Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Dynamically weighted multireference perturbation theory: Combining the advantages of multi-state and state-averaged methods

In this paper, we introduce two new approaches to compute near-degenerate electronic states based on the driven similarity renormalization group (DSRG) framework. The first approach is a unitary multi-state formalism based on the DSRG (MS-DSRG), whereby an effective Hamiltonian is built from a set of state-specific solutions. The second approach employs a dynamic weighting parameter to smoothly interpolate between the multi-state and the state-averaged DSRG schemes. The resulting dynamically weighted DSRG (DW-DSRG) theory incorporates the most desirable features of both multi-state approaches (ability to accurately treat many states) and state-averaged methods (correct description of avoided crossings and conical intersections). We formulate second-order perturbation theories (PT2) based on the MS- and DW-DSRG and study the potential energy curves of LiF, the conical intersection of the two lowest singlet states of NH 3 , and several low-lying excited states of benzene, naphthalene, and anthracene. The DW-DSRG-PT2 predicts the correct avoided crossing of LiF and avoids artifacts produced by the corresponding state-specific and multi-state theories. Excitation energies of the acenes computed with the DW-DSRG-PT2 are found to be more accurate than the corresponding state-averaged values, showing a small dependence on the number of states computed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the angular dependence of the spontaneous Raman scattering in anisotropic crystalline materials using spherical samples: Potassium dihydrogen phosphate as a case example

A specialized experimental configuration was created to allow for more-accurate characterization of the spontaneous Raman scattering properties in anisotropic materials. This need stems from the challenges, arising from the complexity of light propagation, in obtaining accurate measurements of the angular dependence of the Raman scattering cross section in birefringent materials. The nonlinear optical material KH 2 PO 4 (KDP) is used as a model medium. Our report is motivated by the need to improve our understanding and management of transverse stimulated Raman scattering in KDP crystals and its deuterated analog, DKDP, typically used for frequency conversion and polarization control in large-aperture laser systems. Key to this experimental platform is the use of high-quality spherical samples that enable one to measure the Raman scattering cross section in a wide range of geometries using only a single sample. The effect of polarization rotation of both the pump light and the collected Raman signal must be carefully considered in data analysis and can give rise to artifacts, which can, in part, be mitigated by reducing the input and collection cone angles.

47 OTHER INSTRUMENTATION↗

Scattering off molecules far from equilibrium

We report that pump-probe gas phase X-ray scattering experiments, enabled by the development of X-ray free electron lasers, have advanced to reveal scattering patterns of molecules far from their equilibrium geometry. While dynamic displacements reflecting the motion of wavepackets can probe deeply into the reaction dynamics, in many systems, the thermal excitation embedded in the molecules upon optical excitation and energy randomization can create systems that encompass structures far from the ground state geometry. For polyatomic molecular systems, large amplitude vibrational motions are associated with anharmonicity and shifts of interatomic distances, making analytical solutions using traditional harmonic approximations inapplicable. More generally, the interatomic distances in a polyatomic molecule are not independent and the traditional equations commonly used to interpret the data may give unphysical results. Here, we introduce a novel method based on molecular dynamic trajectories and illustrate it on two examples of hot, vibrating molecules at thermal equilibrium. When excited at 200 nm, 1,3-cyclohexadiene (CHD) relaxes on a subpicosecond time scale back to the reactant molecule, the dominant pathway, and to various forms of 1,3,5-hexatriene (HT). With internal energies of about 6 eV, the energy thermalizes quickly, leading to structure distributions that deviate significantly from their vibrationless equilibrium. The experimental and theoretical results are in excellent agreement and reveal that a significant contribution to the scattering signal arises from transition state structures near the inversion barrier of CHD. In HT, our analysis clarifies that previous inconsistent structural parameters determined by electron diffraction were artifacts that might have resulted from the use of inapplicable analytical equations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effective Hamiltonians derived from equation-of-motion coupled-cluster wave functions: Theory and application to the Hubbard and Heisenberg Hamiltonians

Effective Hamiltonians, which are commonly used for fitting experimental observables, provide a coarse-grained representation of exact many-electron states obtained in quantum chemistry calculations; however, the mapping between the two is not trivial. In this contribution, we apply Bloch’s formalism to equation-of-motion coupled-cluster (EOM-CC) wave functions to rigorously derive effective Hamiltonians in the Bloch’s and des Cloizeaux’ forms. We report the key equations and illustrate the theory by application to systems with two or three unpaired electrons, which give rise to electronic states of covalent and ionic characters. We show that the Hubbard and Heisenberg Hamiltonians can be extracted directly from the so-obtained effective Hamiltonians. By establishing a quantitative connection between many-body states and simple models, the approach facilitates the analysis of the correlated wave functions. We propose a simple diagnostic for assessing the validity of the model space choice based on the overlaps between the target- and model-space states. Finally, artifacts affecting the quality of electronic structure calculations such as spin contamination are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filling data analysis gaps in time-resolved crystallography by machine learning

There is a growing understanding of the structural dynamics of biological molecules fueled by x-ray crystallography experiments. Time-resolved serial femtosecond crystallography (TR-SFX) with x-ray Free Electron Lasers allows the measurement of ultrafast structural changes in proteins. Nevertheless, this technique comes with some limitations. One major challenge is the quality of data from TR-SFX measurements, which often faces issues like data sparsity, partial recording of Bragg reflections, timing errors, and pixel noise. To overcome these difficulties, conventionally, large volumes of data are collected and grouped into a few temporal bins. The data in each bin are then averaged and paired with the mean of their corresponding jittered timestamps. This procedure provides one structure per bin, resulting in a limited number of averaged structures for the entire time interval spanned by the experiment. Therefore, the information on ultrafast structural dynamics at high temporal resolution is lost. This has initiated research for advanced methods of analyzing experimental TR-SFX data beyond the standard binning and averaging method. To address this problem, we use a machine learning algorithm called Nonlinear Laplacian Spectral Analysis (NLSA), which has emerged as a promising technique for studying the dynamics of complex systems. In this work, we demonstrate the power of this algorithm using synthetic x-ray diffraction snapshots from a protein with significant data incompleteness, timing uncertainties, and noise. Our study confirms that NLSA is a suitable approach that effectively mitigates the effects of these artifacts in TR-SFX data and recovers accurate structural dynamics information hidden in such data.

Trujillo, Justin (ORCID:0000000285505360)↗

On the proper derivation of the Floquet-based quantum classical Liouville equation and surface hopping describing a molecule or material subject to an external field

We investigate different approaches to derive the proper Floquet-based quantum–classical Liouville equation (F-QCLE) for laser-driven electron-nuclear dynamics. The first approach projects the operator form of the standard QCLE onto the diabatic Floquet basis and then transforms to the adiabatic representation. The second approach directly projects the QCLE onto the Floquet adiabatic basis. Both approaches yield a form that is similar to the usual QCLE with two modifications: (1) The electronic degrees of freedom are expanded to infinite dimension and (2) the nuclear motion follows Floquet quasi-energy surfaces. However, the second approach includes an additional cross derivative force due to the dual dependence on time and nuclear motion of the Floquet adiabatic states. Our analysis and numerical tests indicate that this cross derivative force is a fictitious artifact, suggesting that one cannot safely exchange the order of Floquet state projection with adiabatic transformation. Our results are in accord with similar findings by Izmaylov et al., [J. Chem. Phys. 140, 084104 (2014)] who found that transforming to the adiabatic representation must always be the last operation applied, although now we have extended this result to a time-dependent Hamiltonian. Finally, this paper and the proper derivation of the F-QCLE should lay the basis for further improvements of Floquet surface hopping.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

False metals, real insulators, and degenerate gapped metals

This paper deals with a significant family of compounds predicted by simplistic electronic structure theory to be metals but are, in fact, insulators. This false metallic state has been traditionally attributed in the literature to reflect the absence of proper treatment of electron-electron correlation (“Mott insulators”) whereas, in fact, even mean-field like density functional theory describes the insulating phase correctly if the restrictions posed on the simplistic theory are avoided. Such unwarranted restrictions included different forms of disallowing symmetry breaking described in this article. As the science and technology of conductors have transitioned from studying simple elemental metals such as Al or Cu to compound conductors such as binary or ternary oxides and pnictides, a special class of degenerate but gapped metals has been noticed. Their presumed electronic configurations show the Fermi level inside the conduction band or valence band, yet there is an “internal band gap” between the principal band edges. The significance of this electronic configuration is that it might be unstable toward the formation of states inside the internal band gap when the formation of such states costs less energy than the energy gained by transferring carriers from the conduction band to these lower energy acceptor states, changing the original (false) metal to an insulator. The analogous process also exists for degenerate but gapped metals with the Fermi level inside the valence band, where the energy gain is defined by transfer of electrons from the donor level to the unoccupied part of the valence band. We focus here on the fact that numerous electronic structure methodologies have overlooked some physical factors that could stabilize the insulating alternative, predicting instead false metals that do not really exist (note that this is in general not a physical phase transition, but a correction of a previous error in theory that led to a false prediction of a metal). Such errors include: (i) ignoring spin symmetry breaking, such as disallowing magnetic spin ordering in CuBi2O4 or disallowing the formation of polymorphous spin networks in paramagnetic LaTiO 3 and YTiO 3 ; (ii) ignoring structural symmetry breaking, e.g., not enabling energy-lowering bond disproportionation (Li-doped TiO 2 , SrBiO 3 , and rare-earth nickelates), or not exploring pseudo-Jahn–Teller-like distortions in LaMnO 3 , or disallowing spontaneous formation of ordered vacancy compounds in Ba 4 As 3 and Ag 3 Al 22 O 34 ; and (iii) ignoring spin–orbit coupling forcing false metallic states in CaIrO 3 and Sr 2 IrO 4 . The distinction between false metals vs real insulators is important because (a) predicting theoretically that a given compound is metal even though it is found to be an insulator often creates the temptation to invoke high order novel physical effects (such as correlation in d-electron Mott insulators) to explain what was in effect caused by a more mundane artifact in a lower-level mean-field band theory, (b) recent prediction of exotic physical effects such as topological semimetals were unfortunately based on the above compounds that were misconstrued by theory to be metal, but are now recognized to be stable insulators not hosting exotic effects, and (c) practical technological applications based on stable degenerate but gapped metals such as transparent conductors or electrides for catalysis must rely on the systematically correct and reliable theoretical classification of metals vs insulators.

36 MATERIALS SCIENCE↗

Tilted fluctuation electron microscopy

Fluctuation electron microscopy (FEM) is a scanning nanodiffraction-based method that offers a unique approach to characterizing nanometer-scale medium-range order (MRO) in disordered materials. In addition to determining the degree of MRO, careful analysis of scanning nanodiffraction data can also be used to determine strain in thin film amorphous samples. We applied FEM to characterize the strain and MRO of magnetron sputtered amorphous tantalum (a-Ta) thin films over a range of tilt angles from 0° to 45° in order to measure any deviations between the in-plane and out-of-plane strain and MRO. We validate our approach using electron diffraction simulations of FEM experiments for a-Ta. We measure anisotropic strain in the simulated a-Ta diffraction patterns and find that the experimental a-Ta is isotropically strained within the accuracy of our method. Our approach provides a workflow for acquiring tilted scanning nanodiffraction data, determining the relative strain and ordering as a function of in- A nd out-of-plane directions, and removing any artifacts induced in FEM data due to strain. We also describe some limitations of the tilted FEM method when applied to thin films with very low strains.

36 MATERIALS SCIENCE↗

Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens

The performance of time-resolved photoemission experiments at fs-pulsed photon sources is ultimately limited by the e–e Coulomb interaction, downgrading energy and momentum resolution. Here, we present an approach to effectively suppress space-charge artifacts in momentum microscopes and photoemission microscopes. A retarding electrostatic field generated by a special objective lens repels slow electrons, retaining the k-image of the fast photoelectrons. The suppression of space-charge effects scales with the ratio of the photoelectron velocities of fast and slow electrons. Fields in the range from -20 to 01100 V/mm for E kin = 100 eV to 4 keV direct secondaries and pump-induced slow electrons back to the sample surface. Ray tracing simulations reveal that this happens within the first 40 to 3 μm above the sample surface for E kin = 100 eV to 4 keV. An optimized front-lens design allows switching between the conventional accelerating and the new retarding mode. Time-resolved experiments at E kin = 107 eV using fs extreme ultraviolet probe pulses from the free-electron laser FLASH reveal that the width of the Fermi edge increases by just 30 meV at an incident pump fluence of 22 mJ/cm2 (retarding field -21 V/mm). For an accelerating field of +2 kV/mm and a pump fluence of only 5 mJ/cm 2 , it increases by 0.5 eV (pump wavelength 1030 nm). At the given conditions, the suppression mode permits increasing the slow-electron yield by three to four orders of magnitude. The feasibility of the method at high energies is demonstrated without a pump beam at E kin = 3830 eV using hard x rays from the storage ring PETRA III. The approach opens up a previously inaccessible regime of pump fluences for photoemission experiments.

47 OTHER INSTRUMENTATION↗

Simultaneous mapping of nanoscale dielectric, electrochemical, and ferroelectric surface properties of van der Waals layered ferroelectric via advanced SPM

Ferroelectric surfaces involve a complex interplay between polarization and dielectric properties, internal and external surface charge screening, and ionic and electrochemical effects. There is currently no good way to simultaneously capture all the required information at appropriate length scales. To this end, we present an advanced scanning probe microscopy approach for simultaneously mapping surface potential, dielectric, and piezoelectric properties on the nanoscale. For quantitatively mapping electromechancial properties, we utilize interferometric displacement sensing piezoresponse force microscopy, which measures the effective piezoelectric coefficient free of background artifacts such as the cantilever body electrostatics. The dielectric and surface electrochemical properties are captured during G-mode electrostatic force microscopy/Kelvin probe force microscopy operated in the lift mode. We show the capabilities of this approach on the chemically phase separated composite sample consisting of a van der Waals layered ferroelectric CuInP 2 S 6 phase and a non-polar In 4/3 P 2 S 6 phase. Finally, we demonstrate domain structure evolution during thermally stimulated phase transition.

36 MATERIALS SCIENCE↗

EWALD: A macromolecular diffractometer for the second target station

Revealing the positions of all the atoms in large macromolecules is powerful but only possible with neutron macromolecular crystallography (NMC). Neutrons provide a sensitive and gentle probe for the direct detection of protonation states at near-physiological temperatures and clean of artifacts caused by x rays or electrons. Currently, NMC use is restricted by the requirement for large crystal volumes even at state-of-the-art instruments such as the macromolecular neutron diffractometer at the Spallation Neutron Source. EWALD’s design will break the crystal volume barrier and, thus, open the door for new types of experiments, the study of grand challenge systems, and the more routine use of NMC in biology. EWALD is a single crystal diffractometer capable of collecting data from macromolecular crystals on orders of magnitude smaller than what is currently feasible. The construction of EWALD at the Second Target Station will cause a revolution in NMC by enabling key discoveries in the biological, biomedical, and bioenergy sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fused x-ray and fast neutron CT reconstruction for imaging large and dense objects

Megavolt x-ray computed tomography (CT) is a powerful tool for three-dimensional characterization. However, its utility is limited for large objects composed of high-atomic number (Z) materials, where x rays fail to penetrate. Information from fast neutron CT (FNCT) can complement x-ray CT reconstructions since fast neutrons can more readily penetrate high-Z objects. In this work, we demonstrate a method for combining FNCT and x-ray CT data to create a single reconstruction, more accurate than could be achieved with either x rays or fast neutrons alone. The algorithm was tested on an exemplar comprising multiple concentric, nested cylinders of different materials. Simulated and empirical x-ray CT data were acquired for the exemplar using a 9 MV bremsstrahlung spectrum. Additional simulated and empirical FNCT data were acquired using an accelerator based fast neutron source. The FNCT data were used to synthesize x-ray CT data and augment the x-ray CT data missing due to lack of penetration. This approach mitigates artifacts that would otherwise negatively affect the accuracy and resolution of a single-modality reconstructed volume.

47 OTHER INSTRUMENTATION↗

Dual-energy fast neutron imaging using tunable short-pulse laser-driven sources

Here a novel dual-energy fast neutron imaging technique is presented using short-pulse laser-driven neutron sources to leverage their inherent adaptive spectral control to enable 3D volume segmentation and reconstruction. Laser-accelerated ion beams incident onto secondary targets create directional, broadband, MeV-class neutrons. Synthetic radiographs are produced of multi-material objects using ion and neutron spectra derived from analytic and numerical models. It is demonstrated that neutron images generated from small changes to the neutron spectra, controlled by altering the initial laser conditions, are sufficient to isolate materials with differing attenuation coefficients. This is first demonstrated using a simplistic combinatorial isolation method and then by employing more advanced reconstruction algorithms to reduce artifacts and generate a segmentation volume of the constituent materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging suprathermal x-rays from a laboratory plasma jet using PIN-diode-based and scintillator-based 1D pinhole/coded aperture cameras

A PIN-diode-based 1D x-ray camera and a scintillator-based 1D x-ray camera, both with a microsecond to submicrosecond time resolution, have been developed to perform time-resolved imaging of transient, low-intensity, suprathermal x-rays associated with magnetohydrodynamic instabilities disrupting a plasma jet. These cameras have a high detection efficiency over a broad x-ray band, a wide field of view, and the capability to produce >50 time-resolved frames with a ≤1 μs time resolution. The x-ray images are formed by a pinhole or by a coded aperture placed outside a vacuum chamber in which the plasma jet is launched. The 1D imaging shows that the location of the x-ray source is either a few centimeters away from an inner disk electrode or near a spatially translatable metal frame that is 30–40 cm away from the electrode. Compared to a pinhole, a coded aperture increases the signal collection efficiency but also introduces unwanted artifacts.

Instruments & Instrumentation↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

Flatfielding of hybrid pixel detectors in tender x-ray scattering

The ability of the soft matter interfaces beamline at National Synchrotron Light Source II to access x-ray energy in the tender x-ray regime, i.e., from 2.1 to 5 keV, enables new resonant x-ray scattering studies at the sulfur K-edge and others. We present a new approach to correct data acquired in the tender x-ray regime with a Pilatus3 detector in order to improve the data quality and to correct the various artifacts inherent to hybrid pixel detectors, such as variations in modules’ efficiency or noisy detector module junctions. Further, this new flatfielding significantly enhances the data quality and enables detection of weak scattering signals.

47 OTHER INSTRUMENTATION↗

Electrical, optical, and magnetic properties of amorphous yttrium iron oxide thin films and consequences for non-local resistance measurements

We present magnetic characterization, charge resistivity, and optical photoluminescence measurements on amorphous yttrium iron oxide thin films ( ⁠a-Y–Fe–O), with supporting comparisons to amorphous germanium (⁠ a-Ge) films. We measured magnetic properties with both SQUID magnetometry and polarized neutron reflectometry. These results not only confirm that a-Y–Fe–O is a disordered magnetic material with strong predominantly antiferromagnetic exchange interactions and a high degree of frustration, but also that it is best understood electrically as a disordered semiconductor. As with amorphous germanium, a-Y–Fe–O obeys expectations for variable-range hopping through localized electron states over a wide range of temperature. We also clarify the consequences of charge transport through such a semiconducting medium for non-local voltage measurements intended to probe spin transport in nominally insulating magnetic materials. We further compare non-local resistance measurements made with “quasi-dc” automated current reversal to ac measurements made with a lock-in amplifier. These show that the “quasi-dc” measurement has an effective ac current excitation with frequency up to approximately 22 Hz, and that this effective ac excitation can cause artifacts in these measurements including incorrect sign of the non-local resistance. Here, this comprehensive investigation of non-local resistance measurements in a-Y–Fe–O shows no evidence of spin transport on micrometer length scales, which is contrary to our original work, and in line with more recent investigations by other groups.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geometric phase in coupled cluster theory

It has been well-established that the topography around conical intersections between excited electronic states is incorrectly described by coupled cluster and many other single reference theories (the intersections are “defective”). Despite this, we show both analytically and numerically that the geometric phase effect (GPE) is correctly reproduced upon traversing a path around a defective excited-state conical intersection (CI) in coupled cluster theory. The theoretical analysis is carried out by using a non-Hermitian generalization of the linear vibronic coupling approach. Interestingly, the approach qualitatively explains the characteristic (incorrect) shape of the defective CIs and CI seams. Moreover, the validity of the approach and the presence of the GPE indicate that defective CIs are local (and not global) artifacts. This implies that a sufficiently accurate coupled cluster method could predict nuclear dynamics, including geometric phase effects, as long as the nuclear wavepacket never gets too close to the conical intersections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗