Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computer Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Stabilized quasi-Newton optimization of noisy potential energy surfaces

Optimizations of atomic positions belong to the most commonly performed tasks in electronic structure calculations. Many simulations like global minimum searches or characterizations of chemical reactions require performing hundreds or thousands of minimizations or saddle computations. To automatize these tasks, optimization algorithms must not only be efficient but also very reliable. Unfortunately, computational noise in forces and energies is inherent to electronic structure codes. This computational noise poses a severe problem to the stability of efficient optimization methods like the limited-memory Broyden–Fletcher–Goldfarb–Shanno algorithm. We here present a technique that allows obtaining significant curvature information of noisy potential energy surfaces. We use this technique to construct both, a stabilized quasi-Newton minimization method and a stabilized quasi-Newton saddle finding approach. We demonstrate with the help of benchmarks that both the minimizer and the saddle finding approach are superior to comparable existing methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fault-tolerant linear optics quantum computation by error-detecting quantum state transfer

A scheme for linear optical implementation of fault-tolerant quantum computation is proposed, which is based on an error-detecting code. Each computational step is mediated by transfer of quantum information into an ancilla system embedding error-detection capability. Photons are assumed to be subjected to both photon loss and depolarization, and the threshold region of their strengths for scalable quantum computation is obtained, together with the amount of physical resources consumed. Compared to currently known results, the present scheme reduces the resource requirement, while yielding a comparable threshold region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of the BISON Multidimensional Fuel Performance Code

BISON is a modern multidimensional multiphysics finite-element based nuclear fuel performance code that has been under development at the Idaho National Laboratory (USA) since 2009. A brief background is provided on the code’s computational framework (MOOSE), governing equations, and material and behavioral models. Ongoing code verification and validation work is outlined, and comparative results are provided for select validation cases. Recent applications are discussed, including specific description of two applications where 3D treatment is important. A summary of future code development and validation activities is given. Numerous references to published work are provided where interested readers can find more complete information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Zebra: An advanced PWR lattice code

This paper presents an overview of an advanced PWR lattice code ZEBRA developed at NECP laboratory in Xi'an Jiaotong Univ.. The multi-group cross-section library is generated from the ENDF/B-VII library by NJOY and the 361-group SHEM structure is employed. The resonance calculation module is developed based on sub-group method. The transport solver is Auto-MOC code, which is a self-developed code based on the Method of Characteristic and the customization of AutoCAD software. The whole code is well organized in a modular software structure. Some numerical results during the validation of the code demonstrate that this code has a good precision and a high efficiency. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Update and Improve Subsection NH - Simplified Elastic and Inelastic Design Analysis Methods

The objective of this subtask is to develop a template for the 'Ideal' high temperature design Code, in which individual topics can be identified and worked on separately in order to provide the detail necessary to comprise a comprehensive Code. Like all ideals, this one may not be attainable as a practical matter. The purpose is to set a goal for what is believed the 'Ideal' design Code should address, recognizing that some elements are not mutually exclusive and that the same objectives can be achieved in different way. Most, if not all existing Codes may therefore be found to be lacking in some respects, but this does not mean necessarily that they are not comprehensive. While this subtask does attempt to list the elements which individually or in combination are considered essential in such a Code, the authors do not presume to recommend how these elements should be implemented or even, that they should all be implemented at all. The scope of this subtask is limited to compiling the list of elements thought to be necessary or at minimum, useful in such an 'Ideal' Code; suggestions are provided as to their relationship to one another. Except for brief descriptions, where these are needed for clarification, neither this repot, nor Task 9 as a whole, attempts to address details of the contents of all these elements. Some, namely primary load limits (elastic, limit load, reference stress), and ratcheting (elastic, e-p, reference stress) are dealt with specifically in other subtasks of Task 9. All others are merely listed; the expectation is that they will either be the focus of attention of other active DOE-ASME GenIV Materials Tasks, e.g. creep-fatigue, or to be considered in future DOE-ASME GenIV Materials Tasks. Since the focus of this Task is specifically approximate methods, the authors have deemed it necessary to include some discussion on what is meant by 'approximate'. However, the topic will be addressed in one or more later subtasks. This report describes work conducted toward developing a template for what might be the 'Ideal' high temperature design Code. While attempting to be as comprehensive as possible as to subject matter, it does not presume to recommend what individual components of a Code should be implemented, some of which is the focus of other Tasks in the DOE-ASME Gen IV/NGNP Materials Projects. This report does serve as a basis for construction of an attribute chart which is being prepared as part of Task 9.2; the intention for which is to provide a uniform format and concise means for summarizing and comparing other high temperature Codes currently in use around the world.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A regenerative multiple zone model for HCCI combustion

A new conserved scalar approach, the so-called regenerative multiple zone (RMZ) model, is introduced to simulate combustion in homogeneous charge compression ignition (HCCI) engines with significant products of combustion. In this approach, two conserved scalars are introduced, the mixture fraction Z and the initial exhaust gas fraction J, to determine uniquely the state of the reactive system as a function of the two conserved scalars and time. For the numerical solution of the HCCI combustion, the conserved scalar plane is divided into different zones, which represent homogeneous reactors with constant initial exhaust gas level. Particularly, the zones are created based on the distribution of the initial exhaust gases and are mixed and regenerated at every time step during combustion in order to account for the history effects which are due to the finite rate chemistry. A proper methodology to create and initialize the new zones during the combustion, the so-called zone creation strategy (ZCS), is also proposed. For validation, the RMZ model is implemented in the 2DRD code, which is a computational fluid dynamics code that solves the governing equations for a two-dimensional reaction-diffusion problem. Initially, the consistency of the new model is validated in a one-dimensional reaction-diffusion (RD) case. Subsequently, the necessity for a proper zone creation strategy is demonstrated by a two-dimensional RD case. Next, a parametric study is performed to investigate the sensitivity of the new model on the maximum number of zones that is used. Finally, the limitations as well as the advantages of the RMZ model are discussed. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multimodality Image Fusion and Planning and Dose Delivery for Radiation Therapy

Image-guided radiation therapy (IGRT) relies on the quality of fused images to yield accurate and reproducible patient setup prior to dose delivery. The registration of 2 image datasets can be characterized as hardware-based or software-based image fusion. Hardware-based image fusion is performed by hybrid scanners that combine 2 distinct medical imaging modalities such as positron emission tomography (PET) and computed tomography (CT) into a single device. In hybrid scanners, the patient maintains the same position during both studies making the fusion of image data sets simple. However, it cannot perform temporal image registration where image datasets are acquired at different times. On the other hand, software-based image fusion technique can merge image datasets taken at different times or with different medical imaging modalities. Software-based image fusion can be performed either manually, using landmarks, or automatically. In the automatic image fusion method, the best fit is evaluated using mutual information coefficient. Manual image fusion is typically performed at dose planning and for patient setup prior to dose delivery for IGRT. The fusion of orthogonal live radiographic images taken prior to dose delivery to digitally reconstructed radiographs will be presented. Although manual image fusion has been routinely used, the use of fiducial markers has shortened the fusion time. Automated image fusion should be possible for IGRT because the image datasets are derived basically from the same imaging modality, resulting in further shortening the fusion time. The advantages and limitations of both hardware-based and software-based image fusion methodologies are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulsed Neutron Powder Diffraction for Materials Science

The accelerator-based neutron diffraction began in the end of 60's at Tohoku University which was succeeded by the four spallation neutron facilities with proton accelerators at the High Energy Accelerator Research Organization (Japan), Argonne National Laboratory and Los Alamos Laboratory (USA), and Rutherford Appleton Laboratory (UK). Since then, the next generation source has been pursued for 20 years, and 1MW-class spallation neutron sources will be appeared in about three years at the three parts of the world: Japan, UK and USA. The joint proton accelerator project (J-PARC), a collaborative project between KEK and JAEA, is one of them. The aim of the talk is to describe about J-PARC and the neutron diffractometers being installed at the materials and life science facility of J-PARC. The materials and life science facility of J-PARC has 23 neutron beam ports and will start delivering the first neutron beam of 25 Hz from 2008 May. Until now, more than 20 proposals have been reviewed by the review committee, and accepted proposal groups have started to get fund. Those proposals include five polycrystalline diffractometers: a super high resolution powder diffractometer (SHRPD), a 0.2%-resolution powder diffractometer of Ibaraki prefecture (IPD), an engineering diffractometers (Takumi), a high intensity S(Q) diffractometer (VSD), and a high-pressure dedicated diffractometer. SHRPD, Takumi and IPD are being designed and constructed by the joint team of KEK, JAEA and Ibaraki University, whose member are originally from the KEK powder group. These three instruments are expected to start in 2008. VSD is a super high intensity diffractometer with the highest resolution of {delta}d/d = 0.3%. VSD can measure rapid time-dependent phenomena of crystalline materials as well as glass, liquid and amorphous materials. The pair distribution function will be routinely obtained by the Fourier transiformation of S(Q) data. Q range of VSD will be as wide as 0.01 A{sup -1}<Q<100 A{sup -1}. IPD is fully funded by Ibaraki prefecture for the promotion of new industries based on advanced science and technologies. It is for the first time in neutron facilities in Japan that a prefecture owns neutron instruments as well as neutron beam will be provided widely to industrial users. To make it successful, the user system is quite important because those users are expected to use IPD like chemical analyzers in their materials development process. Based on questionnaire data to several hundreds industries, IPD is designed as a versatile diffractometer including texture measurement, small angle scattering and total scattering as well as usual powder diffraction. IPD covers d range 0.15<d(A)<4 with {delta}d/d 0.15%, and covers 4<d(A)<60 with gradually changing resolution. Q range of IPD will be as wide as 0.01 A{sup -1}<Q<50A{sup -1} to be utilized for varieties of structures: local structure, nano structure and crystal structure analyses. Typical measuring time for the typical 'Rietveld-quality' data is several minutes with the sample size of laboratory X-ray: 0.4 cc. SHRPD is designed to be the world highest resolution with {delta}d/d = 0.03% without sacrificing intensity. The combination of the high quality data from HRPD and their high-precision analysis gives us information on tiny structural changes which have been overlooked. After careful examination with the moderator group five years ago, we have decided to develop a high-resolution and good S/N moderator to achieve the 0.03% resolution within 100 m flight path. This development was almost successful up to now. Instrumental simulation and radiation analysis were almost completed. The d range 0.5<d(A)<4 with {delta}d/d = 0.03%, and covers 4<d(A)<45 with gradually changing resolution. Takumi is the first priority instrument in JAEA for stress mapping inside structure materials with the highest resolution of {delta}d/d = 0.2% (corresponding to 10{approx}5 to 10{approx}6 strain precision). The typical gauge volume will be 1 mm3. JED has transmission radiography detectors to support stress mapping. Software group is planning so that basic software to cover data acquisition and data treatment should be common. Since 1 Gbyte data are typically obtained for single experiment in an instrument, the basic software is quite important. International TV conference between ISIS, IPNS, SNS has been held every month to exchange information on each development. KEK developed manyo-lib to help basic analysis. Analysis software development including powder diffraction is strongly related with the activity of the software group. However, users of IPD will be from various field of science and their background is different. It should cover wide topics and help both beginners and well-trained users. We have started with neutron intensity database, peak-search software, peak-match software, pattern simulation, whole pattern fitting, PDF and RDF analysis, and now start coding Rietveld software.

36 MATERIALS SCIENCE↗

The AMIDAS Website: An Online Tool for Direct Dark Matter Detection Experiments

Following our long-erm work on development of model-independent data analysis methods for reconstructing the one-dimensional velocity distribution function of halo WIMPs as well as for determining their mass and couplings on nucleons by using data from direct Dark Matter detection experiments directly, we combined the simulation programs to a compact system: AMIDAS (A Model-Independent Data Analysis System). For users' convenience an online system has also been established at the same time. AMIDAS has the ability to do full Monte Carlo simulations, faster theoretical estimations, as well as to analyze (real) data sets recorded in direct detection experiments without modifying the source code. In this article, I give an overview of functions of the AMIDAS code based on the use of its website.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-local transport in radiation-hydrodynamics codes for ICF by efficient coupling to an external Vlasov–Fokker–Planck code

Accurately incorporating non-local transport into radiation-hydrodynamics codes, and indeed any fluid system, has long been elusive. To date, a simplified and accurate theory that can be easily integrated has not been available. This limitation affects modeling in inertial confinement fusion (ICF) and magnetic confinement fusion systems, among others, where non-local transport is well-known to be present. Here, we present a coupling methodology between a full Vlasov–Fokker–Planck (VFP) electron kinetic code and radiation-hydrodynamics (rad-hydro) codes. The VFP code is used to adjust native electron transport in the rad-hydro code, thus enabling improved transport without the need to integrate a full electron VFP solver into the rad-hydro code. This approach necessitates only occasional invocation of the VFP code, reducing computational intensity compared to following the dynamic evolution entirely with the VFP code on fluid time scales. We illustrate that the methodology is more accurate than other simplified methods in thermal decay systems relevant to ICF and can replicate standard theoretical results with high accuracy.

Electronic transport↗

CHIANTI-AN ATOMIC DATABASE FOR EMISSION LINES. XIII. SOFT X-RAY IMPROVEMENTS AND OTHER CHANGES

The CHIANTI spectral code consists of two parts: an atomic database and a suite of computer programs in Python and IDL. Together, they allow the calculation of the optically thin spectrum of astrophysical objects and provide spectroscopic plasma diagnostics for the analysis of astrophysical spectra. The database includes atomic energy levels, wavelengths, radiative transition probabilities, collision excitation rate coefficients, ionization, and recombination rate coefficients, as well as data to calculate free-free, free-bound, and two-photon continuum emission. Version 7.1 has been released, which includes improved data for several ions, recombination rates, and element abundances. In particular, it provides a large expansion of the CHIANTI models for key Fe ions from Fe VIII to Fe XIV to improve the predicted emission in the 50-170 A wavelength range. All data and programs are freely available at http://www.chiantidatabase.org and in SolarSoft, while the Python interface to CHIANTI can be found at http://chiantipy.sourceforge.net.

79 ASTRONOMY AND ASTROPHYSICS↗

Code conversion with the quantum Golay code for a universal transversal gate set

The [[7,1,3]] Steane code and [[23,1,7]] quantum Golay code have been identified as good candidates for fault-tolerant quantum computing via code concatenation. These two codes have transversal implementations of all Clifford gates but require some other scheme for fault-tolerant T gates. Using magic states, Clifford operations, and measurements is one common scheme, but magic-state distillation can have a large overhead. Code conversion is one avenue for implementing a universal gate set fault tolerantly without the use of magic-state distillation. Analogously to how the [[7,1,3]] Steane code can be fault tolerantly converted to and from the [[15,1,3]] Reed-Muller code which has a transversal T gate, the [[23,1,7]] Golay code can be converted to a [[95,1,7]] triorthogonal code with a transversal T gate. Further, a crucial ingredient of this procedure is the [[49,1,5]] triorthogonal code, which can itself be seen as being related to the self-dual [[17,1,5]] two-dimensional color code. Additionally, a method for code conversion based on a transversal CNOT between the codes, rather than stabilizer measurements, is described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-124: FDG PET Metrics Analysis in the Context of An Adaptive PET Protocol for Node Positive Gynecologic Cancer Patients

Purpose: To compare PET extracted metrics and investigate the role of a gradient-based PET segmentation tool, PET Edge (MIM Software Inc., Cleveland, OH), in the context of an adaptive PET protocol for node positive gynecologic cancer patients. Methods: An IRB approved protocol enrolled women with gynecological, PET visible malignancies. A PET-CT was obtained for treatment planning prescribed to 45–50.4Gy with a 55– 70Gy boost to the PET positive nodes. An intra-treatment PET-CT was obtained between 30–36Gy, and all volumes re-contoured. Standard uptake values (SUVmax, SUVmean, SUVmedian) and GTV volumes were extracted from the clinician contoured GTVs on the pre- and intra-treament PET-CT for primaries and nodes and compared with a two tailed Wilcoxon signed-rank test. The differences between primary and node GTV volumes contoured in the treatment planning system and those volumes generated using PET Edge were also investigated. Bland-Altman plots were used to describe significant differences between the two contouring methods. Results: Thirteen women were enrolled in this study. The median baseline/intra-treatment primary (SUVmax, mean, median) were (30.5, 9.09, 7.83)/( 16.6, 4.35, 3.74), and nodes were (20.1, 4.64, 3.93)/( 6.78, 3.13, 3.26). The p values were all < 0.001. The clinical contours were all larger than the PET Edge generated ones, with mean difference of +20.6 ml for primary, and +23.5 ml for nodes. The Bland-Altman revealed changes between clinician/PET Edge contours to be mostly within the margins of the coefficient of variability. However, there was a proportional trend, i.e. the larger the GTV, the larger the clinical contours as compared to PET Edge contours. Conclusion: Primary and node SUV values taken from the intratreament PET-CT can be used to assess the disease response and to design an adaptive plan. The PET Edge tool can streamline the contouring process and lead to smaller, less user-dependent contours.

60 APPLIED LIFE SCIENCES↗

SU-E-J-146: A Research of PET-CT SUV Range for the Online Dose Verification in Carbon Ion Radiation Therapy

Purpose: Positron-emitting isotope distributions can be used for the image fusion of the carbon ion planning CT and online target verification PETCT, after radiation in the same decay period,the relationship between the same target volume and the SUV value of different every single fraction dose can be found,then the range of SUV for the radiation target could be decided.So this online range also can provide reference for the correlation and consistency in planning target dose verification and evaluation for the clinical trial. Methods: The Rando head phantom can be used as real body,the 10cc cube volume target contouring is done,beam ISO Center depth is 7.6cm and the 90 degree fixed carbon ion beams should be delivered in single fraction effective dose of 2.5GyE,5GyE and 8GyE.After irradiation,390 seconds later the 30 minutes PET-CT scanning is performed,parameters are set to 50Kg virtual weight,0.05mCi activity.MIM Maestro is used for the image processing and fusion,five 16mm diameter SUV spheres have been chosen in the different direction in the target.The average SUV in target for different fraction dose can be found by software. Results: For 10cc volume target,390 seconds decay period,the Single fraction effective dose equal to 2.5Gy,Ethe SUV mean value is 3.42,the relative range is 1.72 to 6.83;Equal to 5GyE,SUV mean value is 9.946,the relative range is 7.016 to 12.54;Equal or above to 8GyE,SUV mean value is 20.496,the relative range is 11.16 to 34.73. Conclusion: Making an evaluation for accuracy of the dose distribution using the SUV range which is from the planning CT with after treatment online PET-CT fusion for the normal single fraction carbon ion treatment is available.Even to the plan which single fraction dose is above 2GyE,in the condition of other parameters all the same,the SUV range is linearly dependent with single fraction dose,so this method also can be used in the hyper-fraction treatment plan.

60 APPLIED LIFE SCIENCES↗

WE-AB-201-02: TPS Commissioning and QA: A Process Orientation and Application of Control Charts

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG #5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗

WE-AB-201-03: TPS Commissioning and QA: Incorporating the Entire Planning Process

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG #5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗

Development of the TREAT M2 experiment as a transient benchmark

A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗