Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Predicting Deposition Rate and Closing the Loop on Aerosol Jet Printing with In‐Line Light Scattering Measurements

Aerosol jet printing is a compelling noncontact, digital manufacturing technology for flexible, hybrid, and conformal electronics, but batch‐to‐batch variability and process drift inhibit systematic study and translation to production environments. Emerging measurement techniques for the aerosol volume fraction, a key parameter governing deposition rate, have shown promise for real‐time response, including a recent demonstration of human‐in‐the‐loop control. By integrating improved light scattering measurements with custom software, a robust environment for real‐time monitoring is established and fully automated closed‐loop control over the deposition rate during printing is enabled. The physical basis for scattering measurements as a feedback source is examined and the quantitative insight this provides for ink development and fundamental process studies is highlighted. Three candidate process variables for closed‐loop control, namely the atomizer voltage, carrier gas flow rate, and print speed, are then evaluated. The atomizer voltage demonstrates the best extended duration validity because it addresses atomization variability directly, but carrier gas flow rate and print speed provide faster and more deterministic responses. This methodology is then demonstrated for electrical properties using a silver nanoparticle ink, maintaining 98% of printed patterns within 10% of the mean resistance value over 3 h of printing.

36 MATERIALS SCIENCE↗

Coupling of Ca 2+ and voltage activation in BK channels through the αB helix/voltage sensor interface

Large-conductance Ca 2+ and voltage-activated K + (BK) channels control membrane excitability in many cell types. BK channels are tetrameric. Each subunit is composed of a voltage sensor domain (VSD), a central pore-gate domain, and a large cytoplasmic domain (CTD) that contains the Ca 2+ sensors. While it is known that BK channels are activated by voltage and Ca 2+ , and that voltage and Ca 2+ activations interact, less is known about the mechanisms involved. In this work we explore these mechanisms by examining the gating contribution of an interface formed between the VSDs and the αB helices located at the top of the CTDs. Proline mutations in the αB helix greatly decreased voltage activation while having negligible effects on gating currents. Analysis with the Horrigan, Cui, and Aldrich model indicated a decreased coupling between voltage sensors and pore gate. Proline mutations decreased Ca 2+ activation for both Ca 2+ bowl and RCK1 Ca 2+ sites, suggesting that both high-affinity Ca 2+ sites transduce their effect, at least in part, through the αB helix. Mg 2+ activation also decreased. The crystal structure of the CTD with proline mutation L390P showed a flattening of the first helical turn in the αB helix compared to wild type, without other notable differences in the CTD, indicating that structural changes from the mutation were confined to the αB helix. These findings indicate that an intact αB helix/VSD interface is required for effective coupling of Ca 2+ binding and voltage depolarization to pore opening and that shared Ca 2+ and voltage transduction pathways involving the αB helix may be involved.

59 BASIC BIOLOGICAL SCIENCES↗

The Lick Observatory charge-coupled device /CCD/ and controller

A description is given of a flexible microprocessor-based controller for charge-coupled device two-dimensional detectors. It is noted that the controller can operate under manual control or as a slave to a remote computer linked by coaxial cable. The system is discussed, together with data taken at the telescope and in the laboratory. The flexibility of the controller derives from its modular form and from the use of a programmable 8-bit microprocessor to control and sequence the electronic logic. The electronic circuits for such functions as signal processing, clock sequencing, voltage level adjustment, and temperature control are on small individual plug-in cards, making future improvements and changes simple. The software of the microprocessor is stored in erasable, programmable, read-only memory. Among the limitations of the controller is a scan speed of roughly 35 microsec per pixel.

Robinson, L. B.↗

Hierarchical Control of Distributed Battery Energy Storage System in a DC Microgrid

This paper presents a novel hierarchical control approach of a DC microgrid (DCMG) which is supplied by a distributed battery energy storage system (BESS). With this approach, all battery units distributed in the BESS can be controlled to discharge with accurate current sharing and state-of-charge (SoC) balancing. Similar to other hierarchical control approaches used in DCMGs, this approach consists of three levels: (1) primary control, (2) secondary control and (3) tertiary control. This work includes defining a unit control error (UCE) at the secondary control level and evaluating current sharing weights at tertiary control level. A centralized controller at secondary control level is designed to detect the UCEs of each battery unit, and to restore the average voltage of a DCMG and control battery current sharing simultaneously. The distributed battery units share the load current in a DCMG based on weights. These weights are evaluated at the tertiary control level based on battery SoCs. The approach’s effectiveness was confirmed in digital simulation tests with the same simulation model as used in the NASA AMPS Modular Hardware Emulator.

Jing Zhang↗

A Multilevel DC to Three-phase AC Architecture for Photovoltaic Power Plants

This study presents a photovoltaic (PV) inverter architecture composed of stackable dc to three-phase ac converter blocks. Several such blocks, each containing a converter power stage and controls, are connected in series on their ac sides to obtain transformerless medium-voltage ac interfaces for PV power plants. The series-connected structure is made possible by a quadruple active bridge dc-dc converter that provides isolation between the PV input and each of the three ac-side phases within each block. Furthermore, since incoming PV power is transferred as constant balanced three-phase ac power, instantaneous inputoutput power balance bypasses the need for bulk energy storage. To streamline implementation and maximize system scalability and resilience, decentralized block-level controllers accomplish dc-link voltage regulation, maximum power point tracking, and ac-side power sharing without centralized means. The proposed architecture is validated by simulations of a PV string to mediumvoltage ac system consisting of six blocks and on a proof-of-concept hardware prototype that consists of three cascaded converter blocks.

14 SOLAR ENERGY↗

Breakdown of atmospheric pressure microgaps at high excitation frequencies

Microwave (mw) breakdown of atmospheric pressure microgaps is studied by a one-dimensional Particle-in-Cell Monte Carlo Collisions numerical model. The effect of both field electron emission and secondary electron emission (due to electron impact, ion impact, and primary electron reflection) from surfaces on the breakdown process is considered. For conditions where field emission is the dominant electron emission mechanism from the electrode surfaces, it is found that the breakdown voltage of mw microdischarge coincides with the breakdown voltage of direct-current (dc) microdischarge. When microdischarge properties are controlled by both field and secondary electron emission, breakdown voltage of mw microdischarge exceeds that of dc microdischarge. When microdischarge is controlled only by secondary electron emission, breakdown voltage of mw microdischarge is smaller than that of dc microdischarge. It is shown that if the interelectrode gap exceeds some critical value, mw microdischarge can be ignited only by electrons initially seeded within the gap volume. In addition, the influence of electron reflection and secondary emission due to electron impact is studied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

Resonant tunneling with high peak to valley current ratio in SiO{sub 2}/nc-Si/SiO{sub 2} multi-layers at room temperature

We have investigated carrier transport in SiO{sub 2}/nc-Si/SiO{sub 2} multi-layers by room temperature current-voltage measurements. Resonant tunneling signatures accompanied by current peaks are observed. Carrier transport in the multi-layers were analyzed by plots of ln(I/V{sup 2}) as a function of 1/V and ln(I) as a function of V{sup 1/2}. Results suggest that besides films quality, nc-Si and barrier sub-layer thicknesses are important parameters that restrict carrier transport. When thicknesses are both small, direct tunneling dominates carrier transport, resonant tunneling occurs only at certain voltages and multi-resonant tunneling related current peaks can be observed but with peak to valley current ratio (PVCR) values smaller than 1.5. When barrier thickness is increased, trap-related and even high field related tunneling is excited, causing that multi-current peaks cannot be observed clearly, only one current peak with higher PVCR value of 7.7 can be observed. While if the thickness of nc-Si is large enough, quantum confinement is not so strong, a broad current peak with PVCR value as high as 60 can be measured, which may be due to small energy difference between the splitting energy levels in the quantum dots of nc-Si. Size distribution in a wide range may cause un-controllability of the peak voltages.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900-MHz LTE network↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications: Preprint

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900 MHz LTE network↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Brayton Power Conversion Unit Tested: Provides a Path to Future High-Power Electric Propulsion Missions

Closed-Brayton-cycle conversion technology has been identified as an excellent candidate for nuclear electric propulsion (NEP) power conversion systems. Advantages include high efficiency, long life, and high power density for power levels from about 10 kWe to 1 MWe, and beyond. An additional benefit for Brayton is the potential for the alternator to deliver very high voltage as required by the electric thrusters, minimizing the mass and power losses associated with the power management and distribution (PMAD). To accelerate Brayton technology development for NEP, the NASA Glenn Research Center is developing a low-power NEP power systems testbed that utilizes an existing 2- kWe Brayton power conversion unit (PCU) from previous solar dynamic technology efforts. The PCU includes a turboalternator, a recuperator, and a gas cooler connected by gas ducts. The rotating assembly is supported by gas foil bearings and consists of a turbine, a compressor, a thrust rotor, and an alternator on a single shaft. The alternator produces alternating-current power that is rectified to 120-V direct-current power by the PMAD unit. The NEP power systems testbed will be utilized to conduct future investigations of operational control methods, high-voltage PMAD, electric thruster interactions, and advanced heat rejection techniques. The PCU was tested in Glenn s Vacuum Facility 6. The Brayton PCU was modified from its original solar dynamic configuration by the removal of the heat receiver and retrofitting of the electrical resistance gas heater to simulate the thermal input of a steady-state nuclear source. Then, the Brayton PCU was installed in the 3-m test port of Vacuum Facility 6, as shown. A series of tests were performed between June and August of 2002 that resulted in a total PCU operational time of about 24 hr. An initial test sequence on June 17 determined that the reconfigured unit was fully operational. Ensuing tests provided the operational data needed to characterize PCU performance over its full operating range. The primary test variables used in operating the Brayton PCU were heater input power and rotor speed. Testing demonstrated a maximum steady-state alternating-current power output of 1835 W at a gas heater power of 9000 W and a rotor speed of 52000 rpm. The corresponding measured turbine inlet gas temperature was 1076 K, and the compressor inlet gas temperature was 282 K. When insulation losses from the gas heater were neglected, the Brayton cycle efficiency for the maximum power point was calculated to be 24 percent. The net direct-current power output was 1750 W, indicating a PMAD efficiency of about 95 percent.

Mason, Lee S.↗

Quantitative Trade-Off in Distributed Secondary Control for Autonomous AC Microgrids

In this paper, we propose to quantify the trade-off between voltage regulation and reactive power sharing in autonomous AC microgrids with distributed secondary control. It is known that voltage regulation and reactive power sharing in droop-controlled autonomous AC microgrids are two conflicting control objectives that present a natural trade-off between voltage regulation towards the voltage magnitude reference and reactive power sharing accuracy. This trade-off is commonly shown qualitatively without sufficient quantification. In this work, to quantify the trade-off between the two objectives, we focus on distributed secondary control and utilize regression and polynomial surface fitting to identify the requisite parameter area to satisfy the predefined error bands for voltage magnitude regulation and reactive power sharing. Extensive case studies are presented to validate the proposed method.

autonomous AC microgrids↗

Closed Loop solar array-ion thruster system with power control circuitry

A power control circuit connected between a solar array and an ion thruster receives voltage and current signals from the solar array. The control circuit multiplies the voltage and current signals together to produce a power signal which is differentiated with respect to time. The differentiator output is detected by a zero crossing detector and, after suitable shaping, the detector output is phase compared with a clock in a phase demodulator. An integrator receives no output from the phase demodulator when the operating point is at the maximum power but is driven toward the maximum power point for non-optimum operation. A ramp generator provides minor variations in the beam current reference signal produced by the integrator in order to obtain the first derivative of power.

Gruber, R. P.↗

Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint

Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.

current limiting↗

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Coordination of Networked Microgrids for Voltage Support in Bulk Power Grids

The increasing deployment of distributed energy resources (DERs) and microgrids (MGs) in power distribution systems has enabled the adjustment of reactive power consumption as seen at the substation, which can be used to provide voltage support for the bulk power system (BPS). Leveraging this new capability will provide greater resiliency to the power system as a whole. Here, the goal of this paper is to develop and compare three different algorithms, namely distributed optimal power flow, distributed consensus algorithm, and fully decentralized collaborative autonomy for unbalanced distribution systems for microgrid coordination. These algorithms use networked MGs to support the BPS voltage when a contingency at the bulk grid results in abnormally low voltages, which may be a precursor to voltage collapse. Our comparative analysis includes both qualitative and quantitative assessments of the three algorithms and a discussion of the trade-offs between the decentralized and distributed methods in normal and disrupted conditions. Each algorithm was evaluated on the modified IEEE 13-bus system and a real power distribution system at Chattanooga, Tennessee, that encompasses more than 4500 buses. Each algorithms excels differently and may be suited for different scenarios depending on the condition, operations, and priorities of the power and communication systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗