Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Continual learning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

Rethinking Visual Analytics for Streaming Data Applications

In the age of data science, the use of interactive information visualization techniques has become increasingly ubiquitous. From online scientific journals to the New York Times graphics desk, the utility of interactive visualization for both storytelling and analysis has become ever more apparent. As these techniques have become more readily accessible, the appeal of combining interactive visualization with computational analysis continues to grow. Arising out of a need for scalable, human-driven analysis, primary objective of visual analytics systems is to capitalize on the complementary strengths of human and machine analysis, using interactive visualization as a medium for communication between the two. These systems leverage developments from the fields of information visualization, computer graphics, machine learning, and human-computer interaction to support insight generation in areas where purely computational analyses fall short. Over the past decade, visual analytics systems have generated remarkable advances in many historically challenging analytical contexts. These include areas such as modeling political systems [Crouser et al. 2012], detecting financial fraud [Chang et al. 2008], and cybersecurity [Harrison et al. 2012]. In each of these contexts, domain expertise and human intuition is a necessary component of the analysis. This intuition is essential to building trust in the analytical products, as well as supporting the translation of evidence into actionable insight. In addition, each of these examples also highlights the need for scalable analysis. In each case, it is infeasible for a human analyst to manually assess the raw information unaided, and the communication overhead to divide the task between a large number of analysts makes simple parallelism intractable. Regardless of the domain, visual analytics tools strive to optimize the allocation of human analytical resources, and to streamline the sensemaking process on data that is massive, complex, incomplete, and uncertain in scenarios requiring human judgment.

97 MATHEMATICS AND COMPUTING↗

East Asian Rainbands and Associated Circulation over the Tibetan Plateau Region

Abstract Rainbands that migrate northward from spring to summer are persistent features of the East Asian summer monsoon. This study employs a machine learning algorithm to identify individual East Asian rainbands from May to August in the 6-hourly ERA-Interim reanalysis product and captures rainband events during these months for the period 1979–2018. The median duration of rainband events at any location in East Asia is 12 h, and the centroids of these rainbands move northward continuously from approximately 28°N in late May to approximately 33°N in July, instead of making jumps between quasi-stationary periods. Whereas the length and overall area of the rainbands grow monotonically from May to June, the intensity of the rainfall within the rainband dips slightly in early June before it peaks in late June. We find that extratropical northerly winds on all pressure levels over East China are the most important anomalous flow accompanying the rainband events. The anomalous northerlies augment climatological background northerlies in bringing low moist static energy air and thus generate the front associated with the rainband. Persistent lower-tropospheric southerly winds bring in moisture that feeds the rainband and are enhanced a few days prior to rainband events, but they are not directly tied to the actual rainband formation. The background northerlies could originate as part of the Rossby waves resulting from the jet stream interaction with the Tibetan Plateau. The ageostrophic circulation in the jet entrance region peaks in May and weakens in June and July and does not prove to be critical to the formation of the rainbands.

54 ENVIRONMENTAL SCIENCES↗

The Global Ocean Observing System: One perspective

This document presents a possible organization for a Global Ocean Observing System (GOOS) within the Intergovernmental Oceanographic Commission and the joint ocean programs with the World Meteorological Organization. The document and the organization presented here is not intended to be definitive, complete or the best possible organization for such an observation program. It is presented at this time to demonstrate three points. The first point to be made is that an international program office for GOOS along the lines of the WOCE and TOGA IPOs is essential. The second point is that national programs will have to continue to collect data at the scale of WOCE plus TOGA and more. The third point is that there are many existing groups and committees within the IOC and joint IOC/WMO ocean programs that can contribute essential experience to and form part of the basis of a Global Ocean Observing System. It is particularly important to learn from what has worked and what has not worked in the past if a successful ocean observing system is to result.

Wilson, J. Ron↗

RIACS/USRA

The Research Institute for Advanced Computer Science (RIACS) was established by the Universities Space Research Association (USRA) at the NASA Ames Research Center (ARC) on 6 June 1983. RIACS is privately operated by USRA, a consortium of universities with research programs in the aerospace sciences, under contract with NASA. The primary mission of RIACS is to provide research and expertise in computer science and scientific computing to support the scientific missions of NASA ARC. The research carried out at RIACS must change its emphasis from year to year in response to NASA ARC's changing needs and technological opportunities. A flexible scientific staff is provided through a university faculty visitor program, a post doctoral program, and a student visitor program. Not only does this provide appropriate expertise but it also introduces scientists outside of NASA to NASA problems. A small group of core RIACS staff provides continuity and interacts with an ARC technical monitor and scientific advisory group to determine the RIACS mission. RIACS activities are reviewed and monitored by a USRA advisory council and ARC technical monitor. Research at RIACS is currently being done in the following areas: Parallel Computing, Advanced Methods for Scientific Computing, High Performance Networks and Technology, and Learning Systems. Parallel compiler techniques, adaptive numerical methods for flows in complicated geometries, and optimization were identified as important problems to investigate for ARC's involvement in the Computational Grand Challenges of the next decade.

Oliger, Joseph↗

The widest practicable dissemination: The NASA technical report server

The National Aeronautics and Space Act of 1958 established NASA and charged it to 'provide for the widest practicable and appropriate dissemination of information concerning...its activities and the results thereof.' The search for innovative methods to distribute NASA's information lead a grass-roots team to create the NASA Technical Report Server (NTRS), which uses the World Wide Web and other popular Internet-based information systems as search engines. The NTRS is an inter-center effort which provides uniform access to various distributed publication servers residing on the Internet. Users have immediate desktop access to technical publications from NASA centers and institutes. The NTRS is comprised of several units, some constructed especially for inclusion in NTRS, and others that are existing NASA publication services that NTRS reuses. This paper presents the NTRS architecture, usage metrics, and the lessons learned while implementing and maintaining the services over the initial six-month period. The NTRS is largely constructed with freely available software running on existing hardware. NTRS builds upon existing hardware and software, and the resulting additional exposure for the body of literature contained will allow NASA to ensure that its institutional knowledge base will continue to receive the widest practicable and appropriate dissemination.

Nelson, Michael L.↗

International Space Station Benefits for Humanity

The ISS partnership has seen a substantial increase in research accomplished, crew efforts devoted to research, and results of ongoing research and technology development. The ISS laboratory is providing a unique environment for research and international collaboration that benefits humankind. Benefits come from the engineering development, the international partnership, and from the research results. Benefits can be of three different types: scientific discovery, applications to life on Earth, and applications to future exploration. Working across all ISS partners, we identified key themes where the activities on the ISS improve the lives of people on Earth--not only within the partner nations, but also in other nations of the world. Three major themes of benefits to life on earth emerged from our review: benefits to human health, education, and Earth observation and disaster response. Other themes are growing as use of the ISS continues. Benefits to human health range from advancements in surgical technology, improved telemedicine, and new treatments for disease. Earth observations from the ISS provide a wide range of observations that include: marine vessel tracking, disaster monitoring and climate change. The ISS participates in a number of educational activities aimed to inspire students of all ages to learn about science, technology, engineering and mathematics. To date over 63 countries have directly participated in some aspect of ISS research or education. In summarizing these benefits and accomplishments, ISS partners are also identifying ways to further extend the benefits to people in developing countries for the benefits of humankind.

Thumm, Tracy L.↗

International Space Station Research Benefits for Humanity

The ISS partnership has seen a substantial increase in research accomplished, crew efforts devoted to research, and results of ongoing research and technology development. The ISS laboratory is providing a unique environment for research and international collaboration that benefits humankind. Benefits come from the engineering development, the international partnership, and from the research results. Benefits can be of three different types: scientific discovery, applications to life on Earth, and applications to future exploration. Working across all ISS partners, we identified key themes where the activities on the ISS improve the lives of people on Earth -- not only within the partner nations, but also in other nations of the world. Three major themes of benefits to life on earth emerged from our review: benefits to human health, education, and Earth observation and disaster response. Other themes are growing as use of the ISS continues. Benefits to human health range from advancements in surgical technology, improved telemedicine, and new treatments for disease. Earth observations from the ISS provide a wide range of observations that include: marine vessel tracking, disaster monitoring and climate change. The ISS participates in a number of educational activities aimed to inspire students of all ages to learn about science, technology, engineering and mathematics. To date over 63 countries have directly participated in some aspect of ISS research or education. In summarizing these benefits and accomplishments, ISS partners are also identifying ways to further extend the benefits to people in developing countries for the benefits of humankind.

Thumm, Tracy↗

AI Benchmark Democratization and Carpentry

Benchmarks are a cornerstone of modern machine learning, enabling reproducibility, comparison, and scientific progress. However, AI benchmarks are increasingly complex, requiring dynamic, AI-focused workflows. Rapid evolution in model architectures, scale, datasets, and deployment contexts makes evaluation a moving target. Large language models often memorize static benchmarks, causing a gap between benchmark results and real-world performance. Beyond traditional static benchmarks, continuous adaptive benchmarking frameworks are needed to align scientific assessment with deployment risks. This calls for skills and education in AI Benchmark Carpentry. From our experience with MLCommons, educational initiatives, and programs like the DOE's Trillion Parameter Consortium, key barriers include high resource demands, limited access to specialized hardware, lack of benchmark design expertise, and uncertainty in relating results to application domains. Current benchmarks often emphasize peak performance on top-tier hardware, offering limited guidance for diverse, real-world scenarios. Benchmarking must become dynamic, incorporating evolving models, updated data, and heterogeneous platforms while maintaining transparency, reproducibility, and interpretability. Democratization requires both technical innovation and systematic education across levels, building sustained expertise in benchmark design and use. Benchmarks should support application-relevant comparisons, enabling informed, context-sensitive decisions. Dynamic, inclusive benchmarking will ensure evaluation keeps pace with AI evolution and supports responsible, reproducible, and accessible AI deployment. Community efforts can provide a foundation for AI Benchmark Carpentry.

von Laszewski, Gregor [Virginia U.]↗

Creating a Training Dataset for Semantic Segmentation of Canal Networks for Irrigation Modernization

Canal infrastructure has provided critical irrigation water to the western United States for over a century. To continue providing vital water resources to the semi-arid West, irrigation systems must undergo maintenance and modernization. Many canal companies are resource-constrained, and because funding opportunities often require detailed knowledge of existing infrastructure, they can struggle to secure financial capital. We address this problem by creating training data for a semantic segmentation deep learning model to map canal networks throughout the western United States. To create a diverse and robust training dataset, we labelled 1-m NAIP imagery with the locations of no canals, wet canals, and dry/vegetated canals. Since creating these datasets is time consuming, we first developed a preprocessing methodology to identify canals within our four study areas. We used NAIP imagery and provided canal centerline data to buffer, standardize, and cluster the imagery, automating the labeling process as much as possible. However, this still required manual cleaning and manual classification of canal type. Challenges arose when canals were interrupted (e.g., road culverts or piped sections) or when nearby features shared similar characteristics (e.g., irrigated fields, trees, and shadows). Combining automated preprocessing with manual refinement produced four detailed canal masks to be used in the semantic segmentation model developed by Richard Tapia.

13 - HYDRO ENERGY↗

Improving an Acoustic Vehicle Detector Using an Iterative Self-Supervision Procedure

In many non-canonical data science scenarios, obtaining, detecting, attributing, and annotating enough high-quality training data is the primary barrier to developing highly effective models. Moreover, in many problems that are not sufficiently defined or constrained, manually developing a training dataset can often overlook interesting phenomena that should be included. To this end, we have developed and demonstrated an iterative self-supervised learning procedure, whereby models are successfully trained and applied to new data to extract new training examples that are added to the corpus of training data. Successive generations of classifiers are then trained on this augmented corpus. Using low-frequency acoustic data collected by a network of infrasound sensors deployed around the High Flux Isotope Reactor and Radiochemical Engineering Development Center at Oak Ridge National Laboratory, we test the viability of our proposed approach to develop a powerful classifier with the goal of identifying vehicles from continuously streamed data and differentiating these from other sources of noise such as tools, people, airplanes, and wind. Using a small collection of exhaustively manually labeled data, we test several implementation details of the procedure and demonstrate its success regardless of the fidelity of the initial model used to seed the iterative procedure. Finally, we demonstrate the method’s ability to update a model to accommodate changes in the data-generating distribution encountered during long-term persistent data collection.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Random Forest Modeling Strategies for Multi-Step Wind Speed Forecasting

Although the random forest (RF) model is a powerful machine learning tool that has been utilized in many wind speed/power forecasting studies, there has been no consensus on optimal RF modeling strategies. This study investigates three basic questions which aim to assist in the discernment and quantification of the effects of individual model properties, namely: (1) using a standalone RF model versus using RF as a correction mechanism for the persistence approach, (2) utilizing a recursive versus direct multi-step forecasting strategy, and (3) training data availability on model forecasting accuracy from one to six hours ahead. These questions are investigated utilizing data from the FINO1 offshore platform and Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) C1 site, and testing results are compared to the persistence method. At FINO1, due to the presence of multiple wind farms and high inter-annual variability, RF is more effective as an error-correction mechanism for the persistence approach. The direct forecasting strategy is seen to slightly outperform the recursive strategy, specifically for forecasts three or more steps ahead. Finally, increased data availability (up to ~8 equivalent years of hourly training data) appears to continually improve forecasting accuracy, although changing environmental flow patterns have the potential to negate such improvement. We hope that the findings of this study will assist future researchers and industry professionals to construct accurate, reliable RF models for wind speed forecasting.

54 ENVIRONMENTAL SCIENCES↗

Students Planting Research Of Use To Space (SPROUTS) Networking and Engagement of Interns at Kennedy Space Center

While Kennedy Space Center (KSC) has had summer interns in the life sciences for many years, beginning in 2016, the internship program was re-envisioned. Rather than having many interns in the summer with numerous innovative small projects created primarily for this purpose, the current model is to offer internship opportunities every semester (Spring, Summer, and Fall), so that research is continuous and sustained. Since 2016 we have had 64 internship opportunities for undergraduate and graduate students in the areas of space crop production and microgravity simulation support. Some students have participated in more than one opportunity, so 52 separate individuals have participated in this program. While interns primarily worked with individual mentors on a main project, most also worked on group projects with other interns or developed smaller secondary projects on their own initiative. In addition, all interns participated in a weekly Lunch, Learn, and Discuss seminar series where they were encouraged to present their research, learn from scientists at KSC, and engage with members of the space life sciences community. When the face-to-face spring internship of 2020 ended prematurely, we resumed the weekly seminar series as a virtual event, and this led to the concept of engaging former interns. Current and former interns were invited to participate in the on-going virtual series, and 46 asked to be included on the mailing list. Our current seminar series involves remote seminars or hosted discussions from contacts within and outside of the agency, and engages a large network of current scientists and former interns with an weekly participation averaging 40-50 people. Speakers include experts from industry, academia, and other space agencies working on topics of interest to KSC space life science researchers. In addition, this series has served as a brain trust and brainstorming mechanism for KSC scientists to invite and discuss new ideas and concepts. The advent of remote work and virtual platforms has allowed us to engage with interns in a new way that will continue as future interns are integrated into this network of individuals interested in space research. This work is funded by NASA’s Space Biology Program.

Internships↗

Continuous integration data-driven platform of industrial-scale subsurface storage for real-time analytics

This project helped address the growing need for efficient and scalable models to support geological carbon and energy storage, which are crucial for achieving net-zero emissions. Traditionally accurate high-fidelity numerical models have been used to simulate relevant storage processes under a handful of processes, however such models are computationally demanding, making uncertainty quantification impractical. Consequently, we first developed a machine learning framework, based on Graph Neural Operators (GNOs), to improving the accuracy of model predictions for a fixed computational budget. We then developed an Ensemble of Improved Neural Operators (ENO), which uses bagging and Monte Carlo dropout techniques, to further improve prediction accuracy. Lastly, we developed the way to explain progressive transfer learning methods to reduce the amount of training data and computational cost of training (i.e., reduce trainable parameters) when using our models for multiple storage sites. Our numerical investigation, which used real-world case studies, demonstrated that our framework can significantly improve the safety and efficiency of geological storage operations, with potential applications in other domains such as geothermal reservoirs and climate modeling.

54 ENVIRONMENTAL SCIENCES↗

Converged Computing: A Best of Both Worlds of High-Performance Computing and Cloud

Collaboration between Cloud and High Performance Computing (HPC) communities has accelerated in the last half decade. A common goal to run batch workloads combined with a desire for reproducibility, automation, and optimization has led to successful projects that range from container technologies to workload management and security. This span of current and future work defines a novel “Converged Computing” paradigm that aims to combine the best of both worlds, both from a technological and cultural standpoint. Furthermore, in this Special Issue, we review common themes in the space, showcasing current work and encouraging a continued effort toward innovative ideas that will enable the next generations of scientific discovery.

97 MATHEMATICS AND COMPUTING↗

Evaluating Offshore Infrastructure Integrity

Drilling in the offshore environment involves a complex network of infrastructure including pipelines, platforms, rigs, subsea installations, ports, and terminals. Government and industry partners have developed this network over many decades and it remains a critical part of the United States (U.S.) energy portfolio. Many of the major components of this system have been designed with a 20- to 30-year lifespan, yet consistent and growing energy demands support the need to extend the design life of existing infrastructure or repurpose it for secondary needs (i.e. enhanced oil recovery, carbon storage, and new wells). As a result, a growing portion of the offshore infrastructure in the U.S. is approaching or has exceeded its original design life. A critical step in ensuring the continued safe and effective operation of offshore infrastructure is developing a comprehensive understanding of the state of offshore infrastructure and the factors that effect it. The purpose of this project is to assess the current state of existing infrastructure and identify the factors involved in infrastructure degradation through the development and application of big data analytics, machine learning, and advanced spatio-temporal analysis. The project leverages existing data at NETL and combines it with new information on offshore oil and gas structures and the ambient offshore environment in an effort to identify patterns associated with infrastructure integrity. Building on the identified trends and patterns, this project incorporates exploratory analytics and spatial analysis tools in conjunction with machine learning and statistical models to characterize the condition of existing platforms in the offshore environment and predict their risk of failure.

02 PETROLEUM↗