Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMPLIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than ± 1% with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 × 4 array of 6 mm × 6 mm × 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of ≈270 e - rms for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8% FWHM at 238 keV and 0.9% FWHM at 662 keV.

3D↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large mass single electron resolution detector for dark matter and neutrino elastic interaction searches

Large mass single electron resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CEvNS). In this paper we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of ~ 1e - /h + pair and a leakage current on the order of 10 -16 A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CEvNS like searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phonon-mediated high-voltage detector with background rejection for low-mass dark matter and reactor coherent neutrino scattering experiments

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. Furthermore, this new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light

For this work, we have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RF sheath modeling of experimentally observed plasma surface interactions with the JET ITER-Like Antenna

Waves in the Ion Cyclotron Range of Frequencies (ICRF) enhance local Plasma-Surface Interactions (PSI) near the wave launchers and magnetically-connected objects via Radio-Frequency (RF) sheath rectification. ITER will use 20MW of ICRF power over long pulses, questioning the long-term impact of RF-enhanced localized erosion on the lifetime of its Beryllium (Be) wall. Recent dedicated ICRF-heated L-mode discharges documented this process on JET for different types of ICRF antennas. Using visible spectroscopy in JET ICRF-heated L-mode discharges, poloidally-localized regions of enhanced (by ~2–4x) Be I and Be II light emission were observed on two outboard limiters magnetically connected to the bottom of the active ITER-Like Antenna (ILA). The observed RF-PSI induced by the ILA was qualitatively comparable to that induced by the JET standard, type-A2 antennas, for similar strap toroidal phasing and connection geometries. The Be II line emission was found more intense when powering the bottom half of the ILA rather than its top half. Conversely, more pronounced SOL density modifications were observed with only top array operation, on field lines connected to the top half of the ILA. So far the near-field modeling of the ILA with antenna code TOPICA (Torino Polytechnic Ion Cyclotron Antenna), using curved antenna model, was partially able to reproduce qualitatively the observed phenomena. A quantitative discrepancy persisted between the observed Be source amplification and the calculated, corresponding increases in E // field at the magnetically connected locations to the ILA when changing from only top to only bottom half antenna operation. This paper revisits these current drive phased and half-ILA powered cases using for the new simulations flat model of the ILA and more realistic antenna feeding to calculate the E// field maps with TOPICA code. Further, the Self-consistent Sheaths and Waves for Ion Cyclotron Heating Slow Wave (SSWICH-SW) code, which couples slow wave evanescence with DC Scrape-Off Layer (SOL) biasing, is used to estimate the poloidal distribution of rectified RF-sheath Direct Current (DC) potential V DC in the private SOL between the ILA poloidal limiters. The approach so far was limited to correlating the observed, enhanced emission regions at the remote limiters to the antenna near-electric fields, as calculated by TOPICA. The present approach includes also a model for the rectification of these near-fields in the private SOL of the ILA. With the improved approach, when comparing only top and only bottom half antenna feeding, we obtained good qualitative correlation between all experimental measurements and the calculated local variations in the E // field and V DC potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precompensation of gain nonuniformity in a Nd:glass amplifier using a programmable beam-shaping system

A programmable liquid crystal beam-shaping system was installed for a 200-mJ optical parametric chirped-pulse amplification (OPCPA) system front end and was applied to dramatically improve the beam uniformity in the subsequent amplifier. A highly nonuniform beam profile caused by gain inhomogeneity in the amplifier was pre-compensated by the beam shaping system using significantly improved open-loop and closed-loop algorithms. The details of the improved algorithms will be described. The issues of running a liquid crystal device with a high-energy, ultrashort-pulse laser, such as damage risk and temporal contrast degradation, will be addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of optically-pumped electron spin polarization in n-GaAs at high external electric fields

We use the technique of time-resolved Kerr rotation (TRKR) to measure the electron spin polarization generated by optical spin pumping in an n-type gallium arsenide (GaAs) epilayer when an external electric field is simultaneously applied on the sample. The drift of the electron spins under the influence of the external electric field is captured with spatial scans of the pump–probe separation. A significant decay in the magnitude of electron spin polarization with electric field is observed and is attributed to the increased inhomogeneous broadening caused by the field-induced drift and the hot electron effects. Here, we extend the electric field range to as high as the Gunn threshold field in the measurement and we do not observe a spin amplification effect due to the spin Gunn effect under our experimental scheme.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An activatable NIR fluorescent rosol for selectively imaging nitroreductase activity

Hypoxia (i.e., pO 2 ≤ ~1.5 %) is an important characteristic of tumor microenvironments that directly correlates with resistance against first-line therapies and tumor proliferation/infiltration. The ability to accurately identify hypoxic tumor cells/tissue could afford tailored therapeutic regimens for personalized treatment, the development of more-effective therapies, and discerning the mechanisms underlying disease progression. Fluorogenic constructs currently developed for identifying such tumor cells/tissue operate by targeting the bioreductive activity of primarily the nitroreductase (NTR) class of enzymes, but collectively such constructs unfortunately present photophysical and/or physicochemical shortcomings that could limit their effectiveness upon implementation. To overcome these limitations, we present the rational design, development, and evaluation of the first activatable ultracompact xanthene core-based molecular probe (NO 2 -Rosol) for selectively imaging NTR activity that affords an “OFF-ON” near-infrared (NIR) fluorescence response (ca. > 700 nm) alongside a remarkable Stokes shift (ca. > 150 nm) via NTR activity-facilitated modulation to its energetics whereby the resultant interplay discontinues an intramolecular d-PET fluorescence-quenching mechanism transpiring between directly-linked electronically-uncoupled π-systems comprising its components. DFT calculations guided selection of a suitable fluorogenic scaffold and nitroaromatic moiety candidate that when adjoined could (i) afford such photophysical response upon bioreduction by upregulated NTR activity in hypoxic tumor cells/tissue and (ii) employ a retention mechanism strategy that capitalizes on an inherent physical property of the NIR fluorogenic scaffold for achieving signal amplification. NO 2 -Rosol demonstrated 705 nm NIR fluorescence emission and a 157 nm Stokes shift, selectivity for NTR over relevant bioanalytes, and a 28- and 12-fold fluorescence enhancement in solution and between cells cultured under different oxic conditions, respectively. Finally, in establishing feasibility for NO 2 -Rosol to provide favorable contrast levels in in solutioand in vitrostudies, we anticipate NO 2 -Rosol similarly doing so in future studies towards its translation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Induction of hsp70, hsp60, hsp83 and hsp26 and oxidative stress markers in benzene, toluene and xylene exposed Drosophila melanogaster: Role of ROS generation

Exposure to benzene, toluene and xylene in the human population may pose a health risk. We tested a working hypothesis that these test chemicals cause cellular toxicity to a non-target organism, Drosophila melanogaster. Third instar larvae of D. melanogaster transgenic for hsp70, hsp83 and hsp26 and Oregon R{sup +} strain were exposed to 1.0-100.0 mM benzene, toluene and xylene for 2-48 h to examine the heat shock proteins (hsps), ROS generation, anti-oxidant stress markers and developmental end points. The test chemicals elicited a concentration- and time-dependent significant (p < 0.01) induction of the hsps in the exposed organism in the order of hsp70 > hsp83 {>=} hsp26 as evident by {beta}-galactosidase activity after 24 h. RT-PCR amplification studies in Oregon R{sup +} larvae revealed a similar induction pattern of these genes along with hsp60 in the order of hsp70 > hsp60 > hsp26 {>=} hsp83. Under similar experimental conditions, a significant induction of ROS generation and oxidative stress markers viz. superoxide dismutase, catalase, glutathione S-transferase, thioredoxin reductase, glutathione, malondialdehyde and protein carbonyl content was observed. Sub-organismal response was propagated towards organismal response i.e., a delay in the emergence of flies and their reproductive performance. While hsp70 was predominantly induced in the organism till 24 h of treatment with the test chemicals, a significant or insignificant regression of Hsp70 after 48 h was concurrent with a significant induction (p < 0.01) of hsp60 > hsp83 {>=} hsp26 in comparison to the former. A significant positive correlation was observed between ROS generation and these hsps in the exposed organism till 24 h and a negative correlation between ROS generation and hsp70 in them after 48 h indicating a modulatory role of ROS in the induction of hsps. The study suggests that among the tested hsps, hsp70 may be used as an early bioindicator of cellular toxicity against benzene, toluene and xylene and D. melanogaster as an alternative animal model for screening the risk posed by environmental chemicals.

60 APPLIED LIFE SCIENCES↗

Effect of allyl alcohol on hepatic transporter expression: Zonal patterns of expression and role of Kupffer cell function

During APAP toxicity, activation of Kupffer cells is critical for protection from hepatotoxicity and up-regulation of multidrug resistance-associated protein 4 (Mrp4) in centrilobular hepatocytes. The present study was performed to determine the expression profile of uptake and efflux transporters in mouse liver following treatment with allyl alcohol (AlOH), a periportal hepatotoxicant. This study also investigated the role of Kupffer cells in AlOH hepatotoxicity, and whether changes in transport protein expression by AlOH are dependent on the presence of Kupffer cells. C57BL/6J mice received 0.1 ml clodronate liposomes to deplete Kupffer cells or empty liposomes 48 h prior to dosing with 60 mg/kg AlOH, i.p. Hepatotoxicity was assessed by plasma ALT and histopathology. Hepatic transporter mRNA and protein expression were determined by branched DNA signal amplification assay and Western blotting, respectively. Depletion of Kupffer cells by liposomal clodronate treatment resulted in heightened susceptibility to AlOH toxicity. Exposure to AlOH increased mRNA levels of several Mrp genes, while decreasing organic anion transporting polypeptides (Oatps) mRNA expression. Protein analysis mirrored many of these mRNA changes. The presence of Kupffer cells was not required for the observed changes in uptake and efflux transporters induced by AlOH. Immunofluorescent analysis revealed enhanced Mrp4 staining exclusively in centrilobular hepatocytes of AlOH treated mice. These findings demonstrate that Kupffer cells are protective from AlOH toxicity and that induction of Mrp4 occurs in liver regions away from areas of AlOH damage independent of Kupffer cell function. These results suggest that Kupffer cell mediators do not play a role in mediating centrilobular Mrp4 induction in response to periportal damage by AlOH.

60 APPLIED LIFE SCIENCES↗

Use of a combined effect model approach for discriminating between ABCB1- and ABCC1-type efflux activities in native bivalve gill tissue

Aquatic organisms, such as bivalves, employ ATP binding cassette (ABC) transporters for efflux of potentially toxic chemicals. Anthropogenic water contaminants can, as chemosensitizers, disrupt efflux transporter function enabling other, putatively toxic compounds to enter the organism. Applying rapid amplification of cDNA ends (RACE) PCR we identified complete cDNAs encoding ABCB1- and ABCC1-type transporter homologs from zebra mussel providing the molecular basis for expression of both transporter types in zebra mussel gills. Further, efflux activities of both transporter types in gills were indicated with dye accumulation assays where efflux of the dye calcein-am was sensitive to both ABCB1- (reversin 205, verapamil) and ABCC1- (MK571) type specific inhibitors. The assumption that different inhibitors targeted different efflux pump types was confirmed when comparing measured effects of binary inhibitor compound mixtures in dye accumulation assays with predictions from mixture effect models. Effects by the MK571/reversin 205 mixture corresponded better with independent action, whereas reversin 205/verapamil joint effects were better predicted by the concentration addition model indicating different and equal targets, respectively. The binary mixture approach was further applied to identify the efflux pump type targeted by environmentally relevant chemosensitizing compounds. Pentachlorophenol and musk ketone, which were selected after a pre-screen of twelve compounds that previously had been identified as chemosensitizers, showed mixture effects that corresponded better with concentration addition when combined with reversine 205 but with independent action predictions when combined with MK571 indicating targeting of an ABCB1-type efflux pump by these compounds. - Highlights: • Sequences and function of ABC efflux transporters in bivalve gills were explored. • Full length Dreissena polymorpha abcb1 and abcc1 cDNA sequences were identified. • A mixture effect design with inhibitors was applied in transporter activity assays. • ABCB1- and ABCC-type efflux activities were distinguished in native gill tissue. • Inhibitory action of environmental chemicals targeted ABCB1-type efflux activity.

60 APPLIED LIFE SCIENCES↗

DNA viruses from different stages of a wastewater treatment plant in southwest Ohio

Wastewater treatment plants (WWTPs) house diverse populations of microbial communities that are dynamic across treatment stages. Although viruses, especially non-pathogenic ones are relatively less studied compared to their bacterial counterparts, they are equally important players in WWTP microbiomes. In this study, we sampled influent, activated sludge, and effluent stages of a WWTP in southwest Ohio to sequence their viral population using multiple displacement amplification (MDA) and metagenomic approaches. We recovered 1003 viral genomes, the majority of which were ssDNA (single-stranded DNA) viruses that formed distinct clusters representing novel species and phylogenetic groups not closely related to known human gut or terrestrial viruses. Additionally, tracking viruses across treatment stages showed several persisted across multiple treatment stages. These results suggest that further studies are needed to understand the persistence of viral populations, particularly non-pathogenic ones, across different stages of WWTPs.

59 BASIC BIOLOGICAL SCIENCES↗

Evidence of recombination and positive selection in cetacean papillomaviruses

Papillomaviruses (PVs) are small DNA viruses that have been associated with increased epithelial proliferation. Over one hundred PV types have been identified in humans; however, only three have been identified in bottlenose dolphins (Tursiops truncatus) to date. Using rolling circle amplification and degenerate PCR, we identified four novel PV genomes of bottlenose dolphins. TtPV4, TtPV5 and TtPV6 were identified in genital lesions while TtPV7 was identified in normal genital mucosa. Bayesian analysis of the full-length L1 genes found that TtPV4 and TtPV7 group within the Upsilonpapillomavirus genus while TtPV5 and TtPV6 group with Omikronpapillomavirus. However, analysis of the E1 gene did not distinguish these genera, implying that these genes may not share a common history, consistent with recombination. Recombination analyses identified several probable events. Signals of positive selection were found mostly in the E1 and E2 genes. Recombination and diversifying selection pressures constitute important driving forces of cetacean PV evolution.

60 APPLIED LIFE SCIENCES↗