Design and Instrumentation of a Measurement and Calibration System for an Acoustic Telemetry System

The Juvenile Salmon Acoustic Telemetry System (JSATS) is an active sensing technology developed by Portland District, the U.S. Army Corps of Engineers for detecting and tracking small fish. It is used at hydroelectric projects and in the laboratory for evaluating behavior and survival of juvenile salmonids migrating through the Federal Columbia River Power System to the Pacific Ocean. It provides critical data for salmon protection and development of more “fish-friendly” hydroelectric facilities. The objective of this study was to design and build a measurement and calibration system for evaluating the JSATS component, because the JSATS requires comprehensive acceptance and performance testing in a controlled environment before it is deployed in the field. The system consists of a reference transducer, a water test tank lined with anechoic material, a motion control unit, a reference receiver, a signal conditioner and amplifier unit, a data acquisition board, MATLAB control and analysis interface, and a computer. The fully integrated system has been evaluated successfully at various simulated distances and using different encoded signals at frequencies within the bandwidth of the JSATS transmitter. It provides accurate acoustic mapping capability in a controlled environment and automates the process that allows real-time measurements and evaluation of the piezoelectric transducers, sensors, or the acoustic fields. The measurement and calibration system has been in use since 2009 for acceptance and performance testing of, and further improvements to, the JSATS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Deep Generative Deconvolutional Image Model

A deep generative model is developed for representation and analysis of images, based on a hierarchical convolutional dictionary-learning framework. Stochastic unpooling is employed to link consecutive layers in the model, yielding top-down image generation. A Bayesian support vector machine is linked to the top-layer features, yielding max-margin discrimination. Deep deconvolutional inference is employed when testing, to infer the latent features, and the top-layer features are connected with the max-margin classifier for discrimination tasks. The model is efficiently trained using a Monte Carlo expectation-maximization (MCEM) algorithm; the algorithm is implemented on graphical processor units (GPU) to enable large-scale learning, and fast testing. Excellent results are obtained on several benchmark datasets, including ImageNet, demonstrating that the proposed model achieves results that are highly competitive with similarly sized convolutional neural networks.

convolutional neural network↗

Fast pyrolysis oil from pinewood chips co-processing with vacuum gas oil in an FCC unit for second generation fuel production

Raw bio-oil produced from fast pyrolysis of pine woodchips was co-processed with standard Brazilian vacuum gasoil (VGO) and tested in a 200 kg•h -1 fluid catalytic cracking (FCC) demonstration-scale unit using a commercial FCC equilibrium catalyst. Two different bio-oil/VGO weight ratios were used: 5/95 and 10/90. Co-processing of raw bio-oil in FCC was shown to be technically feasible. Bio-oil could be directly co-processed with a regular gasoil FCC feed up to 10 wt%. The bio-oil and the conventional gasoil were cracked into valuable liquid products such as gasoline and diesel range products. Most of the oxygen present in the bio-oil was eliminated as water and carbon monoxide as these yields were always higher than that of carbon dioxide. Product quality analysis shows that trace oxygenates, primarily alkyl phenols, in FCC gasoline and diesel products are present with or without co-processing oxygenated intermediates. The oxygenate concentrations increase with co-processing, but have not resulted in increased concerns with quality of fuel properties. The presence of renewable carbon was confirmed in gasoline and diesel cuts through 14 C isotopic analysis, showing that renewable carbon is not only being converted into coke, CO, and CO 2 , but also into valuable refining liquid products. Thus, gasoline and diesel could be produced from lignocellulosic raw materials through a conventional refining scheme, which uses the catalytic cracking process. As a result, the bio-oil renewable carbon conversion into liquid products (carbon efficiency) was approximately 30%, well above the efficiency found in literature for FCC bio-oil upgrading.

09 BIOMASS FUELS↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fire Resistance Development for UL 790 Burning Brand Test (CRADA Final Report)

Class A burning brand (UL 790) tests are used to determine the roof covering's effectiveness against severe exposure to external fire. Unfortunately, these tests can be costly to repeatedly perform when iteratively developing new materials/designs. The NREL team will work with the R&D Lab to develop and deploy computational tools to facilitate rapid development of roofing materials for the UL 790 standard test.

14 SOLAR ENERGY↗

Characterization of Filtration Scale-Up Performance

The scale-up performance of sintered stainless steel crossflow filter elements planned for use at the Pretreatment Engineering Platform (PEP) and at the Waste Treatment and Immobilization Plant (WTP) were characterized in partial fulfillment (see Table S.1) of the requirements of Test Plan TP RPP WTP 509. This test report details the results of experimental activities related only to filter scale-up characterization. These tests were performed under the Simulant Testing Program supporting Phase 1 of the demonstration of the pretreatment leaching processes at PEP. Pacific Northwest National Laboratory (PNNL) conducted the tests discussed herein for Bechtel National, Inc. (BNI) to address the data needs of Test Specification 24590-WTP-TSP-RT-07-004. Scale-up characterization tests employ high-level waste (HLW) simulants developed under the Test Plan TP-RPP-WTP-469. The experimental activities outlined in TP-RPP-WTP-509 examined specific processes from two broad areas of simulant behavior: 1) leaching performance of the boehmite simulant as a function of suspending phase chemistry and 2) filtration performance of the blended simulant with respect to filter scale-up and fouling. With regard to leaching behavior, the effect of anions on the kinetics of boehmite leaching was examined. Two experiments were conducted: 1) one examined the effect of the aluminate anion on the rate of boehmite dissolution and 2) another determined the effect of secondary anions typical of Hanford tank wastes on the rate of boehmite dissolution. Both experiments provide insight into how compositional variations in the suspending phase impact the effectiveness of the leaching processes. In addition, the aluminate anion studies provide information on the consequences of gibbsite in waste. The latter derives from the expected fast dissolution of gibbsite relative to boehmite. This test report concerns only results of the filtration performance with respect to scale-up. Test results for boehmite dissolution kinetics and filter fouling are reported elsewhere (see Table S.1). The primary goal of scale-up testing was to examine how filter length influenced permeate flux rates. To accomplish this, the existing cells unit filter system, which employs a 2-ft-long, 0.5-in. (inner) diameter sintered stainless steel filter element, was redesigned to accommodate an 8-ft. sintered stainless steel filter element of the same diameter. Testing was then performed to evaluate the filtration performance of waste simulant slurries. Scale-up testing consisted of two separate series of filtration tests: 1) scale-up axial velocity (AV)/transmembrane pressure (TMP) matrix tests and 2) scale-up temperature tests. The AV/TMP matrix tests examined filtration performance of two different waste simulant slurries in the 8-ft. cells unit filter system. Waste simulant slurry formulations for the 8-ft. scale-up test was selected to match simulant slurries for which filtration performance had been characterized on the 2-ft CUF. For the scale-up temperature tests, the filtration performance at three test temperatures (i.e., 25°C, 40°C, and 60°C) was determined to evaluate if filter flux versus temperature correlations developed using the 2-ft filters were also valid for the 8-ft filters.

36 MATERIALS SCIENCE↗

WE-F-16A-01: Commissioning and Clinical Use of PC-ISO for Customized, 3D Printed, Gynecological Brachytherapy Applicators

Purpose: (1) Evaluate the safety and radiation attenuation properties of PCISO, a bio-compatible, sterilizable 3D printing material by Stratasys, (2) establish a method for commissioning customized multi- and single-use 3D printed applicators, (3) report on use of customized vaginal cylinders used to treat a series of serous endometrial cancer patient. Methods: A custom film dosimetry apparatus was designed to hold a Gafchromic radio film segment between two blocks of PC-ISO and 3D-printed using a Fortus 400mc (StrataSys). A dose plan was computed using 13 dwell positions at 2.5 mm spacing and normalized to 1500 cGy at 1 cm. Film exposure was compared to control tests in only air and only water. The average Hounsfield Unit (HU) was computed and used to verify water equivalency. For the clinical use cases, the physician specifies the dimensions and geometry of a custom applicator from which a CAD model is designed and printed. Results: The doses measured from the PC-ISO Gafchromic film test were within 1% of the dose measured in only water between 1cm and 6cm from the channel. Doses increased 7–4% measured in only air. HU range was 11–43. The applicators were sterilized using the Sterrad system multiple times without damage. As of submission 3 unique cylinders have been designed, printed, and used in the clinic. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported. Conclusions: Quality assurance (QA) evaluation of the PC-ISO 3D-printing material showed that PC-ISO is a suitable material for a gynecological brachytherapy vaginal cylinder in a clinical setting. With the material commissioning completed, if the physician determines that a better treatment would Result, a customized design is fabricated with limited additional QA necessary. Although this study was specific to PC-ISO, the same setup can be used to evaluate other 3D-printing materials.

60 APPLIED LIFE SCIENCES↗

Polyethylene-Reflected Arrays of HEU(93.2) Metal Units Separated by Vermiculite

This benchmark details the results of an experiment performed in the early 1970s as part of a series testing critical configurations in three dimensional arrays. For this experiment, cylinders of 93.2% enriched uranium metal were arranged in a 2x2x2 array inside of a polyethylene reflector. Layers of vermiculite of varying heights were surrounding each cylinder to achieve criticality variations. A total of four experimental configurations were tested by D.W. Magnuson, and detailed in his experimental report “Critical Three-Dimensional Arrays of Neutron Interacting Units: Part IV. Arrays of U(93.2) Metal Reflected by Concrete and Arrays Separated by Vermiculite and Reflected by Polyethylene.” The benchmark HEU-MET-FAST054 is closely related; the results of both experiments are discussed in the same report (Ref. 1) Closely related work has been recorded in HEU-MET-FAST-053, which is a benchmark evaluation of a different series of three dimensional array experiments with four different moderator materials. HEU-MET-FAST-023 and HEU-MET-FAST-026 are also related because they utilize the same metal cylinders as these experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single Stage Contactor Testing Of The Next Generation Solvent Blend

The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-monotonic effects of market concentration on prices for residential solar photovoltaics in the United States

We report that emerging renewable energy markets may become more concentrated over time as the most efficient firms accumulate market share. The effects of this market concentration on prices are tested using a rich dataset of residential solar photovoltaic (PV) systems in the United States. A novel hypothesis is explored that the effects of market concentration may be non-monotonic. Prices may decline in market concentration due to efficiency gains associated with returns to scale but increase in concentration in already concentrated markets due to increasing market power. Finally, the results of an econometric model provide evidence to support the non-monotonic hypothesis. However, the data suggest that the relationship between prices and firm scale is nuanced, and that both large- and small-scale PV installers may wield efficiency advantages.

14 SOLAR ENERGY↗

Measuring the activity of BioBrick promoters using an in vivo reference standard

The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101) to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU) in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement conditions and instruments. Furthermore, these improvements are sufficient to begin to support the measurement of promoter activities across many laboratories. Additional in vivo reference standards for other types of biological functions would seem likely to have similar utility, and could thus improve research on the design, production, and reuse of standard biological parts.

59 BASIC BIOLOGICAL SCIENCES↗

ORNL Analysis of Leach-Burn-Leach Round-Robin Test Samples

An international round-robin test to examine the consistency in leach-burn-leach (LBL) analysis of tristructural-isotropic- (TRISO-) coated particle fuel was conducted by three research organizations from the Generation IV International Forum member countries of the People’s Republic of China, the Republic of Korea, and the United States of America. Two sets of round-robin test samples were exchanged for analysis. One set of samples consisted of a series of nonuranium-bearing, TRISO-coated zirconium dioxide particles seeded with up to four depleted uranium-bearing, TRISO-coated uranium dioxide (UO 2 ) particles, which had intentionally damaged coating layers to simulate either particles with either exposed-kernel defects (i.e., particles with a cracked TRISO coating that should be detected during preburn leaching) or particles with silicon carbide (SiC) defects (i.e., particles with an intact pyrocarbon coating and a hole in the SiC layer that should be detected during postburn leaching). These simulated samples also contained added powder with known quantities of impurities from a coal standard. The other sample set consisted of representative sublots of UO 2 -TRISO particles fabricated in a production-scale coater, except they all contained depleted uranium instead of enriched uranium. In this report, the methodology used at Oak Ridge National Laboratory to conduct LBL analysis of the round-robin samples is presented, and the general results are summarized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitor Unit Checking in Heterogeneous Stereotactic Body Radiotherapy Treatment Planning

Treatment of lung cancer using very-high-dose fractionation in small fields requires well-tested dose modeling, a method for density-averaging compound targets constructed from different parts of the breathing cycle, and monitor unit verification of the heterogeneity-corrected treatment plans. The quality and safety of each procedure are dependent on these factors. We have evaluated the dosimetry of our first 26 stereotactic body radiotherapy (SBRT) patients, including 260 treatment fields, planned with the Pinnacle treatment planning system. All targets were combined from full expiration and inspiration computed tomography scans and planned on the normal respiration scan with 6-MV photons. Combined GTVs (cGTVs) have been density-averaged in different ways for comparison of the effect on total monitor units. In addition, we have compared planned monitor units against hand calculations using 2 classic 1D correction methods: (1) effective attenuation and (2) ratio of Tissue-Maximum Ratios (TMRs) to determine the range of efficacy of simple verification methods over difficult-to-perform measurements. Different methods of density averaging for combined targets have been found to have minimal impact on total dose as evidenced by the range of total monitor units generated for each method. Nondensity-corrected treatment plans for the same fields were found to require about 8% more monitor units on average. Hand calculations, using the effective attenuation method were found to agree with Pinnacle calculations for nonproblematic fields to within {+-}10% for >95% of the fields tested. The ratio of TMRs method was found to be unacceptable. Reasonable choices for density-averaging of cGTVs using full inspiration/expiration scans should not strongly affect the planning dose. Verification of planned monitor units, as a check for problematic fields, can be done for 6-MV fields with simple 1D effective attenuation-corrected hand calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of nucleic acid amplification testing for rapid detection of Mycobacterium tuberculosis complex among U.S. tuberculosis patients from 2011–2017

Background: Nucleic acid amplification (NAA) tests rapidly detect Mycobacterium tuberculosis complex directly from clinical specimens, providing valuable results for those evaluated for tuberculosis. Methods: We analyzed characteristics of cases with NAA testing performed, compared cases with positive and negative NAA test results, and calculated turnaround time and time to treatment for all verified cases reported to the National Tuberculosis Surveillance System in the United States during 2011–2017. Results: Among 67082 verified tuberculosis cases with NAA testing information, 30820 (45.9%) were reported as not having an NAA test performed; the proportion without NAA testing declined annually, from 60.5% in 2011 to 33.6% in 2017. Of 67082 verified cases, 27912 (41.6%) had positive, 8215 (12.2%) had negative, and 135 (0.2%) had indeterminate NAA test results. Among the 33937 cases with an acid-fast bacilli (AFB) smear-positive result, 24093 (70.9%) had an NAA test performed; 11490 of the 30244 (38.0%) with an AFB smear-negative result had an NAA test performed. Although sputum was the most common specimen type tested, 79.8% (7023/8804) of nonsputum specimen types had a positive NAA test result. Overall, 63.7% of cases with laboratory testing had NAA test results reported <6 days following specimen collection; for 13891 cases not yet on treatment, median time to treatment after the laboratory report date was 2 days. Conclusions: Our analyses demonstrate increased NAA test utilization between 2011 and 2017. However, a large proportion of cases did not have an NAA test performed, reflecting challenges in broader uptake, suggesting an opportunity to expand use of this diagnostic methodology.

59 BASIC BIOLOGICAL SCIENCES↗

Use of the WECC WAMS in Wide Area Probing Tests for Validation of System Performance & Modeling

During 2005 and 2006 the Western Electricity Coordinating Council (WECC) performed three major tests of western system dynamics. These tests used a Wide Area Measurement System (WAMS) based primarily on Phasor Measurement Units (PMUs) to determine response to events including the insertion of the 1400-MW Chief Joseph braking resistor, probing signals, and ambient events. Test security was reinforced through real-time analysis of wide area effects, and high-quality data provided dynamic profiles for interarea modes across the entire western interconnection. The tests established that low-level optimized pseudo-random ±20-MW probing with the Pacific DC Intertie (PDCI) roughly doubles the apparent noise that is natural to the power system, providing sharp dynamic information with negligible interference to system operations. Such probing is an effective alternative to use of the 1400-MW Chief Joseph dynamic brake, and it is under consideration as a standard means for assessing dynamic security.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Technical Report for Award DE-FG02-05ER41389 A New Electrostatically-Focused, UV HPD for Liquid Xenon: A Direct Comparison with APD, PMT, SiPM in an Integrated Database

Within the scope of the project, a LXe detector and associated gas handling and purification system were set up to study the response of various photodetectors to the VUV Xe light. In particular we tested an Advanced Photonix Large Area Avalanche Photodiode (APD), Silicon Photomultipliers (SiPMs) from two different sources and an Hamamtsu Photonics APD. As part of the XENON Dark Matter project, sponsored by the National Science Foundation, we have accumulated independent knowledge of the response of compact metal channel photomultipliers. At this stage, we conclude that the last are far superior in terms of reliability and performance in a LXe detector environment. More studies are needed with APDs and SiPMs in LXe, taking advantage of the improved performance of these sensors with time. We could not test a hybrid PMT (HPD) since the only available unit on loan from one manufacturer lacked the mechanical stability and was packaged in a form not compatible with LXe purity requirements. Meanwhile, within the XENON collaboration, we are developing with Hamamatsu a hybrid PMT which is named QUPID (Quartz Photon Intensifying Detector) which promises to solve the problems of radioactivity and purity encountered with previous HPDs. We attach to this report two papers which summarize in detail the experimental st-ups, procedures and results obtained with different APDs and SiPMs operated in LXe. We continue our investigations of APDs in view of their potential appication in large arrays for LXe detectors. We intend to publish the results once we complete tests of newly acquired Hamamatsu APDs.

02 PETROLEUM↗

Preservation of FFTF Data Related to Passive Safety Testing

One of the goals of the Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMR). A key area deserving special attention for preservation is the data relating to passive safety testing that was conducted in FFTF and EBR-II during the 1980’s. Accidents at Unit 4 of the Chernobyl Station and Unit 2 at Three Mile Island changed the safety paradigm of the nuclear power industry. New emphasis was placed on assured safety based on intrinsic plant characteristics that protect not only the public, but the significant investment in the plant as well. Plants designated to perform in this manner are considered to be passively safe since no active sensor/alarm system or human intervention is required to bring the reactor to a safe shutdown condition. The liquid metal reactor (LMR) has several key characteristics needed for a passively safe reactor: reactor coolant with superior heat transfer capability and very high boiling point, low (atmospheric) system pressures, and reliable negative reactivity feedback. The credibility of the design for a passively safe LMR rests on two issues: the validity of analytic methods used to predict passive safety performance and the availability of relevant test data to calibrate design tools. Safety analysis methods used to analyze LMRs under the old safety paradigm were focused on calculating the source term for the Core Disruptive Accident. Passive safety design requires refined analysis methods for transient events because treatment of the detailed reactivity feedbacks is important in predicting the response of the reactor. Similarly, analytic tools should be calibrated against actual test experience in existing LMR facilities. The principal objectives of the combined FFTF natural circulation and Passive Safety Testing program were: 1) to verify natural circulation as a reliable means to safely remove decay heat, 2) to extend passive safety experience to a large-size LMR and obtain data for validating design analysis computer codes, and 3) to develop and test passive safety enhancements that might be used for future LMRs. These tests were designed to provide data sufficient to allow separation of fuel temperature effects from structural temperature effects. The data developed through this testing program were used to verify the predictive capability of passive safety analysis methods as well as provide a data base for calibrating design tools such as the SASSYS/SAS4A codes. These tests were instrumental in improving understanding of reactivity feedback mechanisms in LMRs and demonstrating passive safety margins available in an LMR. Knowledge preservation at the FFTF is focused on the areas of design, construction, startup, and operation of the reactor. This information may be of potential use for international exchanges with other LMR programs around the world. This information provides the basis for creating benchmarks for validating and testing large scale computer programs. All information preserved to date is now being stored and categorized consistent with the IAEA international standardized taxonomy. The test results information exists in several different formats depending upon the final stage of the test evaluation. Over 100 documents relevant to passive safety testing have been identified and are being recovered, scanned, and catalogued. Attempts to recover plant data tapes are also in progress. Documents related to passive safety testing are now being categorized consistent with internationally agreed upon IAEA standards. Documents are being converted to electronic format compatible with a general search engine being developed by INL. The data from the FFTF passive safety tests provides experimental verification of structural reactivity effects that should be very useful to innovative designers seeking to optimize passive safety in the design of new LMRs.