Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Heavy Ion Microbeam- and Broadbeam-Induced Current Transients in SiGe HBTs

IBM 5AM SiGe HBT is device-under-test. High-speed measurement setup. Low-impedance current transient measurements. SNL, JYFL, GANIL. Microbeam to broadbeam position inference. Improvement to state-of-the-art. Microbeam (SNL) transients reveal position dependent heavy ion response, Unique response for different device regions Unique response for different bias schemes. Similarities to TPA pulsed-laser data. Broadbeam transients (JYFL and GANIL) provide realistic heavy ion response. Feedback using microbeam data. Overcome issues of LET and ion range with microbeam. **Angled Ar-40 data in full paper. Data sets yield first-order results, suitable for TCAD calibration feedback.

Pellish, Jonathan A.↗

Solar cell measurements in the field

Portable test instrument makes rapid current, voltage, and power measurements of photovoltaic solar cell arrays in field as well as in laboratory.

Ross, R. G., Jr.↗

Hall-Effect Current Sensors For Integrated Circuits

Built-in devices measure direct or alternating currents. Hall-effect sensors placed near constriction in conductor strip. Differential configuration reduces effects of stray magnetic fields, nonlinearities, and changes in temperature. Preliminary design studies and experiments with macroscopic commercial Hall-effect sensors conducted to assess feasibility, limitations, and need for further research and development of this concept. Potential applications include programmable power supplies and protective circuitry.

Rippel, Wally E.↗

Circuit For Current-vs.-Voltage Tests Of Semiconductors

Circuit designed for measurement of dc current-versus-voltage characteristics of semiconductor devices. Operates in conjunction with x-y pen plotter or digital storage oscilloscope, which records data. Includes large feedback resistors to prevent high currents damaging device under test. Principal virtues: low cost, simplicity, and compactness. Also used to evaluate diodes and transistors.

Huston, Steven W.↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Measurements of Tc (Q,P): Depression of the Superfluid Transition Temperature by a Heat Current Along the Lambda Line

We report experimental measurements of Tc (Q,P) for heat currents (Q) between I1and 100 micro W/sq cm and pressure (P) between SVP and 15 bar. The measurements were performed in a normal gravity environment, using the low-gravity simulator facility at JPL without the magnet being energized. The sample pressure was controlled to 0.1 micro bar using a hot volume, and a Straty-Adams capacitive pressure gauge. The total volume of helium in the sample cell and the hot volume was held constant using a pneumatic low temperature valve. A melting curve thermometer (MCT) measured the transition temperature (Tc) with a resolution of about 10 nK through a sidewall probe of the thermal conductivity sample cell. We employed the same measurement technique and procedure described by DAS. Preliminary results indicate that Tc (Q,P) depends very little on the pressure in the pressure range between SVP and 15 bar with a variation in the amplitude of Tc(Q,P) of less than about 5% observable in this pressure range. According to the Renormalization-group theory calculation by Haussmann and Dohm, the amplitude of Tc (Q,P) has a leading pressure-dependence term proportional to xi(sub 0) (sup (1/nu)), where xi(sub 0) is the correlation-length amplitude and nu is the correlation-length exponent. Thus, a small pressure dependence of the amplitude of Tc (Q,P) is expected since xi(sub 0) is very weakly dependent on pressure between SVP and 15 bar, consistent with our measurements.

Liu, Yuan-Ming↗

Measurement of the $\bar ν_μ-$Hydrogen Charged-Current Quasi-Elastic Cross Section using the NOvA Near Detector

We report a measurement of the total cross section for muon antineutrino charged-current quasi-elastic scattering on hydrogen, $\bar ν_μ{\rm H} \to μ^+ n$, in the NOvA near detector using a $1.2\times10^{21}$ proton-on-target exposure in the NuMI beam. A selection based on topological and kinematic constraints yields 35,509 signal events in the hydrogen-rich ($10.8\%$) detector, providing the highest statistics of (anti)neutrino--hydrogen interactions measured to date. Backgrounds from (anti)neutrino interactions on heavier nuclei are constrained using dedicated data control samples, significantly reducing the related systematic uncertainties. We obtain a value $σ(\bar ν_μ{\rm H} \to μ^+ n) = 0.538 \pm 0.009 ({\rm stat}) \pm 0.010 ({\rm syst}) \pm0.055 ({\rm flux}) \times 10^{-38}$ cm$^2$ for the total cross section at an average energy of 1.9 GeV, the most precise total cross-section measurement of this process to date. The combined statistical and non-flux systematic uncertainty is more than four times smaller than the flux uncertainty, allowing a future use of this measurement to constrain the absolute $\bar ν_μ$ flux.

Abubakar, S. [Erciyes U.]↗

Measurement of the $\bar ν_μ-$Hydrogen Charged-Current Quasi-Elastic Cross Section using the NOvA Near Detector

We report a measurement of the total cross section for muon antineutrino charged-current quasi-elastic scattering on hydrogen, $\bar ν_μ{\rm H} \to μ^+ n$, in the NOvA near detector using a $1.2\times10^{21}$ proton-on-target exposure in the NuMI beam. A selection based on topological and kinematic constraints yields 35,509 signal events in the hydrogen-rich ($10.8\%$) detector, providing the highest statistics of (anti)neutrino--hydrogen interactions measured to date. Backgrounds from (anti)neutrino interactions on heavier nuclei are constrained using dedicated data control samples, significantly reducing the related systematic uncertainties. We obtain a value $σ(\bar ν_μ{\rm H} \to μ^+ n) = 0.538 \pm 0.009 ({\rm stat}) \pm 0.010 ({\rm syst}) \pm0.055 ({\rm flux}) \times 10^{-38}$ cm$^2$ for the total cross section at an average energy of 1.9 GeV, the most precise total cross-section measurement of this process to date. The combined statistical and non-flux systematic uncertainty is more than four times smaller than the flux uncertainty, allowing a future use of this measurement to constrain the absolute $\bar ν_μ$ flux.

Abubakar, S. [Erciyes U.]↗

Temperature dependence of damage coefficient in electron irradiated solar cells

Measurements of light-generated current vs cell temperature on electron-irradiated n/p silicon solar cells show the temperature coefficient of this current to increase with increasing fluence for both 10-ohm and 20-ohm cells. A relationship between minority-carrier diffusion length and light-generated current was derived by combining measurements of these two parameters: vs fluence at room temperature, and vs cell temperature in cells irradiated to a fluence of 1 x 10 to the 15th power e/sq cm. This relationship was used, together with the light-generated current data, to calculate the temperature dependence of the diffusion-length damage coefficient. The results show a strong decrease in the damage coefficient with increasing temperature in the range experienced by solar panels in synchronous earth orbit.

Faith, T. J.↗

First Simultaneous Measurement of Differential Muon-Neutrino Charged-Current Cross Sections on Argon for Final States with and without Protons Using MicroBooNE Data

We report the first double-differential neutrino-argon cross section measurement made simultaneously for final states with and without protons for the inclusive muon neutrino charged-current interaction channel. The proton kinematics of this channel are further explored with a differential cross section measurement as a function of the leading proton’s kinetic energy that extends across the detection threshold. These measurements use data collected with the MicroBooNE detector from 6.4 × 10 20 protons on target from the Fermilab booster neutrino beam with a mean neutrino energy of ∼ 0.8 GeV . Extensive data-driven model validation utilizing the conditional constraint formalism is employed. This motivates enlarging the uncertainties with an empirical reweighting approach to minimize the possibility of extracting biased cross section results. The extracted nominal flux-averaged cross sections are compared to widely used event generator predictions revealing severe mismodeling of final states without protons for muon neutrino charged-current interactions, possibly from insufficient treatment of final state interactions. These measurements provide a wealth of new information useful for improving event generators which will enhance the sensitivity of precision measurements in neutrino experiments. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of three-dimensional inclusive muon-neutrino charged-current cross sections on argon with the MicroBooNE detector

We report the measurement of the triple-differential cross section d 3 σ/dE vis d cos(θ μ )dP μ for inclusive muon-neutrino charged-current scattering on argon. This measurement utilizes data from 6.4 x 10 20 protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam with a mean neutrino energy of approximately 0.8 GeV. The mapping from reconstructed kinematics to truth quantities is validated within uncertainties by comparing the distribution of reconstructed hadronic energy in data to that of the model prediction in different muon scattering angle bins after applying a conditional constraint from the muon momentum distribution in data. The success of this validation provides confidence that the energy transfer in the MicroBooNE detector is well-modeled within simulation uncertainties, enabling a reliable unfolding to a triple-differential cross section defined at the nominal neutrino flux over muon momentum, muon scattering angle, and visible neutrino energy. This validation not only supports accurate cross-section extraction, but also establishes a critical foundation for tuning interaction models used in future neutrino oscillation measurements. The unfolded measurement covers an extensive phase space, providing a wealth of information useful for future liquid argon time projection chamber experiments measuring neutrino oscillations. Comparisons against a number of commonly used model predictions are included and their performance in different parts of the available phase-space is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wideband Instrument for Snow Measurements (WISM)

This presentation discusses current efforts to develop a Wideband Instrument for Snow Measurements (WISM). The objective of the effort are as follows: to advance the utility of a wideband active and passive instrument (8-40 gigahertz) to support the snow science community; improve snow measurements through advanced calibration and expanded frequency of active and passive sensors; demonstrate science utility through airborne retrievals of snow water equivalent (SWE); and advance the technology readiness of broadband current sheet array (CSA) antenna technology for spaceflight applications.

Radiometer↗

Shift photovoltaic current and magnetically induced bulk photocurrent in piezoelectric sillenite crystals

Recently, it has been shown how shift and ballistic currents in piezoelectric sillenite crystals Bi 12 GeO 20 and Bi 12 SiO 20 can be separated experimentally under the assumption that the shift component of the circular current is small. However, it has been claimed that the shift and ballistic currents cannot be quantified by this method, due to the magnetophotovoltaic effect caused either by the change of the crystal's spatial symmetry in the magnetic field or by the breaking of time-reversal symmetry. Presently, we report observations of photovoltaic currents in Bi 12 SiO 20 , excited by linearly and circularly polarized light under weak external magnetic field, as well as measurements of the corresponding photo-Hall signals. Further, we demonstrate that the magnetophotovoltaic current constitutes a significant fraction of the measured current in the Hall direction for Bi 12 SiO 20 under specific experimental conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Passive Inter-Photon Imaging

Digital camera pixels measure image intensities by converting incident light energy into an analog electrical current, and then digitizing it into a fixed-width binary representation. This direct measurement method, while conceptually simple, suffers from limited dynamic range and poor performance under extreme illumination --- electronic noise dominates under low illumination, and pixel full-well capacity results in saturation under bright illumination. We propose a novel intensity cue based on measuring inter-photon timing, defined as the time delay between detection of successive photons. Based on the statistics of inter-photon times measured by a time-resolved single-photon sensor, we develop theory and algorithms for a scene brightness estimator which works over extreme dynamic range; we experimentally demonstrate imaging scenes with a dynamic range of over ten million to one. The proposed techniques, aided by the emergence of single-photon sensors such as single-photon avalanche diodes (SPADs) with picosecond timing resolution, will have implications for a wide range of imaging applications: robotics, consumer photography, astronomy, microscopy and biomedical imaging.

97 MATHEMATICS AND COMPUTING↗

Integrating Data Sources for Improved Safeguards and Accountancy of Electrochemical Fuel Reprocessing Systems. Final Report

Electrochemical reprocessing (also commonly known as “pyroprocessing”) of used nuclear fuel is an alternative to aqueous reprocessing that confers a number of advantages, including the ability to process more recently-discharged fuel, smaller resultant waste volumes, and the lack of isolation of plutonium in the product stream. While electrochemical reprocessing systems have seen a significant research and development effort, nuclear safeguards and security of these systems remains under-developed, particularly given the significant differences in operating environment and process flowsheet compared with established aqueous methods. Objective 4 of DOE’s nuclear energy research and development activities in Nuclear Energy Research and Development Roadmap is: “Understand and minimize the risks of nuclear proliferation and terrorism.” Material Control & Accountancy (MC&A) programs at nuclear processing plants deter and detect theft and diversion of nuclear material by both outside and inside adversaries. Empirical modeling and data analytics of online measurements and state indicators can improve the timeliness of detection and reduce the uncertainty in accountancy measures. To support the development and demonstration of such methods, data are needed that capture expected measurement values collected throughout electrochemical reprocessing facilities. A review of the available literature of current research in measurements for electrochemical reprocessing systems identified twenty-two candidate measurement methodologies, which characterize fuel/salt composition, concentrations of various isotopes and elements, and operational parameters throughout the reprocessing facility. Four primary measurement methodologies have been simulated based on either physical simulations or empirical correlations: gamma emissions, neutron emissions, hybrid k-edge densitometry (HKED), and cyclic voltammetry. Initial investigation into the use of these measures for process monitoring and detection suggests the approach is viable and worthy of further investigation. This report summarizes efforts to generate signatures of key measurements during operation of electrochemical reprocessing facilities and initial investigation of data analytics to support process monitoring, diversion detection, and accountancy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Secondary electron yields of solar system ices

The secondary electron yields of H2O, CO2, NH3, and CH3OH ices have been measured as a function of electron beam energy in the 2- to 30-keV energy range. The ices were produced on a liquid-nitrogen-cooled cold finger and transferred under vacuum to a SEM where the yield measurements were made. The imaging capabilities of the SEM provide a means of correlating the yield measurements with the morphology of the ices and are also used to monitor charging effects. The yields were determined by measuring the amplified current from a secondary electron detector and calibrating this current signal with the amplified current signal from samples of metals with known secondary electron yields. Each of the measured yields is found to decrease with an increase in energy in the 2- to 30-keV range. Estimates are given for the maximum secondary electron yield Y(max) of each ice and the energy at which this maximum yield occurs. Implications for the charging of solar system ice grains are discussed.

Suszcynsky, David M.↗

Reflectance of snow as measured in situ and from space in sub-arctic areas in Canada and Alaska

An effort is made to measure snow reflectance under different snow and surface conditions, as well as to improve current capabilities for measuring snow reflectance over large regions of space, on the basis of visible and near-IR measurements of clean and dirty snow near Yellowknife, Canada, using both a portable spectrometer and the Landsat TM. Similar measurements were acquired over snow-covered glaciers in Alaska. Visible reflectance of the dirty snow was 30 percent lower than for cleaner snow; the shapes of the reflectance curves were also flatter for the dirty snow. The shape of the reflectance curves and the anisotropic reflectance properties are more useful in differentiating snow type and moisture type than actual reflectances.

Hall, D. K.↗

Deterministic Multiaxial Creep and Creep Rupture Enhancements for CARES/Creep Integrated Design Code

High temperature and long duration applications of monolithic ceramics can place their failure mode in the creep rupture regime. A previous model advanced by the authors described a methodology by which the creep rupture life of a loaded component can be predicted. That model was based on the life fraction damage accumulation rule in association with the modified Monkman-Grant creep rupture criterion. However, that model did not take into account the deteriorating state of the material due to creep damage (e.g., cavitation) as time elapsed. In addition, the material creep parameters used in that life prediction methodology, were based on uniaxial creep curves displaying primary and secondary creep behavior, with no tertiary regime. The objective of this paper is to present a creep life prediction methodology based on a modified form of the Kachanov-Rabotnov continuum damage mechanics (CDM) theory. In this theory, the uniaxial creep rate is described in terms of sum, temperature, time, and the current state of material damage. This scalar damage state parameter is basically an abstract measure of the current state of material damage due to creep deformation. The damage rate is assumed to vary with stress, temperature, time, and the current state of damage itself. Multiaxial creep and creep rupture formulations of the CDM approach are presented in this paper. Parameter estimation methodologies based on nonlinear regression analysis are also described for both, isothermal constant stress states and anisothermal variable stress conditions This creep life prediction methodology was preliminarily added to the integrated design code CARES/Creep (Ceramics Analysis and Reliability Evaluation of Structures/Creep), which is a postprocessor program to commercially available finite element analysis (FEA) packages. Two examples, showing comparisons between experimental and predicted creep lives of ceramic specimens, are used to demonstrate the viability of Ns methodology and the CARES/Creep program.

Jadaan, Osama M.↗