Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARATIVE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Space shuttle orbit maneuvering engine reusable thrust chamber. Task 13: Subscale helium ingestion and two dimensional heating test report

Descriptions are given of the test hardware, facility, procedures, and results of electrically heated tube, channel and panel tests conducted to determine effects of helium ingestion, two dimensional conduction, and plugged coolant channels on operating limits of convectively cooled chambers typical of space shuttle orbit maneuvering engine designs. Helium ingestion in froth form, was studied in tubular and rectangular single channel test sections. Plugged channel simulation was investigated in a three channel panel. Burn-out limits (transition of film boiling) were studied in both single channel and panel test sections to determine 2-D conduction effects as compared to tubular test results.

Tobin, R. D.↗

Effect of creep in titanium alloy Ti-6Al-4V at elevated temperature on aircraft design and flight test

Short-term compressive creep tests were conducted on three titanium alloy Ti-6Al-4V coupons at three different stress levels at a temperature of 714 K (825 F). The test data were compared to several creep laws developed from tensile creep tests of available literature. The short-term creep test data did not correlate well with any of the creep laws obtained from available literature. The creep laws themselves did not correlate well with each other. Short-term creep does not appear to be very predictable for titanium alloy Ti-6Al-4V. Aircraft events that result in extreme, but short-term temperature and stress excursions for this alloy should be approached cautiously. Extrapolations of test data and creep laws suggest a convergence toward predictability in the longer-term situation.

Jenkins, J. M.↗

Thermal analysis of a hypersonic wing test structure

The three-dimensional finite element modeling techniques developed for the thermal analysis of a hypersonic wing test structure (HWTS) are described. The computed results are compared to measured test data. In addition, the results of a NASA two-dimensional parameter finite difference local thermal model and the results of a contractor two-dimensional lumped parameter finite difference local thermal model will be presented.

Sandlin, Doral R.↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests

high speed imaging↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests.

composite materials↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests.

Kohlman, Lee↗

Gas-Liquid Flows Through Porous Media in Microgravity: Packed Bed Reactor Experiment-2

Modifications were made to the Packed Bed Reactor Experiment (PBRE) and flown on the ISS as PBRE-2 to eliminate external pressure oscillations at higher liquid flow rates and the packing diameter was reduced to increase the pressure gradient for lower flows. It is found that gas hold-up is a function of bed history at low liquid and gas flow rates whereas higher gas hold-up and pressure gradients are observed for the test conditions following a liquid only pre-flow compared to the test conditions following a gas only pre-flow period. Over the range of flow rates tested, the capillary force is the dominant contributor to the pressure gradient, which is found to be linear with the superficial liquid velocity but is a much weaker function of the superficial gas velocity, and varying inversely with the particle diameter.

Mahsa Taghavi↗

A Comparison of Lifting-Line and CFD Methods with Flight Test Data from a Research Puma Helicopter

Four lifting-line methods were compared with flight test data from a research Puma helicopter and the accuracy assessed over a wide range of flight speeds. Hybrid Computational Fluid Dynamics (CFD) methods were also examined for two high-speed conditions. A parallel analytical effort was performed with the lifting-line methods to assess the effects of modeling assumptions and this provided insight into the adequacy of these methods for load predictions.

Bousman, William G.↗

Effect of Particle Damping on an Acoustically Excited Curved Vehicle Panel Structure with varied Equipment Assemblies

Particle dampers provide a mechanism for diverting energy away from resonant structural vibrations. This experimental study provides data from trials to determine how effective use of these dampers might be for equipment mounted to a curved orthogrid vehicle panel. Trends for damping are examined for variations in damper fill level, component mass, and excitation energy. A significant response reduction at the component level would suggest that comparatively small, thoughtfully placed, particle dampers might be advantageously used in vehicle design. The results of this test will be compared with baseline acoustic response tests and other follow-on testing involving a range of isolation and damping methods. Instrumentation consisting of accelerometers, microphones, and still photography data will be collected to correlate with the analytical results.

Parsons, David↗

WE-D-303-00: Computational Phantoms

Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems.

60 APPLIED LIFE SCIENCES↗

WE-D-303-01: Development and Application of Digital Human Phantoms

Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems.

60 APPLIED LIFE SCIENCES↗

Development of Mission Profiles for Humidity Models in the Reliability Testing of PV Inverters: Preprint

To understand the impacts of humidity on PV inverters, mission profiles were developed to accurately describe the different processes and rates based on the environmental factors of temperature, relative humidity, and irradiance. The operating environment of the device introduces stress factors dependent on component temperature, relative humidity, and component voltage. The development of profiles started from looking at historical climate conditions at Cocoa, Florida, a hot and humid location. The profile developed from field location was compared with existing humidity test profiles in industrial and military standards to determine acceleration factors. Prior to the evaluation of the mission profiles, critical components in the PV inverter were identified based on vendor discussions along with failure modes of interest. The profiles considered in this study was demonstrated using a 4-kVA string inverter. The measurements from the devices were substituted in device manufacturer specified equation to determine the severity of each test. The severity of each test was compared against the severity of the 24-hour result to determine the acceleration factor of each test. The acceleration factors were determined to be over a range of 1.2-6 for the existing humidity tests from standards, when compared against the mission profile developed from field data. This optimal humidity/thermal profile will be passed to the IEC standards development for inverter qualification testing.

humidity models↗

Test Beam Results of 3D Silicon Pixel Sensors for the ATLAS upgrade

Results on beam tests of 3D silicon pixel sensors aimed at the ATLAS Insertable-B-Layer and High Luminosity LHC (HL-LHC) upgrades are presented. Measurements include charge collection, tracking efficiency and charge sharing between pixel cells, as a function of track incident angle, and were performed with and without a 1.6 T magnetic field oriented as the ATLAS Inner Detector solenoid field. Sensors were bump bonded to the front-end chip currently used in the ATLAS pixel detector. Full 3D sensors, with electrodes penetrating through the entire wafer thickness and active edge, and double-sided 3D sensors with partially overlapping bias and read-out electrodes were tested and showed comparable performance. Full and partial 3D pixel detectors have been tested, with and without a 1.6T magnetic field, in high energy pion beams at the CERN SPS North Area in 2009. Sensors characteristics have been measured as a function of the beam incident angle and compared to a regular planar pixel device. Overall full and partial 3D devices have similar behavior. Magnetic field has no sizeable effect on 3D performances. Due to electrode inefficiency 3D devices exhibit some loss of tracking efficiency for normal incident tracks but recover full efficiency with tilted tracks. As expected due to the electric field configuration 3D sensors have little charge sharing between cells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative performance with direct and geared engines

Comprehensive tests were made to compare the performance of the F-5-L Boat Seaplane fitted with direct drive and Liberty engines. Details are given on the test conditions. The conclusions of the comparison tests follow. 1) An F-5-L with geared engines takes off in approximately 90 percent of the time required for the same airplane with standard direct drive engines. An F-5-L with geared engines climbs in 20 minutes to an altitude approximately 20 percent greater than that obtained with the standard direct drive on the same airplane. 3) There is a large difference between the climbs of the two airplanes of the same type. This difference will always be more pronounced when the climb is normally slow. In the case of the F-5-L airplanes under construction, it is of the order of a 10 percent difference in altitude on a 20 minute climb. 4) The maximum speed of an F-5-L with geared engines is about 3.5 percent greater than the maximum speed of the same airplane with standard direct drive engines (at the same engine r.p.m.). 5) The fuel consumption is probably less effected by the type of drive than by inherent differences in the performance of different airplanes.

Diehl, W S↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

Test Cases for Modeling and Validation of Structures with Piezoelectric Actuators

A set of benchmark test articles were developed to validate techniques for modeling structures containing piezoelectric actuators using commercially available finite element analysis packages. The paper presents the development, modeling, and testing of two structures: an aluminum plate with surface mounted patch actuators and a composite box beam with surface mounted actuators. Three approaches for modeling structures containing piezoelectric actuators using the commercially available packages: MSC/NASTRAN and ANSYS are presented. The approaches, applications, and limitations are discussed. Data for both test articles are compared in terms of frequency response functions from deflection and strain data to input voltage to the actuator. Frequency response function results using the three different analysis approaches provided comparable test/analysis results. It is shown that global versus local behavior of the analytical model and test article must be considered when comparing different approaches. Also, improper bonding of actuators greatly reduces the electrical to mechanical effectiveness of the actuators producing anti-resonance errors.

Reaves, Mercedes C.↗

Monte Carlo Simulation of Sudden Death Bearing Testing

Monte Carlo simulations combined with sudden death testing were used to compare resultant bearing lives to the calculated hearing life and the cumulative test time and calendar time relative to sequential and censored sequential testing. A total of 30 960 virtual 50-mm bore deep-groove ball bearings were evaluated in 33 different sudden death test configurations comprising 36, 72, and 144 bearings each. Variations in both life and Weibull slope were a function of the number of bearings failed independent of the test method used and not the total number of bearings tested. Variation in L10 life as a function of number of bearings failed were similar to variations in lift obtained from sequentially failed real bearings and from Monte Carlo (virtual) testing of entire populations. Reductions up to 40 percent in bearing test time and calendar time can be achieved by testing to failure or the L(sub 50) life and terminating all testing when the last of the predetermined bearing failures has occurred. Sudden death testing is not a more efficient method to reduce bearing test time or calendar time when compared to censored sequential testing.

Vlcek, Brian L.↗