Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Structure–function relationships for squid skin-inspired wearable thermoregulatory materials

Wearable thermoregulatory technologies have attracted widespread attention because of their potential for impacting individual physiological comfort and for reducing building energy consumption. Within this context, the study of materials and systems that can merge the advantageous characteristics of both active and passive operating modes has proven particularly attractive. Accordingly, our laboratory has drawn inspiration from the appearance-changing skin of Loliginidae (inshore squids) for the introduction of a unique class of dynamic thermoregulatory composite materials with outstanding figures of merit. Herein, we demonstrate a straightforward approach for experimentally controlling and computationally predicting the adaptive infrared properties of such bioinspired composites, thereby enabling the development and validation of robust structure–function relationships for the composites. Our findings may help unlock the potential of not only the described materials but also comparable systems for applications as varied as thermoregulatory wearables, food packaging, infrared camouflage, soft robotics, and biomedical sensing.

Liu, Panyiming (ORCID:0000000242223670)↗

Prediction of hemiwicking dynamics in micropillar arrays

Dynamic hemiwicking behavior is observable in both nature and a wide range of industrial applications ranging from biomedical devices to thermal management. We present a semi-analytical modeling framework (without empirical fitting coefficients) to predict transient capillary-driven hemiwicking behavior of a liquid through a nano/microstructured surface, specifically a micropillar array. In our model framework, the liquid domain is discretized into micropillar unit cells to enable the time marching of the hemiwicking front. A simplified linear pressure drop is assumed along the hemiwicking length such that the local meniscus curvature, contact angle, and effective liquid height are determined at each time step in our transient model. This semi-analytical model is validated with experimental data from our own experiments and from published literature for different fluids. Our model predicts hemiwicking dynamics with <20% error over a broad range of micropillar geometries with height-to-pitch ratio ranging between ≈0.34 and 6.7 and diameter-to-pitch ratio in the range of ≈0.25–0.7 and without any fitting parameters. For lower diameter-to-pitch ratio data points related to sparse micropillar array arrangements, we suggest modifications to the semi-analytical model. This work sheds light on complex and dynamic solid–liquid–vapor interfacial interactions which could serve as a guide for the design of textured surfaces for wicking enhancement in multi-phase thermal and mass transport technologies and applications.

Mechanics↗

Engineering advancements in microfluidic systems for enhanced mixing at low Reynolds numbers

Mixing within micro- and millichannels is a pivotal element across various applications, ranging from chemical synthesis to biomedical diagnostics and environmental monitoring. The inherent low Reynolds number flow in these channels often results in a parabolic velocity profile, leading to a broad residence time distribution. Achieving efficient mixing at such small scales presents unique challenges and opportunities. This review encompasses various techniques and strategies to evaluate and enhance mixing efficiency in these confined environments. It explores the significance of mixing in micro- and millichannels, highlighting its relevance for enhanced reaction kinetics, homogeneity in mixed fluids, and analytical accuracy. We discuss various mixing methodologies that have been employed to get a narrower residence time distribution. The role of channel geometry, flow conditions, and mixing mechanisms in influencing the mixing performance are also discussed. Various emerging technologies and advancements in microfluidic devices and tools specifically designed to enhance mixing efficiency are highlighted. We emphasize the potential applications of micro- and millichannels in fields of nanoparticle synthesis, which can be utilized for biological applications. Additionally, the prospects of machine learning and artificial intelligence are offered toward incorporating better mixing to achieve precise control over nanoparticle synthesis, ultimately enhancing the potential for applications in these miniature fluidic systems.

Biochemistry & Molecular Biology↗

Plasma–liquid interactions in the presence of organic matter—A perspective

As investigations in the biomedical applications of plasma advance, a demand for describing safe and efficacious delivery of plasma is emerging. It is quite clear that not all plasmas are “equal” for all applications. This Perspective discusses limitations of the existing parameters used to define plasma in context of the need for the “right plasma” at the “right dose” for each “disease system.” The validity of results extrapolated from in vitro studies to preclinical and clinical applications is discussed. We make a case for studying the whole system as a single unit, in situ. Furthermore, we argue that while plasma-generated chemical species are the proposed key effectors in biological systems, the contribution of physical effectors (electric fields, surface charging, dielectric properties of target, changes in gap electric fields, etc.) must not be ignored.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond wavelength-tunable laser system using gain managed nonlinear amplifier

Optical parametric amplifiers require a seed energy at the spectral range of interest for amplification. In the case of pulsed laser systems, seed pulse characteristics such as spectral energy density and spectral uniformity influence laser system design and performance. In this letter, we present the design and modeling of a few micro-joules, wavelength-tunable, femtosecond parametric amplifier system. We employ a gain-managed nonlinear fiber amplifier output as the seed pulse. This seed pulse is relatively uniform across its bandwidth from 1010 to 1180 nm. Its spectral energy density averages 600 pJ/nm, 30 times higher than conventional counterparts. The overall amplification gain is 175, and the conversion efficiency is 17.5%. The inherent quasi-linear chirp of the seed pulse is utilized to alter the output wavelength. Our tunable femtosecond laser is an enabling technology for high-demand applications such as time-resolved spectroscopy, nonlinear and advanced material research, and biomedical imaging and microscopy modalities.

47 OTHER INSTRUMENTATION↗

The mechanism of hydroxyapatite coatings degradation at high substrate temperatures

Physical vapor deposition methods used for hydroxyapatite (HA) coatings typically require elevated substrate temperatures and post-deposition annealing to induce crystallization. However, such thermal treatments can degrade both the mechanical integrity and bioactivity of the coating, particularly when substrate temperatures exceed 500 °C. The mechanisms underlying these phenomena remain insufficiently understood. In this study, HA thin films were deposited on silicon and Ti6Al4V substrates using pulsed laser deposition and were systematically characterized to elucidate these mechanisms. XPS and SIMS analyses revealed a temperature-dependent loss of OH − and PO 4 3− groups, an increased Ca/P ratio, and the formation of interfacial oxides, all of which contribute to weakened adhesion. To clarify the temperature-dependent decline in bioactivity, protein adsorption behavior was analyzed using a Kramers-type kinetic framework; the fitted desorption kinetics indicate that coatings deposited near ∼500 °C provide the most stable protein attachment, whereas higher temperatures accelerate desorption due to dehydroxylation and carbonate substitution. Together, these findings provide mechanistic insight into the thermal degradation of HA coatings and offer a framework for optimizing deposition parameters to preserve stoichiometry, adhesion, and bioactivity for long-term biomedical applications.

Kylychbekov, Salizhan [Univ. of Oxford (United Kin↗

Effects of annealing temperature on the magnetic properties of highly crystalline biphase iron oxide nanorods

We report on the effects of annealing temperatures ranging from 225 °C to 325 °C on the magnetic properties of high aspect ratio iron oxide nanorods consisting of a ferrimagnetic Fe 3 O 4 phase and an antiferromagnetic α-Fe 2 O 3 phase in an as-prepared state. Annealing at the aforementioned temperatures under a constant flow of O 2 for 3 h leads to an increment of the volume fraction of the antiferromagnetic α-Fe 2 O 3 phase and concomitant enhancement of the crystallinity of the ferrimagnetic Fe 3 O 4 phase. These opposing effects compete with each other, resulting in a decrease in global magnetization with increasing the annealing temperature. The desirable magnetic properties are achieved for the sample annealed at 250 °C. For all samples investigated, we observed an increase in low field magnetization at low temperatures after the sample is field cooled in the presence of a 1T magnetic field, which we attribute to the ordering of macro-spins of the weakly ordered antiferromagnetic α-Fe 2 O 3 phase in the presence of the cooling field. Our study will pave the way for determining the optimal conditions to enhance the magnetic characteristics in iron oxide nanorods, which will enable its use in spintronics and biomedical applications.

36 MATERIALS SCIENCE↗

Dynamic ultramicroscopy of laser-induced flows in colloidal solutions of plasmon-resonance particles

A method is proposed for visualisation of the velocity fields of colloidal plasmon-resonance nanoparticles moving in a laser beam. The method uses the particle image velocimetry for processing ultramicroscopic images. Particles in a thick layer of colloidal solution are illuminated by a slit laser ultramicroscopic source with a large numerical aperture providing a high contrast of particle images and visualisation of the transverse velocity distribution in laser-induced flows with a high spatial resolution. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algebraic reconstruction and postprocessing in one-step diffuse optical tomography

The photon average trajectory method is considered, which is used as an approximate method of diffuse optical tomography and is based on the solution of the Radon-like trajectory integral equation. A system of linear algebraic equations describing a discrete model of object reconstruction is once inverted by using a modified multiplicative algebraic technique. The blurring of diffusion tomograms is eliminated by using space-varying restoration and methods of nonlinear colour interpretation of data. The optical models of the breast tissue in the form of rectangular scattering objects with circular absorbing inhomogeneities are reconstructed within the framework of the numerical experiment from optical projections simulated for time-domain measurement technique. It is shown that the quality of diffusion tomograms reconstructed by this method is close to that of tomograms reconstructed by using Newton-like multistep algorithms, while the computational time is much shorter. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shadow noise in OCT images of biological tissues

Optical coherence tomography (OCT) images of turbid medium with spatially fluctuating optical parameters demonstrate the presence of spatial noise ('shadow noise') caused by shading of the observed layer by variations in scattering and absorption coefficients of superficial layers. In this paper we report the development of the theoretical model of shadow noise in OCT images in which the features for discriminating this type of noise from the noise of a different origin are determined. Shadow noise is discovered in OCT images of biological tissue after specific image processing and the validity of the developed theoretical model is proven. The role of shadow noise as an interfering factor at imaging the variations in the backscattering coefficient, as well as the source of extra information on optical characteristics of the medium is analysed. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of multiple scattering in formation of OCT skin images

Optical coherence tomography (OCT) images of model human skin samples are obtained by using Monte Carlo simulations. The contributions of least and multiple scattering, diffusion and nondiffusion components and of separate scattering orders are studied by using a multilayer skin model based on experimental images. The model images are obtained by neglecting speckles or taking them into account. It is shown that least scattering forms the image of the upper skin layers, while the contribution of multiple scattering can be characterised as a blurred full image with a lower contrast. Repeated scattering mainly contributes to the OCT image at depths up to 1 mm. The diffusion component contributes to the image beginning from the epidermal basal layer. The partial image produced by this component is more blurred compared to the partial image produced by to multiple scattering. The nondiffusion component forms the OCT skin image at depths up to {approx}1.3 mm. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the artificial neural network for reconstructing the internal-structure image of a random medium by spatial characteristics of backscattered optical radiation

The feasibility of using an artificial neural network (ANN), which is the standard Matlab tool, for non-invasive (based on the data of backscattering) diagnostics of macro-inhomogeneities, localised at subsurface layers of the turbid strongly scattering medium was shown. The spatial and angle distribution of the backscattered optical radiation was calculated by using the Monte-Carlo method combining the modelling of effective optical paths and the use of statistical weights. It was shown that application of the backscattering method together with the ANN allows solving inverse problems for determining the average radius of the scattering particles and for reconstructing the images of structural elements within the medium with a high accuracy. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for remote diagnostics of the internal structure of layered media

The method of autocorrelation low coherence interferometry is proposed for diagnostics of inhomogeneities and the internal structure of layered technical and biological samples. In this method the low coherence optical field reflected from the layered sample is analysed by using a Michelson interferometer. Because the object is outside the interferometer, the distance between the interferometer and the object under study is not limited and thus the object can move during the measurements. Theoretical substantiation of the autocorrelation method for media with discrete and continuous optical structure modifications is presented. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser photothermolysis of biological tissues by using plasmon-resonance particles

The spatial temperature distribution in biological tissues upon interaction of laser radiation with plasmon-resonance nanoparticles is simulated numerically. Experimental thermograms of model objects and real biological tissues are obtained in vivo for different localisation depths of nanoparticles in different irradiation regimes. The results obtained in the study can be used for the development of methods of laser photothermolysis of malignant tumours. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Application of laser speckles for identification of tissues with pathological changes

Two new techniques for the analysis of speckle-patterns, formed by laser radiation dispersed on histological sections with malignant and non-malignant growths, are proposed. One of these techniques is based on the calculation of invariant Zernike moments of the spatial distribution of the speckle-field intensity. The second technique is based on the calculation of the fractal dimension of the intensity spatial distribution in the speckle structure. It is shown that both these methods yield the same results, which drastically depend on tissue properties. The possibility of using Zernike moments and fractal dimensions, formed by laser light dispersed on histological sections, in in vitro express-diagnostics of tissues with pathological changes is investigated. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

60 APPLIED LIFE SCIENCES↗

Diagnostics of pigmented skin tumors based on laser-induced autofluorescence and diffuse reflectance spectroscopy

Results of investigation of cutaneous benign and malignant pigmented lesions by laser-induced autofluorescence spectroscopy (LIAFS) and diffuse reflectance spectroscopy (DRS) are presented. The autofluorescence of human skin was excited by a 337-nm nitrogen laser. A broadband halogen lamp (400-900 nm) was used for diffuse reflectance measurements. A microspectrometer detected in vivo the fluorescence and reflectance signals from human skin. The main spectral features of benign (dermal nevi, compound nevi, dysplastic nevi) and malignant (melanoma) lesions are discussed. The combined usage of the fluorescence and reflectance spectral methods to determine the type of the lesion, which increases the total diagnostic accuracy, is compared with the usage of LIAFS or DRS only. We also applied colorimetric transformation of the reflectance spectra detected and received additional evaluation criteria for determination of type of the lesion under study. Spectra from healthy skin areas near the lesion were detected and changes between healthy and lesion skin spectra were revealed. The influence of the main skin pigments on the detected spectra is discussed and evaluation of possibilities for differentiation between malignant and benign lesions is performed based on their spectral properties. This research shows that the non-invasive and high-sensitive in vivo detection by means of appropriate light sources and detectors should be possible, related to the real-time determination of existing pathological conditions. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Possibility of increasing the efficiency of laser-induced tattoo removal by optical skin clearing

The possibility of selective laser photothermolysis improvement for the removal of tattoo pigments due to the optical clearing of human skin is investigated. It is shown experimentally that the optical skin clearing increases the tattoo image contrast. Computer Monte Carlo simulations show that by decreasing the laser beam scattering in upper skin layers, it is possible to reduce the radiation power required for tattoo removal by 30%-40% and, therefore, to increase the the photothermolysis efficiency. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ray-wave approximation for calculating laser radiation scattering by a transparent dielectric spheroidal particle

A theoretical model is developed and an algorithm is proposed for calculating far-field light scattering by a transparent dielectric particle significantly larger than a wavelength. The accuracy of this algorithm is close to that of the discrete dipole approximation. The calculation time for this algorithm in the case of particles with the size parameter higher than 50 is much lower than that for the discrete dipole approximation. Scattering diagrams for spheroidal particles of different sizes, orientations and refractive indices are calculated. The proposed algorithm has a great potential for quick calculations of parameters of light scattering by large biological particles such as erythrocytes and their aggregates, bacteria, etc. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗