Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient behavior”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Endochronic theory of transient creep and creep recovery

Short time creep and creep recovery were investigated by means of the endochronic theory of viscoplasticity. It is shown that the constitutive equations for constant-strain-rate stress-strain behavior, creep, creep recovery, and stress relaxation can all ber derived from the general constitutive equation by imposing appropriate constraints. In this unified approach, the effect of strain-hardening is naturally accounted for when describing creep and creep recovery. The theory predicts with reasonable accuracy the creep and creep recovery behaviors for Aluminum 1100-0 at 150 C. It was found that the strain-rate history at prestraining stage affects the subsequent creep. A critical stress was also established for creep recovery. The theory predicts a forward creep for creep recovery stress greater than the critical stress. For creep recovery stress less than the critical stress, the theory then predicts a normal strain recovery.

Wu, H. C.↗

Comparison of subchannel and averaged channel thermal-hydraulic descriptions on coupled pin-by-pin neutronic calculations

Best-estimate transient analysis of Light Water Reactors (LWRs) requires high accuracy code systems solving neutronics (NK), thermal-hydraulics (TH) and thermal-mechanics to model the core behavior. For long time, nodal diffusion methods for solution of the transport equation using assembly size computational meshes have been applied neglecting the details within the fuel assembly, or using 'pin power reconstruction' techniques to predict those details. Moreover, the multiphysics analysis has been commonly performed coupling those neutronic diffusion methods to thermal-hydraulic system codes using a nodalization of several fuel assemblies per computational node without taking into account the effects that this type of averaging can have on the results obtained. This paper presents the work accomplished with the coupled system COBAYA4/CTF for a preliminary analysis of the effect of the different accuracy levels in the NK and TH domain. COBAYA4 is a neutronic code able to solve the diffusion equation at two resolution levels, nodal and pin by pin (PbP). CTF is a thermo-hydraulic code able to solve the coolant conservation equations also at two levels, channel (fuel assembly averaged solution) and sub-channel (real cooling channel) level. The coupled system COBAYA4/CTF is used through SALOME platform, i.e. SALOME is the software able to map conveniently the NK and TH meshes. This coupling allows combining different resolution levels for NK and TH problems. Therefore, the study of the effect of using different resolutions for the NK and TH nodalizations has been performed applying the system to a fuel assembly with selected boundary conditions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Elastic Model Transitions: A Hybrid Approach Utilizing Quadratic Inequality Constrained Least Squares (LSQI) and Direct Shape Mapping (DSM)

A method for transitioning linear time invariant (LTI) models in time varying simulation is proposed that utilizes a hybrid approach for determining physical displacements by augmenting the original quadratically constrained least squares (LSQI) algorithm with Direct Shape Mapping (DSM) and modifying the energy constraints. The approach presented is applicable to simulation of the elastic behavior of launch vehicles and other structures that utilize discrete LTI finite element model (FEM) derived mode sets (eigenvalues and eigenvectors) that are propagated throughout time. The time invariant nature of the elastic data presents a problem of how to properly transition elastic states from the prior to the new model while preserving motion across the transition and ensuring there is no truncation or excitation of the system. A previous approach utilizes a LSQI algorithm with an energy constraint to effect smooth transitions between eigenvector sets with no requirement that the models be of similar dimension or have any correlation. This approach assumes energy is conserved across the transition, which results in significant non-physical transients due to changing quasi-steady state energy between mode sets, a phenomenon seen when utilizing a truncated mode set. The computational burden of simulating a full mode set is significant so a subset of modes is often selected to reduce run time. As a result of this truncation, energy between mode sets may not be constant and solutions across transitions could produce non-physical transients. In an effort to abate these transients an improved methodology was developed based on the aforementioned approach, but this new approach can handle significant changes in energy across mode set transitions. It is proposed that physical velocities due to elastic behavior be solved for using the LSQI algorithm, but solve for displacements using a two-step process that independently addresses the quasi-steady-state and non-steady-state contributions to the elastic displacement. For structures subject to large external forces, such as thrust or atmospheric drag, it is imperative to capture these forces when solving for elastic displacement. To simplify the mathematical formulation, assumptions are made regarding mass matrix normalization, constant external forcing, and constant viscous damping. These simplifications allow for direct solutions to the quasi-steady-state displacements through a process titled Direct Shape Mapping. DSM solves for the displacements using the eigenvalues of the elastic modes and the external forcing and returns a set of elastic displacements dictated by the eigenvectors of the post-transition mode set. For the non-steady-state contributions to displacement we formulate a LSQI problem that is constrained by energy of the non-steady state terms. The contributions from the quasi-steady-state and non-steady state solutions are then combined to obtain the physical displacements associated with the new set of eigenvectors. Results for the LSQI-DSM approach show significant reduction/complete removal of transients across mode set transitions while maintaining elastic motion from the prior state. For time propagation applications employing discrete elastic models that need to be transitioned in time and where running with full a full mode set is not feasible, the method developed offers a practical solution to simulating vehicle elasticity.

Hannan, Mike R.↗

A parameter free prediction of simulated crystal nucleation times in the Lennard-Jones system: from steady state nucleation to the transient-time regime

Large scale simulations of crystal nucleation from the liquid are performed using the Lennard-Jones potential, to determine the time required for nucleation. By considering both transient and finite-size effects, we successfully predict the nucleation time within order of magnitude without any parameter fitting. All necessary parameters are derived from separate, equilibrium simulations. At smaller undercoolings, large system sizes are required, not only to accommodate large critical nuclei, but also to control statistical effects that are controlled by the density of critical nuclei. Two distinct nucleation regions are observed in the simulations, which are dominated by transient time and steady state nucleation time, respectively. At deep undercoolings, we still show consistency between predicted transient times and simulated nucleation times, which suggests that the short nucleation times in simulations are due to a small barrier to nucleation, rather than spinodal transformation that have been previously predicted. We compare with similar, previous results on a model of Al, which does not show such rapid nucleation at low temperatures, and suggest that the differences are due to the behavior of the reduced barrier G*/kBT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation Re-solution Calculation in Uranium-Silicide Fuels

The release of fission gas from nuclear fuels is of primary concern for safe operation of nuclear power plants. Although the production of fission gas atoms can be easily calculated from the fission rate in the fuel and the average yield of fission gas, the actual diffusion, behavior, and ultimate escape of fission gas from nuclear fuel depends on many other variables. As fission gas diffuses through the fuel grain, it tends to collect into intra-granular bubbles, as portrayed in Figure 1.1. These bubbles continue to grow due to absorption of single gas atoms. Simultaneously, passing fission fragments can cause collisions in the bubble that result in gas atoms being knocked back into the grain. This so called “re-solution” event results in a transient equilibrium of single gas atoms within the grain. As single gas atoms progress through the grain, they will eventually collect along grain boundaries, creating inter-granular bubbles. As the inter-granular bubbles grow over time, they will interconnect with other grain-face bubbles until a pathway is created to the outside of the fuel surface, at which point the highly pressurized inter-granular bubbles will expel their contents into the fuel plenum. This last process is the primary cause of fission gas release. From the simple description above, it is clear there are several parameters that ultimately affect fission gas release, including the diffusivity of single gas atoms, the absorption and knockout rate of single gas atoms in intra-granular bubbles, and the growth and interlinkage of intergranular bubbles. Of these, the knockout, or re-solution rate has an particularly important role in determining the transient concentration of single gas atoms in the grain. The re-solution rate will be explored in the following sections with regards to uranium-silicide fuels in order to support future models of fission gas bubble behavior.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Concentration dependent properties and plastic deformation facilitate instability of the solid-electrolyte interphase in Li-ion batteries

Lithium-ion batteries (LIBs) often suffer from capacity fading and poor cyclic performance due to mechanical degradation of the solid-electrolyte interphase (SEI). Here we perform numerical simulations and theoretical analysis to elucidate the role of plasticity in wrinkling and ratcheting behaviors of an SEI/electrode system. A coupled diffusion and finite deformation framework is formulated and numerically implemented as a user-element subroutine (UEL) to describe transient lithium diffusion and accompanying elastic–viscoplastic deformation of the electrode. It is found that concentration dependent properties and plastic deformation facilitate wrinkling in such a system. A wrinkled morphology may further lead to ratcheting and related failure under cycling. A phase diagram of four types of cyclic behaviorsis identified in terms of the charging rate and time. Our analysis suggests several potential strategies to avoid wrinkling and ratcheting instabilities, such as charging/discharging the electrode at a sufficiently slow rate, and/or introducing a thick artificial SEI with a pre-tension.

25 ENERGY STORAGE↗

Thermophysical properties and conduction mechanisms in As x Se 1-x chalcogenide glasses ranging from x = 0.2 to 0.5

The arsenic (As) to selenium (Se) ratio in As x Se 1-x glasses ranging from x = 0.2 to 0.5 was varied in order to examine the effect of chemical and topological ordering on the glass' thermal transport behavior. The fundamental thermal properties of glass transition temperature (T g ), thermal conductivity (k), and heat capacity (c p ) were experimentally measured using differential scanning calorimetry, transient plane source method, and ultrasonic testing. Based on topological constraint theory, inflections in T g and k were found at the structural coordination number $\langle$r$\rangle$ of 2.4, whereas a slight increase in heat capacity (c p ) with increasing $\langle$r$\rangle$ was observed. A maximum in total thermal conductivity of 0.232 W/m·K was measured for the composition with x = 0.4, which corresponds to the stoichiometric As 2 Se 3 . Gas kinetic theory was used to derive an expression for the photon (k p ) portion of thermal conductivity, which was calculated by measurements of the glass' absorption coefficient (α) and refractive index (n). Models based on Debye theory were then used to derive expressions for specific heat (c v ) and the lattice (k l ) portion of thermal conductivity. The maximum value for k p was 0.173 W/m·K for the composition with x = 0.2, and a minimum value of 0.144 W/m·K was measured for the composition with x = 0.4. Photonic conduction was found to be the dominant carrier mechanisms in all compositions, comprising 60% to 95% of the measured total thermal conductivity.

36 MATERIALS SCIENCE↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Chaotic /strange/ and periodic behavior in instability saturation by the oscillating two-stream instability

The nonlinear Schroedinger equation with linear growth and damping is truncated to three waves. The resulting system of nonlinear ordinary differential equations describes the excitation of linearly damped waves by the oscillating two-stream instability driven by a linearly unstable pump wave. This system represents a simple model for the nonlinear saturation of a linearly unstable wave. The model is examined analytically and numerically as a function of the dimensionless parameters of the system. It is found that the model can exhibit a wealth of characteristic dynamical behavior including stationary equilibria, Hopf bifurcations to periodic orbits, period doubling bifurcations, chaotic solutions characteristic of a strange attractor, tangent bifurcations from chaotic to periodic solutions, transient chaos, and hysteresis. Many of these features are shown to be explainable on the basis of one-dimensional maps. In the case of chaotic solutions, evidence for the presence of a strange attractor is provided by demonstrating Cantor set-like structure (i.e., scale invariance) in the surface of section.

Russell, D. A.↗

Strength distributions of SiC ceramics after oxidation and oxidation under load

The room-temperature strength distributions of a sintered and a hot-pressed SiC were examined as-machined, after oxidation at 1370 C, and after oxidation under load at 1370 C. The strengths were observed to be dependent on both the duration of oxidation and the magnitude of the applied load. Processes resulting in both strengthening and weakening behavior were observed to occur, at times simultaneously within the same strength distribution. This dynamic situation indicates that the strength-controlling flaw populations are highly transient in nature.

Easler, T. E.↗

Spatial profile of thermoelectric effects during Peltier pulsing in Bi and Bi/MnBi eutectic

The spatial profile of the thermal transients that occur during and following the current pulsing associated with Peltier Interface Demarcation during directional solidification is studied. Results for pure Bi are presented in detail and compared with corresponding results for the Bi/MnBi eutectic. Significant thermal transients occur throughout the sample that can be accounted for by the Peltier effect, the Thomson effect, and Joule heating. These effects are separated and their behavior is studied as a function of time, current density, and position with respect to the solid/liquid interface.

Silberstein, R. P.↗

Accretion disks in low-mass X-ray binaries

In this paper we review recent developments in our knowledge of accretion disks in low-mass X-ray binaries (LMXBs). We discuss some common behavior between the disks in cataclysmic variables and LMXBs, especially among those systems with high mass ratios. We consider ellipsoidal variability of soft X-ray transients (SXTs: transient LMXBs) in quiescence, and discuss the evidence for transient disk contamination of the light curves of these objects. We then show how optical photometry of SXTs in both outburst and quiescence can place useful constraints on the mass of the compact object in these binaries. Finally we present new results on the accretion disk structures of AC 211 in M15 and X 1916-05. We show that considerable evidence now exists for sizable disk structure displaced about 180 deg from the secondary: the origin of this structure is as yet unknown.

Callanan, Paul J.↗

High Frequency Low Amplitude Temperature Oscillations in Loop Heat Pipe Operation

The operating temperature of a loop heat pipe (LHP) with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a finction of the evaporator power, condenser sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. This paper presents a study on the oscillation of the loop operating temperature with amplitudes on the order of one degree Kelvin and frequencies on the order of 10(exp -1) to 10(exp -2) Hertz. The source of the high frequency temperature oscillation is the fast movement of the vapor front in the condenser section, which usually occurs when the vapor front is near the condenser inlet or the condenser outlet. At these locations, the vapor front is unable to find a stable position for the given operating conditions, and will move back and forth. The movement of the vapor front causes the movement of the liquid in the condenser and the liquid line, leading to oscillations of the CC and the loop temperatures. Factors that affect the vapor front movement include evaporator power, condenser sink temperature, body forces and whether or the CC temperature is actively controlled. As long as there are no large thermal masses attached to the evaporator, the loop can self adjust rather quickly and the vapor front will move rapidly around the condenser inlet or outlet, leading to high frequency temperature oscillations. The amplitude of temperature oscillation is usually the largest in the liquid line, up to 20 degrees Kelvin in many cases, but diminishes to less than one degree Kelvin in the CC. Furthermore, the high frequency temperature oscillation can occur at any CC temperature when the right combination of the evaporator power and condenser sink temperature prevails.

Ku, Jentung↗

Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation

This paper presents a theory that explains low frequency, high amplitude temperature oscillations in loop heat pipe (LHP) operation. Oscillations of the CC temperature with amplitudes on the order of tens of degrees Kelvin and periods on the order of hours have been observed in some LHPs during ambient testing. There are presently no satisfactory explanations for such a phenomenon in the literature. It is well-known that the operating temperature of an LHP with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a function of the evaporator heat load, sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. The proposed new theory describes why low frequency, high amplitude oscillations may occur when the LHP has a low evaporator power, a low heat sink temperature (below ambient temperature), and a large thermal mass attached to the evaporator. When this condition prevails, there are some complex interactions between the CC, condenser, thermal mass and ambient. The temperature oscillation is a result of the large movement of the vapor front inside the condenser, which is caused by a change in the net evaporator power modulated by the large thermal mass through its interaction with the sink and CC. The theory agrees very well with previously published test data. Effects of various parameters on the amplitude and frequency of the temperature oscillation are also discussed.

Ku, Jentung↗

Liquid Fuels: Pyrolytic Degradation and Fire Spread Behavior as Influenced by Buoyancy

This project was conducted by the Combustion and Emission Control Lab in the Engineering Department at Clark Atlanta University under NASA Grant No. NCC3-707. The work aimed at providing data to supplement the ongoing NASA research activities on flame spread across liquid pools by providing flow visualization and velocity measurements especially in the gas phase and gas-liquid interface. During this investigation, the detailed physics of flame spread across liquid pools was revealed using particle image velocimetry (PIV), 3-dimensional Laser Doppler velocimetry (LDV) and high-speed video imaging system (HSVS). Flow fields (front and side views) of both the liquid and gas phases were visually investigated for the three subflash regimes of flame spread behavior. Some interesting findings obtained from the front and side views on flame spread across butanol pools are presented. PIV results showed the size of the transient vortex in the liquid phase near the flame front varied with the initial pool temperature. The transient vortex ahead of the flame front in the gas phase was, for the first time, clearly observed located just within 0-3 mm above the liquid surface and its size was dependent on the initial pool temperature. We calculated the flow velocity at 1 mm below the liquid surface near the flame front and inferred the generation mechanism of the vortex in the gas phase. Finally, after comparison of the flow velocity of the liquid surface and the flame spread rate, a reasonable explanation to the formation mechanism of the pulsating characteristic was proposed. This explanation is compatible with the previous numerical calculations and deductions.

Ross, Howard D.↗

Application of a Developmental Composite Material Model to Predict the Crush Response of Two Energy Absorbers

In 2012, a consortium was formed with the goal of creating a new composite material model capable of predicting the wide range of properties, accumulated damage behavior, and the many different types of failure in composites under impact loading. The material model was developed for execution in the commercially available nonlinear, explicit transient dynamic finite element code, LS-DYNA®. This material model incorporates three sub-models: deformation, damage, and failure. In addition, the model accounts for strain rate and temperature effects and relies heavily on the input of tabulated material response data. The model is designated *MAT_COMPOSITE_TABULATED_PLASTICITY_DAMAGE, or *MAT_213. Initially, *MAT_213 was developed for use with solid elements only; however, a thin shell element formulation for *MAT_213 has been adapted recently. The objective of this project was to find a suitable modeling example to investigate the capabilities and performance of *MAT_213. In 2012, two composite energy absorbers were designed and evaluated at NASA Langley Research Center through multi-level testing and simulation. The first was a conical-shaped energy absorber, designated the conusoid, which consisted of four layers of hybrid carbon-Kevlar® plain-weave fabric oriented at [+45°/-45°/-45°/+45°] with respect to the vertical direction. The second was a sinusoidal-shaped energy absorber, designated the sinusoid, which consisted of hybrid carbon-Kevlar® plain-weave fabric face sheets, two layers for each face sheet oriented at ±45° with respect to the vertical direction, and a closed-cell ELFOAM® P200 polyisocyanurate foam core. Finite element models were developed of the energy absorbers and simulations were performed using LS-DYNA®. In this paper, the development of a *MAT_213 model of a hybrid carbon-Kevlar® plain-weave fabric is presented. Next, comparisons with material characterization tests are presented. Then, test-analysis results are documented for each energy absorber as comparisons of time-history responses, as well as predicted and experimental structural deformations and progressive damage under impact loading using the *MAT_213 material model. Since a prior *MAT_58, or *MAT_LAMINATED_COMPOSITE_FABRIC material model was used in previous simulations of the energy absorbers, comparisons are made between *MAT_58 and *MAT_213 model predictions with test data. Finally, the paper includes a comprehensive list of “lessons learned,” in which a series of parametric studies are documented that were performed to investigate specific issues related to the material model. These “lessons learned” are included in hopes that they may help future *MAT_213 users.

crashworthiness, LS-DYNA transient dynamic simulat↗