Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “user study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Building Toxic Metal Characterization and Decontamination Report: Area 6, Building 914

The purpose of this report is to outline the toxic metal characterization and decontamination efforts in Area 6, Building 914. This includes the initial building inspection, the hotspot sampling, results/findings, building cleanup, and the verification sampling. Building 914 is a steel light frame building that was constructed in 1992. It is about 16,454 square feet, and five employees are assigned to this building. According to the building's floor plan blueprints, it could be inferred that this building was once a Wiremen/Lineman shop. In 2002-2004, the National Nuclear Security Administration Nevada Site Office embarked on a broad characterization of beryllium (Be) surface concentrations throughout the North Las Vegas Facility, the Nevada National Security Site (NNSS), and ancillary facilities like the Special Technologies Laboratory, Remote Sensing Laboratory, etc. Building 914 was part of this characterization. The results of the 2002 study illustrated that the metal housekeeping limits were within acceptable limits and from a Be standpoint, the building was determined to be fit for occupancy. On March 2, 2011, based on a request from Building 914 users, National Security Technologies, LLC (NSTec) Industrial Hygiene (IH) collected bulk samples from the southwest corner of Building 914 at heights above 6 feet where black dust had been noticed on this particular wall. IH conducted surface swipe sampling of the area and analyzed the samples for toxic metals, namely, beryllium (Be), cadmium (Cd), chromium (Cr), lead (Pb), and manganese (Mn). The sample results indicated values two to four times above the housekeeping threshold for Be, Cd, Cr, Pb, and Mn. Subsequently, the facility was closed and posted; the necessary personnel were notified; and controls were instituted for ingress and egress of the building. On March 17, 2011, IH performed an extensive sampling event involving the entire warehouse in accordance with NSTec Organization Procedure OP-P250.004, Sampling Procedures. Analysis of the results from this exercise illustrated that toxic metal contamination was ubiquitous throughout the warehouse section of this building but did not extend into the office, restroom, and break room areas. On March 22, 2011, a planning meeting was held with Environment, Safety, Health & Quality management; Operations & Infrastructure (O&I) mangement; Facility Management; Occupational Medicine; O&I Operations; and IH. After a brief discussion concerning the salient facts of the surface sample results, it was agreed that the facility and its contents required cleaning. The facility would then be re-sampled to verify cleanliness and suitability for re-occupancy. On April 18, 2011, warehouse cleanup activites began. On July 5, 2011, upon receipt of the results from the last cleaned section, the cleanup operations were concluded. The building was statistically determined to be clean; thus, it could be reoccupied and the warehouse operations could resume immediately.

54 ENVIRONMENTAL SCIENCES↗

Development of a Scale Model for High Flux Isotope Reactor Cycle 400

The development of a comprehensive SCALE computational model for the High Flux Isotope Reactor (HFIR) is documented and discussed in this report. The SCALE model has equivalent features and functionality as the reference MCNP model for Cycle 400 that has been used extensively for HFIR safety analyses and for HFIR experiment design and analyses. Numerical comparisons of the SCALE and MCNP models for the multiplication constant, power density distribution in the fuel, and neutron fluxes at several locations in HFIR indicate excellent agreement between the results predicted with the two models. The SCALE HFIR model is presented in sufficient detail to provide the users of the model with a tool that can be easily customized for various safety analysis or experiment design requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Energy Performance Testing of Asetek's RackCDU System at NREL's High Performance Computing Data Center

In this study, we report on the first tests of Asetek's RackCDU direct-to-chip liquid cooling system for servers at NREL's ESIF data center. The system was simple to install on the existing servers and integrated directly into the data center's existing hydronics system. The focus of this study was to explore the total cooling energy savings and potential for waste-heat recovery of this warm-water liquid cooling system. RackCDU captured up to 64% of server heat into the liquid stream at an outlet temperature of 89 degrees F, and 48% at outlet temperatures approaching 100 degrees F. This system was designed to capture heat from the CPUs only, indicating a potential for increased heat capture if memory cooling was included. Reduced temperatures inside the servers caused all fans to reduce power to the lowest possible BIOS setting, indicating further energy savings potential if additional fan control is included. Preliminary studies manually reducing fan speed (and even removing fans) validated this potential savings but could not be optimized for these working servers. The Asetek direct-to-chip liquid cooling system has been in operation with users for 16 months with no necessary maintenance and no leaks.

97 MATHEMATICS AND COMPUTING↗

Delivery of Dynamic Thermal Energy Storage Models and Advanced Reactor Concept Models to the HYBRID Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), sodium fast reactor (SFR), compressed air energy storage (CAES), liquid air energy storage (LAES) and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed. Also detailed in this report are future development goals for the HYBRID repository including adding suites of steady-state models, economic costing information, and reduced-order models. By adding these models in addition to the physical transient models currently existing within HYBRID, HYBRID will be a fully integrable tool for FORCE users.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Convective Parameters Derived from Radiosonde Data (SONDEPARAM) Value-Added Product Report

Radiosondes provide fundamental observations of the vertical profile of atmospheric state (pressure, temperature, humidity, and winds), with important implications for subsequent studies on environmental controls on cloud conditions. Within convective cloud environments, there is an increasing demand for additional value-added products (VAPs) to facilitate the use of U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility radiosonde data sets. Such VAPs should provide quick and reliable estimates for several standard radiosonde parameters or quantities of interest using common assumptions, as well as open, flexible code for visualization and user interaction. The Convective Parameters Derived from Radiosonde Data (SONDEPARAM) VAP will apply several robust algorithms used in Wang et al. (2020) for the calculation of useful radiosonde convective cloud parameters, including the convective available potential energy (CAPE), convective inhibition (CIN), and other convective parameters, for several different assumptions regarding the initial parcel characteristics (i.e., surface-based, most unstable, mixed layer). These ARM VAP codes are developed in open, flexible Python formats, with the intention that these parameters/calculations will be incorporated into traditional ARM quick-look radiosonde plotting, yet associated with user-available codes for ease in user reproduction and assumption modification.

54 ENVIRONMENTAL SCIENCES↗

FARM User Guidance and Instructions

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, the general workflow and the software requirements of FARM module are summarized, and the detailed instructions for installing FARM software, running built-in example cases, deriving Linear Parameter-Varying (LPV) state-space models, and using FARM for user-defined power dispatch problems are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

G2PDeep-v2: A Web-Based Deep-Learning Framework for Phenotype Prediction and Biomarker Discovery for All Organisms Using Multi-Omics Data

Multi-omics data offers rich insights into complex traits across organisms, yet integrating and analyzing these datasets for phenotype prediction and marker discovery remains challenging. Researchers need accessible tools that combine deep learning, hyperparameter optimization, visualization, and downstream analysis in a unified web platform. To address this, we developed G2PDeep-v2, a web-based platform powered by deep learning for phenotype prediction and marker discovery from multi-omics data across a wide range of organisms, including humans and plants. The server provides multiple services for researchers to create deep-learning models through an interactive interface and train these models using an automated hyperparameter tuning algorithm on high-performance computing resources. Users can visualize the results of phenotype and markers predictions and perform Gene Set Enrichment Analysis for the significant markers to provide insights into the molecular mechanisms underlying complex diseases, conditions and other biological phenotypes being studied.

59 BASIC BIOLOGICAL SCIENCES↗

A Novel Sliding Mode Network Perimeter Controller

Congestion in urban areas is a chronic problem that faces many US and worldwide cities. It results in inefficient use of the infrastructure as well as increased fuel consumption and vehicle emissions. Congestion is intertwined with delay. Road users waste precious hours on the road, which reduces productivity. Throughout this decade researchers were and are developing tools and systems that alleviate this problem. Network perimeter control is one of these tools that has been studied extensively. It attempts to control the flow of vehicles entering a protected area so as not to reach the congested regime that is pre-determined using the Network Fundamental Diagram (NFD). In this paper, we present a novel and simple approach derived from sliding mode control theory that achieves the desired objective. Its main advantages over other control strategies include but are not limited to (1) ease of implementation, (2) minimal and straightforward model tuning, and (3) high performance. This controller was implemented and tested on a congested grid network. The results show that, the new logic performs as expected, producing network-wide delay savings that are consistent with other control approaches described in the literature. Furthermore, unlike other controllers, we demonstrate that the controller is robust to its hyper-parameter values, making the algorithm easy to implement and calibrate to local conditions. http://pubsindex.trb.org/

Sliding mode control, network perimeter control, n↗

Full 3D visualization tool-kit for Monte Carlo and deterministic transport codes

We propose a package of tools capable of translating the geometric inputs and outputs of many Monte Carlo and deterministic radiation transport codes into open source file formats. These tools are aimed at bridging the gap between trusted, widely-used radiation analysis codes and very powerful, more recent and commonly used visualization software, thus supporting the design process and helping with shielding optimization. Three main lines of development were followed: mesh-based analysis of Monte Carlo codes, mesh-based analysis of deterministic codes and Monte Carlo surface meshing. The developed kit is considered a powerful and cost-effective tool in the computer-aided design for radiation transport code users of the nuclear world, and in particular in the fields of core design and radiation analysis. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies: Preprint

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic generation and simulation of urban building energy models based on city datasets for city-scale building retrofit analysis

Buildings in cities consume 30–70% of total primary energy, and improving building energy efficiency is one of the key strategies towards sustainable urbanization. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures (ECMs) for investment and the design of incentive and rebate programs. This paper presents the retrofit analysis feature of City Building Energy Saver (CityBES) to automatically generate and simulate UBEM using EnergyPlus based on cities’ building datasets and user-selected ECMs. CityBES is a new open web-based tool to support city-scale building energy efficiency strategic plans and programs. The technical details of using CityBES for UBEM generation and simulation are introduced, including the workflow, key assumptions, and major databases. Also presented is a case study that analyzes the potential retrofit energy use and energy cost savings of five individual ECMs and two measure packages for 940 office and retail buildings in six city districts in northeast San Francisco, United States. The results show that: (1) all five measures together can save 23–38% of site energy per building; (2) replacing lighting with light-emitting diode lamps and adding air economizers to existing heating, ventilation and air-conditioning (HVAC) systems are most cost-effective with an average payback of 2.0 and 4.3 years, respectively; and (3) it is not economical to upgrade HVAC systems or replace windows in San Francisco due to the city's mild climate and minimal cooling and heating loads. Furthermore, the CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or technologies for the generation and simulation of building energy models, which helps overcome major technical barriers for city managers and their consultants to adopt UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computer usage and national energy consumption: Results from a field-metering study

The electricity consumption of miscellaneous electronic loads (MELs) in the home has grown in recent years, and is expected to continue rising. Consumer electronics, in particular, are characterized by swift technological innovation, with varying impacts on energy use. Desktop and laptop computers make up a significant share of MELs electricity consumption, but their national energy use is difficult to estimate, given uncertainties around shifting user behavior. This report analyzes usage data from 64 computers (45 desktop, 11 laptop, and 8 unknown) collected in 2012 as part of a larger field monitoring effort of 880 households in the San Francisco Bay Area, and compares our results to recent values from the literature. We find that desktop computers are used for an average of 7.3 hours per day (median = 4.2 h/d), while laptops are used for a mean 4.8 hours per day (median = 2.1 h/d). The results for laptops are likely underestimated since they can be charged in other, unmetered outlets. Average unit annual energy consumption (AEC) for desktops is estimated to be 194 kWh/yr (median = 125 kWh/yr), and for laptops 75 kWh/yr (median = 31 kWh/yr). We estimate national annual energy consumption for desktop computers to be 20 TWh. National annual energy use for laptops is estimated to be 11 TWh, markedly higher than previous estimates, likely reflective of laptops drawing more power in On mode in addition to greater market penetration. This result for laptops, however, carries relatively higher uncertainty compared to desktops. Different study methodologies and definitions, changing usage patterns, and uncertainty about how consumers use computers must be considered when interpreting our results with respect to existing analyses. Finally, as energy consumption in On mode is predominant, we outline several energy savings opportunities: improved power management (defaulting to low-power modes after periods of inactivity as well as power scaling), matching the rated power of power supplies to computing needs, and improving the efficiency of individual components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Study of the Effects of Different Urban Wind Models on Dispersion Patterns Using Joint Urban 2003 Data

The Quick Urban & Industrial Complex (QUIC) Dispersion Modeling System has been developed to rapidly compute the transport and dispersion of toxic agent releases in the vicinity of buildings. It is composed of a wind solver, an 'urbanized' Lagrangian random-walk model, and a graphical user interface. QUIC has two different wind models: (a) The QUIC-URB wind solver, an empirically-based diagnostic wind model and (b) The QUIC-CFD (RANS) solver, based on the 3D Reynolds-Averaged Navier-Stokes (RANS) equations. In this paper, we discuss the effect of different wind models on dispersion patterns in dense built-up areas. The model-computed wind from the two urban wind models- QUIC-URB and QUIC-CFD are used to drive the dispersion model. The concentration fields are then compared to measurements from the Oklahoma City Joint Urban 2003 field experiment. QUIC produces high-resolution 3-D mean wind and concentration fields around buildings, in addition to deposition on the ground and building surfaces. It has options for different release types, including point, moving point, line, area, and volumetric sources, as well as dense gas, explosive buoyant rise, multi-particle size, bioslurry, and two-phase releases. Other features include indoor infiltration, a pressure solver, outer grid simulations, vegetative canopies, and population exposure calculations. It has been used for biological agent sensor siting in cities, vulnerability assessments for heavier-than-air chemical releases at industrial facilities, and clean-up assessments for radiological dispersal device (RDD) releases in cities (e.g., see Linger et al., 2005; Brown, 2006a, b). QUIC has also been used for dust transport studies (Bowker et al., 2007a) and for the impact of highway sound barriers on the transport and dispersion of vehicle emissions (Bowker et al., 2007b).

54 ENVIRONMENTAL SCIENCES↗

Measurement Error in Atomic-Scale Scanning Transmission Electron Microscopy—Energy-Dispersive X-Ray Spectroscopy (STEM-EDS) Mapping of a Model Oxide Interface

Abstract With the development of affordable aberration correctors, analytical scanning transmission electron microscopy (STEM) studies of complex interfaces can now be conducted at high spatial resolution at laboratories worldwide. Energy-dispersive X-ray spectroscopy (EDS) in particular has grown in popularity, as it enables elemental mapping over a wide range of ionization energies. However, the interpretation of atomically resolved data is greatly complicated by beam–sample interactions that are often overlooked by novice users. Here we describe the practical factors—namely, sample thickness and the choice of ionization edge—that affect the quantification of a model perovskite oxide interface. Our measurements of the same sample, in regions of different thickness, indicate that interface profiles can vary by as much as 2–5 unit cells, depending on the spectral feature. This finding is supported by multislice simulations, which reveal that on-axis maps of even perfectly abrupt interfaces exhibit significant delocalization. Quantification of thicker samples is further complicated by channeling to heavier sites across the interface, as well as an increased signal background. We show that extreme care must be taken to prepare samples to minimize channeling effects and argue that it may not be possible to extract atomically resolved information from many chemical maps.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molten Salt Reactor Experiment Simulation using Shift/Griffin

The Department of Energy (DOE)’s NEAMS focuses its efforts on the development of advanced modeling and simulation (M&S) tools for light-water reactors (LWRs) and non–LWRs (i.e., molten salt reactors, high-temperature gas reactors, microreactors, and fast reactors). In the previous fiscal year, the Multiphysics Applications Driver Technical Area funded molten salt reactor (MSR) M&S at Oak Ridge National Laboratory (ORNL) to generate multigroup macroscopic cross sections with Shift for a MSRE 2D lattice model in Griffin. In addition, Shift’s capability to calculate gamma dose rates from activated components in the primary exchangers in a molten salt breeder reactor was also demonstrated. In fiscal year 2023, ORNL generated multigroup macroscopic cross sections using Shift for a 3D MSRE core model. MSRE depletion calculations using Griffin were also demonstrated in this fiscal year. For the depletion calculation, one-group microscopic cross sections for the 3D MSRE core were generated using Shift, and the decay transmutation library from ORIGEN was converted to an ISOXML file, which is required as input in Griffin. Several Monte Carlo codes, such as OpenMC and Serpent, were also used to benchmark and supplement multigroup cross sections generated by Shift. Multigroup libraries were generated with 8 and 20 group structures, and the study found the 8-group structure to be more accurate when comparing Griffin results to continuous energy (CE) Monte Carlo results. The average flux from CE Shift calculations is up to ~6% higher than the CE Serpent calculations because of different values applied for the energy released per fission (κ values). The average flux in the fuel salt calculated by Griffin using cross sections generated with Shift agrees well with the reference CE Shift solution; the same is valid for the corresponding Serpent results. The maximum relative error is ~6% and ~2% compared to the CE Shift and Serpent reference solutions, respectively. Meanwhile, the average flux calculated by Griffin in the graphite moderator shows a higher difference in the thermal range when compared to both reference Monte Carlo solutions; this result suggests a need for improvement in cross section generation for the graphite moderator in the thermal range in both Monte Carlo codes. Griffin depletion calculations using cross sections from Shift and Serpent were performed and compared against ORIGEN calculations, and the nuclide densities calculated by Griffin were found to be generally in agreement with those of ORIGEN. Because a different approach was taken to calculate the energy released per fission ( κ values) in Shift and Serpent, a difference in nuclide densities from differences in the average flux was observed between Griffin using Serpent and Shift cross sections. Griffin calculations with Shift cross sections produced higher average flux in the salt than with Serpent cross sections, leading to higher consumption of 235 U and higher production of 135 Xe. For time-dependent depletion calculations, cross sections were generated with Serpent, and Griffin’s results using these cross sections were compared to CE Serpent depletion results, demonstrating good agreement. The average difference in keff between Serpent and Griffin as a function of burnup is about 155 pcm. Similarly, good agreement with small differences up to ~0.5% was also noticed in the nuclide density of 235 U and 135 Xe. More details regarding the methodologies invoked to generate the cross section to make code-to-code comparisons are discussed further in this report. User feedback on Griffin and Shift capabilities that will enhance these calculations is provided in this report for future consideration. The work performed this fiscal year can be extended further for multiphysics coupling of Griffin-Pronghorn/SAM with Mole to study precursor flow and salt chemistry.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ATR National Scientific User Facility 2013 Annual Report

This is the 2013 Annual Report for the Advanced Test Reactor National Scientific User Facility. This report includes information on university-run research projects along with a description of the program and the capabilities offered researchers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Trends in urinary arsenic among the U.S. population by drinking water source: Results from the National Health and Nutritional Examinations Survey 2003–2014

Highlights: • We examined trends in arsenic exposure US general population between 2003 and 2014. • Exposure among US general population decreased by over 35% over the 12-year period. • Decreased exposure shown among community water supply and non-tap water users. • Inconsistent change in arsenic exposure among well or rain cistern populations. In 2001, the United States revised the arsenic maximum contaminant level for public drinking water systems from 50 µg/L to 10 µg/L. This study aimed to examine temporal trends in urinary arsenic concentrations in the U.S. population from 2003 to 2014 by drinking water source among individuals aged 12 years and older who had no detectable arsenobetaine - a biomarker of arsenic exposure from seafood intake.

54 ENVIRONMENTAL SCIENCES↗