Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERCONNECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Wireless power transmission for battery charging

A wireless power transmission system is provided for high power applications. The power transmission system is comprised generally of a charging unit configured to generate an alternating electromagnetic field and a receive unit configured to receive the alternating electromagnetic field from the charging unit. The charging unit includes a power source; an input rectifier; an inverter; and a transmit coil. The transmit coil has a spirangle arrangement segmented into n coil segments with capacitors interconnecting adjacent coil segments. The receive unit includes a receive coil and an output rectifier. The receive coil also has a spirangle arrangement segmented into m coil segments with capacitors interconnecting adjacent coil segments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cellular computational platform and neurally inspired elements thereof

A cellular computational platform is disclosed that includes a multiplicity of functionally identical, repeating computational hardware units that are interconnected electrically and optically. Each computational hardware unit includes a reprogrammable local memory and has interconnections to other such units that have reconfigurable weights. Each computational hardware unit is configured to transmit signals into the network for broadcast in a protocol-less manner to other such units in the network, and to respond to protocol-less broadcast messages that it receives from the network. Each computational hardware unit is further configured to reprogram the local memory in response to incoming electrical and/or optical signals.

97 MATHEMATICS AND COMPUTING↗

Drones in Automation - Secured Unmanned Aerial Systems

Factories, refineries, utilities (water/wastewater, electric) and related industrial sites are complex systems and structures with inspection and maintenance procedures required for optimal operation and regulatory compliance. As a specific example, consider just the bulk electric power system which is comprised of more than 200,000 miles of highvoltage transmission lines, thousands of generation plants and millions of digital controls. More than 1,800 entities own and operate portions of the grid system, with thousands more involved in the operation of distribution networks across North America. The interconnected and interdependent nature of the bulk power system requires a consistent and systematic application of risk mitigation across the entire grid system to be truly effective. Similar situations are found throughout automation where frequently an aging infrastructure is in place too. Consider, for example, the situation present in a refinery or chemical processing setting with the requirement for leak detection inspection of pipes, interconnects and systems stretching across the plant. The current practices and challenges relating just to this task - leak detection and repair (LDAR) – of detecting any fugitive emissions present and documenting all measurements thereby meeting air compliance regulations are typically “handled” by a small army of individuals with handheld or backpack-sized detectors who crawl through piping racks conducting measurements at each flange. Such work is performed in difficult conditions (temperature, humidity, physically challenging) with frequently a high level of employee turnover. Finaly, enter low cost sensors and mobile platforms – in other words unmanned aerial systems (UASs, or drones) with enhanced sensing capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible neural interfaces with integrated stiffening shank

A neural interface includes a first dielectric material having at least one first opening for a first electrical conducting material, a first electrical conducting material in the first opening, and at least one first interconnection trace electrical conducting material connected to the first electrical conducting material. A stiffening shank material is located adjacent the first dielectric material, the first electrical conducting material, and the first interconnection trace electrical conducting material.

36 MATERIALS SCIENCE↗

Nanoporous titanium niobium oxide and titanium tantalum oxide compositions and their use in anodes of lithium ion batteries

Nanoporous metal oxide framework compositions useful as anodic materials in a lithium ion battery, the composition comprising metal oxide nanocrystals interconnected in a nanoporous framework and having interconnected channels, wherein the metal in said metal oxide comprises titanium and at least one metal selected from niobium and tantalum, e.g., TiNb.sub.2-x Ta.sub.xO.sub.y (wherein x is a value from 0 to 2, and y is a value from 7 to 10) and Ti.sub.2Nb.sub.10-vTa.sub.vO.sub.w (wherein v is a value from 0 to 2, and w is a value from 27 to 29). A novel sol gel method is also described in which sol gel reactive precursors are combined with a templating agent under sol gel reaction conditions to produce a hybrid precursor, and the precursor calcined to form the anodic composition. The invention is also directed to lithium ion batteries in which the nanoporous framework material is incorporated in an anode of the battery.

25 ENERGY STORAGE↗

System and method for neural interface with modular active electronics

A modular, high density electrical system is disclosed which makes use of an interface component, which is well suited to being placed in contact with an anatomy of either a human or an animal, and which may be releasably coupled to an electronics module subsystem. The interface component has a plurality of electrically conductive interconnect pads that may be releasably secured by a member to a plurality of electrically conductive pads of the electronics module subsystem. The electronics module subsystem may have a substrate which supports both an electronics circuit and the interconnect pads.

Shah, Kedar G.↗

DC-connected Solar Plus Storage Modeling and Analysis for Behind-The-Meter Systems in the System Advisor Model: Preprint

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

Balanced charge-recycling repeater link

A balanced, charge-recycling repeater link is disclosed. The link includes a first set of segments operating in a first voltage domain and a second set of segments operating in a second voltage domain. The link is configured to transmit a first signal over at least one segment in the first set of segments and at least one other segment in the second set of segments. Each segment of the link includes at least one active circuit element configured to charge or discharge one or more corresponding interconnects within the link and a level shifter configured to shift the level of a signal on a last interconnect of the segment from the first voltage domain to the second voltage domain or the second voltage domain to the first voltage domain.

Wilson, John Michael↗

Balanced charge-recycling repeater link

A balanced, charge-recycling repeater link is disclosed. The link includes a first set of segments operating in a first voltage domain and a second set of segments operating in a second voltage domain. The link is configured to transmit a first signal over at least one segment in the first set of segments and at least one other segment in the second set of segments. Each segment of the link includes at least one active circuit element configured to charge or discharge one or more corresponding interconnects within the link and a level shifter configured to shift the level of a signal on a last interconnect of the segment from the first voltage domain to the second voltage domain or the second voltage domain to the first voltage domain.

Wilson, John Michael↗

DC-Connected Solar Plus Storage Modeling for Behind-the-Meter Systems in SAM

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

Support structure for solar module

A solar module (2) comprising; (a) an active portion (4) and (b) a support portion (6), wherein the support portion (8) includes a plurality of reinforcement ribs (20) in a series of interconnected or partially interconnected patterns. The solar module (2) may include an intermediate portion (6C) acting as a structural interface between the active portion (4) and the support portion (6). The intermediate portion (6C) may include one or more gate locations (10, 12). The plurality of reinforcement ribs (20) may extend at an angle along the support portion (6) so that an effective modulus of the support portion (6) along a width direction is substantially equal to an effective modulus of the support portion (6) along a length direction.

Keenihan, James R.↗

Concentrator-type photovoltaic (CPV) modules, receiver and sub-receivers and methods of forming same

CPV modules include a back plate having an array of 1 mm2 or smaller solar cells thereon. A backplane interconnect network is also provided on the back plate. This backplane interconnect network operates to electrically connect the array of solar cells together. A front plate, which is spaced-apart from the back plate, is provided. This front plate includes an array of primary lenses thereon that face the array of solar cells. The front plate can be configured to provide a greater than 1000× lens-to-cell light concentration to the array of solar cells. To achieve this 1000× lens-to-cell light concentration, the primary lenses can be configured as plano-convex lenses having a lens sag of less than about 4 mm. An array of secondary optical elements may also be provided, which extend between the array of primary lenses and the array of solar cells.

14 SOLAR ENERGY↗

Evaluating software defined networking solutions to reduce the digital attack surface of nuclear security systems

Most nuclear security systems used today were not designed for today’s threat environment. Systems that were intended to be stand alone are now interconnected. Devices that have a single purpose are built on multi-purpose platforms and communication protocols that, while effective, have no ability to authenticate authorized versus unauthorized commands. These attributes provide an attacker significant ability to affect the system, pivot throughout the interconnected networks, and remain undetected if he/she is able to compromise a single node. Software defined networking (SDN) has been used for years by information technology (IT) cloud service providers to quickly provision or remove servers or other systems to meet changing demand. The same concept has recently been applied to operational technology (OT) systems to enable very fast failover on critical systems that have stringent and deterministic (<5ms) transmit/receive times. By carefully engineering the communication flows through a network using preplanned routes and specific pathways it is possible to achieve deterministic and extremely reliable message delivery even when components fail. This engineering approach to network design has added security benefits including securing the networking control plane, eliminating network scanning and mapping, inhibiting ARP spoofing and host masquerading, eliminating unauthorized network pivoting and enabling greater situational awareness on the network. SDN in OT environments is new but early testing in electrical power and other critical infrastructure has shown it to be a very powerful tool for building reliable networks and reducing the digital attack surface of the network. The authors tested a software defined network switch on a simple physical protection system with components commonly found in nuclear security systems and found improved mitigations to denial of service attacks, lateral movement and network reconnaissance. The paper details the tests and their results.

Cyber security, Nuclear security, software defined↗

DIRECT LASER DEPOSITION OF POROUS STRUCTURES AND GRADIENT METAL-CERAMIC COMPOSITE COATINGS

Direct laser deposition is an additive manufacturing technique capable of producing complex geometries, bond different materials, repair broken parts, and add protective coating. In the present study it is used to make micro-porous scaffolds and apply protective vanadium and niobium carbide coatings. Micro-porous metal filters are a difficult thing to make but are required for many applications. In this study it was hypothesized that laser engineering net shaping (LENS) could be used to make porous Ti6Al4V scaffolds with an interconnected micro-porous structure. This proved to be true with cylinders made to have 15.9% porosity, and a pore size less than 100μm. These structures were made by only altering processing parameters, which yielded a scaffold with obstructed random pore interconnectivity. The scaffolds had a compressive strength of 645-556MPa and martensitic like α' grains. Another study was done to apply hard niobium and vanadium carbide surface coatings to stainless steel. The objective was to used LENS to deposit stainless steel coatings with added carbides to eventually make a gradient coating with increased protective qualities. Parts that have suffered material loss from abrasive wear or cavitation could have material added back as well as add a protective coating at the same time. Compositions ranging from 5% to 100% of the carbides were mixed with stainless steel. The coatings were then deposited on a stainless steel 304 substrate individually, as well as in a series to make a gradient structure. These coatings all increased hardness, wear resistance, and 100%VC significantly increased the materials resistance to damage from abrasive water. The carbides integrated into the SS304 matrix on the grain boundaries making a metal ceramic composite. These precipitates left residual stress in the structure which increased the hardness and wear resistance. The study proved that the addition of these carbides did increase the protective qualities and could make a gradient coating with properties tailored to the user’s preference.

13 HYDRO ENERGY↗

Impacts of High Levels of Distributed PV and Load Dynamics on Bulk Power Transient Stability: Preprint

The addition of large amounts of wind and solar generation to bulk power systems that are traditionally subject to operating constraints set by transient stability and frequency response limitations is the subject of considerable concern in the industry in all North American grids. The U.S. Western Interconnection is expected to experience substantial additional growth in both wind and solar generation. This generation will, to some extent, displace large central station thermal generation, both coal and gas-fired, which have traditionally helped maintain stability. A substantial fraction of the new photovoltaic (PV) solar generation will be deeply embedded in the distribution system and will be electrically in close proximity to customer loads. Several aspects of this renewable generation on transient stability and frequency response have been investigated and reported elsewhere in summaries of a study that included an investigation of the dynamic performance of the Western Interconnection with high penetrations of wind and solar generation. In this paper, modeling and the impact of distributed PV generation and dynamic loads are reported. The key finding is that the transient performance, particularly the fault ride-through behavior of embedded PV, is critical to system stability. Poor ride-through characteristics on distributed generation are shown in the study to collapse the entire grid. The dynamic behavior of the loads, aside from the embedded PV is also shown to be a critical element. The investigation reinforces the need for valid models and for thorough system planning studies.

14 SOLAR ENERGY↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System: Preprint

Frequency control from Photovoltaic (PV) plants has great potential to address the frequency response challenge of the power system with high renewable penetration. However, using model-based approaches to determine the optimal PV headroom reserve requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic one-day operation profile of the WECC system and demonstrates over 40% PV headroom saving compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Model-Free Primal-Dual Methods for Network Optimization with Application to Real-Time Optimal Power Flow: Preprint

This paper examines the problem of real-time optimization of networked systems and develops online algorithms that steer the system towards the optimal trajectory without explicit knowledge of the system model. The problem is modeled as a dynamic optimization problem with time-varying performance objectives and engineering constraints. The design of the algorithms leverages the online zero-order primal-dual projected-gradient method. In particular, the primal step that involves the gradient of the objective function (and hence requires networked systems model) is replaced by its zero-order approximation with two function evaluations using a deterministic perturbation signal. The evaluations are performed using the measurements of the system output, hence giving rise to a feedback interconnection, with the optimization algorithm serving as a feedback controller. The paper provides some insights on the stability and tracking properties of this interconnection. Finally, the paper applies this methodology to a real-time optimal power flow problem in power systems, and shows its efficacy on the IEEE 37-node distribution test feeder for reference power tracking and voltage regulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

OpenCGRA: An Open-Source Unified Framework for Modeling,Testing, and Evaluating CGRAs

Coarse-grained reconfigurable arrays (CGRAs),loosely defined as arrays of functional units (e.g, adder, sub-tractor, multiplier, divider, or larger multi-operation units, butsmaller than a general-purpose core) interconnected through aNetwork-on-Chip, provide higher flexibility than domain-specificASIC accelerators while offering increased hardware efficiencywith respect to fine-grained reconfigurable devices, such as FieldProgrammable Gate Arrays (FPGAs). The fast evolving fieldsof machine learning and edge computing, which are seeing acontinuous flow of novel algorithms and larger models, makeCGRAs ideal target architectures to allow domain specializationwithout loosing too much generality. They also generally offerquicker and more effective reconfigurability than FPGAs, po-tentially allowing adaptation during actual algorithm execution,and implement a dataflow programming paradigm that adaptswell to these emerging workloads. Designing and generating aCGRA, however, still requires to define the type and number ofthe specific functional units, implement their interconnect andthe network topology, and perform its simulation and validation,given a variety of workloads of interest.In this paper, we propose OpenCGRA, a Python-based unifiedframework that integrates generation, modeling, testing and eval-uation for CGRAs. OpenCGRA is the first open-source integratedframework able to support the full top-to-bottom design flow forspecializing and implementing CGRAs: modeling at different ab-straction levels (functional level, cycle level, register-transfer level),generation, simulation, testing at different granularities (unit test-ing, integration testing, property-based testing), and characteriza-tion (area, power, and timing). OpenCGRAs will be made availableon GitHub.

CGRA, synthesis↗