the pre-baking of the undulator above 100 deg. C can be eliminated. The ESRF has developed a full scale 2 m long CPMU with a period of 18 mm. This prototype has been in operation on the ID6 test beamline since January 2008. A significant effort was put into the characterization of NdFeB material at low temperature, the development of dedicated magnetic measurement systems and cooling methods. The measured heat budget with beam is found to be larger than expected without compromising the smooth operation of the device. Leading on from this first experience, new CPMUs are currently being considered for the upgrade of the ESRF.

43 PARTICLE ACCELERATORS↗

Plasma Surface Interactions: Predicting the Performance and Impact of Dynamic PFC Surfaces

The objective of this project is to develop, and integrate, high-performance simulation tools capable of predicting plasma-facing component (PFC) operating lifetime and the impact of the evolving surface morphology of tungsten-based PFCs on plasma contamination, including the dynamic recycling of fuel species and tritium retention, in future magnetic fusion devices. Establishing a fundamental physical understanding and developing predictive capabilities of plasma-surface interactions (PSI) requires simultaneously addressing complex and diverse physics occurring over a wide range of length (Angstroms to meters) and time (femtoseconds to years) scales, as well as integrating extensive physical processes across the plasma–surface interface. This requires development of not only detailed physics models and computational strategies at each scale, but also algorithms and methods to couple them effectively in a way that can be robustly validated. Deploying these tools requires the continued development and coupling of leadership-scale computational codes to describe the boundary plasma and the evolving PFC surface, as well as a host of simulations that bridge disparate scales to address complex physical and computational issues at the plasma–surface interface in multi-component materials systems for magnetic fusion energy development beyond ITER.

36 MATERIALS SCIENCE↗

THE ADIABATIC DEMAGNETIZATION REFRIGERATOR FOR THE MICRO-X SOUNDING ROCKET TELESCOPE

The Micro-X Imaging X-ray Spectrometer is a sounding rocket payload slated for launch in 2011. An array of Transition Edge Sensors, which is operated at a bath temperature of 50 mK, will be used to obtain a high resolution spectrum of the Puppis-A supernova remnant. An Adiabatic Demagnetization Refrigerator (ADR) with a 75 gram Ferric Ammonium Alum (FAA) salt pill in the bore of a 4 T superconducting magnet provides a stable heat sink for the detector array only a few seconds after burnout of the rocket motors. This requires a cold stage design with very short thermal time constants. A suspension made from Kevlar strings holds the 255 gram cold stage in place. It is capable of withstanding loads in excess of 200 g. Stable operation of the TES array in proximity to the ADR magnet is ensured by a three-stage magnetic shielding system which consists of a superconducting can, a high-permeability shield and a bucking coil. The development and testing of the Micro-X payload is well underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropic magnetocaloric effect and critical behavior in CrCl 3

We report anisotropic magnetocaloric effect and magnetic critical behavior in the van der Waals crystal CrCl 3 . The maximum magnetic entropy change $-ΔS^{max}_M ~ 14.6 J kg -1 K -1 and the relative cooling power RCP ~ 340.3 J kg -1 near T c with a magnetic field change of 5 T are much larger when compared to CrI 3 or CrBr 3 . The rescaled ΔS M (T, H) curves collapse onto a universal curve, confirming the second-order ferromagnetic transition. Finally, further critical behavior analysis around T c presents a set of critical exponents β = 0.28 (1) with T c = 19.4 (2) K, γ = 0.89 (1) with T c = 18.95 (8) K, and δ = 4.6 (1) at T c = 19 K , which are close to those of the theoretical tricritical mean-field model.

2-dimensional systems↗

Continuous Sub-Kelvin Cooling from an Adiabatic Demagnetization Refrigerator

We present the current state of development for a continuous magnetic refrigeration system capable of cooling a detector array or other payload to temperatures below 50 mK. This adiabatic demagnetization refrigerator contains four-stages that are cycling continuously yet present a constant ultra-low temperature heat sink at one physical location within the refrigerator. Two different configurations of essentially the same cooler will be presented where the difference is in the physical layout of the stages and the type of heat sink used for the refrigerator's heat rejection.

Magnetic Cooling↗

Spin-orbit exciton in a honeycomb lattice magnet CoTiO 3 : Revealing a link between magnetism in d - and f -electron systems

We carried out inelastic neutron scattering to study the spin-orbital (SO) exciton in a single crystal sample of CoTiO 3 as a function of temperature. CoTiO 3 is a honeycomb magnet with dominant XY-type magnetic interaction and an A-type antiferromagnetic order below T N ≈ 38 K. We found that the SO exciton becomes softer, but acquires a larger bandwidth in the paramagnetic phase, compared to that in the magnetically ordered phase. Moreover, an additional mode is only observed in the intermediate temperature range, as the sample is warmed up above the lowest accessible temperature below T N . Such an unusual temperature dependence observed in this material suggests that its ground states (an S eff = 1 2 doublet) and excited states multiplets are strongly coupled, and therefore cannot be treated independently, as often done in a pseudo-spin model. Furthermore, our observations can be explained by a multi-level theory within random phase approximation that explicitly takes into account both the ground and excited multiplets. The success of our theory, which is originally developed to explain temperature dependence of magnetic excitations in the rare-earth magnets, highlight the similarity between the magnetic excitations in rare-earth systems and those in transition metal systems with strong spin orbit coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photooxidative decomposition and defluorination of perfluorooctanoic acid (PFOA) using an innovative technology of UV–vis/Zn x Cu 1-x Fe 2 O 4 /oxalic acid

Per- and polyfluoroalkyl substances (PFAS) are a large group of perfluorinated organic molecules that have been in use since the 1940s for industrial, commercial, and consumer applications. PFAS are a growing concern because some of them have shown persistent, bioaccumulative and toxic effects. In this work, we demonstrate an innovative technology of UV–vis/Zn x Cu 1-x Fe 2 O 4 /oxalic acid for the degradation of perfluorooctanoic acid (PFOA) in water. The magnetically retrievable nanocrystalline heterogeneous ferrite catalysts, Zn x Cu 1-x Fe 2 O 4 were synthesized using a sol-gel auto-combustion process followed by calcination at 400 °C. The combination of Zn x Cu 1-x Fe 2 O 4 and oxalic acid generate reactive species under UV light irradiation. These reactive species are then shown to be capable of the photodegradation of PFOA. The degree of degradation is tracked by identifying transformation products using liquid chromatography coupled with quadrupole time-of-flight mass spectroscopy (LC-QTOF-MS).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An overview of the first principles studies of doped RE-TM5 systems for the development of hard magnetic properties

In this study, we compiled all the first principles calculations performed on RE-TM 5 (RE: rare earth, TM: transition metal) system to address the following question: Has everything been tried to improve the hard magnetic properties of this special intermetallic compound, and are there any venues that are worth pursuing? As it is the case with the first principles studies in any field, they are driven mainly by experimental work: (i) to validate their results, and (ii) to extend our understanding of the underlying physical phenomena so that the theory in hand can be used as a predictive tool to shed light on certain what-if scenarios. Our analysis indicates that three major compounds are investigated more than others: (1) YCo 5 , because it can potentially be an intermediate-performance hard magnet, and the presence of yttrium with no localized 4f electrons simplifies calculations significantly, (2) SmCo 5 , because it has the largest magnetic anisotropy energy among all RE hard magnets as well as very impressive high temperature performance, (3) CeCo 5 , because Ce is the most abundant rare earth element with a curious 4f electron behavior that gives rise to pronounced deviations in its structural and magnetic properties across the lanthanides series. This is followed by a brief analysis of several ab initio approaches that were developed to treat these rather complicated systems both at 0 K and at finite temperatures. Towards the end, we elucidate the role of exchange-correlation approximations such as local density approximations (LDA) and generalized gradient approximation (GGA) formulation in determining the MAE and M s by analyzing their corresponding density of states (DOS), and providing our results on a rather overlooked hard-magnetic material: LaCo 5 .

36 MATERIALS SCIENCE↗

Magnetic In-Vacuum Field Mapping System for the Muon g-2 Experiment

The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon, $a^{}_\mu$ with a precision of 140ppb, a four-fold improvement over the former BNL E821 result. If the current discrepancy of about 3.5$\sigma$ between the Standard Model value for $a^{}_\mu$ and the former experiments was real, then the new experiment would verify the deviation with >7$\sigma$ significance. The experiment uses muons with the magic momentum of 3.09GeV/c stored in a very homogeneous magnetic field of a 45m long storage ring. The determination of $a^{}_\mu$ requires the precise knowledge of both the muon spin precession, $\omega^{}_a$, and the magnetic field, $\omega^{}_p$, expressed in terms of the free-proton Larmor frequency. The field measurement uses the high precision tool of pulsed proton Nuclear Magnetic Resonance and requires cross-calibrating a set of probes: a very accurate NMR probe calibrates the 17 probes on the in-vacuum field mapping system (the so-called trolley). This trolley in turn is used to map the field over the full azimuth of the storage ring. The trolley measurement also provides the calibration of the 378 fixed probes around the ring that constantly monitor the field drift. The trolley is particularly important as it measures the relevant field that is seen by the stored muons and this article presents the details of this field mapping system. This work was supported in part by the US DOE, Fermilab and US DOE OHEP under contract No. KA2201020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of magnetic bracelets on the coagulation and anticoagulation systems of the blood of patients with hypertension

The data which have been obtained on the influence of magnetic bracelets on the coagulation and anticoagulation systems of the blood indicate that the wearing of magnetic bracelets results in a decrease in the coagulation activity of the blood and an increase in the activity of the anticoagulation system. These changes must be viewed as favorable for patients with cardiovascular pathology.

Bublis, V. V.↗

Advancement of hybrid fluid-kinetic modeling for HEDP and ICF science

We report on the development progress of a hybrid fluid-kinetic code for simulating fluids and plasmas in a wide range of environments, such as laser–matter interactions, inertial confinement fusion, magnetic confinement fusion, and pulsed power. The suite of numerical tools under development utilizes heterogeneous computer architectures and leverages the benefits of particle–based simulation techniques. By working to combine the kinetic particle-in-cell (PIC) model with a particle-based fluid simulation technique, such as smoothed particle hydrodynamics, we are developing a flexible framework capable of accurately modeling complex flows within and between kinetic and fluid regimes. The TriForce code is under development as a C++ framework for parallel, 3D, particle-based, hybrid fluid-kinetic plasma simulations. The fluid half of TriForce will be based upon the meshless smoothed-particle-hydrodynamics (SPH) approach, well-suited for shear, mixing, and turbulence, whereas the kinetic half resembles a traditional particle-in-cell (PIC) code; other particle-based approaches to fluid modeling that do use a mesh are also possible to use and are under investigation. Maxwell’s electromagnetic field equations are solved either via explicit or implicit algorithms or approximated via resistive magnetohydrodynamics (MHD) using an Ohm’s law and resulting induction equation (extended MHD is under development). A primary goal of enabling direct comparisons, from the same code, between results from the variants of MHD and implicit electromagnetic solutions is to improve our fundamental understanding of systems with magnetic fields. The code is under development to recover results from both radiation-MHD and fully kinetic codes in those limits, and is continuing to be developed from other follow-on grants to operate in between where both descriptions may co-exist and interact. For certain applications, it is desired for a simulation to contain fluid ions and electrons as well as kinetic ions and electrons. Typically, it is too computationally intensive to model a full-scale ICF or HEDP experiment fully kinetically since many cycles are expended with very small time steps on modeling the fluid part of a material that is well treated by the fluid approximation. In this case, many traditional PIC particles can be replaced with a single fluid particle representing the thermal part of the distribution function, and there are fewer needed kinetic particles, which describe the non-thermal part and can be sub-cycled relative to the fluid particle advance. Furthermore, a pure fluid code may, depending on the problem, simply lack many physically important details that are beyond the scope of its reduced approximations and assumptions. In this report, we summarize the objectives achieved in the development of the collisional and kinetic half of the code, and the physics problems to which the code has been applied in the areas of advanced and innovative fusion concepts, pulsed power, and magneto-inertial fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STS-61 Space Shuttle mission report

The STS-61 Space Shuttle Program Mission Report summarizes the Hubble Space Telescope (HST) servicing mission as well as the Orbiter, External Tank (ET), Solid Rocket Booster (SRB), Redesigned Solid Rocket Motor (RSRM), and the Space Shuttle main engine (SSME) systems performance during the fifty-ninth flight of the Space Shuttle Program and fifth flight of the Orbiter vehicle Endeavour (OV-105). In addition to the Orbiter, the flight vehicle consisted of an ET designated as ET-60; three SSME's which were designated as serial numbers 2019, 2033, and 2017 in positions 1, 2, and 3, respectively; and two SRB's which were designated BI-063. The RSRM's that were installed in each SRB were designated as 360L023A (lightweight) for the left SRB, and 360L023B (lightweight) for the right SRB. This STS-61 Space Shuttle Program Mission Report fulfills the Space Shuttle Program requirement as documented in NSTS 07700, Volume 8, Appendix E. That document requires that each major organizational element supporting the Program report the results of its hardware evaluation and mission performance plus identify all related in-flight anomalies. The primary objective of the STS-61 mission was to perform the first on-orbit servicing of the Hubble Space Telescope. The servicing tasks included the installation of new solar arrays, replacement of the Wide Field/Planetary Camera I (WF/PC I) with WF/PC II, replacement of the High Speed Photometer (HSP) with the Corrective Optics Space Telescope Axial Replacement (COSTAR), replacement of rate sensing units (RSU's) and electronic control units (ECU's), installation of new magnetic sensing systems and fuse plugs, and the repair of the Goddard High Resolution Spectrometer (GHRS). Secondary objectives were to perform the requirements of the IMAX Cargo Bay Camera (ICBC), the IMAX Camera, and the Air Force Maui Optical Site (AMOS) Calibration Test.

Fricke, Robert W., Jr.↗