Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Novel Harsh Environment Materials and Fabrication Techniques for Wireless Sensor Applications (Final Report)

The overarching goal of this project is to establish a center of excellence program at the University of Maine that is focused on Harsh Environmental Materials and Fabrication Techniques for Wireless Sensor Applications. UMaine is well-positioned to build on previous successes in the areas of materials science research and sensor engineering. Since 1980, the Laboratory for Surface Science & Technology (LASST) has been a very successful interdisciplinary UMaine research center with a well-established infrastructure to investigate surfaces, interfaces, thin films, and micro/nano-fabrication. This infrastructure established through NSF, DOE, DOD, NASA, the State of Maine, and industry includes (i) a 3,500 ft2 clean room with nano/microfabrication and photolithography instrumentation, (ii) thin film synthesis, processing and characterization, (iii) surface and thin film analytical chemistry tools, and (iv) device packaging, electronic testing, wireless devices, system fabrication, and sensor test facilities. This strong foundation is the basis for a planned significant growth in R&D capacity currently underway. To that end, since the start of this project in the Fall of 2019, LASST has undergone a transition to become a new interdisciplinary center at UMaine, named the Frontier Institute for Research in Sensor Technologies (FIRST). This new focus represents a commitment and investment by UMaine that aligns with the proposed DOE-EPSCoR theme, capitalizing on the state-of-the-art instrumentation to form an energized group of faculty and students pursuing advances in sensor materials, devices, and applications.

36 MATERIALS SCIENCE↗

Fast Track Lunar NTR Systems Assessment for NASA's First Lunar Outpost and Its Evolvability to Mars

Integrated systems and missions studies are presented for an evolutionary lunar-to-Mars space transportation system (STS) based on nuclear thermal rocket (NTR) technology. A 'standardized' set of engine and stage components are identified and used in a 'building block' fashion to configure a variety of piloted and cargo, lunar and Mars vehicles. The reference NTR characteristics include a thrust of 50 thousand pounds force (klbf), specific impulse (I(sub sp)) of 900 seconds, and an engine thrust-to-weight ratio of 4. 3. For the National Aeronautics and Space Administrations (NASA) First Lunar Outpost (FLO) mission, and expendable NTR stage powered by two such engines can deliver approximately 96 metric tonnes (t) to trans-lunar injection (TLI) conditions for an initial mass in low Earth orbit (IMLEO) of approximately 198 t compared to 250 t for a cryogenic chemical system. The stage liquid hydrogen (LH2) tank has a diameter, length, and capacity of 10 m, 14.5 m and 66 t, respectively. By extending the stage length and LH2 capacity to approximately 20 m and 96 t, a single launch Mars cargo vehicle could deliver to an elliptical Mars parking orbit a 63 t Mars excursion vehicle (MEV) with a 45 t surface payload. Three 50 klbf engines and the two standardized LH2 tanks developed for the lunar and Mars cargo vehicles are used to configure the vehicles supporting piloted Mars missions as early as 2010. The 'modular' NTR vehicle approach forms the basis for an efficient STS able to handle the needs of a wide spectrum of lunar and Mars missions.

Borowski, Stanley K.↗

Fast analysis of molecular dynamics trajectories with graphics processing units-Radial distribution function histogramming

The calculation of radial distribution functions (RDFs) from molecular dynamics trajectory data is a common and computationally expensive analysis task. The rate limiting step in the calculation of the RDF is building a histogram of the distance between atom pairs in each trajectory frame. Here we present an implementation of this histogramming scheme for multiple graphics processing units (GPUs). The algorithm features a tiling scheme to maximize the reuse of data at the fastest levels of the GPU's memory hierarchy and dynamic load balancing to allow high performance on heterogeneous configurations of GPUs. Several versions of the RDF algorithm are presented, utilizing the specific hardware features found on different generations of GPUs. We take advantage of larger shared memory and atomic memory operations available on state-of-the-art GPUs to accelerate the code significantly. The use of atomic memory operations allows the fast, limited-capacity on-chip memory to be used much more efficiently, resulting in a fivefold increase in performance compared to the version of the algorithm without atomic operations. The ultimate version of the algorithm running in parallel on four NVIDIA GeForce GTX 480 (Fermi) GPUs was found to be 92 times faster than a multithreaded implementation running on an Intel Xeon 5550 CPU. On this multi-GPU hardware, the RDF between two selections of 1,000,000 atoms each can be calculated in 26.9 s per frame. The multi-GPU RDF algorithms described here are implemented in VMD, a widely used and freely available software package for molecular dynamics visualization and analysis.

97 MATHEMATICS AND COMPUTING↗

The Potential Role of Concentrating Solar Power within the Context of DOE's 2030 Solar Cost Targets

To continue the momentum for cost reduction in solar technologies, DOE recently established 2030 cost targets for that would make solar one of the lowest-cost sources of new electricity in the United States. The potential impacts of achieving the 2030 cost targets for solar photovoltaics (PV) were recently explored in a related publication, which found significant potential for solar PV deployment and generation, particularly when coupled with low-cost storage. Building on this previous report, the present analysis evaluates the potential impacts of simultaneously achieving the 2030 cost targets for both PV and concentrating solar power with thermal energy storage (CSP-TES) systems in the contiguous United States, with a detailed evaluation of the role that CSP-TES plays in realizing those impacts. The evolution of the contiguous U.S. electricity system is evaluated with NREL's Renewable Energy Deployment System (ReEDS) model, which has been specifically designed to represent the time and locational value of renewable generation technologies in the U.S. power system. This analysis suggests achievement of the SunShot cost targets for CSP-TES might lead to dramatic growth in CSP-TES capacity, with accelerated deployment after the 2030 target is achieved. Based on our representation of the 2030 cost targets in ReEDS, economically-competitive CSP-TES could primarily be deployed in a dispatch able, high-capacity factor configuration, which allows it to provide valuable services to the power sector and results in a generation profile for CSP-TES that is complementary to that of variable PV. Aggressive cost reductions for CSP-TES could also make such a configuration economically competitive across the contiguous United States, which is a a result that warrants additional analysis in terms of potential siting, permitting, regulatory, and construction challenges in these new regions and markets. The modeled capacity expansion of both CSP-TES and PV in our scenarios that achieve the 2030 cost targets requires most growth in transmission capacity at a pace that is consistent with historical buildout rates, and could result in reduced electricity prices and power system costs, water usage, and air emissions. Finally, sensitivity analysis suggests that the cumulative capacity and geographic extent of CSP-TES deployment in our low-cost solar scenarios is highly sensitive to the post-2030 cost reductions for CSP-TES and future price of natural gas, and that significant competition exists among renewable energy and energy storage technologies, assuming aggressive cost reductions for each. For example, significant competition between CSP-TES and PV with battery storage indicates the similar role that these systems play in capacity planning and grid operations, as well as the fact that low-cost battery storage would help improve the capacity value of low-cost PV into the future.

14 SOLAR ENERGY↗

Ionic Liquid-Assisted Synthesis of TiO 2 -Carbon Hybrid Nanostructures for Lithium-Ion Batteries

Building nanocomposite architectures based on nanocarbon materials (such as carbon nanotubes and graphene nanosheets) and metal-oxide nanoparticles is of great interests for electrochemical energy storage. Here, an ionic-liquid-assisted strategy is presented to mediate the in situ growth of TiO 2 nanocrystals with controlled size on carbon nanotubes and graphene, and also reduce the modified carbon supports to recover the graphitic structure simultaneously. The as-prepared nanocomposites exhibit a highly porous and robust structure with intimate coupling between TiO 2 nanocrystals and carbon supports, which offers facile ion and electron transport pathway as well as high mechanical stability. Finally, when evaluated as electrode materials for lithium-ion batteries, the nanocomposites manifest high specific capacity, long cycling lifetime, and excellent rate capability, showing their promising application in high-performance energy storage devices.

25 ENERGY STORAGE↗

Solid-State Fault Current Limiter Development: Design and Testing Update of a 15kV SSCL Power Stack

The Solid-State Fault Current Limiter (SSCL) is a promising technology that can be applied to utility power delivery systems to address the problem of increasing fault currents associated with load growth. As demand continues to grow, more power is added to utility system either by increasing generator capacity or by adding distributed generators, resulting in higher available fault currents, often beyond the capabilities of the present infrastructure. The SSCL is power-electronics based equipment designed to work with the present utility system to address this problem. The SSCL monitors the line current and dynamically inserts additional impedance into the line in the event of a fault being detected. The SSCL is based on a modular design and can be configured for 5kV through 69kV systems at nominal current ratings of 1000A to 4000A. Results and Findings This report provides the final test results on the development of 15kV class SSCL single phase power stack. The scope of work included the design of the modular standard building block sub-assemblies, the design and manufacture of the power stack and the testing of the power stack for the key functional tests of continuous current capability and fault current limiting action. Challenges and Objectives Solid-State Current Limiter technology impacts a wide spectrum of utility engineering and operating personnel. It addresses the problems associated with load growth both at Transmission and Distribution class networks. The design concept is pioneering in terms of developing the most efficient and compact power electronics equipment for utility use. The initial test results of the standard building blocks are promising. The independent laboratory tests of the power stack are promising. However the complete 3 phase system needs rigorous testing for performance and reliability. Applications, Values, and Use The SSCL is an intelligent power-electronics device which is modular in design and can provide current limiting or current interrupting capabilities. It can be applied to variety of applications from distribution class to transmission class power delivery grids and networks. It can also be applied to single major commercial and industrial loads and distributed generator supplies. The active switching of devices can be further utilized for protection of substation transformers. The stress on the system can be reduced substantially improving the life of the power system. It minimizes the voltage sag by speedy elimination of heavy fault currents and promises to be an important element of the utility power system. DOE Perspective This development effort is now focused on a 15kV system. This project will help mitigate the challenges of increasing available fault current. DOE has made a major contribution in providing a cost effective SSCL designed to integrate seamlessly into the Transmission and Distribution networks of today and the future. Approach SSCL development program for a 69kV SSCL was initiated which included the use of the Super GTO advanced semiconductor device which won the 2007 R&D100 Award. In the beginning, steps were identified to accomplish the economically viable design of a 69kV class Solid State Current Limiter that is extremely reliable, cost effective, and compact enough to be applied in urban transmission. The prime thrust in design and development was to encompass the 1000A and the 3000A ratings and provide a modular design to cover the wide range of applications. The focus of the project was then shifted to a 15kV class SSCL. The specifications for the 15kV power stack are reviewed. The design changes integrated into the 15kV power stack are discussed. In this Technical Update the complete project is summarized followed by a detailed test report. The power stack independent high voltage laboratory test requirements and results are presented. Keywords Solid State Current Limiter, SSCL, Fault Current Limiter, Fault Current Controller, Power electronics controller, Intelligent power-electronics Device, IED

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear Test Scenarios for Discussion of On-Site Inspection Technologies

The purpose of the ISS OSI Invited Meeting being held in Vienna March 24-27, 2009 is to obtain a better understanding of the phenomenology of underground nuclear explosions for On-Site Inspection (OSI) purposes. In order to focus the technology discussions, we have developed two very general scenarios, or models, of underground nuclear test configurations and phenomena that will help us explore the application of OSI methodologies and techniques. The scenarios describe testing environments, operations, logistics, equipment, and facilities that might be used in conducting an underground nuclear test. One scenario involves emplacement of a nuclear device into a vertical borehole in an area with relatively flat terrain; the other involves emplacement within a tunnel (horizontally) in an area with mountainous terrain. Vertical borehole geometry The example for this scenario is an intermediate yield nuclear explosion carried out in a flat desert area. The ground was cleared and smoothed over a 200 X 200 m fenced area for operational support activities, access to the borehole, and in order to place a few structures to house diagnostics equipment and control functions. Power lines were provided for local electrical power. The vertical emplacement borehole was 2 m in diameter and bored to a depth of 350 m. The emplacement hole was lined with steel pipe in order to keep the hole open and to avoid cave-ins during emplacement of the nuclear device. Emplacement was above the local water table, and the top of the saturation zone is about 30 m below the bottom of the emplacement hole. The detonation point was at a depth of 340 m. All of the rock material removed while drilling the borehole was removed to another place. Diagnostics and control for the test were relatively simple: about 2 dozen high capacity coaxial cables feed from the down hole instruments to the surface and then about 100 m laterally to a diagnostics trailer. Two strong steel cables were used to emplace the device and diagnostic instruments and to support the down hole cables. The borehole was stemmed after the device was emplaced. The stemming material was relatively simple: the hole was backfilled with sand or gravel about 20-30 m above the nuclear experiment package, a grouted plug about 3 m thick is added, and the hole backfilled with a mixture of sand and gravel to the surface. After the test, the testing party removed all structures and power lines and covered the top of the borehole with a small building. Geologic environment before the test--The geology for the test consists of flat-lying alluvium and tuff, with 50 m of poorly consolidated alluvium near the surface and moderately welded tuff from 50 m depth to 50 m below the bottom of the hole. The upper tuff is underlain by a densely welded tuff unit, with basement Paleozoic sedimentary rock beginning at a depth of about 1000 m. The tuff is intact with a few fractures. There are no known faults located within 500 m of the borehole. Alteration of the underground environment--The blast created a spherical or near spherical cavity with a lens of vitrified material at the bottom. There are several zones surrounding the detonation point with decreasing levels of rock damage. The zones are: (1) the crushed zone (several tens of meters)where the rock has lost all prior integrity; (2) the fractured zone (out to a couple of hundred meters) characterized by radial and concentric fissures; and (3) the zone of irreversible strain (out to a couple of thousand meters) with local media deformation. A collapse chimney formed one hour after the detonation, in which overlying material fell into the explosion cavity. This chimney zone reached up to within 50 m of the surface and a small apical void formed (10 m high and 80 m in diameter) at the top of the rubble chimney. The rubble chimney is dry and density is about 20% less than the surrounding intact rock. Alteration at the surface--No surface depression formed, but there is significant 'fluffing' of the surface soil from the effects of the initial shock wave. A few radial and concentric fractures formed from the shock effects within a radius of 200 m of the borehole. Radionuclide environment--No particulates or aerosol radiological material reached the surface. However, the stemming is not completely impervious to gas release and a small amount of gas and vapor was released along the emplacement pipe immediately after the explosion and before the rubble chimney formed. Most of the gas venting stopped as soon as cavity collapse occurred. After the rubble chimney formed and the pressure in the explosion cavity reached equilibrium, gases began to migrate up through the rubble chimney aided by barometric pumping. There is also an unknown fault located 300 m from the explosion cavity that provided another gas migration pathway between the damage zone of the cavity and the surface.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FINAL SCIENTIFIC REPORT Southwest United States of America – Distributed Technology Training Consortia (SWUSA-DTTC) Contract Number: DE-EE0006339

The Southwest United States of America – Distributed Technology Training Consortia (SWUSA-DTTC) leveraged the highest concentration of renewable resources in the U.S. as well as operation of the leading independent microgrid installations and other distributed technologies to collect and analyze real-time data streams, advance power system simulations and analysis, identify educational and training gaps and develop solutions-focused curricula. The SWUSA-DTTC consortium posed a unique collaboration between universities and utilities to ensure that classes were focused on subjects and topics of interest to the utilities and ones that had practical benefit related to the preparedness for accommodating high penetration of solar and other distributed energy technologies. This approach to have a close collaboration and shared effort to develop the course content and curriculum is unique and a significant departure from conventional course development. This coursework and training was intended to endure over a long time horizon (10-20 year time frame), and include professionals over the entire Southwest region and the rest of the US, and even outreach into foreign countries. Project Objectives In order to support the increase in power systems research, development, and analytical capacity, the SWUSA-DTTC brought together respected professors in Power Systems education, student/professor research and development, and valuable industry and utility experience. Through this program, the partnered universities created and/or modified existing curricula available to students and professionals in the form of university courses, short courses, videos, consortia-led training, and online materials. During this time, the supporting vendors and utilities provided the SWUSA-DTTC with technical advisory roles as well as providing input and feedback in terms of utility and related energy industry needs. The goals were to create power and energy systems training, curricula, and workforce preparedness through the inclusion of data collection and analysis, power systems expertise, and application-specific training activities which build on fundamental principles, modeling and simulation tools, field-immersed training and methods of performance validation. The outcome of the program was to result in better prepared and greater number of graduates ready to contribute to the field of power systems which depend upon the safe, reliable and efficient generation sources which make up an increasingly diverse mix of renewable power. Additionally, the program was to deliver critical training modules which are intended to support mid-career professionals and be woven into utility training programs used all over the country. Discontinuation Summary On September 29, 2014, Electricore received notice of discontinuation of federal funding under subject Award DE-EE0006339. DOE’s notice of discontinuation was the first indication provided to Electricore that the work completed against Task 1 - Program Planning and Evaluation during Budget Period 1 was inadequate. Significantly, the discontinuation was based in large part on the erroneous assertion that many of the tasks were incomplete as indicated in the Continuation Application. However, the Continuation Application was submitted July 29, 2014, while the period of performance for this last quarter in Budget Period 1 did not end until September 30, 2014. Accordingly, the performance for this last quarter in Budget Period 1 will be reported in the upcoming Quarterly Report which is not due until October 30, 2014. Nevertheless, in response to DOE’s letter and in further support of Electricore’s Continuation Application, we are providing a detailed status demonstrating adherence to all program requirements for each Task 1, Budget Period 1 SOPO activity and milestones in response to the DOE review.

14 SOLAR ENERGY↗

Laboratory Performance Evaluation of Residential Scale Gas Engine Driven Heat Pump

Building space cooling is, and until 2040 is expected to continue to be, the single largest use of electricity in the residential sector in the United States (EIA Energy Outlook 2015 .) Increases in electric-grid peak demand leads to higher electricity prices, system inefficiencies, power quality problems, and even failures. Thermally-activated systems, such as gas engine-driven heat pump (GHP), can reduce peak demand. This study describes the performance of a residential scale GHP. It was developed as part of a cooperative research and development agreement (CRADA) that was authorized by the Department of Energy (DOE) between OAK Ridge National Laboratory (ORNL) and Southwest Gas. Results showed the GHP produced 16.5 kW (4.7 RT) of cooling capacity at 35 C (95 F) rating condition with gas coefficient of performance (COP) of 0.99. In heating, the GHP produced 20.2 kW (5.75 RT) with a gas COP of 1.33. The study also discusses other benefits and challenges facing the GHP technology such as cost, reliability, and noise.

Abu-Heiba, Ahmad↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

ThermoLift – A Natural Gas Fired Air Conditioner and Heat Pump

ThermoLift is developing TC-Cycle™, a natural-gas driven air conditioner and cold-climate heat pump that can provide space heating, water heating, and air conditioning in a single device. Unlike traditional heat-pump system, the TC-Cycle system uses helium as working fluid in place of high global warming potential HFC refrigerant. The system has broad application as a combined HVAC solution and technology development throughout this program has advanced the Technology Readiness Level (TRL) from TRL-1 to TRL-5 achieved in the Gen 3.0 prototype. In August of 2013, the US Department of Energy (DOE) provided Research and Development funding through the Building Technologies Innovations Program Funding Opportunity Announcement DE-FOA-0000823. The statement of work (SOW) outlined a deliverable of testing at ORNL and a final test report prepared to include various heating cooling temperature ranges and performance analysis. Furthermore, a milestone of this effort was to analyze all test data to establish further efficiency improvements and consider optimum manufacturing methodologies to facilitate the next level improvements. ThermoLift’s Gen 3.0 gas-fired heat pump was shipped and installed into ORNL’s test facility with most of the data reported herein obtained on August 6, 2018. Uninterrupted operation demonstrated cycle Coefficient of Performance (COP) well exceeding DOE targets for cold-climate heat pumps. Furthermore, there was no degradation in capacity as inlet (ambient) temperature decreased.

03 NATURAL GAS↗

Meta-Analysis of Advanced Nuclear Reactor Cost Estimations

Supporting Data can be downloaded at: https://gain.inl.gov/content/uploads/4/2024/06/INL-RPT-24-77048-R1.xlsx Nuclear energy is a critical cornerstone of the current United States clean energy supply and may play a larger role in the future in support of a transition to a net-zero economy. The current fleet of nuclear reactors predominantly consists of large light-water reactors (LWRs), while many of the reactor designs under consideration are smaller and/or different technologies. Because these new designs have not yet been built, there is a high degree of uncertainty associated with their cost. This complicates energy-planning efforts because cost projections are not always standardized, consistent, and centralized in an easily accessible location. To help support energy planning in the US, this report provides advanced nuclear cost ranges using a transparent methodology along with other relevant information that can be used to help support decision making and energy planning. The purpose of this work was to conduct a methodical process for cost evaluation using only public information that was vetted with the end-goal to provide reference cost projections for nuclear energy. To provide a solid basis for these values, the approach and assumptions are explicitly laid out throughout the report allowing any user of the data to challenge or reconsider them. Because future US nuclear-reactor costs are still unknown due to little recent observed data, the report opted to compile a comprehensive list of bottom-up estimates and evaluate averages/trends within the data to identify reference ranges. This was deemed preferable to opining on the robustness or validity of one cost estimation versus another. To that end, the work evaluated thousands of lines of cost subaccounts from several bottom-up cost estimates. A wide variety of different reactor types captured in the data are of various sizes and technologies. Some of these reactors will be representative of advanced reactors under development while others will not. Thus, the results here are dependent on the data that are available and the accuracy of the estimates that are used. Each bottom-up estimate was reviewed to determine whether it was complete. Incomplete data sets were corrected to ensure an adequate basis of cross-comparison. The report is not without limitations and should be interpreted as an initial step to develop cost ranges for nuclear technology. Ultimately, future work can build upon the methodology with refined cost estimates to reduce uncertainty. US-based overnight capital cost (OCC) estimates were compiled from extensive data sets into ranges for both large and small reactor sizes for 2030. To project the cost declines over time, learning rates were sampled from literature sources. No SMRs were previously built; hence, learning rates based on bottom-up approaches (e.g., by quantifying the impact stemming from fabrication of different components, modular work, site construction, commissioning) were prioritized. For larger reactors, actual learning rates from deployments were used to project future costs (adjusted to account for standardization or lack thereof between designs). Other costs included are fixed and variable operations and maintenance costs. The final variables were capacity factors and ramp rates to support energy planning.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Living with high potassium: Balance between nutrient acquisition and K-induced salt stress signaling

High potassium (K) in the growth medium induces salinity stress in plants. However, the molecular mechanisms underlying plant responses to K-induced salt stress are virtually unknown. We examined Arabidopsis (Arabidopsis thaliana) and its extremophyte relative Schrenkiella parvula using a comparative multiomics approach to identify cellular processes affected by excess K and understand which deterministic regulatory pathways are active to avoid tissue damages while sustaining growth. Arabidopsis showed limited capacity to curb excess K accumulation and prevent nutrient depletion, contrasting to S. parvula which could limit excess K accumulation without restricting nutrient uptake. A targeted transcriptomic response in S. parvula promoted nitrogen uptake along with other key nutrients followed by uninterrupted N assimilation into primary metabolites during excess K-stress. This resulted in larger antioxidant and osmolyte pools and corresponded with sustained growth in S. parvula. Antithetically, Arabidopsis showed increased reactive oxygen species levels, reduced photosynthesis, and transcriptional responses indicative of a poor balance between stress signaling, subsequently leading to growth limitations. Furthermore, our results indicate that the ability to regulate independent nutrient uptake and a coordinated transcriptomic response to avoid nonspecific stress signaling are two main deterministic steps toward building stress resilience to excess K + -induced salt stress.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Evaluation of the ThermoLift Natural Gas Fired Air Conditioner and Cold-Climate Heat Pump

ThermoLift is currently developing its Thermal Compression Heat Pump (TCHP™), a natural-gas driven air conditioner and cold-climate heat pump, which can provide space heating, water heating, and air conditioning simultaneously in a single device. The system has broad application as a combined heating, ventilation, and air-conditioning (HVAC) solution with the benefit of substantial energy, cost, and greenhouse gas (GHG) reductions. Unlike traditional vapor compression heat-pumps, the TCHP™ uses helium as a working fluid in place of high global warming potential (GWP) refrigerants. The development effort has produced three iterations or generations of prototypes with advancement of the technology readiness level (TRL) from TRL-1 (TCHP™ Gen 1.0) to TRL-5 (TCHP™ Gen 3.0). In August of 2013, the US DOE solicited the submission of proposals through funding opportunity announcement DE-FOA-0000823, Building Technologies Innovations Program. The Office of Energy Efficiency and Renewable Energy (EERE) subsequently accepted ThermoLift’s proposal to develop a heat pump system based on the Hofbauer cycle, a new cycle that supplants the Vuilleumier cycle and provided funding for prototype evaluation at Oak Ridge National Laboratory (ORNL). ORNL is a widely known research center for developing and evaluating building technologies. Through its Building Technologies Research and Integration Center, ORNL has unique capabilities which allows them to collaborate with industry and academia to advance building component technologies. The TCHP™ Gen 3.0 prototype was shipped to ORNL on July 23, 2018. After installation and integration of the heat pump into ORNL’s test facility and performing instrumentation validation and calibration, extended operation of the heat pump was achieved during continuous operation on August 6, 2018, and includes various heating and cooling temperature ranges and performance analysis. The Gen 3.0 prototype was evaluated at four “ambient” temperatures: −25°C, −8.33°C, 8.33°C, and 20°C, (−13°F, 17°F, 47°F, and 68°F) denoted as test points 1-4, respectively. For heating, cycle coefficients of performance (COP) at the four “ambient” temperatures were found to be 1.30, 1.46, 1.52, and 1.61, respectively. Furthermore, there is no capacity reduction as the inlet temperature to the cold heat exchanger (HX) decreases. The heating capacity delivered by the TCHP was found to be 12 kW at -25°C. Finally, this final report identifies measures for obtaining further efficiency improvements.

42 ENGINEERING↗

Economic Development Benefits from Wind Energy in Nebraska: A Report for the Nebraska Energy Office (Revised)

This report focuses on the economic development impacts estimated from building and operating 7,800 MW of new wind power in Nebraska. This level of development is on the scale envisioned in the Department of Energy (DOE) report 20% Wind Energy by 2030. A practical first step to building 7,800 of wind is completing 1,000 MW. We also include the estimated economic impacts to Nebraska from building 1,000 MW of wind power. Our primary analysis indicates that the development and construction of approximately 7,800 MW of wind energy in Nebraska by 2030 will support 20,600 to 36,500 annual full-time equivalents (AFTE). In addition, operating the full 7,800 MW of wind energy could support roughly 2,000 to 4,000 full-time workers throughout the operating life of the wind facilities (LFTE). Nebraska's economy is estimated to see an average annual boost in economic activity ranging from $140 million to $260 million solely from construction and development related activities between 2011 and 2030. An additional boost of $250 - $442 million annually is estimated from operating 7,800 MW of wind capacity.

17 WIND ENERGY↗

Advanced Mirror Technology Development (AMTD) Project: 3.0 Year Status

Advanced Mirror Technology Development (AMTD) is a funded NASA Strategic Astrophysics Technology project. Begun in 2011, we are in Phase 2 of a multi-year effort. Our objective is to mature towards TRL6 critical technologies needed to produce 4-m or larger flight-qualified UVOIR mirrors by 2018 so that a viable astronomy mission can be considered by the 2020 Decadal Review. The developed technology must enable missions capable of both general astrophysics and ultra-high contrast observations of exoplanets. Just as JWST's architecture was driven by launch vehicle, a future UVOIR mission's architecture (monolithic, segmented or interferometric) will depend on capacities of future launch vehicles (and budget). Since we cannot predict the future, we must prepare for all potential futures. Therefore, we are pursuing multiple technology paths. AMTD uses a science-driven systems engineering approach. We mature technologies required to enable the highest priority science AND result in a high-performance low-cost low-risk system. One of our key accomplishments is that we have derived engineering specifications for advanced normal-incidence monolithic and segmented mirror systems needed to enable both general astrophysics and ultra-high contrast observations of exoplanets missions as a function of potential launch vehicle and its inherent mass and volume constraints. Another key accomplishment is that we have matured our technology by building and testing hardware. To demonstrate stacked core technology, we built a 400 mm thick mirror. Currently, to demonstrate lateral scalability, we are manufacturing a 1.5 meter mirror. To assist in architecture trade studies, the Engineering team develops Structural, Thermal and Optical Performance (STOP) models of candidate mirror assembly systems including substrates, structures, and mechanisms. These models are validated by test of full- and subscale components in relevant thermo-vacuum environments. Specific analyses include: maximum mirror substrate size, first fundamental mode frequency (i.e., stiffness) and mass required to fabricate without quilting, survive launch, and achieve stable pointing and maximum thermal time constant.

Stahl, H. Philip↗