Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Why diamond dimensions and electrode geometry are crucial for small photon beam dosimetry

Recent use of very small photon beams (down to 4 mm) in stereotactic radiotherapy requires new detectors to accurately determine the delivered dose. Diamond detectors have been presented in the literature as an attractive candidate for this application, due to their small detection volume and the diamond atomic number (Z = 6) which is close to water effective atomic number (Zeff ∼ 7.42). However, diamond exhibits a density 3.51 times greater than that of water and recent studies using Monte Carlo simulations have demonstrated the drawback of a high-density detector on small beam output factors. The current study focuses on geometrical parameters of diamond detector, namely, the diamond dimensions and the electrode geometry, in order to solve the dosimetric issues still observed in small photon beams with diamond detectors. To give better insights to these open questions, we have used both computational method and experimental analysis. This study highlighted that reducing diamond dimensions is crucial for small beam output factor measurements and to limit the influence of its high density. Furthermore, electrodes covering the whole diamond surface were essential for a dose rate independence of the diamond detector. The optimal dosimeter derived from this work presented small diamond dimensions of approximately 1 × 1 × 0.15 mm{sup 3}, with diamond-like-carbon electrodes covering the whole diamond surface. A dose rate independence of this diamond detector (better than 0.5% over a wide range of dose rates available on a stereotactic dedicated facility) was obtained due to the electrode geometry. Concerning the output factor measurements, a good agreement (better than 1.1%) was observed between this carbon material detector and two types of passive dosimeters (LiF microcubes and EBT2 radiochromic films) for all beam sizes except the smallest field of 0.6 × 0.6 cm{sup 2} with a deviation of 2.6%. This new study showed the high performance of this diamond detector in small photon beams, in comparison with various commercially available passive and active dosimeters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-E-17A-06: Organ Dose in Abdomen-Pelvis CT: Does TG 111 Equilibrium Dose Concept Better Accounts for KVp Dependence Than Conventional CTDI?

Purpose: In CT imaging, a desirable quality assurance (QA) dose quantity should account for the dose variability across scan parameters and scanner models. Recently, AAPM TG 111 proposed to use equilibrium dose-pitch product, in place of CT dose index (CTDI100), for scan modes involving table translation. The purpose of this work is to investigate whether this new concept better accounts for the kVp dependence of organ dose than the conventional CTDI concept. Methods: The adult reference female extended cardiac-torso (XCAT) phantom was used for this study. A Monte Carlo program developed and validated for a 128-slice CT system (Definition Flash, Siemens Healthcare) was used to simulate organ dose for abdomenpelvis scans at five tube voltages (70, 80, 100, 120, 140 kVp) with a pitch of 0.8 and a detector configuration of 2x64x0.6 mm. The same Monte Carlo program was used to simulate CTDI100 and equilibrium dose-pitch product. For both metrics, the central and peripheral values were used together with helical pitch to calculate a volume-weighted average, i.e., CTDIvol and (Deq)vol, respectively. Results: While other scan parameters were kept constant, organ dose depended strongly on kVp; the coefficient of variation (COV) across the five kVp values ranged between 70–75% for liver, spleen, stomach, pancreas, kidneys, colon, small intestine, bladder, and ovaries, all of which were inside the primary radiation beam. One-way analysis of variance (ANOVA) for the effect of kVp was highly significant (p=3e−30). When organ dose was normalized by CTDIvol, the COV across the five kVp values reduced to 7–16%. The effect of kVp was still highly significant (p=4e−4). When organ dose was normalized by (Deq)vol, the COV further reduced to 4−12%. The effect of kVp was borderline significant (p=0.04). Conclusion: In abdomen-pelvis CT, TG 111 equilibrium dose concept better accounts for kVp dependence than the conventional CTDI. This work is supported by a faculty startup fund from the Cleveland State University.

60 APPLIED LIFE SCIENCES↗

The Simons Observatory: modeling optical systematics in the Large Aperture Telescope

We present geometrical and physical optics simulation results for the Simons Observatory Large Aperture Telescope. This work was developed as part of the general design process for the telescope, allowing us to evaluate the impact of various design choices on performance metrics and potential systematic effects. The primary goal of the simulations was to evaluate the final design of the reflectors and the cold optics that are now being built. We describe nonsequential ray tracing used to inform the design of the cold optics, including absorbers internal to each optics tube. We discuss ray tracing simulations of the telescope structure that allow us to determine geometries that minimize detector loading and mitigate spurious near-field effects that have not been resolved by the internal baffling. We also describe physical optics simulations, performed over a range of frequencies and field locations, that produce estimates of monochromatic far-field beam patterns, which in turn are used to gauge general optical performance. Finally, we describe simulations that shed light on beam sidelobes from panel gap diffraction.

Gudmundsson, Jon E. (ORCID:0000000317600355)↗

The Simons Observatory: Modeling Optical Systematics in the Large Aperture Telescope

We present geometrical and physical optics simulation results for the Simons Observatory Large Aperture Telescope. This work was developed as part of the general design process for the telescope; allowing us to evaluate the impact of various design choices on performance metrics and potential systematic effects. The primary goal of the simulations was to evaluate the final design of the reflectors and the cold optics which are now being built. We describe non-sequential ray tracing used to inform the design of the cold optics, including absorbers internal to each optics tube. We discuss ray tracing simulations of the telescope structure that allow us to determine geometries that minimize detector loading and mitigate spurious near-field effects that have not been resolved by the internal baffling. We also describe physical optics simulations, performed over a range of frequencies and field locations, that produce estimates of monochromatic far field beam patterns which in turn are used to gauge general optical performance. Finally, we describe simulations that shed light on beam sidelobes from panel gap diffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power distribution estimation method for SMR using ex-core detectors: experimental demonstration by plural control rod patterns at KUCA

The power distribution estimation method based on the ex-core detectors, or PHOEBE, was demonstrated at Kyoto University Critical Assembly, KUCA. Generally, core monitoring systems use in-core neutron detectors. Since inside the core is a harsh environment, the maintainability and reliability of the detectors are deteriorated. On the other hand, the environment outside the core is milder: core monitoring by the ex-core detectors improves the maintainability and reliability especially for small modular reactors and micro-reactors. However, neutron information from the inner region of the core is lost at the ex-core detectors. To recover the information, the authors proposed to utilize the power correlation between the fuel regions. PHOEBE concept was demonstrated at KUCA with distorted power distributions simulated by control rod patterns. The relative power distribution estimated by PHOEBE agreed with that calculated by Monte Carlo simulation code MVP. PHOEBE approximately reproduced the trend of the distorted power distributions calculated by MVP code. By contrast, the case of without power correlation between fuel regions produced significant different power distributions. Therefore, the advantage of considering the power correlation between fuel regions was also demonstrated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of Nuclear Resonance Fluorescence for Spent Nuclear Fuel Assay

In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of gamma rays with specific energies that are characteristic of the emitting isotope. NRF promises the unique capability of directly quantifying a specific isotope without the need for unfolding the combined responses of several fissile isotopes as is required in other measurement techniques. We have analyzed the potential of NRF as a non-destructive analysis technique for quantitative measurements of Pu isotopes in spent nuclear fuel (SNF). Given the low concentrations of 239Pu in SNF and its small integrated NRF cross sections, the main challenge in achieving precise and accurate measurements lies in accruing sufficient counting statistics in a reasonable measurement time. Using analytical modeling, and simulations with the radiation transport code MCNPX that has been experimentally tested recently, the backscatter and transmission methods were quantitatively studied for differing photon sources and radiation detector types. Resonant photon count rates and measurement times were estimated for a range of photon source and detection parameters, which were used to determine photon source and gamma-ray detector requirements. The results indicate that systems based on a bremsstrahlung source and present detector technology are not practical for high-precision measurements of 239Pu in SNF. Measurements that achieve the desired uncertainties within hour-long measurements will either require stronger resonances, which may be expressed by other Pu isotopes, or require quasi-monoenergetic photon sources with intensities that are approximately two orders of magnitude higher than those currently being designed or proposed.This work is part of a larger effort sponsored by the Next Generation Safeguards Initiative to develop an integrated instrument, comprised of individual NDA techniques with complementary features, that is fully capable of determining Pu mass in spent fuel assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-I-72: Evaluation of the Ancillary Lead Shielding for Optimizing Radiation Protection in the Interventional Radiology Department

Purpose: The rising complexity of interventional fluoroscopic procedures has resulted in an increase of occupational radiation exposures in the interventional radiology (IR) department. This study assessed the impact of ancillary shielding on optimizing radiation protection for the IR staff. Methods: Scattered radiation measurements were performed in two IR suites equipped with Axiom Artis systems (Siemens Healthcare, Erlangen, Germany) installed in 2006 and 2010. Both rooms had suspended ceiling-mounted lead-acrylic shields of 75×60 cm (Mavig, Munich, Germany) with lead equivalency of 0.5 mm, and under-table drapes of 70×116 cm and 65×70 cm in the newer and the older room respectively. The larger skirt can be wrapped around the table’s corner and in addition the newer suite had two upper shields of 25×55 cm and 25×35 cm. The patient was simulated by 30 cm of acrylic, air kerma rate (AKR) was measured with the 180cc ionization chamber (AccuPro Radcal Corporation, Monrovia, CA, USA) at different positions. The ancillary shields, x-ray tube, image detector, and table height were adjusted by the IR radiologist to simulate various clinical setups. The same exposure parameters were used for all acquisitions. AKR measurements were made at different positions relative to the operator. Results: The AKR measurements demonstrated 91–99% x-ray attenuation by the drapes in both suites. The smaller size of the under-table skirt and absence of the side-drapes in the older room resulted in a 20–50 fold increase of scattered radiation to the operator. The mobile suspended lead-acrylic shield reduced AKR by 90–94% measured at 150–170 cm height. The recommendations were made to replace the smaller under-table skirt and to use the ceiling-mounted shields for all IR procedures. Conclusion: The ancillary shielding may significantly affect radiation exposure to the IR staff. The use of suspended ceiling-mounted shields is especially important for reduction of interventional radiologists’ cranial radiation.

60 APPLIED LIFE SCIENCES↗

Pneumatic System for the Neutron Generator Facility at SRNL

A neutron generator system equipped with a pneumatic sample transfer system, enables scientists to perform neutron activation analysis with increased efficiency and accuracy. The samples are placed in sealed containers called 'rabbits' and are passed through the system. Once sealed in the rabbit, the samples are loaded into the tubes via a hopper mechanism. The sample is launched into the generator with compressed air and captures neutrons, causing the sample to become radioactive. Next, the sample is sent to a detector, where the samples are counted for a set length of time on a Ge detector. Once the detection is completed, the sample is then sent to the trash. The system utilizes an interface to select which generator valve and detector location to send the sample too. This project is supports the future development of the neutron generator in the F wing of 773-A. A program is used to automate the passing of the rabbit through the system. The user is able to select the generator valve and detector to be utilized in the testing of the sample. Using the 'Add Rabbit' button the user can add as many sample rabbits to rabbit editor tab. Characteristics are then entered into the fields for each rabbit. The Pre-Det Cooldown and Post-Det Cooldown are intervals used to space out the time before the rabbit is sent into and out of the detector. After all characteristics are entered, the 'Submit to Hopper' button is selected thus preparing the program to run the rabbits in the inserted order. Small setup of the system using the available parts. Simulates the movement of the rabbit from the generator to the detector. Small valves are located before each manifold. To transport the rabbit from one side to the other, the valve of the sending side must be open and the receiving side must be closed. The manifold and valve in direct line with the compressor would extend to the hopper. Once the hopper is loaded, the valve would be open to send the rabbit to generator. Additional manifolds and other mechanical parts are necessary to complete the system design. To complete the construction of the system additional parts, such as the mechanical parts for the switching mechanism and the solenoid valves, are necessary. Further, to complete the automatization of the system, an Arduino is required to communicate with the valves and adjust the linear servos appropriately so that the rabbits are sent to the selected generator location and detector. This work is aimed to be completed in the next fiscal year.

42 ENGINEERING↗

Optimization of the BDX experiment for Light Dark Matter searches at JLab

The Light Dark Matter (LDM) hypothesis postulates the existence of a new class of sub GeV particles, neutral under Standard Model (SM) interactions. In its simplest form, LDM consists of particles ¿ with masses below 1 GeV/c2, interacting with SM particles via a new force mediated by a light, spin-1 boson A0, commonly referred to as “Dark Photon”. This framework envisions a distinct “Dark Sector” with its own particles and interactions, offering a theoretically well motivated explanation for Dark Matter, consistent with astrophysical observations and a thermal production mechanism. The Beam Dump eXperiment (BDX) is an approved experiment at Jefferson Lab designed to search for Light Dark Matter. BDX will utilize an 11 GeV electron beam impinging on a thick target to produce a forward-boosted secondary beam of Light Dark Matter particles, which will then be detected by a dedicated downstream detector. Approved in 2018, BDX is expected to be commissioned in 2026 and run in 2027-2029. My thesis focuses on the preparatory work to deploy the BDX experiment. The detector design has been optimized to balance practicality with enhanced Light Dark Matter detection capabilities. Extensive characterization of detector components has been performed to ensure a precise understanding of detector response. A custom Monte Carlo framework has been developed to simulate Light Dark Matter signal and explore various theoretical models of interest. Additionally, a comprehensive data analysis framework has been developed to maximize the experiment sensitivity to Light Dark Matter, with optimizations based on expected detector performance. The ultimate goal of this thesis is to optimize BDX as a flagship experiment in Light Dark Matter searches, enabling it to probe different Dark Matter models.

Spreafico, M. [Univ. of Genova (Italy)]↗

3 TeV jgun collisions, Single jet type, JET GUN generator: jgun_jet_single_pt3tev

Single jet gun for detector studies: The events contain a single jets from all QCD processes at 14 TeV pp collisions. Events were simulated using the Pythia8 A2 pp tune for 14 TeV. Jets were reconstructed using the anti-kT fastjet algorithm with R=0.4 and pT above 3 TeV (all eta). Then only one jet per event was taken. All particles that fall outside the cone 0.1 around the jet center were removed. The sample with jet cores is designed for detector performance studies to reduce simulation step.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics model enhancements in MARLEY version 2

Large next-generation neutrino detectors, such as those designed for accelerator-based oscillation experiments, are expected to have impressive sensitivity to MeV astrophysical neutrinos generated by the Sun and by supernovae. There are also numerous related prospects to search for MeV-scale phenomena beyond the Standard Model. In contrast to detectors constructed with water and hydrocarbon targets, which will be primarily sensitive to electron antineutrinos via inverse beta decay, the upcoming Deep Underground Neutrino Experiment (DUNE) will provide unparalleled capabilities to measure low-energy electron neutrinos from cosmic sources. Interpreting such future measurements in DUNE will require a high-quality simulation of MeV interaction physics in the argon nucleus. The MARLEY (Model of Argon Reaction Low Energy Yields) neutrino event generator has been designed with the goal of delivering the needed simulation capabilities for DUNE and other argon-based neutrino detectors. In this poster, I will present recent improvements to MARLEY's suite of interaction models, which will be released for general use by the neutrino community in version 2 of the software.

Gardiner, Steven James [Fermilab] (ORCID:000000028↗

Physics model enhancements in MARLEY version 2

Large next-generation neutrino detectors, such as those designed for accelerator-based oscillation experiments, are expected to have impressive sensitivity to MeV astrophysical neutrinos generated by the Sun and by supernovae. There are also numerous related prospects to search for MeV-scale phenomena beyond the Standard Model. In contrast to detectors constructed with water and hydrocarbon targets, which will be primarily sensitive to electron antineutrinos via inverse beta decay, the upcoming Deep Underground Neutrino Experiment (DUNE) will provide unparalleled capabilities to measure low-energy electron neutrinos from cosmic sources. Interpreting such future measurements in DUNE will require a high-quality simulation of MeV interaction physics in the argon nucleus. The MARLEY (Model of Argon Reaction Low Energy Yields) neutrino event generator has been designed with the goal of delivering the needed simulation capabilities for DUNE and other argon-based neutrino detectors. In this talk, I will present recent improvements to MARLEY's physics models, which will be released for general use by the neutrino community in version 2 of the software.

Gardiner, Steven James [Fermilab] (ORCID:000000028↗

SU-F-T-410: Investigation of Treatment Planning Accuracy with the Presence of Magnetic Injection Port (breast Tissue Expander)

Purpose: Mastectomy patients with breast reconstruction usually have a magnetic injection port inside the breast during radiation treatments. The magnet has a very high CT number and produces severe streaking artifact across the entire breast in CT images. Our routine strategy is to replace the artifact volumes with uniform water, and it is necessary to validate that the planned dose, with such an artifact correction, is sufficiently accurate. Methods: A phantom was made with a gelatine-filled container sitting on a Matrixx detector, and the magnetic port was inserted into gelatine with specific depths and orientations. The phantom was scanned on a CT simulator and imported into Eclipse for treatment planning. The dose distribution at the Matrixx detector plane was calculated for raw CT images and artifact-corrected images. The treatment beams were then delivered to the phantom and the dose distributions were acquired by the Matrixx detector. Gamma index was calculated to compare the planned dose and the measurement. Results: Three field sizes (10×10, 15×15 and 20×20) and two depths (50mm and 20mm) were investigated. With the 2%/2mm or 3%/3mm criteria, several points (6–10) failed in the plan for raw CT images, and the number of failure was reduced close to zero for the corrected CT images. An assignment of 10,000 HU to the magnet further reduced the dose error directly under the magnet. Conclusion: It is validated that our routine strategy of artifact correction can effectively reduce the number of failures in the detector plane. It is also recommended to set the magnet with a CT number of 10,000HU, which could potentially improve the dose calculation at the points right behind the magnet.

60 APPLIED LIFE SCIENCES↗

Millimeter wave detection via Autler-Townes splitting in rubidium Rydberg atoms

In this paper, we demonstrate the detection of millimeter waves via Autler-Townes splitting in {sup 85}Rb Rydberg atoms. This method may provide an independent, atom-based, SI-traceable method for measuring mm-wave electric fields, which addresses a gap in current calibration techniques in the mm-wave regime. The electric-field amplitude within a rubidium vapor cell in the WR-10 wave guide band is measured for frequencies of 93.71 GHz and 104.77 GHz. Relevant aspects of Autler-Townes splitting originating from a four-level electromagnetically induced transparency scheme are discussed. We measured the E-field generated by an open-ended waveguide using this technique. Experimental results are compared to a full-wave finite element simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Energy Physics at Tufts University Final Report

In this Final Report, we the researchers of the high energy physics group at Tufts University summarize our works and achievements in three frontier areas of elementary particle physics: (i) Neutrino physics at the Intensity Frontier, (ii) Collider physics at the Energy Frontier, and (iii) Theory investigations of spin structure and quark-gluon dynamics of nucleons using quantum chromodynamics. With our Neutrino research we completed, or else brought to a useful state, the following: Data-taking, physics simulations, physics analysis, physics reporting, explorations of matter effects, and detector component fabrication. We conducted our work as participants in the MINOS, NOvA, and LBNE neutrino oscillation experiments and in the MINERvA neutrino scattering experiment. With our Collider research we completed or else brought to a useful state: Data-taking, development of muon system geometry and tracking codes, software validation and maintenance, physics simulations, physics analysis, searches for new particles, and study of top-quark and B-quark systems. We conducted these activities as participants in the ATLAS proton-proton collider experiment at CERN and in the CDF proton-antiproton collider experiment at Fermilab. In our Theory research we developed QCD-based models, applications of spin phenomenology to fundamental systems, fitting of models to data, presenting and reporting of new concepts and formalisms. The overarching objectives of our research work have always been: 1) to test and clarify the predictions of the Standard Model of elementary particle physics, and 2) to discover new phenomena which may point the way to a more unified theoretical framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recovery Act - Measurement of Parity Violation in Deep Inelastic Scattering and Studies of the Nucleon Spin Structure at JLab 6 and 11 GeV

The program proposed contains two ingredients which aim to address aspects of two of the three research frontiers of nuclear science as identified in the 2007 NSAC Long Range Plan. The first topic, a test of the current Standard Model, is an ongoing project focusing on measurements of the parity-violating asymmetry in ~e-2H deep inelastic scattering (PVDIS). The PVDIS measurement is complementary to other completed or ongoing low- to medium-energy tests of the Standard Model. As the first, exploratory, step, an experiment using a 6 GeV electron beam will be carried out from October to December 2009 at the Thomas Jefferson National Accelerator Facility (JLab). Meanwhile, a program using the upgraded JLab 11 GeV beam is being planned. The PVDIS program as a whole will provide the first precision data on the axial quark neutral-weak coupling constants. This will either put the current Standard Model to a test that has never been done before, or reveal information on where to look for New Physics beyond the current Standard Model. The PVDIS program will also provide results on hadronic physics effects such as charge symmetry violation. The second part of the proposed program uses spin observables to address the research frontier concerning QCD and structure of the nucleon. An experiment using the JLab 6 GeV beam in 2001 showed that, contrary to predictions from perturbative quantum chromodynamics (pQCD), while the valence up quark’s spin is parallel to the nucleon’s spin, the valence down quark’s spin is not. In order to test the limit of QCD in describing the nucleon spin structure to a region beyond the 6 GeV kinematics, this measurement will be extended to a more energetic, “deeper” valence quark region using the upgraded JLab 11 GeV beam with a polarized 3 He target. Although the two topics of the proposed program appear to focus on different physics, for the upgraded JLab 11 GeV beam, both will utilize a new, yet-to-be-built large acceptance spectrometer, called “SoLID”. Once built, SoLID can be used for other topics such as using PVDIS on a proton target to measure the valence quark distributions, using PVDIS on a polarized target to measure new electro-weak interference structure functions of the nucleon, and semi-inclusive deep inelastic scattering experiments. SoLID will greatly enhance the exploration potential of JLab. The proposed program will first focus on completion of the 6 GeV PVDIS experiment, its data analysis and publishing physics results. This 6 GeV experiment will explore whether precision PVDIS measurements are feasible, will set limits on the hadronic physics effects, and will improve our knowledge on the quark neutral weak couplings, optimally by a factor of six. Starting early 2010, efforts will be spent on preparation for the 11 GeV program, focusing on simulations of SoLID, optimization and construction of the SoLID detector package, and studies of the polarized 3 He target and its improvements. Funding support for the whole program is requested here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Background studies for NaI(Tl) detectors in the ANAIS dark matter project

Several large NaI(Tl) detectors, produced by different companies, have been operated in the Canfranc Underground Laboratory (LSC) in the frame of the ANAIS (Annual modulation with NaI Scintillators) project devoted to the direct detection of dark matter. A complete background model has been developed for a 9.6 kg detector (referred as ANAIS-0 prototype) after a long data taking at LSC. Activities from the natural chains of {sup 238}U and {sup 232}Th, and {sup 40}K in the NaI(Tl) crystal were evaluated applying different methods: discrimination of alpha particles vs beta/gamma background by Pulse Shape Analysis for quantifying the content of the natural chains and coincidence techniques for {sup 40}K. Radioactive contaminations in the detector and shielding components were also determined by HPGe spectrometry. Monte Carlo simulations using Geant4 package were carried out to evaluate their contribution. At high energies, most of the measured background is nicely reproduced; at low energy some non-explained components are still present, although some plausible background sources have been analyzed. The {sup 40}K content of the NaI(Tl) crystal has been confirmed to be the dominant contributor to the measured background with this detector. In addition, preliminary results of the background characterization, presently underway at the LSC, of two recently produced NaI(Tl) detectors, with 12.5 kg mass each, will be presented: cosmogenic induced activity has been clearly observed and is being quantified, and {sup 40}K activity at a level ten times lower than in ANAIS-0 has been determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗