Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Effects of Cone Penetrometer Testing on Shallow Hydrogeology at a Contaminated Site

Penetration testing is a popular and instantaneous technique for subsurface mapping, contaminant tracking, and the determination of soil characteristics. While the small footprint and reproducibility of cone penetrometer testing makes it an ideal method for in-situ subsurface investigations at contaminated sites, the effects to local shallow groundwater wells and measurable influence on monitoring networks common at contaminated sites is unknown. Physical and geochemical parameters associated with cone penetrometer testing were measured from a transect of shallow groundwater monitoring wells adjacent to penetrometer testing. For wells screened above the depth of cone refusal, the physical advancement and retraction of the cone had a significant effect ( p < 0.01) on water level for several pushes within 10 meters of a monitoring well, and a measured increase in specific conductivity. No effect on geochemistry or water level was observed in continuous monitoring data from wells screened below the depth of cone refusal, but variability in specific conductivity from these wells during penetration testing was only a fraction of the natural variation measured during precipitation events. Continuous measurements of specific conductivity and water level demonstrated that the effects of penetration testing have limited spatial and temporal distributions with a null effect post-testing.

54 ENVIRONMENTAL SCIENCES↗

Reducing Sample Loss in Measurement of Heat of Vaporization of Ethanol/Gasoline Blends by Differential Scanning Calorimetry/Thermogravimetric Analysis

Higher gasoline Heat of Vaporization (HOV) can enable higher compression-ratio direct injection spark ignition engines by providing evaporative cooling that effectively increases fuel knock resistance. Methods to directly measure this fuel property in complex gasoline samples are not well developed. The objective of the present study was to further improve a Differential Scanning Calorimetry/Thermogravimetric Analyzer (DSC/TGA) method to measure the total and partial HOV of gasoline. Ten market gasoline samples were chosen to have a wide range of properties to assess the method's capability across the entire volatility range with an emphasis on understanding how well the method captures the initial 10 percent (%) of sample evaporation and how much sample is left unevaporated at the end of the experiment. Modifications to the sample preparation/introduction method as well as to the instrument itself were made to reduce initial sample losses which included measurements of the HOV at 10 degrees C and 5 degrees C (in a cold chamber) as well as under (uncontrolled) ambient conditions. Experimental results from the DSC/TGA were compared to calculated total HOV results based on Detailed Hydrocarbon Analysis (DHA). Results from the two methods agreed very well with the difference being 5% or less in almost every case. In addition, the repeatability of the method was investigated by analyzing samples in triplicate at the three temperatures investigated. One valuable conclusion from the study was that the lower temperatures of 10 degrees C and 5 degrees C enabled more reproducible measurements for both total and partial HOV. This improved precision may be caused by the fact that temperature control in the cold chamber was more reliable than the ambient laboratory temperature control. Additionally, cold chamber experiments, due to ergonomic limitations, did not allow for the use of a lid on the sample pan. The reproducibility of the evaporation rate was found to be highly dependent on the pan/lid fit which can vary significantly such that elimination of the lid improved measurement precision while operation at sub-ambient temperature slowed the evaporation rate. Results detailing sample preparation and instrument modifications as well as a detailed comparison of total and partial HOV results are presented.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Acoustic particle separation

A method is described which uses acoustic energy to separate particles of different sizes, densities, or the like. The method includes applying acoustic energy resonant to a chamber containing a liquid of gaseous medium to set up a standing wave pattern that includes a force potential well wherein particles within the well are urged towards the center, or position of minimum force potential. A group of particles to be separated is placed in the chamber, while a non-acoustic force such as gravity is applied, so that the particles separate with the larger or denser particles moving away from the center of the well to a position near its edge and progressively smaller lighter particles moving progressively closer to the center of the well. Particles are removed from different positions within the well, so that particles are separated according to the positions they occupy in the well.

Barmatz, M. B.↗

Numerical simulations of a siphon mechanism for quiescent prominence formation

Quiescent prominences represent a significant challenge to our understanding of the flow of mass and energy in the outer layers of the solar atmosphere. A small number of quiescent prominences contain as much mass as the entire corona (Athay, 1976). The problem then is how to get that much material into the relatively small volume of a prominence and maintain it at a temperature of 10,000 K in close proximity to material at one million K. The thermal insulation to conduction provided by the magnetic field explains the disparate temperatures. The mass source problem is less well understood. One method for supplying mass to the prominence is to siphon it from the chromosphere. The siphon mechanism begins with a magnetic loop that evolves into a configuration with a gravitational well, such as that described by Kippenhahn and Schluter (1957). This could be formed, for example, by a twist in the magnetic field. A gravitational well could also be formed by a condensation induced sag in the field. This could further enhance the condensation process. Once this well has formed, or as it is forming, the material in the well area of the loop must cool and condense to the point where radiative losses exceed any heat input. Additional material must also flow into the well from the underlying chromosphere to supply the mass required to form the prominence. One example from a series of numerical simulations that were performed to study the formation of quiescent prominences is presented.

Poland, A. I.↗

Hydrodynamically induced fluid transfer and non-convective double-diffusion in microgravity sliding solvent diffusion cells

Microgravity can provide a diffusion-dominated environment for double-diffusion and diffusion-reaction experiments otherwise disrupted by buoyant convection or sedimentation. In sliding solvent diffusion cells, a diffusion interface between two liquid columns is achieved by aligning two offset sliding wells. Fluid in contact with the sliding lid of the cavities is subjected to an applied shear stress. The momentum change by the start/stop action of the well creates an additional hydrodynamical force. In microgravity, these viscous and inertial forces are sufficiently large to deform the diffusion interface and induce hydrodynamic transfer between the wells. A series of KC-135 parabolic flight experiments were conducted to characterize these effects and establish baseline data for microgravity diffusion experiments. Flow visualizations show the diffusion interface to be deformed in a sinusoidal fashion following well alignment. After the wells were separated again in a second sliding movement, the total induced liquid transfer was determined and normalized by the well aspect ratio. The normalized transfer decreased linearly with Reynolds number from 3.3 to 4.0% (w/v) for Re = 0.4 (Stokes flow) to a minimum of 1.0% for Re = 23 to 30. Reynolds numbers that provide minimum induced transfers are characterized by an interface that is highly deformed and unsuitable for diffusion measurements. Flat diffusion interfaces acceptable for diffusion measurements are obtained with Reynolds numbers on the order of 7 to 10. Microgravity experiments aboard a sounding rocket flight verified counterdiffusion of different solutes to be diffusion dominated. Ground control experiments showed enhanced mixing by double-diffusive convection. Careful selection of experimental parameters improves initial conditions and minimizes induced transfer rates.

Pollmann, Konrad W.↗

Long-Wavelength-Infrared Hot-Electron Transistor

Dark current reduced by energy-discriminating quantum filter. Very long-wavelength-infrared hot-electron transistor developed. Device detects photons at wavelengths around 16 micrometers. Comprises photodector integrated with energy-discriminating quantum filter in multiple-quantum-well structure. Made of variously doped and undoped layers of GaAs (quantum wells) and Al(x)Ga(1-x)As (barriers between wells). In transistor, bound-to-continuum GaAs/Al(x)Ga(1-x)As multiple-quantum-well infrared photodectors (QWIP) serves as photosensitive emitter. Wide quantum well serves as base, and there is thick barrier between base and collector. Combination of barrier and base quantum well acts as energy-discriminating filter: electrons with higher energies pass through filter to collector, those with lower energies blocked and diverted from output-current path through base contact.

Gunapala, Sarath D.↗

Performance Analysis of Two Early NACA High Speed Propellers with Application to Civil Tiltrotor Configurations

The helicopter industry is vigorously pursuing development of civil tiltrotors. One key to efficient high speed performance of this rotorcraft is prop-rotor performance. Of equal, if not greater, importance is assurance that the flight envelope is free of aeroelastic instabilities well beyond currently envisioned cuise speeds. This later condition requires study at helical tip Match numbers well in excess of 1.0. Two 1940's 'supersonic' propeller experiments conducted by NACA have provided an immensely valuable data bank with which to study prop-rotor behavior at transonic and supersonic helical tip Mach numbers. Very accurate 'blades alone' data were obtained by using nearly an infinite hub. Tabulated data were recreated from the many thrust and power figures and are included in two Appendices to this report. This data set is exceptionally well suited to re-evaluating classical blade element theories as well as evolving computational fluid dynamic (CFD) analyses. A limited comparison of one propeller's experimental results to a modem rotorcraft CFD code is made. This code, referred to as TURNS, gives very encouraging results. Detailed analysis of the performance data from both propellers is provided in Appendix A. This appendix quantifies the minimum power required to produce usable prop-rotor thrust. The dependence of minimum profile power on Reynolds number is quantified. First order compressibility power losses are quantified as well and a first approximation to design air-foil thickness ratio to avoid compressibility losses is provided. Appendix A's results are applied to study high speed civil tiltrotor cruise performance. Predicted tiltrotor performance is compared to two turboprop commercial transports. The comparison shows that there is no fundamental aerodynamic reason why the rotorcraft industry could not develop civil tiltrotor aircraft which have competitive cruise performance with today's regional, turboprop airlines. Recommendations for future study that will insure efficient prop-rotor performance to well beyond 400 knots are given.

Harris, Franklin D.↗

Stacking Multiple Ion Captures in The High Performance Antiproton Trap (HiPAT)

The High performance Antiproton Trap (HiPAT) research project was initiated by the Marshall Space Flight Center's propulsion Research Center to examining the fundamental behavior of low energy antiprotons. Stored antiproton would ultimately be used for experimental demonstration of basic propulsive concepts. Matter-antimatter annihilation produces approximately 10(exp 8) MJ/g nearly 10 orders of magnitude more energy per unit mass than chemical based combustion, hence NASA's interest. To achieve containment, HiPAT utilizes a type of electromagnetic bottle know as a Penning trap positioned within an ultrahigh vacuum test section. Recently, the HiPAT hardware configuration has been enhanced to facilitate the capture of multiple normal matter ion burst. This endeavor is often referred to as "stacking" and used to increasing the number of captured particles. A prior normal matter experimental effort, successfully demonstrated the effectiveness of single burst capture. The stacking process is accomplished by manipulating the electric field generated by the confinement electrodes i.e. adjusting the well potential depth. These potential well values are initially configured to maximize the quantity of captured ions per burst; shallow wells with a depth of 100 volt or less (referenced to the incoming ion beam energy) are typically selected. Once captured, a cooling interval is required to reduce the energy of trapped particles below the lower extent of the "trap door" (or leading electrode) ion emitting potential. This is necessary such that a new burst of hot ions can be introduced while preventing those already inside from escaping. The cooling time is driven by a combination of mechanisms such as synchrotron radiation, background gas scattering, and resistive damping in a time scale on the order of minutes. A potential for reducing this hold period is to actively manipulate the electric field shape, using the power supply control system, to produce a deeper potential well. The trapped ions ride down the morphing well to a lower potential energy, leaving margin to once again cycle the "trap door" capturing a new burst while limiting the number of escaping ions. By adjusting the magnitude and timing of the potential well shaping, subsequent shots from the ion beam can be captured on a time scale shorter then that dictated by the standard inject, capture and cool technique. Currently, experimental tests are under way examining the functionally of this system for stacking multiple ions bursts within the HiPAT system.

Martin, James J.↗

Understanding Columbia's Reentry Problems

Soon after the Space Shuttle Columbia accident occurred last year, a group of CFD analysts from NASA centers and private industry was organized to help determine the cause of the accident. This group was under the direction of the Applied Aeroscience and CFD Branch of the Aeroscience and Flight Mechanics Division at the Johnson Space Center. For external flow simulations, noncommercial CFD codes that specialize in hypersonic or high Mach number flows were used. These tools were used to determine heating rates, pressures, and temperatures for a large number of vehicle damage scenarios. Lockheed Martin Space Operations was called upon to provide CFD support in the area of internal flows within the shuttle wing cavity, and or these simulations, FLUENT 6.1 was chosen. Two large-scale, simplified models were run to understand the flow patterns once a breach of the internal wing cavity was initiated. The results were primarily used to visualize flow patterns within the wing cavity. The first CFD model included the entire left wing without the wheel. well cavity. The purpose of the first model, which did not include the reinforced carbon-carbon (RCC) cavity along the wing leading edge, was to visualize the flow field within the wing cavity immediately after the leading edge spar breach, This model assumed that the flow coming into the wing cavity was nom1 to the spar. It included all o f the primary vents that allow for flow between the main cavities of the wing. A six-inch diameter hole was modeled in the spar at the approximate location where the spar breach was judged to have occurred, which was between RCC panels 8 and 9. The results of the modeling showed that at this location, the high temperature, high velocity gas stream entering the wing cavity impinged on the outboard wheel well cavity. Instrumentation in the Shuttle wheel well cavity registered abnormal temperatures during reentry, so the FLUENT results helped support the conclusion of the accident investigation team that the spar breach was in the RCC panel 8-9 area, and that the initial spar breach was likely entering the wing cavity normal to the spar. This model also showed that the flow entering the wing cavity tended to swirl within the cavity just outboard of the wheel well, and did not initially penetrate further into the rear cavities of the wing. The second CFD model was a 2-D simulation of the left wing cavity and the RCC cavity. It was used to visualize the flow through the RCC breach, through the wing spar breach, and into the wing cavity directly outboard of the wheel well. The purpose of this model was to verify whether or not it was possible for the flow to come into the wing cavity normal to the leading edge spar. The results from this 2-D model showed that the internal structure behind the RCC panels probably deflected the flow entering the RCC cavity so that it impinged normal to the spar. As in the 3-D model, this deflected flow stream was found to impinge on the wheel well outer wall. This model again supported the conclusions regarding the location of the spar breach and how the flow behaved inside the wing cavity.

Paul, Thomas H.↗

Understanding Columbia's Reentry Problems

Soon after the Space Shuttle Columbia accident occurred last year, a group of CFD analysts from NASA centers and private industry was organized to help determine the cause of the accident. This group was under the direction of the Applied Aeroscience and CFD Branch of the Aeroscience and Flight Mechanics Division at the Johnson Space Center. For external flow simulations, noncommercia2 CFD codes that specialize in hypersonic or high Mach number flows were used. These tools were used to determine heating rates, pressures, and temperatures for a large number of vehicle damage scenarios. Lockheed Martin Space Operations was called upon to provide CFD support in the area of internal flows within the shuttle wing cavity, and for these simulations, FLUENT 6.1 was chosen. Two large-scale, simplified models were m to understand the flow patterns once a breach of the internal wing cavity was initiated. The results were primarily used to visualize flow patterns within the wing cavity. The first CFD model included the entire lee wing without the wheel well cavity. The purpose of the first model, which did not include the reinforced carbon-carbon (RCC) cavity along the wing leading edge, was to visualize the flow field within the wing cavity immediately after the leading edge spar breach, This model assumed that the flow coming into the wing cavity was normal to the spar. It included all of the primary vents that allow for flow between the main cavities of the wing. A six-inch diameter hole was modeled in the spar at the approximate location where the spar breach was judged to have occurred, which was between RCC panels 8 and 9. The results of the modeling showed that at this location, the high temperature, high velocity gas stream entering the wing cavity impinged on the outboard wheel well cavity. Instrumentation in the Shuttle wheel well cavity registered abnormal temperatures during reentry, so the FLUENT results helped support the conclusion of the accident investigation team that the spar breach was in the RCC panel 8-9 area, and that the initial spar breach was likely entering the wing cavity normal to the spar. This model also showed that the flow entering the wing cavity tended to swirl within the cavity just outboard of the wheel well, and did not initially penetrate further into the rear cavities of the wing. The second CFD model was a 2-D simulation of the left wing cavity and the RCC cavity. It was used to visualize the flow through the RCC breach, through the wing spar breach, and into the wing cavity directly outboard of the wheel well. The purpose of this model was to verify whether or not it was possible for the flow to come into the wing cavity normal to the leading edge spar. The results from this 2-D model showed that the internal structure behind the RCC panels probably deflected the flow entering the RCC cavity so that it impinged normal to the spar. As in the 3-D model, this deflected flow stream was Found to impinge on the wheel well outer wall. This model again supported the conclusions regarding the location of the spar breach and how the flow behaved inside the wing cavity.

Paul, Thomas↗

The Use of RGPS Kinematic Data to Estimate Nonlinear Sea Ice Motion

In current simulations of the interaction between sea ice and its environment, large significance is placed on the deformation of the sea ice. Sea ice deformation is an important process in determining the sea ice thickness distribution across a wide range of space and time scales. Changes in the sea ice thickness distribution affect energy and mass fluxes between the atmosphere and ocean and also the strength of the ice. While most current ice models assume linear variation in the ice motion field to calculate strain, deformation of sea ice occurs through the opening, closing and shearing of ice along discrete linear features. New numerical models are being developed which explicitly account for discontinuities in ice motion, and the need for requisite data sets for model validation has emerged. Multiple buoy data sets, as well as satellite data, have been used to examine the movement and deformation of sea ice. Generally it has been found that the ice motion field has been represented well by buoy data, as well as satellite data over a broad range of scales. However, the underlying deformation (spatial variation in displacement) as represented by different data sets may vary. For the work presented here, sea ice motion In current simulations of the interaction between sea ice and its environment, large significance is placed on the deformation of the sea ice. Sea ice deformation is an important process in determining the sea ice thickness distribution across a wide range of space and time scales. Changes in the sea ice thickness distribution affect energy and mass fluxes between the atmosphere and ocean and also the strength of the ice. While most current ice models assume linear variation in the ice motion field to calculate strain, deformation of sea ice occurs through the opening, closing and shearing of ice along discrete linear features. New numerical models are being developed which explicitly account for discontinuities in ice motion, and the need for requisite data sets for model validation has emerged. Multiple buoy data sets, as well as satellite data, have been used to examine the movement and deformation of sea ice. Generally it has been found that the ice motion field has been represented well by buoy data, as well as satellite data over a broad range of scales. However, the underlying deformation (spatial variation in displacement) as represented by different data sets may vary. For the work presented here, sea ice motio

Pruis, M.↗

Microwell Arrays for Studying Many Individual Cells

"Laboratory-on-a-chip" devices that enable the simultaneous culturing and interrogation of many individual living cells have been invented. Each such device includes a silicon nitride-coated silicon chip containing an array of micromachined wells sized so that each well can contain one cell in contact or proximity with a patch clamp or other suitable single-cell-interrogating device. At the bottom of each well is a hole, typically 0.5 m wide, that connects the well with one of many channels in a microfluidic network formed in a layer of poly(dimethylsiloxane) on the underside of the chip. The microfluidic network makes it possible to address wells (and, thus, cells) individually to supply them with selected biochemicals. The microfluidic channels also provide electrical contact to the bottoms of the wells.

Folch, Albert↗

Self-Referencing Hartmann Test for Large-Aperture Telescopes

A method is proposed for end-to-end, full aperture testing of large-aperture telescopes using an innovative variation of a Hartmann mask. This technique is practical for telescopes with primary mirrors tens of meters in diameter and of any design. Furthermore, it is applicable to the entire optical band (near IR, visible, ultraviolet), relatively insensitive to environmental perturbations, and is suitable for ambient laboratory as well as thermal-vacuum environments. The only restriction is that the telescope optical axis must be parallel to the local gravity vector during testing. The standard Hartmann test utilizes an array of pencil beams that are cut out of a well-corrected wavefront using a mask. The pencil beam array is expanded to fill the full aperture of the telescope. The detector plane of the telescope is translated back and forth along the optical axis in the vicinity of the nominal focal plane, and the centroid of each pencil beam image is recorded. Standard analytical techniques are then used to reconstruct the telescope wavefront from the centroid data. The expansion of the array of pencil beams is usually accomplished by double passing the beams through the telescope under test. However, this requires a well-corrected, autocollimation flat, the diameter or which is approximately equal to that of the telescope aperture. Thus, the standard Hartmann method does not scale well because of the difficulty and expense of building and mounting a well-corrected, large aperture flat. The innovation in the testing method proposed here is to replace the large aperture, well-corrected, monolithic autocollimation flat with an array of small-aperture mirrors. In addition to eliminating the need for a large optic, the surface figure requirement for the small mirrors is relaxed compared to that required of the large autocollimation flat. The key point that allows this method to work is that the small mirrors need to operate as a monolithic flat only with regard to tip/tilt and not piston because in collimated space piston has no effect on the image centroids. The problem of aligning the small mirrors in tip/tilt requires a two-part solution. First, each mirror is suspended from a two-axis gimbal. The orientation of the gimbal is maintained by gravity. Second, the mirror is aligned such that the mirror normal is parallel to gravity vector. This is accomplished interferometrically in a test fixture. Of course, the test fixture itself needs to be calibrated with respect to gravity.

Korechoff, Robert P.↗

InGaP Heterojunction Barrier Solar Cells

A new solar-cell structure utilizes a single, ultra-wide well of either gallium arsenide (GaAs) or indium-gallium-phosphide (InGaP) in the depletion region of a wide bandgap matrix, instead of the usual multiple quantum well layers. These InGaP barrier layers are effective at reducing diode dark current, and photogenerated carrier escape is maximized by the proper design of the electric field and barrier profile. With the new material, open-circuit voltage enhancements of 40 and 100 mV (versus PIN control systems) are possible without any degradation in short-circuit current. Basic tenets of quantum-well and quantum- dot solar cells are utilized, but instead of using multiple thin layers, a single wide well works better. InGaP is used as a barrier material, which increases open current, while simultaneously lowering dark current, reducing both hole diffusion from the base, and space charge recombination within the depletion region. Both the built-in field and the barrier profile are tailored to enhance thermionic emissions, which maximizes the photocurrent at forward bias, with a demonstrated voltage increase. An InGaP heterojunction barrier solar cell consists of a single, ultra-wide GaAs, aluminum-gallium-arsenide (AlGaAs), or lower-energy-gap InGaP absorber well placed within the depletion region of an otherwise wide bandgap PIN diode. Photogenerated electron collection is unencumbered in this structure. InGaAs wells can be added to the thick GaAs absorber layer to capture lower-energy photons.

Welser, Roger E.↗

Development of a Q-band Propagation Campaign in the United States

The imminent saturation of commercial Ka-band services has generated increased interest by the SATCOM industry, as well as NASA (via potential commercially provided SATCOM services), to investigate the use of the Q-band (37-42 GHz) for future space-to-earth communications spectrum utilization. It is well understood that the use of higher frequencies (i.e. , Q-band) offers wider bandwidth, higher data rate services, but an understanding of Q-band performance limitations as they pertain to atmospheric propagation, particularly at NASA and commercial sites of interest, is not well characterized. Thus, the first steps towards system performance determination will be the initiation of a propagation campaign to statistically The imminent saturation of commercial Ka-band services has generated increased interest by the SATCOM industry, as well as NASA (via potential commercially provided SATCOM services), to investigate the use of the Q-band (37-42 GHz) for future space-to-earth communications spectrum utilization. It is well understood that the use of higher frequencies (i .e., Q-band) offers wider bandwidth, higher data rate services, but an understanding of Q-band performance limitations as they pertain to atmospheric propagation, particularly at NASA and commercial sites of interest, is not well characterized. Thus, the first steps towards system performance determination will be the initiation of a propagation campaign to statistically quantify long-term degradation parameters due to the atmosphere. As such, NASA Glenn Research Center (GRC), in collaboration with Space Systems/Loral(SS/L), is leading an effort to characterize Q-band link performance at key sites to determine its potential for use in future space communications architectures. The proposed propagation campaign is divided into phases, beginning with passive radiometric observations in the Q-band, and eventually leading to an active beacon experiment. Herein, we describe the schedule, development, and architecture of the first Q-band propagation campaign being conducted in the US and the proposed objectives of the effort.

Nessel, James A.↗

Spatio-Temporal Variability of Groundwater Storage in India

Groundwater level measurements from 3907 monitoring wells, distributed within 22 major river basins of India, are assessed to characterize their spatial and temporal variability. Ground water storage (GWS) anomalies (relative to the long-term mean) exhibit strong seasonality, with annual maxima observed during the monsoon season and minima during pre-monsoon season. Spatial variability of GWS anomalies increases with the extent of measurements, following the power law relationship, i.e., log-(spatial variability) is linearly dependent on log-(spatial extent).In addition, the impact of well spacing on spatial variability and the power law relationship is investigated. We found that the mean GWS anomaly sampled at a 0.25 degree grid scale closes to unweighted average over all wells. The absolute error corresponding to each basin grows with increasing scale, i.e., from 0.25 degree to 1 degree. It was observed that small changes in extent could create very large changes in spatial variability at large grid scales. Spatial variability of GWS anomaly has been found to vary with climatic conditions. To our knowledge, this is the first study of the effects of well spacing on groundwater spatial variability. The results may be useful for interpreting large scale groundwater variations from unevenly spaced or sparse groundwater well observations or for siting and prioritizing wells in a network for groundwater management. The output of this study could be used to maintain a cost effective groundwater monitoring network in the study region and the approach can also be used in other parts of the globe.

Groundwater monitoring↗

Unmanned Aircraft Systems Minimum Operations Performance Standards End-to-End Verification and Validation (E2-V2) Simulation

As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The current NAS relies on pilot's vigilance and judgement to remain Well Clear (CFR 14 91.113) of other aircraft. RTCA SC-228 has defined DAA Well Clear (DAAWC) to provide a quantified Well Clear volume to allow systems to be designed and measured against. Extended research efforts have been conducted to understand and quantify system requirements needed to support a UAS pilot's ability to remain well clear of other aircraft. The efforts have included developing and testing sensor, algorithm, alerting, and display requirements. More recently, sensor uncertainty and uncertainty mitigation strategies have been evaluated. This paper discusses results and lessons learned from an End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS). NASA Langley Research Center (LaRC) was called upon to develop a system that evaluates a specific set of encounters, in a variety of geometries, with end-to-end DAA functionality including the use of sensor and tracker models, a sensor uncertainty mitigation model, DAA algorithmic guidance in both vertical and horizontal maneuvering, and a pilot model which maneuvers the ownship aircraft to remain well clear from intruder aircraft, having received collective input from the previous modules of the system. LaRC developed a functioning batch simulation and added a sensor/tracker model from the Federal Aviation Administration (FAA) William J. Hughes Technical Center, an in-house developed sensor uncertainty mitigation strategy, and implemented a pilot model similar to one from the Massachusetts Institute of Technology's Lincoln Laboratory (MIT/LL). The resulting simulation provides the following key parameters, among others, to evaluate the effectiveness of the MOPS DAA system: severity of loss of well clear (SLoWC), alert scoring, and number of increasing alerts (alert jitter). The technique, results, and lessons learned from a detailed examination of DAA system performance over specific test vectors and encounter cases during the simulation experiment will be presented in this paper.

Ghatas, Rania W.↗

Validation of Minimum Display Requirements for a UAS Detect and Avoid System

The full integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS), a prerequisite for enabling a broad range of public and commercial UAS operations, presents several technical challenges to UAS developers, operators and regulators. A primary barrier is the inability for UAS pilots (situated at a ground control station, or GCS) to comply with Title 14 Code of Federal Regulations sections 91.111 and 91.113, which require pilots to “see and avoid” other aircraft in order to maintain well clear. UAS pilots’ removal from the flight deck of the aircraft necessitates the development of a UAS-specific system for detecting nearby traffic and displaying traffic information to the pilot to support their ability to maintain an objectively defined “DAA well clear” threshold from other aircraft. This new UAS-specific function of remaining DAA well clear is called traffic avoidance. The resulting Detect and Avoid (DAA) system, however, will be subject to a collection of requirements that manufacturers will be obligated to meet in order to certify their equipment. RTCA Special Committee 228 (SC-228), a consortium of representatives from government, industry and academia, is responsible for developing and documenting the Minimum Operational Performance Standards (MOPS) for UAS DAA systems. The present study is the final in a series of human-in-the-loop (HITL) experiments designed to explore and test the various display and alerting requirements being incorporated into the DAA MOPS. Whereas the prior DAA HITLs examined a wide variety of DAA display features and concepts, the current experiment aims to validate the latest minimum display requirements for Phase 1 of the DAA MOPS. Rather than test different display concepts, this study tests two configurations of a MOPS-compatible DAA display: a version that is integrated into the primary navigation and control display of the GCS and a version that is physically separated from the primary display. This manipulation tests the draft minimum requirement that allows the DAA traffic display to be a separate, or standalone, configuration. This type of configuration is a more achievable near-term technology solution since it does not stipulate additional certification or integration requirements on UAS manufacturers. However, a standalone display configuration has the potential to result in pilot performance issues resulting from the cognitive costs of switching between the primary DAA display and the primary navigation and control display. This configuration is also particularly susceptible to errors if the displays are in different orientations (e.g., north-up versus track-up). Both the integrated and standalone display configurations were presented to 16 active UAS pilots in a medium-fidelity simulation, which included confederate air traffic controllers and pseudo pilots operating simulated manned traffic. Pilots were tasked with navigating two different mission routes while maintaining DAA well clear with scripted conflicts. Pilot response times (i.e., measured response) and ability to remain DAA well clear are reported. Primary results indicate that both display configurations resulted in favorable response times and well clear rates. While there were clear trends of pilots objectively performing better in the integrated display condition, with several measured response metrics reaching statistical significance, the differences between the two displays were typically moderate. While the primary variable of DAA display location did not have an especially large impact on pilot performance on its own, when examined alongside the type of DAA threat the pilot was facing (a caution-level versus a warning-level alert), the response time benefits associated with the integrated display were amplified. The implications of these American Institute of Aeronautics and Astronautics 2 results on the Phase 1 DAA MOPS and the connection of this data to previous studies is also discussed.

detect and avoid↗