Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model

Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% {+-} 8.43% at 12 weeks in BNS versus 39.77% {+-} 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 {+-} 1.17 versus 2.17 {+-} 0.85 in BNS. The results for vessel wall injury (0.6 {+-} 0.58 for Polyzene-F-coated stents; 0.72 {+-} 0.98 for BNS) and re-endothelialization, (1.16 {+-} 0.43 and 1.23 {+-} 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies ({>=}120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lymphangiography and Post-lymphangiographic Multidetector CT for Preclinical Lymphatic Interventions in a Rabbit Model

Purpose: To describe the feasibility of lymphangiography and the visibility of the lymphatic system using post-lymphangiographic multidetector CT (MDCT) for preclinical lymphatic interventions in a rabbit model. Materials and Methods: Lymphangiography via the popliteal lymph node or vessel after surgical exposure was performed, using six healthy female Japanese White rabbits. Lipiodol was manually injected for lymphangiography. Post-lymphangiographic MDCT examinations were performed in all rabbits. The dataset images were subjected to image processing analysis utilizing the three-dimensional maximum intensity projection technique. Three reviewers evaluated the degree of depiction of the lymphatic system using a four-point visual score (1, poor; 2, fair; 3, good; 4, excellent). The distance between the body surface and cisterna chyli was measured on post-lymphangiographic MDCT axial image. Results: Lymphangiography was successfully performed in all rabbits. The popliteal lymph node was detectable in 90%. The visualization of lymphatic system via the popliteal node was achieved in 89%. Mean visual scores of > 3.0 were realized by the right femoral lymphatic vessel, left femoral lymphatic vessel, left iliac lymphatic vessel, left lumbar lymphatic trunks and cisterna chyli, whereas mean visual scores of < 3.0 were yielded by the right iliac lymphatic vessel, right lumbar lymphatic trunks and thoracic duct. The distance between the body surface and cisterna chyli on post-lymphangiographic MDCT axial images was 4.33 ± 0.14 cm. Conclusion: Lymphangiography is feasible, and the visibility of the lymphatic system on post-lymphangiographic MDCT in a rabbit model provides enough information for interventional radiologists to perform preclinical lymphatic interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer Modeling of Yttrium-90-Microsphere Transport in the Hepatic Arterial Tree to Improve Clinical Outcomes

Purpose: Radioembolization (RE) via yttrium-90 ({sup 90}Y) microspheres is an effective and safe treatment for unresectable liver malignancies. However, no data are available regarding the impact of local blood flow dynamics on {sup 90}Y-microsphere transport and distribution in the human hepatic arterial system. Methods and Materials: A three-dimensional (3-D) computer model was developed to analyze and simulate blood-microsphere flow dynamics in the hepatic arterial system with tumor. Supplemental geometric and flow data sets from patients undergoing RE were also available to validate the accuracy of the computer simulation model. Specifically, vessel diameters, curvatures, and branching patterns, as well as blood flow velocities/pressures and microsphere characteristics (i.e., diameter and specific gravity), were measured. Three-dimensional computer-aided design software was used to create the vessel geometries. Initial trials, with 10,000 noninteracting microspheres released into the hepatic artery, used resin spheres 32-{mu}m in diameter with a density twice that of blood. Results: Simulations of blood flow subject to different branch-outlet pressures as well as blood-microsphere transport were successfully carried out, allowing testing of two types of microsphere release distributions in the inlet plane of the main hepatic artery. If the inlet distribution of microspheres was uniform (evenly spaced particles), a greater percentage would exit into the vessel branch feeding the tumor. Conversely, a parabolic inlet distribution of microspheres (more particles around the vessel center) showed a high percentage of microspheres exiting the branch vessel leading to the normal liver. Conclusions: Computer simulations of both blood flow patterns and microsphere dynamics have the potential to provide valuable insight on how to optimize {sup 90}Y-microsphere implantation into hepatic tumors while sparing normal tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanisms for microvascular damage induced by ultrasound-activated microbubbles

To provide insight into the mechanisms of microvascular damage induced by ultrasound-activated microbubbles, experimental studies were performed to correlate microvascular damage to the dynamics of bubble-vessel interactions. High-speed photomicrography was used to record single microbubbles interacting with microvessels in ex vivo tissue, under the exposure of short ultrasound pulses with a center frequency of 1 MHz and peak negative pressures (PNP) ranging from 0.8-4 MPa. Vascular damage associated with observed bubble-vessel interactions was either indicated directly by microbubble extravasation or examined by transmission electron microscopy (TEM) analyses. As observed previously, the high-speed images revealed that ultrasound-activated microbubbles could cause distention and invagination of adjacent vessel walls, and could form liquid jets in microvessels. Vessel distention, invagination, and liquid jets were associated with the damage of microvessels whose diameters were smaller than those of maximally expanded microbubbles. However, vessel invagination appeared to be the dominant mechanism for the damage of relative large microvessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans

Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic thorax phantom, acquired with a second generation dual source CT scanner. The methods differed by the way information on the presence of bone was obtained (either by using an additional, nonenhanced scan or by scanning with two tube voltages at the same time) and by the way the bone was removed from the CTA images (either by masking or subtracting the bone). The phantom contained parts which mimic vessels of various diameters in direct contact with bone. Both a quantitative and qualitative analysis of image quality after bone removal was performed. Image quality was quantified by the contrast-to-noise ratio (CNR) normalized to the square root of the dose (CNRD). At locations where vessels touch bone, the quality of the bone removal and the vessel preservation were visually assessed. The dual energy based methods were assessed with and without the addition of a 0.4 mm tin filter to the high voltage x-ray tube filtration. For each bone removal method, the dose required to obtain a certain CNR after bone removal was compared with the dose of a reference scan with the same CNR but without automated bone removal. The CNRD value of the reference scan was maximized by choosing the lowest tube voltage available. Results: All methods removed the bone completely. CNRD values were higher for the masking based methods than for the subtraction based methods. Single energy based methods had a higher CNRD value than the corresponding dual energy based methods. For the subtraction based dual energy method, tin filtration improved the CNRD value with approximately 50%. For the masking based dual energy method, it was easier to differentiate between iodine and bone when tin filtration was applied. The CNRD value decreased only with 4% in that case. Compared to the dual scan based methods, the dual energy based methods had the advantage that only a single scan was made without the need of image registration. This might be easier to implement in clinical practice. Vessel preservation was better with bone subtraction than with bone masking. Smaller vessels were completely occluded by the bone mask. None of the bone removal methods was dose neutral. Conclusions: In general, dual scan based methods that use the lowest tube voltage available, have a higher CNR than the dual energy based approaches at the same dose level. Tin filtration improves the ability to differentiate between iodine and bone for the dual energy based masking method. In clinical practice, the advantages of the dual energy masking method might outweigh its disadvantage of a slightly higher dose penalty compared to the conventional dual scan masking method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmarking of Probabilistic Fracture Mechanics Models in Grizzly

In 2020, as part of contract/task order 31310019N0006/31310020F0060, the Nuclear Regulatory Commission tasked Idaho National Laboratory (INL) with benchmarking the MOOSE/GRIZZLY code against the NRC’s Fracture Analysis of Vessels - Oak Ridge (FAVOR), version 16.1 code. Both codes can predict large light-water reactor vessel integrity deterministically and probabilistically. In fact, such predictions are the primary purpose of the FAVOR code, and are a main focus of the GRIZZLY code, although GRIZZLY is capable of modeling a wider range of geometries and problems. The vessel integrity modeling capabilities of the GRIZZLY code are still under development and being gradually expanded, and the capability to model vessel fracture by crack growth has not yet been integrated into GRIZZLY (although it does exist in pre-release versions). Thus, the present benchmark study focused on comparing predictions for the conditional probability of crack growth initiation (CPI) between GRIZZLY and FAVOR v16.1. The present benchmarking study expands on a previous study completed in 2020, which focused on single plate regions, various flaw types, and full vessel studies. The previous study was limited in scope and revealed some relatively large discrepancies, particularly in the case of weld regions. In the present study, detailed investigations into the sources of discrepancies between GRIZZLY and FAVOR were performed, with a focus on weld regions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PR-EDB: Power Reactor Embrittlement Database - Version 3

The aging and degradation of light-water reactor pressure vessels is of particular concern because of their relevance to plant integrity and the magnitude of the expected irradiation embrittlement. The radiation embrittlement of reactor pressure vessel materials depends on many factors, such as neutron fluence, flux, and energy spectrum, irradiation temperature, and preirradiation material history and chemical compositions. These factors must be considered to reliably predict pressure vessel embrittlement and to ensure the safe operation of the reactor. Large amounts of data from surveillance capsules are needed to develop a generally applicable damage prediction model that can be used for industry standards and regulatory guides. Furthermore, the investigations of regulatory issues such as vessel integrity over plant life, vessel failure, and sufficiency of current codes, Standard Review Plans (SRPs), and Guides for license renewal can be greatly expedited by the use of a well-designed computerized database. The Power Reactor Embrittlement Database (PR-EDB) is such a comprehensive collection of data for U.S. designed commercial nuclear reactors. The current version of the PR-EDB lists the test results of 104 heat-affected-zone (HAZ) materials, 115 weld materials, and 141 base materials, including 103 plates, 35 forgings, and 3 correlation monitor materials that were irradiated in 321 capsules from 106 commercial power reactors. The data files are given in dBASE format and can be accessed with any personal computer using the Windows operating system. "User-friendly" utility programs have been written to investigate radiation embrittlement using this database. Utility programs allow the user to retrieve, select and manipulate specific data, display data to the screen or printer, and fit and plot Charpy impact data. The PR-EDB Version 3.0 upgrades Version 2.0. The package was developed based on the Microsoft .NET framework technology and uses Microsoft Access for backend data storage, and Microsoft Excel for plotting graphs. This software package is compatible with Windows (98 or higher) and has been built with a highly versatile user interface. PR-EDB Version 3.0 also contains an "Evaluated Residual File" utility for generating the evaluated processed files used for radiation embrittlement study.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technical Review Report for the Model 9978-96 Package Safety Analysis Report for Packaging (S-SARP-G-00002, Revision 1, March 2009)

This Technical Review Report (TRR) documents the review, performed by Lawrence Livermore National Laboratory (LLNL) Staff, at the request of the Department of Energy (DOE), on the 'Safety Analysis Report for Packaging (SARP), Model 9978 B(M)F-96', Revision 1, March 2009 (S-SARP-G-00002). The Model 9978 Package complies with 10 CFR 71, and with 'Regulations for the Safe Transport of Radioactive Material-1996 Edition (As Amended, 2000)-Safety Requirements', International Atomic Energy Agency (IAEA) Safety Standards Series No. TS-R-1. The Model 9978 Packaging is designed, analyzed, fabricated, and tested in accordance with Section III of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME B&PVC). The review presented in this TRR was performed using the methods outlined in Revision 3 of the DOE's 'Packaging Review Guide (PRG) for Reviewing Safety Analysis Reports for Packages'. The format of the SARP follows that specified in Revision 2 of the Nuclear Regulatory Commission's Regulatory Guide 7.9, i.e., 'Standard Format and Content of Part 71 Applications for Approval of Packages for Radioactive Material'. Although the two documents are similar in their content, they are not identical. Formatting differences have been noted in this TRR, where appropriate. The Model 9978 Packaging is a single containment package, using a 5-inch containment vessel (5CV). It uses a nominal 35-gallon drum package design. In comparison, the Model 9977 Packaging uses a 6-inch containment vessel (6CV). The Model 9977 and Model 9978 Packagings were developed concurrently, and they were referred to as the General Purpose Fissile Material Package, Version 1 (GPFP). Both packagings use General Plastics FR-3716 polyurethane foam as insulation and as impact limiters. The 5CV is used as the Primary Containment Vessel (PCV) in the Model 9975-96 Packaging. The Model 9975-96 Packaging also has the 6CV as its Secondary Containment Vessel (SCV). In comparison, the Model 9975 Packagings use Celotex{trademark} for insulation and as impact limiters. To provide a historical perspective, it is noted that the Model 9975-96 Packaging is a 35-gallon drum package design that has evolved from a family of packages designed by DOE contractors at the Savannah River Site. Earlier package designs, i.e., the Model 9965, the Model 9966, the Model 9967, and the Model 9968 Packagings, were originally designed and certified in the early 1980s. In the 1990s, updated package designs that incorporated design features consistent with the then-newer safety requirements were proposed. The updated package designs at the time were the Model 9972, the Model 9973, the Model 9974, and the Model 9975 Packagings, respectively. The Model 9975 Package was certified by the Packaging Certification Program, under the Office of Safety Management and Operations. The Model 9978 Package has six Content Envelopes: C.1 ({sup 238}Pu Heat Sources), C.2 ( Pu/U Metals), C.3 (Pu/U Oxides, Reserved), C.4 (U Metal or Alloy), C.5 (U Compounds), and C.6 (Samples and Sources). Per 10 CFR 71.59 (Code of Federal Regulations), the value of N is 50 for the Model 9978 Package leading to a Criticality Safety Index (CSI) of 1.0. The Transport Index (TI), based on dose rate, is calculated to be a maximum of 4.1.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial Results from the High Fluence UCSB ATR-2 Irradiation

A primary focus of the Department of Energy, Office of Nuclear Energy Light Water Reactor Sustainability Program (LWRSP) is the safe operation of nuclear reactors to extended lifetimes of up to 80 years. One of the primary reactor components of concern is the reactor pressure vessel (RPV), which is increasingly embrittled over time due to damage from high energy neutrons created in the reactor core. Radiation damage leads to the formation of nm-scale precipitates and solute-defect clusters, which result in an increase in the steel's ductile to brittle transition temperature. Transition temperature shifts (TTS) are used to quantify and regulate embrittlement. Extended life operation will subject some RPVs to higher neutron fluences than previously experienced by in-service vessels. Thus, robust prediction methods must be developed that ensure the safety of our nation's fleet of reactors. Current models underpredict embrittlement data from high flux test reactor irradiations at extended life fluences. It has been hypothesized that one reason for this underprediction is the formation of so-called 'Late- Blooming Phase' Mn-Ni-Si precipitates, which form and grow only at high fluence and that are currently not included in regulatory models. Recent research has demonstrated the existence of high volume fractions of intermetallic Mn-Ni-Si precipitate (MNSP) phases at high fluence and have generated significant insight into their character. However, a number of questions remain regarding MNSPs, such as: 1) what alloys are most susceptible to MNSP formation; 2) how is MNSP formation affected by flux (φ), fluence (φt) and irradiation temperature (T{sub irr}); and, 3) how to accurately predict TTS under extended life low flux service conditions? The fact that no two RPVs are exactly the same, both in terms of the steel composition and vessel service conditions, makes these questions particularly difficult to answer. Further, understanding the effect of flux differences between test reactor irradiations and in-vessel service is absolutely critical. Hence, physical models must be developed that predict TTS as a function of alloy solute content and vessel service conditions. A large-scale irradiation designed to develop and validate an extended life embrittlement prediction model was recently completed in the Advanced Test Reactor (ATR) at the Idaho National Laboratory as part of the DOE sponsored Nuclear Scientific User Facilities. This experiment, called the UCSB ATR-2 irradiation, is a collaboration between Oak Ridge National Lab (ORNL) and the University of California, Santa Barbara (UCSB) and is now primarily supported by the DOE Light Water Reactor Sustainability Program. The experiment is designed to investigate the single and combined effects of neutron φ, φt, T{sub irr} and alloy chemistry on precipitate formation, hardening and embrittlement. While postirradiation examinations (PIE) is ongoing, and is expected to take several years to complete, the first preliminary results are presented below. It should also be noted that Rolls-Royce has been a collaborator in UCSB ATR-2 from the start, and there are several other national and international institutions supporting the PIE. (authors)

36 MATERIALS SCIENCE↗

Heavy Water Components Test Reactor Decommissioning - Major Component Removal

The Heavy Water Components Test Reactor (HWCTR) facility (Figure 1) was built in 1961, operated from 1962 to 1964, and is located in the northwest quadrant of the Savannah River Site (SRS) approximately three miles from the site boundary. The HWCTR facility is on high, well-drained ground, about 30 meters above the water table. The HWCTR was a pressurized heavy water test reactor used to develop candidate fuel designs for heavy water power reactors. It was not a defense-related facility like the materials production reactors at SRS. The reactor was moderated with heavy water and was rated at 50 megawatts thermal power. In December of 1964, operations were terminated and the facility was placed in a standby condition as a result of the decision by the U.S. Atomic Energy Commission to redirect research and development work on heavy water power reactors to reactors cooled with organic materials. For about one year, site personnel maintained the facility in a standby status, and then retired the reactor in place. In 1965, fuel assemblies were removed, systems that contained heavy water were drained, fluid piping systems were drained, deenergized and disconnected and the spent fuel basin was drained and dried. The doors of the reactor facility were shut and it wasn't until 10 years later that decommissioning plans were considered and ultimately postponed due to budget constraints. In the early 1990s, DOE began planning to decommission HWCTR again. Yet, in the face of new budget constraints, DOE deferred dismantlement and placed HWCTR in an extended surveillance and maintenance mode. The doors of the reactor facility were welded shut to protect workers and discourage intruders. The $1.6 billion allocation from the American Recovery and Reinvestment Act to SRS for site clean up at SRS has opened the doors to the HWCTR again - this time for final decommissioning. During the lifetime of HWCTR, 36 different fuel assemblies were tested in the facility. Ten of these experienced cladding failures as operational capabilities of the different designs were being established. In addition, numerous spills of heavy water occurred within the facility. Currently, radiation and radioactive contamination levels are low within HWCTR with most of the radioactivity contained within the reactor vessel. There are no known insults to the environment, however with the increasing deterioration of the facility, the possibility exists that contamination could spread outside the facility if it is not decommissioned. An interior panoramic view of the ground floor elevation taken in August 2009 is shown in Figure 2. The foreground shows the transfer coffin followed by the reactor vessel and control rod drive platform in the center. Behind the reactor vessel is the fuel pool. Above the ground level are the polar crane and the emergency deluge tank at the top of the dome. Note the considerable rust and degradation of the components and the interior of the containment building. Alternative studies have concluded that the most environmentally safe, cost effective option for final decommissioning is to remove the reactor vessel, steam generators, and all equipment above grade including the dome. Characterization studies along with transport models have concluded that the remaining below grade equipment that is left in place including the transfer coffin will not contribute any significant contamination to the environment in the future. The below grade space will be grouted in place. A concrete cover will be placed over the remaining footprint and the groundwater will be monitored for an indefinite period to ensure compliance with environmental regulations. The schedule for completion of decommissioning is late FY2011. This paper describes the concepts planned in order to remove the major components including the dome, the reactor vessel (RV), the two steam generators (SG), and relocating the transfer coffin (TC).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mid–height seismic isolation of equipment in nuclear power plants

An innovative seismic isolation solution for designers of safety-class equipment in advanced nuclear power plants is introduced. The test specimen was a tall, slender, carbon steel vessel that could represent a reactor vessel, steam generator, or a heat exchanger in a nuclear power plant: 240 inches tall, outer diameter of 60 inches, and wall thickness of 1 inch. The vessel was supported by three radial mounts at its mid-height, near its center of gravity, on a steel frame. The vessel was subjected to three-component ground motions using a 6DOF earthquake simulator. The specimen was filled with water for testing to indirectly account for the fluid and internal equipment present inside a prototype vessel. Three configurations were tested: non-isolated, isolated using single Friction Pendulum (SFP) bearings, and isolated using triple Friction Pendulum (TFP) bearings. The test results demonstrate that mid-height seismic isolation is practical and enables a significant reduction in horizontal spectral accelerations. Furthermore, these outcomes are not specific to the spherical sliding bearings used in the experiments but are broadly applicable to mid-height, seismically isolated equipment.

42 ENGINEERING↗

Arterial Distribution of Calibrated Tris-Acryl Gelatin and Polyvinyl Alcohol Embolization Microspheres in Sheep Uterus

The purpose of this study was to compare, after embolization, the distribution in the uterine arterial vasculature of tris-acryl gelatin microspheres (TGMS) and polyvinyl alcohol microspheres (PVAMS). A limited bilateral uterine artery embolization was performed in six adult sheep under fluoroscopic control by injecting in each uterine artery 0.25 ml of 500- to 700-{mu}m TGMS of PVAMS suspended in 50/50 saline/contrast medium. Sacrifices were performed 1 week after embolization and uteri were analyzed histologically. The number and size of microspheres and vessels were measured, as well as the histological location according to a classification in four zones of the uterus. One hundred sixty-five vessels (69 vessels occluded with TGMS and 96 vessels occluded with PVAMS) were measured. The size of the occluded vessels decreased significantly from proximal to distal zones of the uterine vasculature (P < 0.0001). The location of TGMS and PVAMS within the vasculature was significantly different (P < 0.0001) since PVAMS blocked significantly more distally than TGMS. Deformation of the microspheres within the tissue was greater for PVAMS (18.0% {+-} 12.3%) than for TGMS (8.7% {+-} 9.2%) (P < 0.0001). In conclusion, PVAMS have a more distal distribution in the sheep uterine vasculature, compared to TGMS. Such differences in partition, already described in the kidney embolization model, can ultimately explain the different clinical outcome reported with these two types of microspheres in uterine fibroid embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Revascularization for Acute Ischemic Stroke: A Single-Center, Retrospective Analysis

BackgroundEndovascular mechanical revascularization (thrombectomy) is an increasingly used method for intracranial large vessel recanalization in acute stroke. The purpose of the study was to analyze the recanalization rate, clinical outcome, and complication rate in our stroke patients treated with mechanical revascularization. A total of 57 patients with large vessel stroke (within 3 h for anterior and 12 h for posterior circulation) were treated with mechanical revascularization at a single center during 24 months. The primary goal of endovascular treatment using different mechanical devices was recanalization of the occluded vessel. Recanalization rate (reported as thrombolysis in cerebral infarction [TICI] score), clinical outcome (reported as National Institutes of Health Stroke Scale [NIHSS] score and modified Rankin scale [mRS] score), as well as periprocedural complications were analyzed. The mean age of the patients was 63.1 {+-} 12.9 years, with baseline median NIHSS score of 14 (interquartile range, 9.5-19). Successful recanalization (TICI 2b or 3) was achieved in 41 (72 %) patients. Twenty patients (35 %) presented with favorable outcome (mRS {<=}2) 30 days after stroke. Overall, significant neurological improvement ({>=}4 NIHSS point reduction) occurred in 36 (63 %) patients. A clinically significant procedure-related adverse events (vessel disruption, peri/postprocedural intracranial bleeding) defined with decline in NIHSS of {>=}4 or death occurred in three (5 %) patients. The study showed a high recanalization rate with improved clinical outcome and a low rate of periprocedural complications in our stroke patients treated with mechanical revascularization. Therefore, we could conclude that endovascular revascularization (primary or in combination with a bridging thrombolysis) was an effective and safe procedure for intracranial large vessel recanalization in acute stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Occlusion Device: Application of the ArtVentive Endoluminal Occlusion System (EOS)—First in Human Clinical Trial

Purpose: The purpose of this study was to determine the safety and efficacy of a new endoluminal occlusion device, ArtVentive endoluminal occlusion system (EOS), to occlude the spermatic vein in symptomatic males with varicoceles. Methods: The ArtVentive EOS device has been developed for percutaneous, peripheral occlusion of the peripheral arterial and venous vasculature. The system is comprised of an implantable occlusion device and a delivery catheter. At present, there are two device sizes: (a) size 1 for target vessels ranging between 3.5 and 5.5 mm in diameter, and (b) size 2 for target vessels 5.5–8.5 mm in diameter. The treatment group included six adult males, ages 22–34 years. Nine target vessels were occluded. A total of 20 devices were implanted in six subjects. Results: The acute occlusion rate at the end of the procedure was 100 % occurring in nine of nine vessels. The spermatic veins of all patients remained occluded on venography at 30 days follow-up. Pain scores related to varicoceles decreased in five of six patients. Conclusions: Although we recognize this study is limited, initial experience indicates that the ArtVentive EOS is a safe and effective new device for occlusion of vessels (varicoceles). The device has potential applications in other clinical conditions requiring occlusion of veins or arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A heat and mass transfer model for evaluation of damaged cesium chloride radiological sources

Radiological sources are vital to many applications, and typically contain byproducts from waste streams which decay over time to form complex mixtures of elements. Daughter products resulting from these decay processes can introduce complicating factors to the integrity and safety of the vessel that contains the radiological material. Sources containing cesium 137 ( 137 Cs) are of particular interest, because the decay of this isotope produces barium metal which reacts readily and exothermically with oxygen. This work employs physics-based numerical tools to examine the thermal response of a radiological source containing a mixture of cesium and barium in the event that vessel walls are damaged and atmospheric gases contact source material. A parametric study was conducted to determine the sensitivity of the response to various factors, including vessel geometry, source material age, the degree of vessel damage, and other parameters. Here, it was found that the peak temperatures that occurred within the source material strongly depend on these parameters, particularly vessel geometry and age, which determine whether a breach would be a relatively minor accident or a catastrophic incident. Finally, the model’s sensitivity to uncertain thermophysical properties is discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Vascular smooth cell proliferation in perfusion culture of porcine carotid arteries

Objective of this study was to develop a novel in vitro artery culture system to study vascular smooth muscle cell (SMC) proliferation of porcine carotid arteries in response to injury, basic fibroblast growth factor (FGF2), and FGF2 conjugated with cytotoxin saporin (SAP). Perfusion-cultured porcine carotid arteries remained contractile in response to norepinephrine and relaxant to acetylcholine for up to 96 h. SMC proliferation of cultured arteries was detected by bromodeoxyuridine incorporation in both non-injured and balloon-injured arteries. In the inner layer of the vessel wall near the lumen, SMC proliferation were less than 10% in uninjured vessels, 66% in injured vessels, 80% in injured vessels with FGF2 treatment, and 5% in injured vessels with treatment of FGF2-SAP. Thus, the cultured porcine carotid arteries were viable; and the injury stimulated SMC proliferation, which was significantly enhanced by FGF2 and inhibited by FGF2-SAP.

60 APPLIED LIFE SCIENCES↗