Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Investigation of Polyurethane and Fire-Retardant Foams as a Radiological Contamination Fixatives - 20202

Fixation of radiological contamination in decommissioning and deactivation can reduce worker risk, and mitigate potentially hazardous conditions; however, nearly every marketed contamination fixative has been found to be flammable, a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular void spaces or areas that are difficult to access and ensure full coverage. To this end, Savannah River National Laboratory (SRNL), in conjunction with Florida International University (FIU), have begun investigating the applicability of polyurethane based foaming materials, which will expand to fill a given asymmetric volume and provide fire retardancy to ensure no release of contamination in the event of a facility fire. Commercial foams undergo exothermic reactions resulting in gaseous release that subsequently causes the curing foam material to expand. Heat generation during curing can potentially compromise rubber parts of an enclosure, a significant concern in nuclear facilities. To mitigate large body heat generation, SRNL has also examined multiple layering of the material to ensure compatibility of the curing material with a previously cured body of the same material. Environmental studies were also completed in order to determine the influence on polyurethane based foams curing process. These studies showed that nearly half of the materials tested delaminated from a cured body of the same material, a property not discussed in commercially available documentation on the products. Of note was the compatibility of the foaming material with the substrate, depending on the type material that the foam was cured in/on, significant delamination could occur. Mechanical testing via tensile pull tester, dynamic mechanical analysis (DMA), and thermogravimetric analysis (TGA) was also performed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Temperature Oxidation Behavior of Wrought and Additive Manufactured Alloys in Direct-Fired Supercritical CO2 Power Cycle Environments

Materials selection is a key concern for corrosion resistance in elevated temperature and pressure direct-fired supercritical CO2 (sCO2) power cycles. The effect of elevated pressure on corrosion resistance can be critical, as impurities within the supercritical fluid such as H2O and O2 can have additional corrosion effects than found at ambient pressure conditions. Several wrought nickel-based commercial alloys (230, 263, 282, 617, 625, 740H) were exposed to direct-fired conditions (95CO2 – 4H2O – 1 O2) at 750 °C at both atmospheric pressure (0.1 MPa) and supercritical conditions (20 MPa) for over 2,000 h. Additionally, additive manufactured (AM) 282 produced by laser powder bed fusion (LPBF) were also included in the exposures. Supercritical conditions affected the oxidation behavior of several alloys. Most notably, water-vapor assisted Cr-oxide volatilization was observed at 750 °C supercritical conditions. Many alloys did not form sufficient protective Cr-oxide scales at supercritical conditions, leading to increased oxidation at elevated pressure. Differences in oxidation behavior were also observed for 282 AM samples compared to their wrought counterparts, with the differences also dependent on the LPBF build parameters and post-production treatments (heat treatment and surface finishing procedures). The AM samples formed Mo-rich carbides in the alloy beneath the oxide following sCO2 exposure, implying potentially higher levels of carbon uptake relative to the wrought

Carney, Casey↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗

GLOVEBOX WINDOWS, FIRE PROTECTION AND VOICES FROM THE PAST

'Study the past--what is past is prologue'. These words appear as the motto on a pair of statues at the National Archives Building in Washington DC. They are also the opening sentence in the preface of a document written in August of 1956 entitled 'A Summary of Accidents and Incidents Involving Radiation in Atomic Energy Activities--June 1945 thru December 1955'. This document, one of several written by D.F. Hayes of the Safety and Fire Protection Branch, Division of Organization and Personnel, U.S. Atomic Energy Commission in Washington DC, and many others are often forgotten even though they contain valuable glovebox fire protection lessons for us today.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assembly and Characterization of a Prototype Laser-Optical Firing System

The design, assembly and characterization of the latest generation of a small, ruggedized laser-optical firing system will be discussed. This work builds upon earlier results in an effort to continue the development of robust fiber-coupled laseroptical firing systems.[1][2] This newest prototype strives to improve on earlier designs, while continuing to utilize many of the environmentally proven opto-mechanical sub-assemblies.[2][3] One area of improvement involves the implementation of a second optical safing and arming component. Several additional design improvements were also incorporated to address shortcomings uncovered during environmental testing.[4][5] These tests and the subsequent failure analysis were performed at the laser sub-system level. Four identical prototypes were assembled and characterized. The performance of the units were evaluated by comparing a number of parameters including laser output energy, slope efficiency, beam divergence, spatial intensity profile, fiber injection and splitter-coupler transmission efficiency. Other factors evaluated were the ease of alignment, repeatability of the alignment process and the fabrication of the fiberoptical cables. The experimentally obtained results will be compared and contrasted to the performance of earlier prototypes.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Characterization of liquefied natural gas tanker steel from cryogenic to fire temperatures.

The increased demand for Liquefied Natural Gas (LNG) as a fuel source in the U.S. has prompted a study to improve our capability to predict cascading damage to LNG tankers from cryogenic spills and subsequent fire. To support this large modeling and simulation effort, a suite of experiments were conducted on two tanker steels, ABS Grade A steel and ABS Grade EH steel. A thorough and complete understanding of the mechanical behavior of the tanker steels was developed that was heretofore unavailable for the span of temperatures of interest encompassing cryogenic to fire temperatures. This was accomplished by conducting several types of experiments, including tension, notched tension and Charpy impact tests at fourteen temperatures over the range of -191 C to 800 C. Several custom fixtures and special techniques were developed for testing at the various temperatures. The experimental techniques developed and the resulting data will be presented, along with a complete description of the material behavior over the temperature span.

03 NATURAL GAS↗

Validation predictions of a 13 m/s cross-wind fire for Fuego and the University of Waterloo dataset.

Detailed herein are the results of a validation comparison. The experiment involved a 2 meter diameter liquid pool of Jet-A fuel in a 13 m/s crosswind. The scenario included a large cylindrical blocking object just down-stream of the fire. It also included seven smaller calorimeters and extensive instrumentation. The experiments were simulated with Fuego. The model included several conduction regions to model the response of the calorimeters, the floor, and the large cylindrical blocking object. A blind comparison was used to compare the simulation predictions with the experimental data. The more upstream data compared very well with the simulation predictions. The more downstream data did not compare very well with the simulation predictions. Further investigation suggests that features omitted from the original model contributed to the discrepancies. Observations are made with respect to the scenario that are aimed at helping an analyst approach a comparable problem in a way that may help improve the potential for quantitative accuracy.

54 ENVIRONMENTAL SCIENCES↗

Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opportunities for Energy, Water, and Waste Reduction at U.S. Forest Service Fire Camps

This report summarizes the results from energy efficiency, water efficiency, waste reduction and renewable energy site assessments conducted at fire camps located in the United States. A team led by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the assessments with U.S. Forest Service (USFS) personnel during the summers of 2016 and 2017 as part of ongoing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Combating Airplane Fires

This report provides a summary of the important steps to be taken in combating airplane fires.

FIRE PREVENTION↗

Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection

Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.

Fire Safety↗

Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection

Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.

Fire↗

NASA Wildland Fire Management Program

This short talk (less than 10 minutes) is to introduce the NASA Applied Science Wildland Fire Management program to a general audience.

NASA↗

NASA Wildland Fires

See attached presentation slides. This short talk (less than 10 minutes) is to introduce the NASA Applied Science Wildland Fire Management program to a general audience. Links to the NASA program homepage are shared.

NASA↗

Variation in Morphology and Kinetics of Granular Bainite with Welding Thermal Cycles in High-Nb Fire-Resistant Steel: Experiments and Theoretical Calculations

The microstructure and kinetics of granular bainite (GB) were investigated in novel fire-resistant steel containing high niobium and subjected to simulated welding thermal cycles. The dilatometric data were analyzed to determine the activation energy and Avrami exponents. It was observed that austenite transformed to GB over a wide range cooling rates of 0.5-100 K/s. Theoretical calculations indicated that Avrami exponent (n) decreased with increased transformed volume fraction (f{sub b}) and cooling rate. At a moderate cooling rate of 20-6 K/s, bainitic ferrite as sheaves formed from austenite and the corresponding Avrami exponent was 2 < n < 3. Martensite in martensite/austenite constituent formed with Avrami exponent n ~ 1. At the fastest cooling rate of 50 K/s, lath bainitic ferrite and film-like retained austenite (RA) were obtained with the corresponding Avrami exponent n ~ 1. At lower cooling of 1 and 0.5 K/s, plate-like bainitic ferrite and block-like microphase composed of lamellar RA and ferrite were obtained with Avrami exponent n > 3. The local activation energy for austenite transformation to bainitic ferrite decreased from ~ 198 to ~ 182 kJ/mol with increasing f{sub b} from 0.05 to 0.95, while the local activation energy for austenite transformation to martensite decreased from ~ 80 to ~ 71 kJ/mol with increasing f{sub b} from 0.05 to 0.95.

36 MATERIALS SCIENCE↗

Cost-effectiveness Analysis on Measures to Improve China's Coal-fired Industrial Boiler

Tackling coal-burning industrial boiler is becoming one of the key programs to solve the environmental problem in China. Assessing the economics of various options to address coal-fired boiler is essential to identify cost-effective solutions. This paper discusses our work in conducting a cost-effectiveness analysis on various types of improvement measures ranging from energy efficiency retrofits to switch from coal to other fuels in China. Sensitivity analysis was also performed in order to understand the impacts of some economic factors such as discount rate and energy price on the economics of boiler improvement options. The results show that nine out of 14 solutions are cost-effective, and a lower discount rate and higher energy price will result in more energy efficiency measures being cost-effective. Both monetary and non-monetary barriers to energy-efficiency improvement are discussed and policies to tackle these barriers are recommended. Our research aims at providing a methodology to assess cost-effective solutions to boiler problems.

01 COAL, LIGNITE, AND PEAT↗