Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

RECENT RESULTS FROM Nb3Sn SINGLE CELL CAVITIES COATED AT JLAB

Because of superior superconducting properties (Tc ~ 18.3K, Hs h ~ 425 mT and ? ~ 3.1 meV) compared to niobium, Nb3Sn promise better RF performance (Q0 and Eacc) and/or higher operating temperature (2 K Vs 4.2 K) for SRF cavities. Nb3Sn-coated SRF cavities are produced routinely by depositing a few micron-thick Nb3Sn films inside of Nb cavities via tin vapor diffu-sion technique. Early results from Nb3Sn cavities coat-ed with this technique exhibited precipitous low field Q-slope, also known as Wuppertal slope. Several Nb3Sn single cell cavities coated at JLab appeared to exhibit similar Q-slope. RF testing of cavities and ma-terials study of witness samples were continuously used to modify the coating protocol. At best condition, we were able to produce Nb3Sn cavity with Q0 in ex-cess of ? 5×1010 at 2 K and ? 2×1010 at 4 K up the ac-celerating gradient of ~15 MV/m, without any signifi-cant Q-slope. In this presentation, we will discuss re-cent results from several Nb3Sn coated single-cell cavities linked with material studies of witness sam-ples, coating process modifications and the possible causative factors to Wuppertal slope.

Pudasaini, U.↗

LGFCS Prototype System Testing (Final Report)

In the project, LGFCS assembled and tested its modular SOFC Power System that incorporates all critical technology improvements identified for its “product-like” demonstration. This product demonstrator is expected to meet customer and LGFCS performance expectations for operation, availability, durability and serviceability. The principal technology improvements are aimed at increasing the fuel cell power output and reducing the stack degradation rate. Improvements were also made for added system robustness and increased reliability. The objective of this program is to test a 250kWe thermally self-sustaining modular solid oxide fuel cell (SOFC) Power System for a minimum of 5,000 hours while advancing this commercial prototype product demonstrator to a Technical Readiness Level (TRL) 7. The SOFC system was tested on a site provided by Stark State College in North Canton, Ohio. System performance and degradation as well as cost estimates were compared to established SOFC Program performance metrics to assess progress. The major achievements were to assemble, and QA qualify 70 fuel cell strips for 12 integrated blocks into a fuel cell vessel and install it into a generator module with the fuel and power electronics modules on the test site. Performance to date included over 1800 hours on load at 250 KWAC to the grid with a DC efficiency of 61% and AC efficiency of 55%. Power degradation was less than 0.4% per 1000 hours and NOx emissions met standards. The LGFCS SOFC Prototype System (GEN0) was demonstrated in an operational environment and therefore achieving Technical Readiness Level 7. The work presented here represents the efforts of all the employees of LG Fuel Cell Systems. Their dedication and hard work made GEN0 possible and successful.

03 NATURAL GAS↗

Advanced Combustion Numerics and Modeling: FY19 Third Quarter Report

This project is focused on early stage research and development of numerical methods and models to improve advanced engine combustion concepts and systems. The current focus is on the development of new mathematics and algorithms to reduce the time to solution for advanced combustion engine design using detailed fuel chemistry. The research is prioritized towards the most time-consuming workflow bottlenecks (computer and human) and accuracy gaps that slow ACS program members. Zero-RK, the fast and accurate chemical kinetics solver software developed in this project, is central to the research efforts and continues to be developed to address the current and emerging needs of engine designers, engine modelers and fuel mechanism developers.

02 PETROLEUM↗

PS Ripple Study during the 2019 Fermilab Booster Experiment

S.02 has been one of the experiment of the 2019 Fermilab Booster Studies. Its goal had been to evaluate the tune ripple on beam stability. A prerequisite is to measure the voltage ripple in both AC and DC mode. With a good knowledge of the Booster transmission line model one can determine how voltage ripple leads to tune modulation depth at the same ripple frequency.

43 PARTICLE ACCELERATORS↗

Studying Qubit Interactions with Multimode Cavities Using QuTiP

The project uses QuTiP, a quantum computing framework [1], to simulate interactions between two-qubits coupled with each other via three resonators. The main aim of this project is to build a machinery of techniques to understand complex qubit-cavity interactions using QuTiP’s functionalities. The system simulated mimics the one constructed by McKay et. al. [2] (M15) and the results of the simulations closely agree with M15’s experimental results. The effect of the coupling strength between the qubits and the cavities is studied. It was observed that stronger couplings generated larger separations between the eigen-modes. Studies involving resonance were used to construct the iSWAP gate, a universal quantum logic gate. This study showed the importance of external thermal losses due to cavity dissipation, and qubit decay and dephasing. The Landau-Zener model was tested for the case of multiple crossing; the model motivated the comparison of three scenarios where the 2 qubits were coupled via: 1 cavity, 3 cavities, and 6 cavities. The study concluded that having multiple modes, which is a consequence of having multiple cavities, is advantageous for transferring energy from the qubit to the cavity. Finally, the ac-Stark shift was measured in the system and it’s dynamics showed excellent agreement with the experimental results obtained by M15.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pueblo of Picuris Phase I Community Solar Project (Final Report)

The Pueblo of Picuris Community Solar Project (Project) is a 1-megawatt (MW) alternating current (AC) ground mounted, fixed tilt solar photovoltaic system that became operational on December 18th, 2017. The Project, which was partially funded by the DOE (Grant No. DEIE0000033), generates revenue for the Tribe through a Power Purchase Agreement (PPA) with the electric utility, Kit Carson Electric Cooperative. The PPA revenue provides Tribal members with residential and commercial electric utility bill offsets and also supports critical Tribal programs. This Final Report provides a technical overview of the Project, documents the Project’s development process and outcomes, identifies successes and challenges, and offers recommendations for similarly funded tribal projects.

1 megawatt solar↗

Oak Ridge National Laboratory Current Magnitude and Frequency Response of SIPROTEC Relays

This project examined the current magnitude and frequency response of 7SJ61 and 7SJ62 SIPROTEC relays. The measured sample frequencies for the 7SJ61 and 7SJS62 relays were 800 and 960 Hz, respectively. The relays were tested at frequencies of up to 1 and 20.16 kHz. Two experiments were run in a lab environment. The first experiment was run at frequencies of up to 1 kHz every 10 Hz. The second one was run at frequencies of up to 20.16 kHz every 200 and 240 Hz (common factors of sample rate frequency) for the 7SJ61 and 7SJ62 SIPROTEC relays, respectively. Both experiments were set at a current magnitude of 0.1 and 0.5 Arms. A testbed with a Relay Test Equipment (RTE) was set to run the experiment at frequencies of up to 1 kHz, while a testbed with a RTE and High Frequency Power Source/ Amplifier (HFPS/A) was set to run at frequencies of up to 20.16 kHz. Currents of 0.1 and 0.5 Arms at different frequencies were connected at Phase A of the relays, and a current of 1 Arms (60 Hz) was connected at Phase B of relays. The 1 Arms current allowed the relays to trip and saved their record events by setting both relays at a definite-time overcurrent protection function. The record events were collected after the 7SJ61 and 7SJ62 relays tripped, and the current magnitude and frequency were plotted. The record events from the relays were collected using the DIGSI® 4 software. The SYNCHROWAVE® Event and MATLAB® software were then used to plot the current magnitude and frequency, respectively, from the relay record events. The current magnitude and frequency were plotted at time and frequency domain, respectively.The 7SJ61 and 7SJ62 relays measured source frequencies of up to 400 and 480 Hz, respectively. The percentage error of frequency for the relays increased after 400 and 480 Hz, respectively. The 7SJ62 relay with 0.1 and 0.5 Arms measured the alias frequency up to 1440 Hz. The 7SJ61 relay with 0.1 and 0.5 Arms measured the alias frequency up to 1000 and 1200 Hz, respectively. At frequencies higher than the alias frequency, the relays measured a DC amplitude current instead of an AC amplitude current. In the DC amplitude current zone, non-desired frequencies were measured by both relays. The current magnitude intensity (dB) for the 7SJ61 and 7SJ62 relays from 1 to 20.16 kHz were plotted. The current magnitude intensity for the 7SJ61 relay decreased up to 2600 and 1200 Hz for 0.5 and 0.1 Arms tests, respectively. However, the current magnitude intensity for the 7SJ62 relay decreased up to 4800 and 2640 Hz for 0.5 and 0.1 Arms tests, respectively. The current magnitude and frequency response study for the 7SJ61 and 7SJ62 relays was performed satisfactorily, observing the source, alias, and non-desired measured frequency zones for both relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Analytics for Electrical Distribution Systems with Micro PMUs (GMLC 1.4.9 Technical Report)

This report describes how electrical utilities with residential, industrial, commercial and government customers make decisions using Data Analytics (DA) applications and discusses how OpenFMB was leveraged to share that data among disparate types of devices for DA. OpenFMB is a data standard developed by utilities for distributed communication and control of power system assets. Here we explored how OpenFMB can be used for sharing analytics and what those analytics could be for a set of representative grid devices. A review of DA applications performed by electrical utilities and customers is presented. An overview of how the testbed we used was built and configured is summarized. Several experiments which were carried out to explore the capabilities of OpenFMB alongside other data sharing mechanisms for gathering sensor measurements and sharing analytics is also discussed. And finally a comparison of OpenFMB and LBNL’s SPARK framework is summarized. Today’s electrical utilities focus on monitoring the real-time customer consumptions, offering new real-time tariff models based on customer usage habits (rewards and punishments), providing energy peak during peak load times (plan energy generation and distribution), improving the load management for transformers and power lines, and controlling the energy and grid resources efficiently. On the other hand, the DA applications for residential customers are based on modifying the customer electricity usage habit to save money, making accurate and timely decisions for electrical billing. However, the DA applications for industrial, commercial and government customers focus on creating efficient programs to improve the environmental condition (reducing CO₂ emission), developing better load forecasting for industrial and/or commercial activities. In this project, a testbed was built to explore how the OpenFMB framework can be used to distribute data among various types of representative grid edge devices. Micro PMUs (Phasor Measurement Unit) were used to collect and transmit data to an OpenPDC server alongside relays with a framework configured with a system using OpenFMB to collect and transmit data. The testbed was composed of a physical asset based on a 60 Hz AC radial power system constructed using SI-GRID components. The power system consisted of a 3-phase 14 volts line-to-ground (24 volts line-to-line) power source, three 3-phase line emulators, a programmable resistive load bank, two smart relays, two micro PMUs, and a (SCADA) and Phasor Data Concentrator (PDC) computer. This testbed configuration allowed us to perform breaker operation tests collecting data from the micro PMUs and from the relays’ sensors. During the micro PMU breaker operation tests we collected the measured and estimated fundamental voltages, currents, frequency as well as the total true, reactive and apparent power. The displacement power factor from two micro PMUs located in parallel power lines was also used. The software steps for the implementation of the Synchrophasor system are explained in detail in this report. The setting (1-2-3) and data collection (4-5) phases were performed with a free download open source software. In the setting phase, the micro PMUs were set (1), the data stream for each micro PMU was validated, and the connection and configuration files were created (2). The PDC computer was set using the connection and configuration files of the micro PMUs (3). In the data collection phase, the binary data from the micro PMUs was collected (4), and the binary data files of the micro PMUs was converted to analyze the test results (5). OpenFMB was configured to use protocol translators to read Modbus and transform the reading into the OpenFMB data model to be read for DA applications.Our experiments showed that by leveraging the OpenFMB data model and the micro PMUs together we could obtain better situational awareness of network faults, which in some cases could lead to failures in the system and would be less perceivable otherwise. For example, in one experiment the fundamental RMS current angle, and the fundamental displacement power factor (estimated by the ratio between the measured real and apparent total power) had a disturbance at the micro PMU connected to the beginning of the parallel power line because the breaker was opened without the operators or SCADA system’s knowledge, and no current was available. Based on the breaker state scenarios and micro PMU locations, the DA applications using the current angle and displacement power factor from the micro PMUs should be studied in detail to avoid a non-desired measurement that could affect the decision from the DA. Also, the sample rates for PMU, Relay and micro PMU devices were compared. The DA application improved the control and operation between the electrical utilities and their customers (residential, industrial, transportation, commercial and government). The higher the sample rate, the better the quality of the measurement for DA estimations.

42 ENGINEERING↗

American Chemical Society's summer school in nuclear and radiochemistry. Final report

The ACS Summer Schools in Nuclear and Radiochemistry (herein called “Summer Schools”) were held each year at San Jose State University (SJSU) and Brookhaven National Laboratory (BNL). The Summer Schools are an intensive, six-week program that includes both a lecture component covering fundamental principles of nuclear chemistry and radiochemistry and a laboratory component providing hands-on experience for the students to observe and test many of the basic principles that they learn about in lecture and in the special seminars. Each site hosts 12 undergraduate students annually. Participants are selected from a nation-wide pool of applicants who are currently enrolled as undergraduates seeking bachelors’ degrees, preferably in disciplines of physical sciences or engineering. To broaden the students’ perspectives on nuclear science, prominent research scientists active in nuclear and/or radiochemical research participate in a Guest Lecture Series. Symposia emphasizing nuclear security, nuclear medicine, and career opportunities are conducted as a part of the program.

07 ISOTOPE AND RADIATION SOURCES↗

TWF Waste Container Intra-Facility Transfer and Outgoing Shipment

This procedure provides instructions for the inspection and transfer of Transuranic (TRU) Waste containers within the Transuranic Waste Facility (TWF) (Waste Storage Buildings [WSBs], Characterization Waste Storage Building [CWSB]) and Characterization Trailers. This also includes the preparation to transfer to other LANL facilities. Performance of this procedure meets the requirements of SR 4.2.1.1, 4.2.1.2, 4.2.1.4, 4.2.1.5, 4.3.4.1, SAC 5.9.1, SAC 5.9.3 and AC 5.8.13 2nd bullet, as well as requirements set forth in the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit (HWFP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Accelerator Technology (Final Report)

Superconducting radio-frequency (SRF) acceleration, together with high precision RF field control and high precision beam instrumentation and control, is a key technology for future next generation accelerators. In the past 10 years, significant progress on these technologies has been made jointly at KEK and US laboratories. The research progress summarized here is Cornell University’s contribution to a continued US-Japan collaborative accelerator research effort. The combined objectives of this collaboration were to solve critical technical issues related to SRF acceleration technology, related to low emittance beam generation, and related to reducing the vertical beam size of the ATF2 final focus beam line. These joint efforts significantly advance current accelerator technologies. The specific objective of the Cornell University part of this collaboration was to develop, in close connection with KEK and FNAL, new SRF cavity Nb3Sn thin-film coating technologies for transformational cavity performance. Cornell is a world leader in the synthesis of Nb3Sn for SRF application, and has produced the first-ever next-generation non-niobium (i.e., Nb 3 Sn) prototype SRF accelerator cavities with cryogenic efficiency exceeding that of traditional niobium cavities. These next-generation Nb 3 Sn SRF cavities strongly reduce AC power consumption of SRF based accelerators, and also enable using greatly simplified cryogenic cooling infrastructure, thereby making SRF technology available to a much wider range of accelerator applications. During this project, Cornell has designed and started fabrication of a new Nb 3 Sn coating setup, which will be large enough to coat full-scale (i.e., multi-cell) SRF accelerator cavities. In addition, Cornell University has participated in other collaborative activities at KEK and partner US laboratories.

43 PARTICLE ACCELERATORS↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report-WestSmart EV: Western Smart Plug-in Electric Vehicle Community Partnership

The WestSmartEV (WSEV) project has accelerated adoption of plug-in electric vehicles (PEV) throughout the PacifiCorp/Rocky Mountain Power’s (RMP) service territory in the intermountain west by developing a large-scale, sustainable PEV charging infrastructure network with coordinated PEV adoption programs. The project objectives have strategically deployed 79 DC fast charging to create two primary electric interstate highway corridors along I-15 and I-80; incentivized installation of Level 2 AC chargers at workplace locations; incentivized the purchase of PEVs; provided all electric solutions for first-mile and last-mile trips, including electrified mobility service; provided centralized data collection, analysis, modeling, and tool development to inform investment and policy decisions; and developed education outreach materials and conducted workshops across the WSEV region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximizing Revenue from Electrical Energy Storage Paired with Community Solar Projects in NYISO Markets

The New York State Public Service Commission recently made significant changes to the compensation mechanisms for distributed energy resources, such as solar generation. The new mechanisms, called the Value of Distributed Energy Resources (VDER), alter the value proposition of potential installations. In particular, multiple time-of-generation based pricing alternatives were established, which could lead to potential benefits from pairing energy storage systems with solar installations. This paper presents the calculations to maximize revenue from a solar photovoltaic and energy storage system installation operating under the VDER pricing structures. Two systems in two different zones within the New York Independent System Operator area were modeled. The impact of AC versus DC energy storage system interconnections with solar generation resources was also explored. The results show that energy storage systems could generate significant revenue depending on the pricing alternative being targeted and the zone selected for the project.

14 SOLAR ENERGY↗

Mixed Integer Nonlinear Programming Approaches to Enhance Resiliency and Response Strategies in Critical Infrastructure

Motivation. Critical infrastructures are large, complex engineered systems that must be operated robustly under abnormal conditions resulting from natural hazards or intentional acts. For example, electric power systems must be robust to line faults, water utilities must rapidly mitigate contamination incidents, and computing networks must adapt to adversarial intrusions to protect critical information. Problem. It is difficult for decision-makers within resiliency analysis in critical infrastructure to optimize designs and develop effective response strategies that can account for uncertainties. Facing incomplete information and the sheer scope that a natural hazard or attack vector may incorporate, response can be ineffective without reliable, scalable decision support tools. These problems are intrinsically nonlinear and involve discrete decisions, and unfortunately, existing off-the-shelf mathematical programming methods cannot support optimization-based decision-making of these nonlinear at scale. Method/Approach and Results. This project emphasized development of fundamental optimization strategies that supported real- time mitigation and response for critical infrastructures. In particular, the project developed multi- tree approaches based on piecewise outer-approximations for solution of mixed-integer nonlinear programming (MINLP) problems. These techniques alternate between an MILP or MISOCP relaxation to obtain a lower bound and candidate discrete solutions and an NLP subproblem to obtain upper bounds. Using tailored relaxations based on problem structure, these methods were used to solve several key applications in resilience and response of critical infrastructure. This work resulted in two open-source, copyrighted software packages: CORAMIN (https://github.com/Coramin/Coramin) -- an object-oriented mathematical programming framework that supports tailored multi-tree algorithms for solution of large- scale mixed-integer nonlinear programming; and EGRET (Electrical Grid Research and Engineering Toolkit) (https://github.com/grid- parity-exchange/Egret) -- a declarative mathematical programming framework built upon CORAMIN and Pyomo for formulation and solution of resilience and operations problems in power grid systems. Furthermore, these tools resulted in several important published results, including the following: The first known global optimization approach that could solve the unit-commitment problem with nonlinear power flow constraints on medium-sized test problems; Improved parallel optimization-based bounds tightening and strengthening of relaxations of AC power flow constraints; and, Optimization-based approaches for improved grid resilience and use of demand response to improve grid resilience with reduction in capital requirements. Result Implications. This project developed first-of-a-kind algorithms for decision-making in critical infrastructure resilience operations and planning, as well as a next-generation toolkit for MINLP researchers. These approaches leveraged high-performance computing architectures to solve some of the largest, most challenging nonlinear discrete optimization problems to global optimality, and these successes were captured in open-source software to enable optimization-based decision-making, and efficient solution of MINLP formulations for electric power transmission grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NgramPPM: Compression Analytics without Compression

Arithmetic Coding (AC) using Prediction by Partial Matching (PPM) is a compression algorithm that can be used as a machine learning algorithm. This paper describes a new algorithm, NGram PPM. NGram PPM has all the predictive power of AC/PPM, but at a fraction of the computational cost. Unlike compression-based analytics, it is also amenable to a vector space interpretation, which creates the ability for integration with other traditional machine learning algorithms. AC/PPM is reviewed, including its application to machine learning. Then NGram PPM is described and test results are presented, comparing them to AC/PPM.

97 MATHEMATICS AND COMPUTING↗

Utility-Scale Solar, 2021 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2021 Edition” provides an overview of key trends in the U.S. market, with a focus on 2020. Highlights of this year’s update include: A record of nearly 9.6 GWAC of new utility-scale PV capacity came online in 2020, bringing cumulative installed capacity to more than 38.7 GWAC across 43 states. 89% of all new utility-scale PV capacity added in 2020 uses single-axis tracking. Median installed project costs declined to $\$$1.4/WAC (or $\$$1.1/WDC) in 2020. Project-level capacity factors vary widely, from 9% to 36% (on an AC basis), with a sample median of 24%. The report explores drivers of this variation. Utility-scale PV’s LCOE fell to $\$$34/MWh in 2020 ($\$$28/MWh if factoring in the federal investment tax credit, or ITC). PPA prices have largely followed the decline in solar’s LCOE over time, but have stagnated more recently. Prices from a sample of recent contracts average just above $\$$20/MWh (levelized). In 2020, solar’s average market value (defined in the report to include only energy and capacity value) exceeded average wholesale prices in 12 of the 17 balancing authorities analyzed (including 4 of the 7 independent system operators across the United States). Adding battery storage is one way to increase the value of solar. Our public data file tracks metadata for more than 150 PV+battery hybrid projects that are already online or that have secured offtake arrangements. At the end of 2020, there were at least 460 GW of utility-scale solar power capacity within the interconnection queues across the nation, 160 GW of which include batteries. For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗