AutoSynGrid: A MATLAB-based toolkit for automatic generation of synthetic power grids
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Purpose: Auto-propagation of anatomic regions of interest from the planning computed tomography (CT) scan to the daily CT is an essential step in image-guided adaptive radiotherapy. The goal of this study was to quantitatively evaluate the performance of the algorithm in typical clinical applications. Methods and Materials: We had previously adopted an image intensity-based deformable registration algorithm to find the correspondence between two images. In the present study, the regions of interest delineated on the planning CT image were mapped onto daily CT or four-dimensional CT images using the same transformation. Postprocessing methods, such as boundary smoothing and modification, were used to enhance the robustness of the algorithm. Auto-propagated contours for 8 head-and-neck cancer patients with a total of 100 repeat CT scans, 1 prostate patient with 24 repeat CT scans, and 9 lung cancer patients with a total of 90 four-dimensional CT images were evaluated against physician-drawn contours and physician-modified deformed contours using the volume overlap index and mean absolute surface-to-surface distance. Results: The deformed contours were reasonably well matched with the daily anatomy on the repeat CT images. The volume overlap index and mean absolute surface-to-surface distance was 83% and 1.3 mm, respectively, compared with the independently drawn contours. Better agreement (>97% and <0.4 mm) was achieved if the physician was only asked to correct the deformed contours. The algorithm was also robust in the presence of random noise in the image. Conclusion: The deformable algorithm might be an effective method to propagate the planning regions of interest to subsequent CT images of changed anatomy, although a final review by physicians is highly recommended.
Purpose: To compare interobserver variations in delineating the whole breast for treatment planning using two contouring methods. Methods and Materials: Autosegmented contours were generated by a deformable image registration-based breast segmentation method (DEF-SEG) by mapping the whole breast clinical target volume (CTVwb) from a template case to a new patient case. Eight breast radiation oncologists modified the autosegmented contours as necessary to achieve a clinically appropriate CTVwb and then recontoured the same case from scratch for comparison. The times to complete each approach, as well as the interobserver variations, were analyzed. The template case was also mapped to 10 breast cancer patients with a body mass index of 19.1-35.9 kg/m{sup 2}. The three-dimensional surface-to-surface distances and volume overlapping analyses were computed to quantify contour variations. Results: The median time to edit the DEF-SEG-generated CTVwb was 12.9 min (range, 3.4-35.9) compared with 18.6 min (range, 8.9-45.2) to contour the CTVwb from scratch (30% faster, p = 0.028). The mean surface-to-surface distance was noticeably reduced from 1.6 mm among the contours generated from scratch to 1.0 mm using the DEF-SEG method (p = 0.047). The deformed contours in 10 patients achieved 94% volume overlap before correction and required editing of 5% (range, 1-10%) of the contoured volume. Conclusion: Significant interobserver variations suggested a lack of consensus regarding the CTVwb, even among breast cancer specialists. Using the DEF-SEG method produced more consistent results and required less time. The DEF-SEG method can be successfully applied to patients with different body mass indexes.
Purpose: Accurate contouring of positron emission tomography (PET) functional volumes is now considered crucial in image-guided radiotherapy and other oncology applications because the use of functional imaging allows for biological target definition. In addition, the definition of variable uptake regions within the tumor itself may facilitate dose painting for dosimetry optimization. Methods and Materials: Current state-of-the-art algorithms for functional volume segmentation use adaptive thresholding. We developed an approach called fuzzy locally adaptive Bayesian (FLAB), validated on homogeneous objects, and then improved it by allowing the use of up to three tumor classes for the delineation of inhomogeneous tumors (3-FLAB). Simulated and real tumors with histology data containing homogeneous and heterogeneous activity distributions were used to assess the algorithm's accuracy. Results: The new 3-FLAB algorithm is able to extract the overall tumor from the background tissues and delineate variable uptake regions within the tumors, with higher accuracy and robustness compared with adaptive threshold (T{sub bckg}) and fuzzy C-means (FCM). 3-FLAB performed with a mean classification error of less than 9% +- 8% on the simulated tumors, whereas binary-only implementation led to errors of 15% +- 11%. T{sub bckg} and FCM led to mean errors of 20% +- 12% and 17% +- 14%, respectively. 3-FLAB also led to more robust estimation of the maximum diameters of tumors with histology measurements, with <6% standard deviation, whereas binary FLAB, T{sub bckg} and FCM lead to 10%, 12%, and 13%, respectively. Conclusion: These encouraging results warrant further investigation in future studies that will investigate the impact of 3-FLAB in radiotherapy treatment planning, diagnosis, and therapy response evaluation.
Purpose: Assuming that early tumor volume change is a biomarker for response to therapy, accurate quantification of early volume changes could aid in adapting an individual patient's therapy and lead to shorter clinical trials. We investigated an image registration-based approach for tumor volume change quantification that may more reliably detect smaller changes that occur in shorter intervals than can be detected by existing algorithms. Methods and Materials: Variance and bias of the registration-based approach were evaluated using retrospective, in vivo, very-short-interval diffusion magnetic resonance imaging scans where true zero tumor volume change is unequivocally known and synthetic data, respectively. The interval scans were nonlinearly registered using two similarity measures: mutual information (MI) and normalized cross-correlation (NCC). Results: The 95% confidence interval of the percentage volume change error was (-8.93% to 10.49%) for MI-based and (-7.69%, 8.83%) for NCC-based registrations. Linear mixed-effects models demonstrated that error in measuring volume change increased with increase in tumor volume and decreased with the increase in the tumor's normalized mutual information, even when NCC was the similarity measure being optimized during registration. The 95% confidence interval of the relative volume change error for the synthetic examinations with known changes over {+-}80% of reference tumor volume was (-3.02% to 3.86%). Statistically significant bias was not demonstrated. Conclusion: A low-noise, low-bias tumor volume change measurement algorithm using nonlinear registration is described. Errors in change measurement were a function of tumor volume and the normalized mutual information content of the tumor.
Purpose: To perform a rigorous technological assessment and statistical validation of a software technology for anatomic delineations of the prostate on MRI datasets. Methods and Materials: A 3-phase validation strategy was used. Phase I consisted of anatomic atlas building using 100 prostate cancer MRI data sets to provide training data sets for the segmentation algorithms. In phase II, 2 experts contoured 15 new MRI prostate cancer cases using 3 approaches (manual, N points, and region of interest). In phase III, 5 new physicians with variable MRI prostate contouring experience segmented the same 15 phase II datasets using 3 approaches: manual, N points with no editing, and full autosegmentation with user editing allowed. Statistical analyses for time and accuracy (using Dice similarity coefficient) endpoints used traditional descriptive statistics, analysis of variance, analysis of covariance, and pooled Student t test. Results: In phase I, average (SD) total and per slice contouring time for the 2 physicians was 228 (75), 17 (3.5), 209 (65), and 15 seconds (3.9), respectively. In phase II, statistically significant differences in physician contouring time were observed based on physician, type of contouring, and case sequence. The N points strategy resulted in superior segmentation accuracy when initial autosegmented contours were compared with final contours. In phase III, statistically significant differences in contouring time were observed based on physician, type of contouring, and case sequence again. The average relative timesaving for N points and autosegmentation were 49% and 27%, respectively, compared with manual contouring. The N points and autosegmentation strategies resulted in average Dice values of 0.89 and 0.88, respectively. Pre- and postedited autosegmented contours demonstrated a higher average Dice similarity coefficient of 0.94. Conclusion: The software provided robust contours with minimal editing required. Observed time savings were seen for all physicians irrespective of experience level and baseline manual contouring speed.
Purpose: To incorporate a novel imaging sequence for robust air and tissue segmentation using ultrashort echo time (UTE) phase images and to implement an innovative synthetic CT (synCT) solution as a first step toward MR-only radiation therapy treatment planning for brain cancer. Methods and Materials: Ten brain cancer patients were scanned with a UTE/Dixon sequence and other clinical sequences on a 1.0 T open magnet with simulation capabilities. Bone-enhanced images were generated from a weighted combination of water/fat maps derived from Dixon images and inverted UTE images. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating segmentation errors (true-positive rate, false-positive rate, and Dice similarity indices using CT simulation (CT-SIM) as ground truth. The synCTs were generated using a voxel-based, weighted summation method incorporating T2, fluid attenuated inversion recovery (FLAIR), UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized Hounsfield unit (HU) differences between synCT and CT-SIM. A dosimetry study was conducted, and differences were quantified using γ-analysis and dose-volume histogram analysis. Results: On average, true-positive rate and false-positive rate for the CT and MR-derived air masks were 80.8% ± 5.5% and 25.7% ± 6.9%, respectively. Dice similarity indices values were 0.78 ± 0.04 (range, 0.70-0.83). Full field of view MAE between synCT and CT-SIM was 147.5 ± 8.3 HU (range, 138.3-166.2 HU), with the largest errors occurring at bone–air interfaces (MAE 422.5 ± 33.4 HU for bone and 294.53 ± 90.56 HU for air). Gamma analysis revealed pass rates of 99.4% ± 0.04%, with acceptable treatment plan quality for the cohort. Conclusions: A hybrid MRI phase/magnitude UTE image processing technique was introduced that significantly improved bone and air contrast in MRI. Segmented air masks and bone-enhanced images were integrated into our synCT pipeline for brain, and results agreed well with clinical CTs, thereby supporting MR-only radiation therapy treatment planning in the brain.
Not Available
Not Available
In this work we present an efficient strategy to deal with plasma physics simulations in which localized departures from thermodynamical equilibrium are present. The method is based on the introduction of intermediate regions which allows smooth transitions between kinetic and fluid zones. In this paper we extend Domain Decomposition techniques, obtained through dynamic coupling and buffer zones, to the study of plasmas and, moreover, we combine them with Asymptotic Preserving and Asymptotically Accurate strategies for the time integration. We use a hybrid scheme in which both kinetic and fluid descriptions are considered and coupled together while the kinetic model is solved by asymptotic preserving and accurate methods, in order to guarantee high efficiency and accuracy in all regimes. The numerical scheme is validated and its performances are analyzed by numerical simulations.
Explore the source record for details and available documents.
Not Available
Void formation is an important aspect of irradiation response of metals. In situ transmission electron microscopy observation for void evolution during irradiation is an effective technique for studying void evolution. However, the amount of data collected during in situ studies drastically overwhelm the current capability for manual data analyses. Here, we used a data-driven approach where a convolutional neural network combined with greedy matching to detect and track nanovoid evolutions and migrations. This approach was able to discover the surprising phenomena of void size fluctuation and shrinkage during irradiation of Cu with pre-existing nanovoids. Phase–field simulations revealed the fundamental mechanism behind this in situ observed phenomenon of void size fluctuation.
The prediction of the climate system is highly depended on the efficient integration of observations and simulations of the Earth. This is regarded as a canonical example of the cyber-physical system. The climate system model, the simulation engine in this cyber-physical system, is one of most challenging applications in scientific computing. It utilizes the multi-physics simulation that couples multiple components, conducts decadal to millennium simulations, and has long been an important application on supercomputers. However, current climate system models suffer from the inefficient task scheduling methods resulting in an intolerable simulation time. Take the Community Earth System Model (CESM), the most widely used climate system model, as an example, one major reason that CESM suffers from bad performances is the huge overhead to rationally distribute processes among the coupled heterogeneous components. According to the report of NCAR, every percent improvement in CESM performance frees up to the equivalent of $250,000 in computing resources in their scientific experiments. To address such challenge, our paper firstly constructs a lightweight and accurate performance model for effectively capturing and predicting the heterogeneous time-to-solution performance of end-to-end CESM components with a given simulation configuration. Then, based on the performance model, we further propose an efficient scheduling strategy based on rectangular packing method to determine the best process layout among different components, and the process numbers assigned to each component. Our evaluations show that we can achieve 58% average run time reductions on CESM comparing to the widely used sequential process layout for a scale of 144 to 480 cores on typical CPU clusters. And we can save 4 million CPU hours when we conduct one standard scientific experiment (a 2870-year simulation), which equals to save $40,089 with a charge of $0.01 per CPU hour. Meanwhile, 26% extra performance improvements could also be gained in our methods comparing to the heuristic branch and bound algorithm with the guidance of the known curve-fitting performance model.
Not Available