Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bandwidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Investigation of terahertz sheet beam traveling wave tube amplifier with nanocomposite cathode

Particle-in-cell simulations of a staggered double grating array traveling wave tube intended as a wideband amplifier for terahertz communications, sensing, and imaging applications showed that, for an electron beam power of 5 kW, it produces 150-275 W, corresponding to 3%-5.5% electronic efficiency, at 0.22 THz with over {approx}30% bandwidth and with greater than 12 dB/cm growth rate. The circuit has been fabricated by both UV lithography and high precision computer-numerical-control machining with {approx}2-3 {mu}m dimensional tolerance and {approx}50 nm surface roughness. A scandate nanocomposite (Sc{sub 2}O{sub 3}-W) cathode for the electron beam source has successfully emitted 120 A/cm{sup 2} (space charge limited) at 1150 deg. C and 50 A/cm{sup 2} at 1050 deg. C for 8000 h as required to produce the requisite high current density electron beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Er{sup 3+} 1.53 {mu}m luminescence by CeF{sub 3} nanocrystallization in aluminosilicate glass

In order to develop promising materials for the Er{sup 3+}-doped fiber amplifier, transparent glass ceramics containing hexagonal CeF{sub 3} nanocrystals were prepared by melt-quenching and subsequent heating. The obvious Stark splitting in the absorption and emission spectra, the intensification of the 1.53 {mu}m emission, and the prolongation of the Er{sup 3+}:{sup 4}I{sub 13/2} decay lifetime demonstrated the partition of Er{sup 3+} ions into the CeF{sub 3} nanocrystals. Evidently, the efficient cross-relaxation between Ce{sup 3+} and Er{sup 3+}, i.e., Er{sup 3+}:{sup 4}I{sub 11/2}+Ce{sup 3+}:{sup 2}F{sub 5/2}{yields}Er{sup 3+}:{sup 4}I{sub 13/2}Ce{sup 3+}:{sup 2}F{sub 7/2} led to the quenching of the upconversion and the enhancing of the desired Er{sup 3+} 1.53 {mu}m emission. Based on the emission and absorption spectra, it was further calculated that the glass ceramic possesses broad bandwidth as that of the ZBLAN glass, and large emission cross-section close to the silicate glass, for the 1.53 {mu}m emission.

36 MATERIALS SCIENCE↗

Microdischarge extreme ultraviolet source with alkali metal vapor for surface morphology application

We have characterized a discharge-produced potassium plasma extreme ultraviolet (XUV) source. Potassium ions produced strong broadband emission around 40 nm with a bandwidth of 8 nm (full width at half-maximum). By comparison with atomic structure calculations, the broadband emission is found to be primarily due to 3d-3p transitions in potassium ions ranging from K{sup 2+} to K{sup 4+}. The current-voltage characteristics of the microdischarge suggest that the source operates in a hollow cathode mode and consequently the emitting ions may be localized on the potassium electrode surface at the hole into the capillary. To understand the spectral behavior from the potassium plasmas we compared the spectra from the discharge-produced plasma with that from a laser-produced plasma. The spectra from the different (electric and laser) plasmas at the same electron temperature (12 eV) were almost the same. This compact capillary XUV source with a photon energy of 30 eV is a useful XUV emission source for surface morphology applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modified Fowler-Milne method for the spectroscopic determination of thermal plasma temperature without the measurement of continuum radiation

A technique based on the Fowler-Milne method for the spectroscopic determination of thermal plasma temperatures without measuring continuum radiation is presented. This technique avoids the influence of continuum radiation with the combined line and continuum emission coefficients to derive the plasma temperatures. The amount of continuum emission coefficient is estimated by using an expression related to the Biberman factors. Parameters that affect the accuracy of the proposed technique and errors in the measured plasma temperatures are analyzed. It is shown that, by using the Ar I 696.5 nm line with a bandwidth of 3.27 nm without taking into account the continuum radiation, the plasma temperature measured will be lower on the order of up to 1000-3000 K for temperatures from 20 000 to 24 000 K. The theoretically predicted temperature errors are in good agreement with the experimental results, indicating that the proposed technique is reliable for plasma temperature measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Naphthacene Based Organic Thin Film Transistor With Rare Earth Oxide

Naphthacene based organic thin film transistors (OTFTs) have been fabricated using La{sub 2}O{sub 3}, as the gate insulator. All the OTFTs have been fabricated by the process of thermal evaporation in vacuum on perfectly cleaned glass substrates with aluminium as source-drain and gate electrodes. The naphthacene film morphology on the glass substrate has been studied by XRD and found to be polycrystalline in nature. The field effect mobility, output resistance, amplification factor, transconductance and gain bandwidth product of the OTFTs have been calculated by using theoretical TFT model. The highest value of field effect mobility is found to be 0.07x10{sup -3} cm{sup 2}V{sup -1}s{sup -1} for the devices annealed in vacuum at 90 deg. C for 5 hours.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-dimensional theory of weakly nonlinear Compton scattering

Nonlinear effects are known to occur in light sources when the wiggler parameter, or normalized 4-potential, A=e{radical}(-A{sub {mu}}A{sup {mu}})/m{sub 0}c, approaches unity. In this paper, it is shown that nonlinear spectral features can appear at arbitrarily low values of A if the fractional bandwidth of the undulator, {Delta}{phi}{sup -1}, is sufficiently small and satisfies the condition A{sup 2{Delta}{phi}{approx}}1. Consequences for the spectral brightness of Compton scattering light sources are outlined. Compton and Thomson scattering theories are compared with the Klein-Nishina cross-section formula to highlight differences in the case of narrow band gamma-ray operation. A weakly nonlinear Compton scattering theory is developed in one (plane wave) and three (local plane wave approximation) dimensions. Analytical models are presented and benchmarked against numerical calculations solving the Lorentz force equation with a fourth-order Runge-Kutta algorithm. Finally, narrow band gamma-ray spectra are calculated for realistic laser and electron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integrated microfluidic chip with 40 MHz lead-free transducer for fluid analysis

The design, fabrication, and evaluation of a high-frequency transducer made from lead-free piezoceramic for the application of microfluidic analysis is described. Barium strontium zirconate titanate [(Ba{sub 0.95}Sr{sub 0.05})(Zr{sub 0.05}Ti{sub 0.95})O{sub 3}, abbreviated as BSZT] ceramic has been chosen to be the active element of the transducer. The center frequency and bandwidth of this high-frequency ultrasound transducer have been measured to be 43 MHz and 56.1%, respectively. The transducer was integrated into a microfluidic channel and used to measure the sound velocity and attenuation of the liquid flowing in the channel. Results suggest that lead-free high-frequency transducers could be used for in situ analysis of property of the fluid flowing through the microfluidic system.

36 MATERIALS SCIENCE↗

A new method for wideband characterization of resonator-based sensing platforms

A new approach to the electronic instrumentation for extracting data from resonator-based sensing devices (e.g., microelectromechanical, piezoelectric, electrochemical, and acoustic) is suggested and demonstrated here. Traditionally, oscillator-based circuitry is employed to monitor shift in the resonance frequency of the resonator. These circuits give a single point measurement at the frequency where the oscillation criterion is met. However, the resonator response itself is broadband and contains much more information than a single point measurement. Here, we present a method for the broadband characterization of a resonator using white noise as an excitation signal. The resonator is used in a two-port filter configuration, and the resonator output is subjected to frequency spectrum analysis. The result is a wideband spectral map analogous to the magnitude of the S21 parameters of a conventional filter. Compared to other sources for broadband excitation (e.g., frequency chirp, multisine, or narrow time domain pulse), the white noise source requires no design of the input signal and is readily available for very wide bandwidths (1 MHz-3 GHz). Moreover, it offers simplicity in circuit design as it does not require precise impedance matching; whereas such requirements are very strict for oscillator-based circuit systems, and can be difficult to fulfill. This results in a measurement system that does not require calibration, which is a significant advantage over oscillator circuits. Simulation results are first presented for verification of the proposed system, followed by measurement results with a prototype implementation. A 434 MHz surface acoustic wave (SAW) resonator and a 5 MHz quartz crystal microbalance (QCM) are measured using the proposed method, and the results are compared to measurements taken by a conventional bench-top network analyzer. Maximum relative differences in the measured resonance frequencies of the SAW and QCM resonators are 0.0004% and 0.002%, respectively. The ability to track a changing sensor response is demonstrated by inducing temperature variations and measuring resonance frequency simultaneously using the proposed technique in parallel with a network analyzer. The relative difference between the two measurements is about 5.53 ppm, highlighting the impressive accuracy of the proposed system. Using commercially available digital signal processors (DSPs), we believe that this technique can be implemented as a system-on-a-chip solution resulting in a very low cost, easy to use, portable, and customizable sensing system. In addition, given the simplicity of the signal and circuit design, and its immunity to other common interface concerns (injection locking, oscillator interference, and drift, etc.), this method is better suited to accommodating array-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezoresistive cantilever force-clamp system

We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements and modeling of Alfven eigenmode induced fast ion transport and loss in DIII-D and ASDEX Upgrade

Neutral beam injection into reversed magnetic shear DIII-D and ASDEX Upgrade plasmas produces a variety of Alfvenic activity including toroidicity-induced Alfven eigenmodes and reversed shear Alfven eigenmodes (RSAEs). These modes are studied during the discharge current ramp phase when incomplete current penetration results in a high central safety factor and increased drive due to multiple higher order resonances. Scans of injected 80 keV neutral beam power on DIII-D showed a transition from classical to AE dominated fast ion transport and, as previously found, discharges with strong AE activity exhibit a deficit in neutron emission relative to classical predictions. By keeping beam power constant and delaying injection during the current ramp, AE activity was reduced or eliminated and a significant improvement in fast ion confinement observed. Similarly, experiments in ASDEX Upgrade using early 60 keV neutral beam injection drove multiple unstable RSAEs. Periods of strong RSAE activity are accompanied by a large (peak {delta}S{sub n}/S{sub n{approx_equal}}60%) neutron deficit. Losses of beam ions modulated at AE frequencies were observed using large bandwidth energy and pitch resolving fast ion loss scintillator detectors and clearly identify their role in the process. Modeling of DIII-D loss measurements using guiding center following codes to track particles in the presence of ideal magnetohydrodynamic (MHD) calculated AE structures (validated by comparison to experiment) is able to reproduce the dominant energy, pitch, and temporal evolution of these losses. While loss of both co and counter current fast ions occurs, simulations show that the dominant loss mechanism observed is the mode induced transition of counter-passing fast ions to lost trapped orbits. Modeling also reproduces a coherent signature of AE induced losses and it was found that these coherent losses scale proportionally with the amplitude; an additional incoherent contribution scales quadratically with the mode amplitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High speed nano-metrology

For manufacturing at the nanometre scale a method for rapid and accurate measurement of the resultant functional devices is required. Although atomic force microscopy (AFM) has the requisite spatial resolution, it is severely limited in scan speed, the resolution and repeatability of vertical and lateral measurements being degraded when speed is increased. Here we present a new approach to AFM that makes a direct and feedback-independent measurement of surface height using a laser interferometer focused onto the back of the AFM tip. Combining this direct height measurement with a passive, feedback-free method for maintaining tip-sample contact removes the constraint on scan speed that comes from the bandwidth of the z-feedback loop. Conventional laser reflection detection is used for feedback control, which now plays the role of minimising tip-sample forces, rather than producing the sample topography. Using the system in conjunction with a rapid scanner, true height images are obtained with areas up to (36 x 36) {mu}m{sup 2} at 1 image/second, suitable for in-line applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-performance metamorphic InGaAs resonant cavity enhanced photodetector grown on GaAs substrate

In this letter, we demonstrated a top illuminated 1.55 {mu}m metamorphic InGaAs resonant-cavity-enhanced p-i-n photodetector grown on GaAs substrate. The photodetectors were grown by a solid-source molecular beam epitaxy system. The high quality linearly graded In{sub x}Al{sub 0.4}Ga{sub 1-x-0.4}As metamorphic buffer layer enabled photodiodes to achieve ultralow dark current densities of 2.3x10{sup -6} A/cm{sup 2} at 0 V and 4.2x10{sup -5} A/cm{sup 2} at a reverse bias of 5 V. A high quantum efficiency of 84.4% at resonant wavelength of 1542 nm, a full width at half maximum about 14 nm, and a -3 dB bandwidth up to 13 GHz were also obtained.

36 MATERIALS SCIENCE↗

A versatile low-temperature setup for the electrical characterization of single-molecule junctions

We present a modular high-vacuum setup for the electrical characterization of single molecules down to liquid helium temperatures. The experimental design is based on microfabricated mechanically controllable break junctions, which offer control over the distance of two electrodes via the bending of a flexible substrate. The actuator part of the setup is divided into two stages. The slow stage is based on a differential screw drive with a large bending range. An amplified piezoceramic actuator forms the fast stage of the setup, which can operate at bending speeds of up to 800 {mu}m/s. In our microfabricated break junctions this is translated into breaking speeds of several 10 nm/s, sufficient for the fast acquisition of large statistical datasets. The bandwidth of the measurement electronics has been optimized to enable fast dI/dV spectroscopy on molecular junctions with resistances up to 100 M{Omega}. The performance of the setup is demonstrated for a {pi}-conjugated oligo(phenylene-ethynylene)-dithiol molecule.

36 MATERIALS SCIENCE↗

Femtosecond broadband fluorescence upconversion spectroscopy: Improved setup and photometric correction

A setup for fluorescence upconversion spectroscopy (FLUPS) is described which has 80 fs temporal response (fwhm) for emission in the spectral range 425-750 nm. Broadband phase matching is achieved with tilted gate pulses at 1340 nm. Background from harmonics of the gate pulse is removed and sensitivity increased compared to previous designs. Photometric calibration of the upconversion process is performed with a set of fluorescent dyes. For Coumarin 153 in methanol the peak position, bandwidth, and asymmetry depending on delay time are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed two-dimensional optical beam position detector

Disclosed is the design of a high speed two-dimensional optical beam position detector which outputs the X and Y displacement and total intensity linearly. The experimental detector measures the displacement from DC to 123 MHz and the intensity of an optical spot in a similar way as a conventional quadrant photodiode detector. The design uses four discrete photodiodes and simple dedicated optics for the position decomposition which enables higher spatial accuracy and faster electronic processing than conventional detectors. Measurements of the frequency response and the spatial sensitivity demonstrate high suitability for atomic force microscopy, scanning probe data storage applications, and wideband wavefront sensing. The operation principle allows for position measurements up to 20 GHz and more in bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-loss rate of a fast particle in graphene

The energy-loss rate of a fast particle in graphene is studied. The energy-loss rate always increases with increasing incident particle energy, which is quite unusual when compared to electron gas in normal metal. Graphene exhibits a ''discriminating'' behavior where there exists a low energy cut-off below which the scattering process is strictly forbidden, leading to lossless traverse of an external particle in graphene. This low energy cutoff is of the order of nearest neighbor hopping bandwidth. Our results suggest that backscattering is also absent in the external particle scattering of graphene.

36 MATERIALS SCIENCE↗

Particle simulation of a ka-band gyrotron traveling wave amplifier

The design of a ka-band gyrotron traveling wave (gyro-TWT) amplifier is presented. The gyro-TWT amplifier with a severed structure operates in the fundamental harmonic TE{sub 01} circular electric mode. The beam-wave interaction is studied by using a particle-in-cell (PIC) code. The simulations predict that the amplifier can produce an output peak power of over 155 kW, 22% efficiency, 23 dB gain, and a 3 dB bandwidth of 2 GHz for a 70 kV, 10 A electron beam with an axial velocity spread {Delta}v{sub z}/v{sub z}=5%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of Multilayer Monochromators for Hard X-Ray Imaging with Coherent Synchrotron Radiation

We present a study in which multilayers of different periodicity (from 2.5 to 5.5 nm), composition (W/Si, Mo/Si, Pd/B{sub 4}C, Ru/B{sub 4}C), and numbers of layers have been compared. Particularly, we chose mirrors with similar intrinsic quality (roughness and reflectivity) to study their performance (flatness and coherence of the outgoing beam) as monochromators in synchrotron radiography. The results indicate that material composition is the dominating factor for the performance. This is important to consider for future developments in synchrotron-based hard x-ray imaging methods. In these techniques, multilayer monochromators are popular because of their good tradeoff between spectral bandwidth and photon flux density of the outgoing beam, but sufficient homogeneity and preservation of the coherent properties of the reflected beam are major concerns. The experimental results we collected may help scientists and engineers specify multilayer monochromators and can contribute to better exploitation of the advantages of multilayer monochromators in microtomography and other full-field imaging techniques.

43 PARTICLE ACCELERATORS↗