Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Performance characterization of microtomography with complementary metal-oxide-semiconductor detectors for computer-aided defect inspection

We developed a computer-aided defect inspection system based on computed tomography (CT). The system consists of a homemade small cone-beam CT (CBCT) system and a graphical toolbox, which is used to extract a computer-aided design (CAD) model from the CT data. In the small CBCT system, the x-ray imaging detector is based on a complementary metal-oxide-semiconductor photodiode array in conjunction with a scintillator. Imaging performance of the detector was evaluated in terms of modulation-transfer function, noise-power spectrum, and detective quantum efficiency. The tomographic imaging performance of the small CBCT system was evaluated in terms of signal-to-noise ratio and contrast-to-noise ratio. The graphical toolbox to support defect inspection incorporates various functional tools such as volume rendering, segmentation, triangular-mesh data generation, and data reduction. All the tools have been integrated in a graphical-user interface form. The developed system can provide rapid visual inspection as well as quantitative evaluation of defects by comparing the extracted CAD file with the original file, if available, of an object. The performance of the developed system is demonstrated with experimental CT volume data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser ablation tomography for visualization of root colonization by edaphic organisms

Soil biota have important effects on crop productivity, but can be difficult to study in situ . Laser ablation tomography (LAT) is a novel method that allows for rapid, three-dimensional quantitative and qualitative analysis of root anatomy, providing new opportunities to investigate interactions between roots and edaphic organisms. LAT was used for analysis of maize roots colonized by arbuscular mycorrhizal fungi, maize roots herbivorized by western corn rootworm, barley roots parasitized by cereal cyst nematode, and common bean roots damaged by Fusarium . UV excitation of root tissues affected by edaphic organisms resulted in differential autofluorescence emission, facilitating the classification of tissues and anatomical features. Samples were spatially resolved in three dimensions, enabling quantification of the volume and distribution of fungal colonization, western corn rootworm damage, nematode feeding sites, tissue compromised by Fusarium , and as well as root anatomical phenotypes. Owing to its capability for high-throughput sample imaging, LAT serves as an excellent tool to conduct large, quantitative screens to characterize genetic control of root anatomy and interactions with edaphic organisms. Additionally, this technology improves interpretation of root–organism interactions in relatively large, opaque root segments, providing opportunities for novel research investigating the effects of root anatomical phenes on associations with edaphic organisms.

60 APPLIED LIFE SCIENCES↗

Semiconductor detectors with proximity signal readout

Semiconductor-based radiation detectors are routinely used for the detection, imaging, and spectroscopy of x-rays, gamma rays, and charged particles for applications in the areas of nuclear and medical physics, astrophysics, environmental remediation, nuclear nonproliferation, and homeland security. Detectors used for imaging and particle tracking are more complex in that they typically must also measure the location of the radiation interaction in addition to the deposited energy. In such detectors, the position measurement is often achieved by dividing or segmenting the electrodes into many strips or pixels and then reading out the signals from all of the electrode segments. Fine electrode segmentation is problematic for many of the standard semiconductor detector technologies. Clearly there is a need for a semiconductor-based radiation detector technology that can achieve fine position resolution while maintaining the excellent energy resolution intrinsic to semiconductor detectors, can be fabricated through simple processes, does not require complex electrical interconnections to the detector, and can reduce the number of required channels of readout electronics. Proximity electrode signal readout (PESR), in which the electrodes are not in physical contact with the detector surface, satisfies this need.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling blur in various detector geometries relevant to DARHT

Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for MeV radiography which are applicable to DARHT. Segmented scintillator detectors, where low Z scintillators combined with a high-Z metal matrix, are designed such that the resolution increases with increasing metal fraction. The combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution which degrades with plate number. Excellent agreement between simulation and experimental modulation transfer functions for select detector geometries was found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-term Study of the Solar Filaments from the Synoptic Maps as Derived from H{sub α} Spectroheliograms of the Kodaikanal Observatory

The century long (1914–2007) H{sub α} (656.28 nm) spectroheliograms from the Kodaikanal Solar Observatory (KSO) have been recently digitized. Using these newly calibrated, processed images we study the evolution of dark elongated on-disk structures called filaments, which are potential representatives of magnetic activities on the Sun. To our knowledge, this is the oldest uniform digitized data set with daily images available today in H{sub α}. We generate Carrington maps for the entire time duration and try to find the correlations with maps of the same Carrington rotation from the Ca ii K KSO data. Filaments are segmented from the Carrington maps using a semi-automated technique and are studied individually to extract their centroids and tilts. We plot the time-latitude distribution of the filament centroids, producing a butterfly diagram which clearly shows the presence of poleward migration. We separate polar filaments for each cycle and try to estimate the delay between the polar filament number cycle and the sunspot number cycle peaks. We correlate this delay with the delay between polar reversal and sunspot number maxima. This provides new insight on the role of polar filaments on polar reversal.

79 ASTRONOMY AND ASTROPHYSICS↗

Dosimetric accuracy of a deterministic radiation transport based {sup 192}Ir brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicator

Purpose: The aim of this work is the dosimetric validation of a deterministic radiation transport based treatment planning system (BRACHYVISION v. 8.8, referred to as TPS in the following) for multiple {sup 192}Ir source dwell position brachytherapy applications employing a shielded applicator in homogeneous water geometries. Methods: TPS calculations for an irradiation plan employing seven VS2000 {sup 192}Ir high dose rate (HDR) source dwell positions and a partially shielded applicator (GM11004380) were compared to corresponding Monte Carlo (MC) simulation results, as well as experimental results obtained using the VIP polymer gel-magnetic resonance imaging three-dimensional dosimetry method with a custom made phantom. Results: TPS and MC dose distributions were found in agreement which is mainly within {+-}2%. Considerable differences between TPS and MC results (greater than 2%) were observed at points in the penumbra of the shields (i.e., close to the edges of the ''shielded'' segment of the geometries). These differences were experimentally verified and therefore attributed to the TPS. Apart from these regions, experimental and TPS dose distributions were found in agreement within 2 mm distance to agreement and 5% dose difference criteria. As shown in this work, these results mark a significant improvement relative to dosimetry algorithms that disregard the presence of the shielded applicator since the use of the latter leads to dosimetry errors on the order of 20%-30% at the edge of the ''unshielded'' segment of the geometry and even 2%-6% at points corresponding to the potential location of the target volume in clinical applications using the applicator (points in the unshielded segment at short distances from the applicator). Conclusions: Results of this work attest the capability of the TPS to accurately account for the scatter conditions and the increased attenuation involved in HDR brachytherapy applications employing multiple source dwell positions and partially shielded applicators.

60 APPLIED LIFE SCIENCES↗

A Method to Automate the Segmentation of the GTV and ITV for Lung Tumors

Four-dimensional computed tomography (4D-CT) is a useful tool in the treatment of tumors that undergo significant motion. To fully utilize 4D-CT motion information in the treatment of mobile tumors such as lung cancer, autosegmentation methods will need to be developed. Using autosegmentation tools in the Pinnacle{sup 3} v8.1t treatment planning system, 6 anonymized 4D-CT data sets were contoured. Two test indices were developed that can be used to evaluate which autosegmentation tools to apply to a given gross tumor volume (GTV) region of interest (ROI). The 4D-CT data sets had various phase binning error levels ranging from 3% to 29%. The appropriate autosegmentation method (rigid translational image registration and deformable surface mesh) was determined to properly delineate the GTV in all of the 4D-CT phases for the 4D-CT data sets with binning errors of up to 15%. The ITV was defined by 2 methods: a mask of the GTV in all 4D-CT phases and the maximum intensity projection. The differences in centroid position and volume were compared with manual segmentation studies in literature. The indices developed in this study, along with the autosegmentation tools in the treatment planning system, were able to automatically segment the GTV in the four 4D-CTs with phase binning errors of up to 15%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simple Carotid-Sparing Intensity-Modulated Radiotherapy Technique and Preliminary Experience for T1-2 Glottic Cancer

Purpose: To investigate the dosimetry and feasibility of carotid-sparing intensity-modulated radiotherapy (IMRT) for early glottic cancer and to report preliminary clinical experience. Methods and Materials: Digital Imaging and Communications in Medicine radiotherapy (DICOM-RT) datasets from 6 T1-2 conventionally treated glottic cancer patients were used to create both conventional IMRT plans. We developed a simplified IMRT planning algorithm with three fields and limited segments. Conventional and IMRT plans were compared using generalized equivalent uniform dose and dose-volume parameters for in-field carotid arteries, target volumes, and organs at risk. We have treated 11 patients with this simplified IMRT technique. Results: Intensity-modulated radiotherapy consistently reduced radiation dose to the carotid arteries (p < 0.05) while maintaining the clinical target volume coverage. With conventional planning, median carotid V35, V50, and V63 were 100%, 100%, and 69.0%, respectively. With IMRT planning these decreased to 2%, 0%, and 0%, respectively (p < 0.01). Radiation planning and treatment times were similar for conventional radiotherapy and IMRT. Treatment results have been excellent thus far. Conclusions: Intensity-modulated radiotherapy significantly reduced unnecessary radiation dose to the carotid arteries compared with conventional lateral fields while maintaining clinical target volume coverage. Further experience and longer follow-up will be required to demonstrate outcomes for cancer control and carotid artery effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of simvastatin on vascular tone in porcine coronary artery: Potential role of the mitochondria

Statins induce acute vasorelaxation which may contribute to the overall benefits of statins in the treatment of cardiovascular disease. The mechanism underlying this relaxation is unknown. As statins have been shown to alter mitochondrial function, in this study we investigated the role of mitochondria in the relaxation to simvastatin. Relaxation of porcine coronary artery segments by statins was measured using isolated tissue baths. Mitochondrial activity was determined by measuring changes in rhodamine 123 fluorescence. Changes in intracellular calcium levels were determined in freshly isolated smooth muscle cells with Fluo-4 using standard epifluorescent imaging techniques. Simvastatin, but not pravastatin, produced a slow relaxation of the coronary artery, which was independent of the endothelium. The relaxation was attenuated by the mitochondrial complex I inhibitor rotenone (10 μM) and the complex III inhibitor myxothiazol (10 μM), or a combination of the two. The complex III inhibitor antimycin A (10 μM) produced a similar time-dependent relaxation of the porcine coronary artery, which was attenuated by rotenone. Changes in rhodamine 123 fluorescence showed that simvastatin (10 μM) depolarized the membrane potential of mitochondria in both isolated mitochondria and intact blood vessels. Simvastatin and antimycin A both inhibited calcium-induced contractions in isolated blood vessels and calcium influx in smooth muscle cells and this inhibition was prevented by rotenone. In conclusion, simvastatin produces an endothelium-independent relaxation of the porcine coronary artery which is dependent, in part, upon effects on the mitochondria. The effects on the mitochondria may lead to a reduction in calcium influx and hence relaxation of the blood vessel. - Highlights: • Simvastatin produces a relaxation of the porcine coronary artery. • This relaxation is inhibited by mitochondrial complex inhibitors. • Simvastatin alters mitochondrial membrane potential in intact blood vessels. • Simvastatin inhibits calcium influx in smooth muscle cells, prevented by a mitochondrial inhibitor. • Simvastatin-induced relaxations are dependent upon mitochondrial activity.

60 APPLIED LIFE SCIENCES↗

In-situ thermomechanical measurements during burst testing of Zr claddings using digital image correlation and infrared thermography techniques

Burst testing has long been a relied-on method for assessing fuel cladding materials in light-water reactoraccident scenarios. However, burst testing historically provided minimal in-situ observations beyond a few thermocouple readings, pressure from transducers, and post-test deformation measurements. Acquisition of full cladding thermomechanical data throughout a burst test would be invaluable to fuel system qualification, material model development and fuel performance code validation, such as the BISON fuel performance code. Recently, methodologies for simultaneously applying 2-dimensional digital image correlation and infrared thermography techniques to quantify the relationship between temperature, internal cladding pressure, and deformation during burst testing were developed. This work details results from the application of these techniques to burst testing of Zircaloy-4 cladding segments subjected to loss-of-coolant accident transients in an air environment. Two types of tests were performed with: (a) cladding segments connected to a fixed pressure reservoir as well as (b) closed systems where internal pressure increased during transients. In-situ thermomechanical measurements including strain and thermal gradient data are presented, demonstrating the effectiveness of applying combined surface measurement techniques to burst testing

Bell, Sam↗

TU-G-204-02: Automatic Sclerotic Bone Metastases Detection in the Pelvic Region From Dual Energy CT

Purpose: To automatically detect sclerotic bone metastases in the pelvic region using dual energy computed tomography (DECT). Methods: We developed a two stage algorithm to automatically detect sclerotic bone metastases in the pelvis from DECT for patients with multiple bone metastatic lesions and with hip implants. The first stage consists of extracting the bone and marrow regions by using a support vector machine (SVM) classifier. We employed a novel representation of the DECT images using multi-material decomposition, which represents each voxel as a mixture of different physical materials (e.g. bone+water+fat). Following the extraction of bone and marrow, in the second stage, a bi -histogram equalization method was employed to enhance the contrast to reveal the bone metastases. Next, meanshift segmentation was performed to separate the voxels by their intensity levels. Finally, shape-based filtering was performed to extract the possible locations of the metastatic lesions using multiple shape criteria. We used the following shape parameters: area, eccentricity, major and minor axis, perimeter and skeleton. Results: A radiologist with several years of experience with DECT manually labeled 64 regions consisting of metastatic lesions from 10 different patients. However, the patients had many more metastasic lesions throughout the pelvis. Our method correctly identified 46 of the marked 64 regions (72%). In addition, our method also identified several other lesions, which can then be validated by the radiologist. The missed lesions were typically very large elongated regions consisting of several islands of very small (<4mm) lesions. Conclusion: We developed an algorithm to automatically detect sclerotic lesions in the pelvic region from DECT. Preliminary assessment shows that our algorithm generated lesions agreeing with the radiologist generated candidate regions. Furthermore, our method reveals additional lesions that can be inspected by the radiologist, thereby, reducing radiologist effort in identifying all the lesions with poor contrast from the DECT images.

60 APPLIED LIFE SCIENCES↗

SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

60 APPLIED LIFE SCIENCES↗

A comprehensive clinical 3-dimensional dosimetric analysis of forward planned IMRT and conventional wedge planned techniques for intact breast radiotherapy

A forward planned intensity modulated technique was initiated for intact breasts radiotherapy (FPIMRT). Forty-three patients were selected to compare dose distributions achieved by FPIMRT to dose distributions produced by conventional wedge techniques (CW). For the simulation process, the treatment field margins were clinically defined by a physician, and a set of fiducial reference markers was placed on the patient. A computed tomography (CT) scan was then performed and the images were transferred to a 3-dimensional (3D) treatment planning system (TPS). The breast tissue was then contoured to allow for a quantitative dose volume analysis. The treatment plan was initially generated with conventional tangential beam arrangements and open fields. Multiple multileaf collimator (MLC) shaped segments were created for each tangential beam in an effort to produce dose homogeneity throughout the breast. 6-MV photon beams were used for treatment unless acceptable dose homogeneity could not be achieved due to large breast size. In this case, the beam energies of selected segments were modified to 15-MV. Once the FPIMRT plan was created, additional plans were generated using the same beam geometry and 2 tangential open fields with CW techniques and 15 deg. wedges (15DW), 30 deg. wedges (30DW), 45 deg. wedges (45 DW), and 60 deg. wedges (60DW). The dose distributions generated by the CW plans were then compared to the FPIMRT plan. This process was repeated for each patient, and the patient group was divided into 3 categories based on breast volume (small, medium, and large). Both point dose relationships, which compared global hot spot (GHS) magnitude and location and dose volume relationships, which compared breast volume coverage of the 105% and 110% isodose lines (IDL) relative to the prescribed dose (PD), were explored. For the patient group in our study, FPIMRT produced the smallest average GHS and the most evenly distributed location of GHS for all breast size categories when compared to all CW techniques. FPIMRT also produced the smallest average breast volume receiving greater than 105% of the PD (V{sub a105}) for the small- and medium-size breast patients and the smallest average breast volume receiving greater than 110% of the PD (V{sub a110}) for all breast size categories when compared to all CW techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Liver Stiffness After Radioembolization by Real-Time ShearWave™ Elastography: Preliminary Study

PurposeTo evaluate the effect of ShearWave™ elastography (SWE) for the assessment of liver fibrosis after radioembolization (RE) in patients with liver malignancies.Materials and MethodsWe prospectively examined the effects of SWE before and after RE in 17 adult patients, from June 2012 to September 2013. All patients underwent SWE within 1 month before and 3 months (96.3 ± 22.9 days) after RE. Measurements were taken in segments III, IV, V, and VI (lateral/medial left lobe and anterior/posterior right lobe, respectively). Liver stiffness was studied in the 39 treated segments.ResultsThe mean stiffness of liver tissue according to the pre-RE SWE measurements was not different from the post-RE SWE measurements in the segments that did not undergo RE. Conversely, segments treated with RE were significantly stiffer according to the post-RE SWE measurements (mean SWE 17.4 kPa) than according to the baseline measurements (7.0 kPa) (p < 0.001). Patients with hepatocellular carcinoma and preexisting infection with hepatitis B and C viruses had higher pre-embolization stiffness, and the post-embolization stiffness of the treated segments in these patients was higher than that in the remainder of the study population.ConclusionThese data suggest that SWE measurements of liver stiffness increase as early as the third month after RE. SWE could be used as a noninvasive complementary imaging method for preliminary assessment of liver fibrosis before and after RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detecting wetland changes in Shanghai, China using FORMOSAT and Landsat TM imagery

Understanding the state of wetland ecosystems and their changes at the national and local levels is critical for wetland conservation, management, decision-making, and policy development practices. This study analyzed the wetlands in Shanghai, a province-level city, using remote sensing, image processing, and geographic information systems (GIS) techniques based on the Chinese national wetland inventory procedure and standards. FORMOSAT imagery acquired in 2012 and Navy nautical charts of the Yangtze estuarine area were used in conjunction with object-oriented segmentation, expert interpretation, and field validation to determine wetland status. Landsat imagery from 1985, 1995, 2000, 2003 and 2013 as well as social-economic data collected from 1985 to 2013 were used to further assess wetland changes. In 2013, Shanghai contained 376,970.6 ha of wetlands, and 78.8% of all wetlands were in marine or estuarine systems. Estuarine waters comprised the single largest wetland category. Between the first national wetland inventory in 2003 and the second national wetland inventory in 2013, Shanghai lost 50,519.13 ha of wetlands, amounting to a mean annual loss rate of 1.2% or an 11.8% loss over the decade. Declines were proportionately higher in marine and estuarine wetlands, with an annual loss of 1.8%, while there was a sharp increase of 1882.6% in constructed water storage areas for human uses. Diking, filling, impoundment and reclamation, which are all attributable to the economic development and urbanization associated with population increases, were the major factors that explained the gain and loss of wetlands. Additional factors affecting wetland losses and gains include sediment trapping by the hydropower system, which reduces supply to the estuary and erodes wetlands, and sediment trapping by the jetties, spur dikes, and diversion bulwark associated with a navigation channel deepening project, which has the converse effect, increasing saltmarsh wetland area at Jiuduansha shoal by three times between 2000 and 2013.

Tian, Bo↗

Rain footprints on C-band synthetic aperture radar images of the ocean - Revisited

It is well known that rain leaves footprints on the sea surface that sometimes become visible on synthetic aperture radar (SAR) images. Rain cells can easily be detected on SAR images at all radar frequencies when they are associated with a downdraft pattern. But rain cells are not always associated with downdraft and rain can also occur in other forms, as stratified rain, rain bands, and squall lines. It turns out that radar signatures of rain at C-band are much more complex than at L- or X-band radar and that it is particularly difficult to identify unambiguously rain events on C-band SAR images acquired over the ocean. This is because C-band lies in the transition region where raindrops impinging onto the sea surface can increase (usually) or decrease the backscattered radar power and where volume scattering and attenuation by rain drops in the atmosphere are not always negligible (at very high rain rates). In order to get an insight into the physical mechanisms causing the C-band radar signatures of rain, we first revisit results obtained from historic laboratory and field experiments and multi-frequency/multi-polarization SAR data acquired during the SIR-C/X-SAR spaceshuttle mission in 1994. Then we analyze several C-band SAR images acquired by the European satellites Envisat and Sentinel-1A, and the Canadian satellite Radarsat-2 and compare them, whenever possible, with quasi-coincident and collocated weather radar images. The observational data show that, at low to medium rain rates, the main physical mechanism causing C-band radar signatures of rain is Bragg scattering at ring waves generated by the rain drops impinging onto the sea surface, which increase the radar backscatter. However, areas of increased radar backscatter are often accompanied by adjacent areas of decreased radar backscatter, which is due to attenuation of the Bragg waves by turbulence also generated by the impinging rain drops. Furthermore, we present a full-polarimetric Radarsat-2 SAR image of a rain cell together with a polarimetric decomposition analysis, which shows that the C-band radar signature of a rain cell is caused by surface scattering. The observation show that radar signatures of rain cells often contain segments, where the co-polarized as well the cross-polarized radar backscatter are strongly enhanced, which indicates non-Bragg scattering contributions to the scattering process. Furthermore, the polarimetric decomposition analysis shows that the C-band radar signature of a rain cell is dominated by surface scattering. Possible mechanisms, like scattering at splash products, are discussed. Whether the normalized radar cross section (NRCS) due to rain is increased or decreased depends on rain rate, wind speed, incidence angle, and history of the rain event. At low to moderate wind speeds (< 10 ms - 1 ) and low to medium high rain rates (< 50 mm h - 1 ), the NRCS is usually increased by up to 8 dB, and at high wind speeds (> 10 m s - 1 ) and low to high rain rates (but < 50 mm h - 1 ), the NRCS is usually decreased by up to 3 dB.

54 ENVIRONMENTAL SCIENCES↗

Modeling blur in various detector geometries for MeV radiography

Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for applications in MeV radiography. Segmented scintillating detectors, where low Z scintillators combined with a high-Z metal matrix, can be designed in which the resolution increases with increasing metal fraction. Here, the combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution. Select detector geometries were tested by comparing simulation and experimental modulation transfer functions to validate the approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovenous Laser Ablation of the Small Saphenous Vein Sparing the Saphenopopliteal Junction

To assess outcomes after endovenous laser ablation (EVLA) of the small saphenous vein (SSV). Retrospective review was performed of all consecutive EVLA procedures performed over a 39-month period at three neighboring vein practices for symptomatic, duplex ultrasound-proven incompetence of the SSV. EVLA was performed under ultrasound guidance with an 810- or 980-nm diode laser in continuous mode using the pullback method while sparing the deep, most cephalad segment of the SSV near the saphenopopliteal junction. Follow-up after EVLA included patient symptoms, physical examination, and duplex ultrasound. Pretreatment variables were similar across all three practices. EVLA was performed to treat 67 incompetent SSVs in 63 patients (86% women; mean age and 95% confidence interval, 50 {+-} 3 years; range, 20-82 years). Average energy delivered was 92 J/cm. Immediate technical success and occlusion of the treated vein at 1-2 weeks was 100%. Imaging follow-up length was 243 {+-} 65 days (range, 3-893 days). Clinical follow-up (243 {+-} 66 days) showed symptomatic improvement in 66 (99%) of 67 patients; one patient had recanalization with recurrent reflux by ultrasound (2%). Complications included one case of paresthesias lasting beyond 1 month of follow-up (2%) and three cases of superficial phlebitis (4%), but no deep vein thrombosis, skin burns, or other complications. Although ablation involved only the superficial portion of the SSV and spared its deep segment in the popliteal fossa, SSV occlusion typically extended up to the saphenopopliteal junction or to a gastrocnemial collateral, without popliteal vein involvement. EVLA of the SSV is safe and effective when the saphenopopliteal junction and popliteal fossa are avoided. This approach may help reduce the risk of paresthesias or other complications while maintaining low recanalization rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗