Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FAILURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Unlocking Failure Mechanisms and Improvement of Practical Li–S Pouch Cells through In Operando Pressure Study

For Lithium-sulfur (Li-S) battery commercialization, the study at a pouch cell level is essential, as some problems ignored or deemed minimal at the smaller level could have a greater effect on the performance of the larger pouch cell. Herein, the failure mechanisms of Li-S pouch cells are deeply investigated via in operando pressure analysis. It is found that highly porous structures of cathodes/separators and slow electrolyte diffusion through cathodes/separators can both lead to poor initial wetting. Additionally, Li-metal anode dominates the thickness variation of the whole pouch cell, which is verified by in situ measured pressure variation. Consequently, a real-time approach that combined normalized pressure with dP/dV analysis is proposed and validated to diagnose the morphology evolution of Li-metal anode. Moreover, applied pressure and porosity/tortuosity ratio of the cathode are both identified as independent factors that influence anode performance. In addition to stabilizing anodes, high pressure is proven to improve the cathode connectivity and avoid cathode cracking over cycling, which improves the possibility of developing cathodes with high sulfur mass loading. Here, this work provides insights into Li-S pouch cell design (e.g., cathode and separator) and highlights pathways to improve cell capacity and cycling performance with applied and monitored pressure.

25 ENERGY STORAGE↗

Algorithms and Experience with Prediction of Technical Operating Failures in Nuclear Power Plant Equipment

The development of algorithms for the prediction of technological operating failure of nuclear power plant equipment based on stochastic extrapolation of the values of technical parameters is discussed. The algorithms are tested on real archived data on the operation of the oil circulation system of the main circulating pumps in a power generating unit at a nuclear power plant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methods to Observe Tribological Failures in Self-Mated Steel Contacts

Scuffing, a type of wear found in highly stressed or poorly lubricated contacts, is characterized by a rapid increase in friction and severe plastic deformation of the near-surface material. Scuffing has proven difficult to study because it initiates unpredictably, progresses rapidly, and typically develops within an inaccessible contact interface. Although there have been successful in-situ studies of scuffing in real-time, the transparent counter body needed for these studies changes the interactions between the surfaces and the lubricant, which affects the scuffing process in unknown ways. This paper describes the development of X-ray-compatible tribometry to study the scuffing of self-mated steels in-situ and in real-time. The method uses a crossed cylinders configuration with a thin (500 μm thick) stationary component and a small (≈200 μm) contact width to maximize X-ray interactions with atoms within the stress field generated by the contact. The resulting instrument and method are used to benchmark the scuffing response of self-mated 52,100 steel under tribologically challenging ‘oil-off’ lubrication conditions. The results demonstrate reliable scuffing in this configuration despite the relatively small contact areas and loads used. Following scuffing, gross plastic deformation was observed on both surfaces along with significant subsurface grain refinement and flow only on the stationary surface, which experienced constant contact. Interestingly, high friction initiated at specific locations of the migratory surface, which experienced intermittent contact, and then propagated across the track over time, suggesting that local conditions of the migratory surface dominated friction leading into the failure event.

36 MATERIALS SCIENCE↗

Processing Parameter Control of Lifetime-Limiting Failure Mechanisms in Al-Si Cast Alloys at Room and Elevated Temperatures

Aluminum-silicon cast alloys widely used throughout the transportation sector, A356, 319, and A390, have been studied with respect to chemical compositions and processing parameters that control the resultant mechanical behavior. First, the development of strengthening mechanisms is discussed in terms of the role that alloying elements, solidification behavior, and thermal treatments play. Based on this understanding, an extensive matrix of material conditions was developed and characterized in order to provide practical guidelines for alloy development. In order to provide an understanding of lifetime-limiting failure mechanisms, fatigue crack growth and hot compressive dwell behaviors were further investigated. Fatigue crack growth tests were conducted for all alloys at R = 0.1 and room temperature, and creep–fatigue of 319 was studied at R = − 1.5 and 250 °C. The role of processing parameters in controlling the mechanical properties is identified and discussed, and recommendations for optimized design are made.

36 MATERIALS SCIENCE↗

Study of Wave-Absorbing Coating Failure by Electrochemical Measurements

The absorption properties of wave-absorbing coatings can easily fail; therefore, a layer of corrosion-resistant topcoat is often added to the surface to increase the service life of the absorbing coating. In this study, we compare the changes in samples without or with a topcoat, namely fluorinated polyurethane, at 25 °C with a NaCl solution and at 35 °C with a neutral salt spray. Morphological characterization and composition analysis show that the topcoat can indeed greatly improve the corrosion resistance of the samples, but the absorption of the coatings still decreases in a short time. The reasons for this are indicated by electrochemical impedance spectroscopy. For the samples without a topcoat, the corrosion of the wave-absorbing coatings results in the failure of wave absorption. For the samples with a topcoat, it is likely that the state of the interface between the topcoat and absorbing coatings leads to the decline of the resistance of the wave-absorbing coatings, causing them to fail quickly.

36 MATERIALS SCIENCE↗

Failure Analysis of Pinch Weld Electrodes

We present that Savannah River Site uses brazed copper/tungsten electrodes for a specialized weld referred to as a pinch weld. An alternative method to produce the pinch weld electrodes was sought to improve quality and to reduce the manufacturing steps. Backcasting of pinch weld electrodes was selected as such a process. During preliminary testing, deformation of the electrodes was observed. A failure analysis assessment was conducted and the strength of the electrodes was found to be significantly less than required to enable welding of the tubes. This assessment includes compression testing metallographic analysis. The pinch weld electrodes fabricated by backcasting do not meet the requirements with respect to strength. Additionally, a minimum strength requirement for conventionally prepared electrodes is recommended.

36 MATERIALS SCIENCE↗

Use of Cardiac Imaging to Evaluate Cardiac Function and Pulmonary Hemodynamics in Patients with Heart Failure

Purpose of Review: Noninvasive hemodynamic assessments in patients with heart failure (HF) are essential for appropriate diagnosis and establishment of the best treatment strategies. Recently, the impact of pulmonary circulation and right ventricular function on prognosis in HF patients has drawn increasing attention. In this article, we explore the usefulness of cardiac imaging for hemodynamic assessments, mainly focusing on echocardiographic evaluation. Recent Findings: The reliability of Doppler echocardiography as a noninvasive alternative to Swan-Ganz catheterization has been well investigated with higher than 80% accuracy for estimating pulmonary artery pressure. Strain measurement and three-dimensional echocardiography are useful for evaluating right ventricular function together with pulmonary circulation. The accuracy of analyzing left and right ventricular functions by cardiac computed tomography and cardiac magnetic resonate imaging has also been established. These modalities can provide myocardial tissue information and allow calculation of the extracellular volume fraction as well. Summary: According to the rapid improvement of technologies, cardiac imaging has become an essential tool for hemodynamic evaluation in HF management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sex affects myocardial blood flow and fatty acid substrate metabolism in humans with nonischemic heart failure

Background: In animal models of heart failure (HF), myocardial metabolism shifts from high-energy fatty acid (FA) metabolism toward glucose. However, FA (vs glucose) metabolism generates more ATP/mole; thus, FA metabolism may be especially advantageous in HF. Sex modulates myocardial blood flow (MBF) and substrate metabolism in normal humans. Whether sex affects MBF and metabolism in patients with HF is unknown. Methods and Results: We studied 19 well-matched men and women with nonischemic HF (EF ≤ 35%). MBF and myocardial substrate metabolism were quantified using positron emission tomography. Women had higher MBF (mL/g/minute), FA uptake (mL/g/minute), and FA utilization (nmol/g/minute) (P < 0.005, P < 0.005, P < 0.05, respectively) and trended toward having higher FA oxidation than men (P = 0.09). These findings were independent of age, obesity, and insulin resistance. There were no sex-related differences in fasting myocardial glucose uptake or metabolism. Higher MBF was related to improved event-free survival (HR 0.31, P = 0.02). Conclusions: In nonischemic HF, women have higher MBF and FA uptake and metabolism than men, irrespective of age, obesity, or insulin resistance. Moreover, higher MBF portends a better prognosis. These sex-related differences should be taken into account in the development and targeting of novel agents aimed at modulating MBF and metabolism in HF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of sudden cardiac death in patients with chronic heart failure by regional washout rate in cardiac MIBG SPECT imaging

Background: The sympathetic nervous system provides an important trigger for major arrhythmic events through regional heterogeneity of sympathetic activity, which could be evaluated by SPECT imaging as the regional MIBG washout rate (WR). There is little information available on the prognostic value of regional WR in SPECT imaging for the prediction of sudden cardiac death (SCD) in patients with chronic heart failure (CHF). Methods: We studied 73 CHF outpatients with LVEF < 40%. At study entry, the regional WR was measured in 17 segments on the polar map. We defined abnormal regional WR as both the regional WR range (maximum − minimum regional WR) and maximum regional WR > mean value + 2SD obtained in 15 normal controls. Results: During a mean follow-up of 7.5 ± 4.1 years, 15 of 73 patients had SCD. The abnormal regional WR and abnormal global WR on planar images were significantly and independently associated with SCD. Patients with both the abnormal regional WR and global WR had a significantly higher risk of SCD than those with none of these criteria. Conclusions: The analysis of regional MIBG WR on SPECT imaging provides additional prognostic value to global WR on planar images for SCD prediction in CHF patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure

Aim: The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF). Methods: Fifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting {sup 99m}Tc-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and {sup 18}F-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually. Results: There was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT. Conclusion: CZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of liraglutide on myocardial glucose uptake and blood flow in stable chronic heart failure patients: A double-blind, randomized, placebo-controlled LIVE sub-study

Background: The glucagon-like peptide-1 analog liraglutide increases heart rate and may be associated with more cardiac events in chronic heart failure (CHF) patients. We studied whether this could be ascribed to effects on myocardial glucose uptake (MGU), myocardial blood flow (MBF) and MBF reserve (MFR). Methods and Results: CHF patients with left ventricular ejection fraction ≤45% and without type 2 diabetes were randomized to liraglutide (N = 18) 1.8 mg once daily or placebo (N = 18) for 24 weeks in a double-blinded design. Changes in MGU during an oral glucose tolerance test (OGTT) and changes in MBF and MFR from baseline to follow-up were measured quantitatively by {sup 18}F-FDG and {sup 15}O-H{sub 2}O positron emission tomography. Compared with placebo, liraglutide reduced weight (P = 0.03), HbA1c (P = 0.03) and the 2-hour glucose value during the OGTT (P = 0.004). Despite this, changes in MGU (P = 0.98), MBF (P = 0.76) and MFR (P = 0.89) from baseline to follow-up did not differ between groups. Furthermore, there was no association between the level of insulin resistance at baseline and changes in MGU in patients treated with liraglutide. Conclusion: Liraglutide did not affect MGU, MBF, or MFR in non-diabetic CHF patients. Any potential increase in cardiac events in these patients seems not to involve changes in MGU, MBF, or MFR. Trial Registration: Trial registry: http://www.ClinicalTrials.org . Identifier: NCT01472640. Url: https://clinicaltrials.gov/ct2/show/NCT01472640?term=NCT01472640&rank=1.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship of left ventricular global longitudinal strain with cardiac autonomic denervation as assessed by {sup 123}I-mIBG scintigraphy in patients with heart failure with reduced ejection fraction submitted to cardiac resynchronization therapy

Background: Heart failure (HF) is associated with cardiac autonomic denervation (AD), which can be non-invasively assessed by {sup 123}I-metaiodobenzylguanidine ({sup 123}I-mIBG) scintigraphy and has prognostic implications. We aimed to study the relationship between myocardial contractility assessed by global longitudinal strain (GLS) and AD assessed by {sup 123}I-mIBG scintigraphy in advanced HF. Methods/Results: BETTER-HF is a prospective randomized clinical trial including HF patients (pts) submitted to cardiac resynchronization therapy (CRT) who are submitted to a clinical, echocardiographic, and scintigraphic assessment before and 6 months after CRT. 81 pts were included. An echocardiographic response (absolute increase in left ventricular ejection fraction ≥ 10%) was observed in 73.7% of pts. A higher baseline late heart-to-mediastinum ratio (HMR) was associated with a better echocardiographic response. There was a significant association between late HMR and GLS at baseline and 6 months. At baseline, GLS had an AUC of 0.715 for discrimination for a late HMR < 1.6. A GLS cut-off of − 9% maximized the likelihood of correctly classifying a pt as having severe AD (HMR < 1.6). Conclusion: Myocardial contractility as assessed by GLS is moderately correlated with AD as assessed by {sup 123}I-mIBG scintigraphy and has a good discrimination for the identification of severe cardiac denervation. GLS may allow for a more readily accessible estimation of the degree of AD in advanced HF pts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of cardiac {sup 123}I-mIBG imaging in predicting arrhythmic events in stable chronic heart failure patients with an ICD

Background: Despite therapeutic improvement, the prognosis of chronic heart failure (CHF) remains unfavorable partly due to arrhythmia and sudden cardiac death (SCD). This prospective study evaluated myocardial {sup 123}I-meta-iodobenzylguanidine ({sup 123}I-mIBG) scintigraphy as a predictor of arrhythmic events (AE) in CHF patients. Methods: 170 CHF patients referred for implantable cardioverter-defibrillator (ICD) implantation for both primary and secondary prevention were enrolled. All patients underwent planar and SPECT imaging. Early and late heart-to-mediastinum (H/M) ratio, {sup 123}I-mIBG washout (WO), early and late summed SPECT scores were calculated The primary endpoint was an AE: sustained ventricular tachycardia, resuscitated cardiac arrest, appropriate ICD therapy or SCD. The secondary endpoint was appropriate ICD therapy. Results: During a median follow-up of 23.3 months, 69 patients experienced an AE. Early summed score (ESS) was the only independent predictor of AE [HR 1.023 (1.003-1.043)]. Focussing on only patients with an ICD for primary prevention, ESS was the only independent predictor of AE [HR 1.028 (1.007-1.050)]. {sup 123}I-mIBG-derived parameters failed to be independent predictors of appropriate ICD therapy. However there was a “bell-shaped” relation between {sup 123}I-mIBG scintigraphy-derived parameters and AE and appropriate ICD therapy, i.e., those with intermediate {sup 123}I-mIBG abnormalities tended to be at higher risk of events. Conclusion: Although SPECT {sup 123}I-mIBG scintigraphy was associated with AE in CHF patients with ICD implantation for primary and secondary prevention, no association was found between {sup 123}I-mIBG scintigraphy-derived parameters and appropriate ICD therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic deformation and failure of ultrafine-grained titanium

Dynamic deformation and shear localization of ultrafine-grained (~120 nm) pure titanium are examined. The strain hardening can be considered as having two regimes: below and above a strain ~0.04; at this point there is a drastic decrease in the slope. The strain-rate sensitivity of ultrafine-grained titanium is found to be approximately the same as its coarse grained counterpart. Based on experimentally determined parameters, the Zerilli-Armstrong equation is modified to describe the mechanical response of the ultrafine-grained titanium over the strain rate range 10 -5 to 10 3 s -1 . Adiabatic shear banding is examined in a forced shear configuration where large strain is imposed in a narrow region. The microstructure inside the adiabatic shear band consists of a mixture of elongated grains and equiaxed nanograins (~40 nm) that are significantly smaller than the initial grains (~120 nm). The formation of equiaxed nanograins is modeled through a mechanism of rotational dynamic recrystallization. This further reduction in grain size from the one generated by ECAP is interpreted in terms of the Zener-Hollomon parameter for quasistatic and dynamic deformation. The adiabatic shear band eventually fractures by a combination of brittle and ductile failure.

36 MATERIALS SCIENCE↗

Farnesoid-X-receptor expression in monocrotaline-induced pulmonary arterial hypertension and right heart failure

Objective: The farnesoid-X-receptor (FXR) is a metabolic nuclear receptor superfamily member that is highly expressed in enterohepatic tissue and is also expressed in the cardiovascular system. Multiple nuclear receptors, including FXR, play a pivotal role in cardiovascular disease (CVD). Pulmonary arterial hypertension (PAH) is an untreatable cardiovascular system disease that leads to right heart failure (RHF). However, the potential physiological/pathological roles of FXR in PAH and RHF are unknown. We therefore compared FXR expression in the cardiovascular system in PAH, RHF and a control. Methods and results: Hemodynamic parameters and morphology were assessed in blank solution-exposed control, monocrotaline (MCT)-exposed PAH (4 weeks) and RHF (7 weeks) Sprague–Dawley rats. Real-time reverse transcription polymerase chain reaction (real-time RT-PCR), Western blot (WB), immunohistochemistry (IHC) analysis and immunofluorescence (IF) analysis were performed to assess FXR levels in the lung and heart tissues of MCT-induced PAH and RHF rats. In normal rats, low FXR levels were detected in the heart, and nearly no FXR was expressed in rat lungs. However, FXR expression was significantly elevated in PAH and RHF rat lungs but reduced in PAH and RHF rat right ventricular (RV) tissues. FXR expression was reduced only in RHF rat left ventricular (LV) tissues. Conclusions: The differential expression of FXR in MCT-induced PAH lungs and heart tissues in parallel with PAH pathophysiological processes suggests that FXR contributes to PAH. - Highlights: • FXR was expressed in rat lung and heart tissues. • FXR expression increased sharply in the lung tissues of PAH and RHF rats. • FXR expression was reduced in PAH and RHF rat RV tissue. • FXR expression was unaltered in PAH LV but reduced in RHF rat LV tissue. • FXR expression was prominent in the neovascularization region.

60 APPLIED LIFE SCIENCES↗

Effect of electrical field on TSA failure of cement-based materials

The impact of electrical field on the sulfate attack of cement-based materials at low temperatures was studied to rapidly detect Thaumasite Sulfate Attack (TSA) in the laboratory and in future engineering. Sulfate attack of cement paste with 30 wt% replacement of CaCO{sub 3} powder soaked in Na{sub 2}SO{sub 4} solution, MgSO{sub 4} solution, or CaSO{sub 4} solution was measured under the condition of 5 ± 2 °C when an electrical field was applied. Appearance changes and compressive strength of the samples were tested to evaluate the corrosion degree. Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR) and Raman Spectroscopic measurements were applied to study the microstructure of the corrosion product. The test results indicate that sample damage was obvious, compression strength declined rapidly, and ettringite and/or thaumasite were found in the corrosion product after applying the electrical field for 90 days. A muddy product with TSA characteristics was formed, and thaumasite composition was found in the corrosion product after applying the electrical field for 120 days when MgSO{sub 4} solution was used as the corrosion medium. It is confirmed that an electrical field can accelerate TSA failure in cement-based materials.

36 MATERIALS SCIENCE↗

Hydrate failure in ITZ governs concrete strength: A micro-to-macro validated engineering mechanics model

Ever since the early days of Féret (1892) and Abrams (1919), concrete research has targeted at relating concrete composition to uniaxial compressive strength. While these activities were mainly characterized by empirical fitting functions, we here take a more fundamental approach based on continuum micromechanics. The loading applied at the concrete level, is first concentrated (''downscaled'') to maximum stresses related to cement paste volumes which are directly adjacent to the aggregates, i.e. to the interfacial transition zones (ITZ). These maximum stresses are further ''downscaled'' to the micron-sized hydrates, in terms of higher-order stress averages. The latter enter a Drucker-Prager failure criterion with material constants derived from nanoindentation tests. The model is successfully validated across the hydrate-to-concrete scales. Strength magnitude is governed by ITZ stress concentrations, and the water-to-cement ratio is its dominant mixture design parameter.

36 MATERIALS SCIENCE↗

Critical review of the Mogi failure criterion based on true-triaxial laboratory data analysis and theoretical considerations

The influence of the intermediate principal stress, σ 2 , is disregarded when rock strength is analyzed using the Mohr-Coulomb or Hoek-Brown criteria. Several polyaxial strength criteria have been proposed to account for the influence of σ 2 . One of the methods that received considerable attention is the Mogi criterion. The criterion modifies the Nadai or Drucker-Prager approaches by exchanging the normal octahedral stress with what is introduced as the mean effective stress, σ m,2 . This change is based on experimental evidence that the influence of the intermediate principal stress on strength is less pronounced than the influence of the minimum principal stress. However, the Mogi criterion was derived somewhat empirically and consequently it is essential to analyze its potential theoretical deficiencies. In the current note, we analyzed the Mogi failure criterion, describing its characteristics in both τ oct –σ m,2 and σ 1 -σ 2 spaces. We investigated the relation between Mohr-Coulomb and Mogi criteria, which marks the basis for the commonly used Mogi-Coulomb approach. Here, we compared the performance of the Mogi criterion against available polyaxial strength data using three fitting approaches: Mogi-Coulomb based on triaxial compression results only, linear Mogi based on all polyaxial strength results, and power law Mogi also based on all data. The analysis reveals several serious deficiencies of the Mogi approach which all suggest that the Mogi criterion cannot properly represent the σ 2 dependence of rock strength in many cases.

58 GEOSCIENCES↗