Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Cross-Combined Composite Sampling Designs for Identification of Elevated Regions

Analyzing soils for contaminants can be costly. Generally, discrete samples are gathered from within a study area, analyzed by a laboratory and the results are used in a site-specific statistical analysis. Because of the heterogeneities that exist in soil samples within study areas, a large amount of variability and skewness may be present in the sample population. This necessitates collecting a large number of samples to obtain reliable inference on the mean contaminant concentration and to understand the spatial patterns for future remediation. Composite or Incremental sampling is a commonly applied method for gathering multiple discrete samples and physically combining them, such that each combination of discrete samples requires a single laboratory analysis, which reduces cost and can improve the estimates of the mean concentration. While incremental sampling can reduce cost and improve mean estimates, current implementations do not readily facilitate the characterization of spatial patterns or the detection of elevated regions within study areas. The methods we present in this work provide efficient estimation and inference for the mean contaminant concentration over the entire spatial area and enable the identification of high contaminant regions within the area of interest. We develop sample design methodologies that explicitly define the characteristics of these designs (such as sample grid layout) and quantify the number of incremental samples that must be obtained under a design criteria to control false positive and false negative (Type I and II) decision errors. We present the sample design theory and specifications as well as results on simulated and real data.

Hathaway, John E↗

TL/OSL properties of beta irradiated Al2O3:Tm3+ phosphor synthesized by microwave combustion method

Highlights: • TL emission spectra of γ – rayed Al{sub 2}O{sub 3}:Tm{sup 3+} shows Tm{sup 3+} characteristic transitions. • Doping of Tm{sup 3+} ions causes enhancement of TL/OSL. • TL/OSL kinetic parameters are analyzed by CGCD method. • TL mechanism of γ/β – rayed Al{sub 2}O{sub 3}:Tm{sup 3+} was proposed. • TL/OSL dosimetric properties of Al{sub 2}O{sub 3}:Tm{sup 3+} suggests that the material is appropriate for medical dosimetry. - Abstract: This work discusses synthesis of stable α-phase of Al{sub 2}O{sub 3}:Tm{sup 3+} by combustion method using temperature controlled microwave oven. The crystalline phase was analyzed by X-ray diffraction (XRD) technique and average crystallite size was found to be 147 nm. Observations using scanning electron microscope (SEM) image suggest formation of agglomerated particles and energy dispersive x-ray spectroscopy (EDS) confirmed the incorporation of Tm{sup 3+} in Al{sub 2}O{sub 3}. Thermoluminescence emission (TLE) spectrum of γ – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} shows characteristic emissions of Tm{sup 3+}, Cr{sup 3+} and Mn{sup 4+}. TL glow curves of γ – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} exhibit a prominent peak at 453 K along with a shoulder at 496 K. The glow curves of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} were studied in different emission regions using U340 + BG39 (UV band pass), CS759 + BG39 (Blue band pass) and BG39 (Visible band pass) optical glass filters. A prominent peak was observed at 471 K in for all mentioned emission regions and an additional shoulder was observed at 511 K with CS759 + BG39 and BG39 filters. TL glow curve of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} using only BG39 filter had more counts than CS759 + BG39 and U340 + BG39 filters. Further, the effect of Tm{sup 3+} impurity on TL response was studied. TL kinetic parameters were estimated by using computerized glow curve deconvolution (CGCD) technique. The activation energy and frequency factor of prominent peak (471 K) were found to be 1.31 eV and 3.50 × 10{sup 13} s{sup −1} respectively. Optically stimulated luminescence (OSL) characteristics of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} were studied using U340 + BG39 and CS759 + BG39 filters. Highest OSL intensity was observed in UV. OSL curves were deconvoluted by general order decay equation. Life time and photoionization cross section of the traps responsible for OSL were found to be 5.30 s and 3.98 × 10{sup −18} cm{sup 2} respectively. The process of ionization of electron from Tm{sup 3+}, electron trap in host lattice and its recombination mechanism is proposed. Phosphorescence decay of beta irradiated sample was also studied. The lifetime of phosphorescence decay was found to be 140 s for the prominent peak and TL intensity decays 25% after the phosphorescence. TL/OSL dosimetric properties viz. linearity with dose, reusability and minimum detectable dose of the phosphor were characterized for medical dosimetry application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nephron segment specific microRNA biomarkers of pre-clinical drug-induced renal toxicity: Opportunities and challenges

Drug-induced nephrotoxicity is a common drug development complication for pharmaceutical companies. Sensitive, specific, translatable and non-invasive biomarkers of renal toxicity are urgently needed to diagnose nephron segment specific injury. The currently available gold standard biomarkers for nephrotoxicity are not kidney-specific, lack sensitivity for early detection, and are not suitable for renal damage localization (glomerular vs tubulointerstitial injury). MicroRNAs (miRNAs) are increasingly gaining momentum as promising biomarkers of various organ toxicities, including drug induced renal injury. This is mostly due to their stability in easily accessible biofluids, ease of developing nucleic acids detection compared to protein detection assays, as well as their interspecies translatability. Increasing concordance of miRNA findings by standardizing methodology most suitable for their detection and quantitation, as well as characterization of their expression pattern in a cell type specific manner, will accelerate progress toward validation of these miRNAs as biomarkers in pre-clinical, and clinical settings. This review aims to highlight the current pre-clinical findings surrounding miRNAs as biomarkers in two important segments of the nephron, the glomerulus and tubules. - Highlights: • miRNAs are promising biomarkers of drug-induced kidney injury. • Summarized pre-clinical miRNA biomarkers of drug-induced nephrotoxicity. • Described the strengths and challenges associated with miRNAs as biomarkers.

60 APPLIED LIFE SCIENCES↗

Carbon nanotubes grown on metal microelectrodes for the detection of dopamine

Microelectrodes modified with carbon nanotubes (CNTs) are useful for the detection of neurotransmitters because the CNTs enhance sensitivity and have electrocatalytic effects. CNTs can be grown on carbon fiber microelectrodes (CFMEs) but the intrinsic electrochemical activity of carbon fibers makes evaluating the effect of CNT enhancement difficult. Metal wires are highly conductive and many metals have no intrinsic electrochemical activity for dopamine, so we investigated CNTs grown on metal wires as microelectrodes for neurotransmitter detection. In this work, we successfully grew CNTs on niobium substrates for the first time. Instead of planar metal surfaces, metal wires with a diameter of only 25 μm were used as CNT substrates; these have potential in tissue applications due to their minimal tissue damage and high spatial resolution. Scanning electron microscopy shows that aligned CNTs are grown on metal wires after chemical vapor deposition. By use of fast-scan cyclic voltammetry, CNT-coated niobium (CNT-Nb) microelectrodes exhibit higher sensitivity and lower ΔE p value compared to CNTs grown on carbon fibers or other metal wires. The limit of detection for dopamine at CNT-Nb microelectrodes is 11 ± 1 nM, which is approximately 2-fold lower than that of bare CFMEs. Adsorption processes were modeled with a Langmuir isotherm, and detection of other neurochemicals was also characterized, including ascorbic acid, 3,4-dihydroxyphenylacetic acid, serotonin, adenosine, and histamine. CNT-Nb microelectrodes were used to monitor stimulated dopamine release in anesthetized rats with high sensitivity. This research demonstrates that CNT-grown metal microelectrodes, especially CNTs grown on Nb microelectrodes, are useful for monitoring neurotransmitters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A fault-tolerant neutral-atom architecture for universal quantum computation

Quantum error correction (QEC) is essential for the realization of large-scale quantum computers. However, owing to the complexity of operating on the encoded ‘logical’ qubits, understanding the physical principles for building fault-tolerant quantum devices and combining them into efficient architectures is an outstanding scientific challenge. Here we use reconfigurable arrays of up to 448 neutral atoms to implement the key elements of a universal, fault-tolerant quantum processing architecture and experimentally explore their underlying working mechanisms. We first use surface codes to study how repeated QEC suppresses errors, demonstrating 2.14(13)x below-threshold performance in a four-round characterization circuit by leveraging atom loss detection and machine learning decoding. We then investigate logical entanglement using transversal gates and lattice surgery and extend it to universal logic through transversal teleportation with three-dimensional [[15,1,3]] codes, enabling arbitrary-angle synthesis with polylogarithmic overhead. Finally, we develop mid-circuit qubit reuse16, increasing experimental cycle rates by two orders of magnitude and enabling deep-circuit protocols with dozens of logical qubits and hundreds of logical teleportations with [[7,1,3]] and high-rate [[16,6,4]] codes while maintaining constant internal entropy. Our experiments show key principles for efficient architecture design, involving the interplay between quantum logic and entropy removal, judiciously using physical entanglement in logic gates and magic state generation, and leveraging teleportations for universality and physical qubit reset. These results establish foundations for scalable, universal error-corrected processing and its practical implementation in neutral atom systems.

atomic and molecular physics↗

FROM NDE WITH A Q TO SHM AND BEYOND

In the nineteen-sixties, a significant limitation of NDI and NDE became apparent with the advent of fracture mechanics. Fracture mechanics requires quantitative information on defects, which has to be obtained from quantitative non-destructive testing. A DARPA Program directed by Don Thompson provided the point of departure for the journey to put the Q with NDE. The DARPA Program, and subsequent DOD, FAA and industrial programs produced seminal results for diagnostics and prognostics. In diagnostics, measurement models, probability of detection considerations and techniques of defect characterization were developed, which were complemented by damage evolution laws, probabilistic failure analysis and damage progression estimates, for methods of prognostication. The new results in QNDE naturally led to the concept of structural health monitoring (SHM), whereby sensors are permanently installed on structures. An SHM system can provide on-demand (or continuous) information on the state of a structure, so that an assessment of the structural integrity can be made at any time, and timely remedial actions can be taken. In this paper, we review the development of QNDE towards SHM. Sensor development, data processing, materials engineering and solid mechanics play dominant roles in both the diagnostic and the prognostic components of SHM. A probabilistic approach is essential, as will be shown by examples of pre-crack fatigue damage, crack growth and optimization of an inspection schedule.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detection of bottom ferromagnetic electrode oxidation in magnetic tunnel junctions by magnetometry measurements

Surface oxidation of the bottom ferromagnetic (FM) electrode, one of the major detrimental factors to the performance of a magnetic tunnel junction (MTJ), is difficult to avoid during the fabrication process of the MTJ's tunnel barrier. Since Co rich alloys are commonly used for the FM electrodes in MTJs, overoxidation of the tunnel barrier results in the formation of a CoO antiferromagnetic (AF) interface layer which couples with the bottom FM electrode to form a typical AF/FM exchange bias (EB) system. In this work, surface oxidation of the CoFe and CoFeB bottom electrodes was detected via magnetometry measurements of EB characterizations including the EB field, training effect, uncompensated spin density, and enhanced coercivity. Variations in these parameters were found to be related to the surface oxidation of the bottom electrode, among them the change in coercivity is most sensitive. Annealed samples show evidence for an oxygen migration back to the MgO tunnel barrier by annealing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct printing of metal contacts on 4H-SiC for radiation detection

Additive manufacturing (AM) has created the possibility of replacing traditional manufacturing techniques with faster, versatile and cost-effective production options. Here, we employed AM techniques to fabricate silicon carbide (SiC) radiation detectors based on commercial 4H-SiC wafers. Platinum (Pt) nanoparticle inks were synthesized and printed onto the surface of a 4H-SiC wafer using an aerosol jet printing technique to create Schottky diodes for radiation detection. The additive printed detectors were characterized for surface morphology through a scanning electron microscope (SEM) and atomic force microscope (AFM), and electronically by current-voltage (IV), capacitance-voltage (CV) and finally by alpha spectroscopy measurements. Lastly, the printed detector achieved an energy resolution of 3.24% FWHM at 5.486 MeV, compared to 0.62% FWHM of a SiC detector fabricated by conventional clean room technologies and 0.3% FWHM of a commercially available Si detector.

36 MATERIALS SCIENCE↗

N-Glycopeptide Profiling in Arabidopsis Inflorescence

This study presents the first large scale analysis of plant intact glycopeptides. Using wheat germ agglutinin lectin weak affinity chromatography to enrich modified peptides, followed by ETD fragmentation tandem mass spectrometry, glycan compositions on over 1100 glycopeptides from 270 proteins found in Arabidopsis inflorescence tissue were characterized. While some sites were only detected with a single glycan attached, others displayed up to 16 different glycoforms. Among the identified glycopeptides were four modified in non-consensus glycosylation motifs. Finally, while most of the modified proteins are secreted, membrane, ER or Golgi localized proteins, surprisingly N-linked sugars were detected on a protein predicted to be cytosolic or nuclear.

59 BASIC BIOLOGICAL SCIENCES↗

Uncovering multiple populations with washington photometry. I. The globular cluster NGC 1851

The analysis of multiple populations (MPs) in globular clusters (GCs) has become a forefront area of research in astronomy. Multiple red giant branches (RGBs), subgiant branches (SGBs), and even main sequences (MSs) have now been observed photometrically in many GCs, while broad abundance distributions of certain elements have been detected spectroscopically in most, if not all, GCs. UV photometry has been crucial in discovering and analyzing these MPs, but the Johnson U and the Stromgren and Sloan u filters that have generally been used are relatively inefficient and very sensitive to reddening and atmospheric extinction. In contrast, the Washington C filter is much broader and redder than these competing UV filters, making it far more efficient at detecting MPs and much less sensitive to reddening and extinction. Here, we investigate the use of the Washington system to uncover MPs using only a 1 m telescope. Our analysis of the well-studied GC NGC 1851 finds that the C filter is both very efficient and effective at detecting its previously discovered MPs in the RGB and SGB. Remarkably, we have also detected an intrinsically broad MS best characterized by two distinct but heavily overlapping populations that cannot be explained by binaries, field stars, or photometric errors. The MS distribution is in very good agreement with that seen on the RGB, with ∼30% of the stars belonging to the second population. There is also evidence for two sequences in the red horizontal branch, but this appears to be unrelated to the MPs in this cluster. Neither of these latter phenomena have been observed previously in this cluster. The redder MS stars are also more centrally concentrated than the blue MS. This is the first time MPs in an MS have been discovered from the ground, and using only a 1 m telescope. The Washington system thus proves to be a very powerful tool for investigating MPs, and holds particular promise for extragalactic objects where photons are limited.

79 ASTRONOMY AND ASTROPHYSICS↗

FAST PIXEL SPACE CONVOLUTION FOR COSMIC MICROWAVE BACKGROUND SURVEYS WITH ASYMMETRIC BEAMS AND COMPLEX SCAN STRATEGIES: FEBeCoP

Precise measurement of the angular power spectrum of the cosmic microwave background (CMB) temperature and polarization anisotropy can tightly constrain many cosmological models and parameters. However, accurate measurements can only be realized in practice provided all major systematic effects have been taken into account. Beam asymmetry, coupled with the scan strategy, is a major source of systematic error in scanning CMB experiments such as Planck, the focus of our current interest. We envision Monte Carlo methods to rigorously study and account for the systematic effect of beams in CMB analysis. Toward that goal, we have developed a fast pixel space convolution method that can simulate sky maps observed by a scanning instrument, taking into account real beam shapes and scan strategy. The essence is to pre-compute the 'effective beams' using a computer code, 'Fast Effective Beam Convolution in Pixel space' (FEBeCoP), that we have developed for the Planck mission. The code computes effective beams given the focal plane beam characteristics of the Planck instrument and the full history of actual satellite pointing, and performs very fast convolution of sky signals using the effective beams. In this paper, we describe the algorithm and the computational scheme that has been implemented. We also outline a few applications of the effective beams in the precision analysis of Planck data, for characterizing the CMB anisotropy and for detecting and measuring properties of point sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Prevalence of erythromycin-resistant emm92 -type invasive group A streptococcal infections among injection drug users in West Virginia, United States, 2021–23

Abstract Background Increasing incidence of invasive group A Streptococcus (iGAS) disease has been reported in Europe and the USA over the past several years. Coupled with this are observations of higher rates of resistance to erythromycin and clindamycin. Objectives To characterize iGAS and pharyngitis isolates from West Virginia (WV), a US state outside of the national Active Bacteria Core surveillance purview, where risk factors associated with iGAS infections are prevalent. Methods Seventy-seven invasive group A Streptococcus isolates were collected from 67 unique patients at the J.W. Ruby Memorial Hospital Clinical Microbiology Laboratory in WV from 2021 to 2023. Invasive isolates and 20 unique pharyngitis isolates were tested for clindamycin and erythromycin susceptibility in the clinical laboratory. Patient demographic and clinical information was retrieved from patient electronic health records. Isolates were further characterized based on emm subtype and detection of MLSB resistance determinants. Results Twenty-six (39%) isolates were of a single emm92 type. All emm92 isolates were uniformly erythromycin/clindamycin resistant with inducible or constitutive MLSB resistance imparted by the plasmid-borne erm(T) gene. The majority of emm92 infections were associated with adult patients who reported IV drug use, whereas no pharyngitis infections were caused by an emm92 strain. Overall, 51 (76%) of the 67 iGAS isolates were determined to carry MLSB resistance. Conclusions Isolates of emm92 type (clonal subtype emm92.0) were associated with iGAS infections in adult IV drug users, but not with paediatric pharyngitis, and were uniformly resistant to erythromycin and clindamycin.

Powell, Lillie M.↗

Unresolved Gamma-Ray Sky through its Angular Power Spectrum

The gamma-ray sky has been observed with unprecedented accuracy in the last decade by the Fermi-large area telescope (LAT), allowing us to resolve and understand the high-energy Universe. The nature of the remaining unresolved emission [unresolved gamma-ray background (UGRB)] below the LAT source detection threshold can be uncovered by characterizing the amplitude and angular scale of the UGRB fluctuation field. This Letter presents a measurement of the UGRB autocorrelation angular power spectrum based on eight years of Fermi-LAT Pass 8 data products. The analysis is designed to be robust against contamination from resolved sources and noise systematics. The sensitivity to subthreshold sources is greatly enhanced with respect to previous measurements. We find evidence (with ~ 3.7σ significance) that the scenario in which two classes of sources contribute to the UGRB signal is favored over a single class. A double power law with exponential cutoff can explain the anisotropy energy spectrum well, with photon indices of the two populations being 2.55 ± 0.23 and 1.86 ± 0.15.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultraviolet Fluorescence Imaging for Photovoltaic Module Metrology: Best Practices and Survey of Features Observed in Fielded Modules

As the photovoltaics (PV) industry grows in sophistication, so must the extent to which systems are characterized. UV Fluorescence (UVF) imaging is a valuable, easy-to-perform, high-throughput, nonintrusive technique for characterizing modules in the field and in the lab. However, UVF is still a relatively new technique, and many in the PV industry are still unaware of its potential. We provide a guideline for obtaining, processing, and interpreting UVF images. We have provided a list of considerations for imaging hardware and settings, a suggested pipeline for image processing, and details on a survey of features shown in UVF images. As a result, a new database with UVF images of 7190 modules and another database curated by BrightSpot Automation are publicly available.

14 SOLAR ENERGY↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

Spatiotemporal sampling of near-petahertz vortex fields

Measuring the field of visible light with high spatial resolution has been challenging, as many established methods only detect a focus-averaged signal. Here, we introduce a near-field method for optical field sampling that overcomes that limitation by employing the localization of the enhanced near-field of a nanometric needle tip. A probe field perturbs the photoemission from the tip, which is induced by a pump pulse, generating a field-dependent current modulation that can easily be captured with our electronic detection scheme. The approach provides reliable characterization of near-petahertz fields. We show that not only the spiral wavefront of visible femtosecond light pulses carrying orbital angular momentum (OAM) can be resolved but also the field evolution with time in the focal plane. Additionally, our method is polarization sensitive, which makes it applicable to vectorial field reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of trigger and cascade section runtimes in 6MV switches using fiber coupled photo detectors

Since October 2007 Sandia National Laboratories operates the refurbished Z machine at an improved load current of 26 MA yielding 400 TW of x-ray power. The current pulse shape to the load is controlled by 36 independently timed laser-triggered gas switches (LTGS). As part of the refurbishment effort, a fiber coupled laser spark detector (LSD) system has been installed which is able to detect the laser generated plasma in situ inside the trigger section of the HV switch. In this paper we describe how this detection system can be used to characterize the discharge dynamics of these 5.9 MV, 820 kA switches.

Schwarz, Jens↗

Detecting Single Electrons in IOTA [Slides]

Detect synchrotron-light signal and characterize backgrounds in IOTA for 1) Beam diagnostics: turn-by-turn intensity monitor with wide dynamic range, from nominal intensities (~10 9 particles) down to single electrons; 2) Scientific experiments in IOTA: what is the time structure of radiation emission from a single electron in a storage ring? Is it random, regular, chaotic? Is there correlation between the emission from different dipoles?

43 PARTICLE ACCELERATORS↗