Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

A Hardware Platform for Studying Naval Power Electronic Power Distribution Systems

Abstract – Future intelligent ship system designs will likely include electric propulsion, numerous highpower sensors, and directed energy weapons. Supply and control of these large nonlinear loads will require a networked, multi-converter power electronic power distribution system. This work presents a hardware platform to emulate a microgrid power system with multiple power converters and a power data communication network. The platform is reconfigurable and can include both AC and DC power distribution zones, representative of shipboard power systems. It also allows for the study of both power control actuation and power data communication delays. Since the platform is based on electric power hardware, spatial and temporal uncertainties are inherently embedded in the system. Specifically, this work examines the control actuation of multiple pulsed power loads in a single microgrid. Several pulse load levels and operating scenarios have been implemented and measured. A framework for control parameter quantification is presented, and various metrics are explored to capture pulse signal characteristics. The sensitivity of pulse load metric parameters is analyzed. Dynamic shipboard, mission-specific load profiles coupled with pulse loads can also be emulated in the hardware platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strengthening mechanisms for microstructures containing unimodal and bimodal γ' precipitates in ATI 718Plus

Here, the influence of γ' precipitate size distribution on the deformation mechanisms under tensile loading in ATI 718Plus was studied. A set of aging treatments within the temperature range of 720 °C–900 °C was performed on solution-treated samples to obtain various γ' precipitate size distributions. Unimodal and bimodal γ' precipitate size distributions were achieved through single-step and two-step aging sequences, respectively, and such microstructures were tensile tested to failure to assess their yield strength, ultimate tensile strength, and elongation-to-failure. Some of the tensile samples were interrupted after achieving 3–4 % plastic strain, and the deformed microstructures were examined using transmission electron microscopy to investigate the γ' precipitate-dislocation interactions. For the unimodal γ' precipitate size distribution samples with the smaller γ' precipitates (radius ~ 7 nm), dislocations sheared through the precipitates. Both dislocation loops and paired dislocations were observed for the microstructures containing larger γ' precipitates (radius ~ 24 nm). The microstructure containing a bimodal γ' precipitate size distribution, which included average γ' precipitate radii of ~6 nm and ~28 nm, exhibited shearing as the dominant deformation mechanism, and this microstructure exhibited the highest strength values. The experimental observations were rationalized based on the theoretically-calculated critical resolved shear stress values for shearing and looping and a modified model for predicting the yield strength for bimodal microstructures was introduced.

36 MATERIALS SCIENCE↗

A design procedure for the phase-controlled parallel-loaded resonant inverter

High-frequency-link power conversion and distribution based on a resonant inverter (RI) has been recently proposed. The design of several topologies is reviewed, and a simple approximate design procedure is developed for the phase-controlled parallel-loaded RI. This design procedure seeks to ensure the benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. The load is considered to be a linear impedance (or an ac current sink). The design procedure is verified using a 2.5-kVA 20-kHz RI. Also obtained are predictable worst-case ratings for each component of the resonant tank circuit and the inverter switches. For a given load VA requirement, below-resonance operation is found to result in a significantly lower tank VA requirement. Under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible.

King, Roger J.↗

Integrated Stirling Convertor and Hall Thruster Test Conducted

An important aspect of implementing Stirling Radioisotope Generators on future NASA missions is the integration of the generator and controller with potential spacecraft loads. Some recent studies have indicated that the combination of Stirling Radioisotope Generators and electric propulsion devices offer significant trip time and payload fraction benefits for deep space missions. A test was devised to begin to understand the interactions between Stirling generators and electric thrusters. An electrically heated RG- 350 (350-W output) Stirling convertor, designed and built by Stirling Technology Company of Kennewick, Washington, under a NASA Small Business Innovation Research agreement, was coupled to a 300-W SPT-50 Hall-effect thruster built for NASA by the Moscow Aviation Institute (RIAME). The RG-350 and the SPT-50 shown, were installed in adjacent vacuum chamber ports at NASA Glenn Research Center's Electric Propulsion Laboratory, Vacuum Facility 8. The Stirling electrical controller interfaced directly with the Hall thruster power-processing unit, both of which were located outside of the vacuum chamber. The power-processing unit accepted the 48 Vdc output from the Stirling controller and distributed the power to all the loads of the SPT-50, including the magnets, keeper, heater, and discharge. On February 28, 2001, the Glenn test team successfully operated the Hall-effect thruster with the Stirling convertor. This is the world's first known test of a dynamic power source with electric propulsion. The RG-350 successfully managed the transition from the purely resistive load bank within the Stirling controller to the highly capacitive power-processing unit load. At the time of the demonstration, the Stirling convertor was operating at a hot temperature of 530 C and a cold temperature of -6 C. The linear alternator was producing approximately 250 W at 109 Vac, while the power-processing unit was drawing 175 W at 48 Vdc. The majority of power was delivered to the Hall thruster discharge circuit operating at 115 Vdc and 0.9 A. Testing planned for late 2001 will examine the possibility of directly driving the Hall thruster discharge circuit using rectified and filtered output from the Stirling alternator.

Mason, Lee S.↗

Effect of workpiece curvature on the tool influence function during hemispherical sub-aperture tool glass polishing

The influence of workpiece curvature on the tool influence function spot during polishing of fused silica glass with cerium oxide slurry, while using a rotating hemispherical pad-foam tool for a wide variety of process conditions (tool displacement, inclination angle, and rotation rate), has been investigated. (Workpiece curvature ranged from 500 mm radius concave to 43 mm radius convex.) The TIF spot decreases in diameter and increases in the peak removal rate on more convex workpieces. In contrast, the TIF spot increases both in diameter and peak removal rate on more concave workpieces. For the range of workpiece curvatures investigated, both the spot size and the peak removal rate changed significantly, as much as 2 times. An elastic sphere–sphere contact mechanics model, which utilizes both a modified displacement (that leads to a change in the applied load) as well as a mismatch factor (that influences the pressure distribution shape), has been developed. Furthermore, the model was validated using both offline load-displacement measurements and finite-element analysis simulations. The model quantitatively describes the measured change in the relative contact diameter and relative pressure distribution, as well as semiquantitively describes the change in the relative volumetric removal rate on a large variety of TIF spots. The change in the volumetric removal rate for convex workpieces is a result of the balance between a decreasing spot size (reducing removal) and an increasing peak pressure (increasing removal), which usually results in relatively small changes in volumetric removal. In the case of concave workpieces, the volumetric removal rate change is also governed by a similar balance, but the spot size increase contribution dominates, resulting in a significant increase in volumetric removal rate. Understanding these trends can enable methods to add greater determinism during the fabrication of freeform optics by adjusting polishing parameters (such as dwell time) while the tool translates along a workpiece surface with different local curvatures.

47 OTHER INSTRUMENTATION↗

Dust-planetary boundary layer interactions amplified by entrainment and advections

Mineral dust contributes to more than half of the global aerosol loading. However, the radiative impacts of dust aerosols on planetary boundary layer (PBL) structure have not been explored sufficiently. During a typical dust storm event over Tarim Basin, dust aerosols exhibit a well-mixed distribution during the daytime in spite of a shallow layer of dust particles accumulated at higher altitudes. By contrast, nocturnal dust plumes are located near the surface due to stable stratification. We demonstrate that these differentiated vertical distributions determine the spatial heterogeneity of dust loading, radiative fluxes and PBL height variations. Dust aerosols cause daytime PBL suppression and nighttime PBL promotion through modulating surface and atmospheric radiative budgets. Specifically, dust-induced cooling effect within PBL directly inhibits the daytime PBL development. PBL suppression effect is then amplified by entrainment processes resulting in excessively low PBL height, especially for dust particles below but near the PBL top. Dust plumes weaken updrafts from PBL and downdrafts of the free atmosphere, which further reduce the entrainment mixing through attenuating horizontal and vertical advection, and eventually amplify PBL suppression. At night, near-surface dust aerosols stimulate a warm and unstable lower atmosphere, generate warm advection heating and promote the PBL development. Our study highlights the importance of specifying entrainment parameters and nighttime advection activities in quantifying the dust-PBL interactions.

54 ENVIRONMENTAL SCIENCES↗

Electric power processing, distribution and control for advanced aerospace vehicles.

The results of a current study program to develop a rational basis for selection of power processing, distribution, and control configurations for future aerospace vehicles including the Space Station, Space Shuttle, and high-performance aircraft are presented. Within the constraints imposed by the characteristics of power generation subsystems and the load utilization equipment requirements, the power processing, distribution and control subsystem can be optimized by selection of the proper distribution voltage, frequency, and overload/fault protection method. It is shown that, for large space vehicles which rely on static energy conversion to provide electric power, high-voltage dc distribution (above 100 V dc) is preferable to conventional 28 V dc and 115 V ac distribution per MIL-STD-704A. High-voltage dc also has advantages over conventional constant frequency ac systems in many aircraft applications due to the elimination of speed control, wave shaping, and synchronization equipment.

Krausz, A.↗

Efficient Region of Attraction Characterization for Control and Stabilization of Load Tap Changer Dynamics

In this article, we study the monitoring and control of long-term voltage stability considering load tap changer (LTC) dynamics. We show that under generic conditions, the LTC dynamics admit a unique stable equilibrium. For the stable equilibrium, we characterize an explicit inner approximation of its largest region of attraction (ROA). Compared to existing results, the computational complexity of the ROA characterization is drastically reduced. We propose a quadratically constrained linear program formulation for the ROA characterization problem. In addition, we formulate a second-order cone program for online voltage stability monitoring and control exploiting the proposed ROA characterization. Finally, we demonstrate the efficacy of the proposed formulations on the ROA characterization and stability monitoring and control using a standard IEEE test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proposed Use of the NASA Ames Nebula Cloud Computing Platform for Numerical Weather Prediction and the Distribution of High Resolution Satellite Imagery

The development of the Nebula Cloud Computing Platform at NASA Ames Research Center provides an open-source solution for the deployment of scalable computing and storage capabilities relevant to the execution of real-time weather forecasts and the distribution of high resolution satellite data to the operational weather community. Two projects at Marshall Space Flight Center may benefit from use of the Nebula system. The NASA Short-term Prediction Research and Transition (SPoRT) Center facilitates the use of unique NASA satellite data and research capabilities in the operational weather community by providing datasets relevant to numerical weather prediction, and satellite data sets useful in weather analysis. SERVIR provides satellite data products for decision support, emphasizing environmental threats such as wildfires, floods, landslides, and other hazards, with interests in numerical weather prediction in support of disaster response. The Weather Research and Forecast (WRF) model Environmental Modeling System (WRF-EMS) has been configured for Nebula cloud computing use via the creation of a disk image and deployment of repeated instances. Given the available infrastructure within Nebula and the "infrastructure as a service" concept, the system appears well-suited for the rapid deployment of additional forecast models over different domains, in response to real-time research applications or disaster response. Future investigations into Nebula capabilities will focus on the development of a web mapping server and load balancing configuration to support the distribution of high resolution satellite data sets to users within the National Weather Service and international partners of SERVIR.

Limaye, Ashutosh S.↗

Local measurements of the spatial magnetic field distribution in a z-pinch plasma during and near stagnation using polarization spectroscopy

We present here the detailed measurements of radial distribution of the magnetic field in a gas-puff z-pinch plasma at the final stages of the implosion phase and at stagnation. While the measurements are chordal, the radial distribution of different charge states was utilized to measure the magnetic field locally for certain radii, so that unlike chordal measurements in general, the magnetic field radial distribution was obtained with no need for the Abel inversion of the data. The distribution was measured using the Zeeman effect via a novel spectroscopic technique, at several axial locations, and demonstrates striking features such as the peak field remaining at a radius much larger than the stagnation radius at all times. Furthermore, while the distribution observed is sometimes monotonic with respect to the radius, it is often not, a behavior that can be linked to 2D features in the plasma column resulting from the Rayleigh–Taylor instability. The current flowing through the stagnating plasma was found to be a small fraction of the total current, resulting in clearly insufficient magnetic pressure to balance the plasma pressure at stagnation. The magnetic field data, taken over several axial positions, are used to obtain the true inductance in the imploding plasma for the first time; it is found that the data cannot explain the current turnover at stagnation. A simulation with the MACH2-Tabular Collisional-Radiative Equilibrium magnetohydrodynamics code in the r–z plane shows that the peak of the magnetic field pinches to a much smaller radius than is observed in the spectroscopic data. Furthermore, the depth of the computed current turnover at stagnation is smaller than the measured one. The two observed features of a radially extended magnetic field at stagnation together with a deep current turnover are a challenge to match in simulations. Various calculations and estimates of the inductive and resistive load voltages are examined to ascertain if they are responsible for the observed current notch. Lastly, the results demonstrate that the knowledge of the true inductance in the driven load requires such magnetic-field-distribution measurements and that imaging data or electrical measurements are insufficient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

Loss-of-Coolant Accident Analysis of a High-Burnup Pressurized Water Reactor Core Design Using Gadolinia-Doped UO 2

High-burnup and extended enrichment fuels are of interest for extending the cycle lengths of pressurized water reactors from 18 to 24 months. Changes to the fuel design and core loading scheme have potentially significant safety implications due to power distribution effects, reduced thermal conductivity, and/or increased plenum pressures due to additional burnable poison loadings. Additionally, higher burnups result in increased material degradation and risk of fuel fragmentation, relocation, and dispersal (FFRD). A representative 24-month core design using gadolinia-doped UO 2 was analyzed for performance under large-break (LB) loss-of-coolant accident (LOCA) conditions using PARCS, RELAP5-3D, and BISON. Furthermore, all considered acceptance criteria were met, with no cases exceeding the 1477 K maximum cladding temperature or the post-quench ductility oxidation limit of 17% equivalent cladding reacted. Full-core FFRD susceptibility was estimated to be approximately 455 kg, though high uncertainties exist with current approaches for computing susceptibility. Undoped fuel rods are more likely to be limiting due to higher linear heat rates. Relatively high burnup and linear heat rate rods located in second batch assemblies are of greatest safety significance during LB LOCA for this high-burnup core design.

High burnup↗

Reliability-Based Design Optimization of a Composite Airframe Component

A stochastic design optimization methodology (SDO) has been developed to design components of an airframe structure that can be made of metallic and composite materials. The design is obtained as a function of the risk level, or reliability, p. The design method treats uncertainties in load, strength, and material properties as distribution functions, which are defined with mean values and standard deviations. A design constraint or a failure mode is specified as a function of reliability p. Solution to stochastic optimization yields the weight of a structure as a function of reliability p. Optimum weight versus reliability p traced out an inverted-S-shaped graph. The center of the inverted-S graph corresponded to 50 percent (p = 0.5) probability of success. A heavy design with weight approaching infinity could be produced for a near-zero rate of failure that corresponds to unity for reliability p (or p = 1). Weight can be reduced to a small value for the most failure-prone design with a reliability that approaches zero (p = 0). Reliability can be changed for different components of an airframe structure. For example, the landing gear can be designed for a very high reliability, whereas it can be reduced to a small extent for a raked wingtip. The SDO capability is obtained by combining three codes: (1) The MSC/Nastran code was the deterministic analysis tool, (2) The fast probabilistic integrator, or the FPI module of the NESSUS software, was the probabilistic calculator, and (3) NASA Glenn Research Center s optimization testbed CometBoards became the optimizer. The SDO capability requires a finite element structural model, a material model, a load model, and a design model. The stochastic optimization concept is illustrated considering an academic example and a real-life raked wingtip structure of the Boeing 767-400 extended range airliner made of metallic and composite materials.

Patnaik, Surya N.↗

Design trade-offs for residential retail tariffs and virtual power plants

Retail rate design and virtual power plants (VPPs) have the potential to shift customer electricity demand and provide economic benefits to utility customers. As the adoption of distributed energy resources (DERs) and flexible loads increases, retail tariff and program design can impact Bonbright's rate design principles including affordability, fairness, and economic efficiency. We model the effects of residential retail rates and VPP programs on power system costs in Massachusetts under a potential future system with high renewable energy and DER adoption. We model interactions among retail rate design, demand flexibility, and utility costs and identify trade-offs across different rate designs and VPP programs. We estimate that time-of-use (TOU) rates and VPP programs designed to avoid critical peak rates can lower overall system costs by 3.5 %-4.8 %. These lower costs translate to lower electricity bills for 62 %-91 % of customers, depending on the scenario. Although TOU rates with a critical peak VPP program can benefit all customer segments and are economically efficient, a VPP program with flat rates leads to the lowest overall bills for customers. We find that customers with loads that align with peak demand and who participate in critical peak VPP programs can underpay for their contribution to utility costs and shift costs to other customers. While our assumptions about mandatory TOU and/or critical peak pricing likely impact the magnitude of the results, the results highlight the trade-offs of these tariffs and programs and the importance of tariff and program design as demand becomes more flexible and responsive.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load altering attack-tolerant defense strategy for load frequency control system

Cyber attacks are emerging threats to every information-oriented energy management system. By violating the cyber systems, the hacker can disrupt the security and stability due to the strong coupling between the cyber and physical facilities. In this paper, one type of cyber attacks designated as the load altering attack is studied for the power system frequency control, and corresponding defense strategies are proposed to improve the frequency control performance. Considering the difficulty of the application of model-based controller into large-scale power systems, a novel model-free defense framework is for the first time presented. Under this framework, both active defense and passive defense strategies are designed. The former assumes that the defender has the initiative to learn different attack scenarios. Adaptive defense strategies are implemented using the online attack identification information and off-line trained strategy pool. The latter assumes that the defender passively tolerates various attack scenarios via the pre-trained off-line strategy. Both approaches prove to be effective through validation based on the IEEE benchmark systems. The proposed defense framework and defense strategies can be extended to other energy control systems to enhance their attack tolerance capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Stability Considerations for Virtual Capacitor Control in Constant Power DC Loads

In a DC grid, constant power loads (CPLs) necessitate a large bus capacitor to prevent negative impedance instability. Some of the capacitance can be realized virtually through CPL control to reduce the bus capacitor size. Here, this paper analytically studies system stability with virtual capacitor control. We demonstrate that the effectiveness of virtual capacitor control is highly sensitive to the implementation of the derivative action required to emulate the capacitor. For the first time, we theoretically demonstrate that a virtual capacitor can stabilize the system without any physical bus capacitor, provided that a set of analytically derived conditions are met. However, this stabilization is not achievable in practice due to the influence of non-idealities. In an example system requiring a $14$ mF capacitor to stably support the CPL, we show that stability can be achieved through virtual capacitor control, using only a 2 mF physical capacitor to account for the switching ripple non-idealities. Hardware-in-the-loop tests verify the analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗