Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Temperature distributions and gradients in laser-heated plasmas relevant to magnetized liner inertial fusion

We present two-dimensional temperature measurements of magnetized and unmagnetized plasma experiments performed at Z relevant to the preheat stage in magnetized liner inertial fusion. The deuterium gas fill was doped with a trace amount of argon for spectroscopy purposes, and time-integrated spatially resolved spectra and narrow-band images were collected in both experiments. The spectrum and image data were included in two separate multiobjective analysis methods to extract the electron temperature spatial distribution T e ( r , z ) . The results indicate that the magnetic field increases T e , the axial extent of the laser heating, and the magnitude of the radial temperature gradients. Comparisons with simulations reveal that the simulations overpredict the extent of the laser heating and underpredict the temperature. Temperature gradient scale lengths extracted from the measurements also permit an assessment of the importance of nonlocal heat transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved investigation of subnanosecond radiation from Al wire hybrid X pinches

K-shell x-ray spectra from Al wire hybrid X pinches have been studied using an x-ray streak camera with better than 0.1-ns time resolution together with a Focusing Spectrograph with Spatial Resolution (FSSR) spectrograph. High-intensity radiation with a continuumlike spectrum was observed in the subnanosecond initial phase of the x-ray pulse generated by the hybrid X pinch (HXP). Here, the absence of spectral lines in this phase and the extremely small x-ray source size indicates the importance of radiative processes in the final phase implosion dynamics. Plasma parameters in the following phases of the HXP were determined from analysis of the line intensities. Point-projection radiography together with a slit-step wedge camera and an FSSR spectrograph without time resolution were used to show the number of radiation sources, and to give information on the time-integrated photon energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of the Strong Phase in D{sup 0}{yields}K{sup +}{pi}{sup -} Using Quantum-Correlated Measurements

We exploit the quantum coherence between pair-produced D{sup 0} and D{sup 0} in {psi}(3770) decays to study charm mixing, which is characterized by the parameters x and y, and to make a first determination of the relative strong phase {delta} between D{sup 0}{yields}K{sup +}{pi}{sup -} and D{sup 0}{yields}K{sup +}{pi}{sup -}. Using 281 pb{sup -1} of e{sup +}e{sup -} collision data collected with the CLEO-c detector at E{sub cm}=3.77 GeV, as well as branching fraction input and time-integrated measurements of R{sub M}{identical_to}(x{sup 2}+y{sup 2})/2 and R{sub WS}{identical_to}{gamma}(D{sup 0}{yields}K{sup +}{pi}{sup -})/{gamma}(D{sup 0}{yields}K{sup +}{pi}{sup -}) from other experiments, we find cos{delta}=1.03{sub -0.17}{sup +0.31}{+-}0.06, where the uncertainties are statistical and systematic, respectively. By further including other mixing parameter measurements, we obtain an alternate measurement of cos{delta}=1.10{+-}0.35{+-}0.07, as well as xsin{delta}=(4.4{sub -1.8}{sup +2.7}{+-}2.9)x10{sup -3} and {delta}=(22{sub -12-11}{sup +11+9}) deg.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spontaneous Polarization Buildup in a Room-Temperature Polariton Laser

We observe the buildup of strong ({approx}50%) spontaneous vector polarization in emission from a GaN-based polariton laser excited by short optical pulses at room temperature. The Stokes vector of emitted light changes its orientation randomly from one excitation pulse to another, so that the time-integrated polarization remains zero. This behavior is completely different from any previous laser. We interpret this observation in terms of the spontaneous symmetry breaking in a Bose-Einstein condensate of exciton polaritons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10{sup -17} Level

We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5x10{sup -17} after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice related perturbations will not affect the clock accuracy down to the 10{sup -17} level, even for lattices as deep as 150 recoil energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comment on “In-depth Plasma-Wave Heating of Dense Plasma Irradiated by Short Laser Pulses”

Sherlock et al. have reported on the heating of solid density targets by collisional damping of wakefields that are driven by relativistic electron bunches generated in relativistic laser matter interaction. Analyzing collisional particle-in-cell simulations they calculate the fast electron current j f inside the plasma by adding contributions from electrons with energies greater than E cut = 50 keV; time-integrating the specific resistive energy deposition η j 2 f they arrive at a temperature profile and compare the result to the one 'measured' in their simulation, defined as the energy of particles with E < 30 keV; the discrepancy is due to collisional damping of wake fields (CDW). Here, we disagree with their metric of fast current, which leads to false conclusions about CDW heating being a volumetric, rather than surface effect.

42 ENGINEERING↗

Exact Fluctuations of Nonequilibrium Steady States from Approximate Auxiliary Dynamics

We describe a framework to reduce the computational effort to evaluate large deviation functions of time integrated observables within nonequilibrium steady states. We do this by incorporating an auxiliary dynamics into trajectory based Monte Carlo calculations, through a transformation of the system's propagator using an approximate guiding function. This procedure importance samples the trajectories that most contribute to the large deviation function, mitigating the exponential complexity of such calculations. Here, we illustrate the method by studying driven diffusion and interacting lattice models in one and two spatial dimensions. Finally, our work offers an avenue to calculate large deviation functions for high dimensional systems driven far from equilibrium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field-Dependent Ionic Conductivities from Generalized Fluctuation-Dissipation Relations

We derive a relationship for the electric field dependent ionic conductivity in terms of fluctuations of time integrated microscopic variables. We demonstrate this formalism with molecular dynamics simulations of solutions of differing ionic strength with implicit solvent conditions and molten salts. These calculations are aided by a novel nonequilibrium statistical reweighting scheme that allows for the conductivity to be computed as a continuous function of the applied field. In strong electrolytes, we find the fluctuations of the ionic current are Gaussian, and subsequently, the conductivity is constant with applied field. In weaker electrolytes and molten salts, we find the fluctuations of the ionic current are strongly non-Gaussian, and the conductivity increases with applied field. Furthermore, this nonlinear behavior, known phenomenologically for dilute electrolytes as the Onsager-Wien effect, is general and results from the suppression of ionic correlations at large applied fields, as we elucidate through both dynamic and static correlations within nonequilibrium steady states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonuniform Absorption and Scattered Light in Direct-Drive Implosions Driven by Polarization Smoothing

Laser-direct-drive symmetric implosions on OMEGA illuminate a target with 60 laser beams and are designed to produce spherical implosions. Each beam is smoothed using orthogonal polarizations obtained by passing through distributed polarization rotators (DPR’s). Observations of the scattered light from OMEGA implosions do not show the expected symmetry and have much larger variation than standard predictions. For the first time, we have quantified the scattered-light nonuniformity from individual beams and identified the DPR’s as the source of the enhanced nonuniformity. An instrument was invented that isolated and measured the variation in the intensity and polarization of the light scattered from each OMEGA beam. The asymmetric intensity and polarization measurements are explained when the on-target offsets between the two orthogonal polarizations produced by the DPR’s are modeled using a 3-D cross-beam energy transfer (CBET) code that tracks the polarizations of each beam. The time-integrated nonuniformity in laser absorption and scattered light due to CBET and the DPR polarization offsets during high-performance OMEGA implosions is predicted to be significant and dominated by low spherical harmonic mode numbers. Further, the nonuniformity is predicted to be greatly reduced by replacing the DPR’s with new optics that create smaller offsets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He β spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. Here these advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the Branching Fraction, Polarization, and C P Asymmetry for the Decay B 0 → ω ω

We present a comprehensive study of B 0 → ω ω decays using 772 × 10 6 B B ¯ pairs collected with the Belle detector at the KEKB e + e − collider. This process is a suppressed charmless decay into two vector mesons and can exhibit interesting polarization and C P violation. The decay is observed for the first time with a significance of 7.9 standard deviations. We measure a branching fraction B = ( 1.53 ± 0.29 ± 0.17 ) × 10 − 6 , a fraction of longitudinal polarization f L = 0.87 ± 0.13 ± 0.13 , and a time-integrated C P asymmetry A C P = − 0.44 ± 0.43 ± 0.11 , where the first uncertainties listed are statistical and the second are systematic. This is the first observation of B 0 → ω ω and the first measurements of f L and A C P for this decay. Published by the American Physical Society 2024

Physics↗

Integrated nonlinear optical imaging microscope for on-axis crystal detection and centering at a synchrotron beamline

Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ~10 3 –10 4 -fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering and analysis of phenylalanine hydroxylase from Chromobacterium violaceum cPAH, Trichinella spiralis deubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied.

bio-inspired↗

Optimization of a phase-space beam position and size monitor for low-emittance light sources

The recently developed vertical phase-space beam position and size monitor (ps-BPM) system has proven to be able to measure the electron-source position, angle, size and divergence simultaneously in the vertical plane at a single location of a beamline. The optimization of the ps-BPM system is performed by ray-tracing simulation to maximize the instrument sensitivity and resolution. The contribution of each element is studied, including the monochromator, the K -edge filter, the detector and the source-to-detector distance. An optimized system is proposed for diffraction-limited storage rings, such as the Advanced Photon Source Upgrade project. The simulation results show that the ps-BPM system can precisely monitor the source position and angle at high speed. Precise measurements of the source size and divergence will require adequate resolution with relatively longer integration time.

47 OTHER INSTRUMENTATION↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Voltage Loss Comparison in CdSe/CdTe Solar Cells and Polycrystalline CdSeTe Heterostructures

Cd(Se)Te solar cells have considerable headroom to increase voltage. Voltage losses occur due to incomplete absorption above bandgap E_g and band tail absorption below E_g; such losses are quantified using radiative voltage. The largest voltage losses are attributed to nonradiative recombination, which is quantified via carrier lifetime and radiative efficiency. We compare radiative voltage, radiative efficiency, and carrier lifetime for Cu-doped CdSe/CdTe solar cells and for undoped polycrystalline CdSeTe heterostructures passivated with Al_2O_3. Using external quantum efficiency spectrum and a CdSeTe absorption spectrum obtained from absolute photoluminescence (PL), we show that the radiative voltage is greater than 1.1 V. Time-resolved PL experiments and modeling show that a major part of voltage losses can be attributed to recombination in the absorber bulk. The front interface recombination makes a larger impact within the first few nanoseconds after pulsed excitation, and the comparison of time-gated and time-integrated PL can be used to assess relative contributions of front interface and bulk recombination rates.

14 SOLAR ENERGY↗

Quantifying and Reducing Uncertainty in Correlated Multi-Area Short-Term Load Forecasting

In this study, we represent and reduce the uncertainties in short-term electric load forecasting by integrating time series analysis tools including ARIMA modeling, sequential Gaussian simulation, and principal component analysis. The approaches are mainly focusing on maintaining the inter-dependency between multiple geographically related areas. These approaches are applied onto cross-correlated load time series as well as their forecast errors. Multiple short-term prediction realizations are then generated from the reduced uncertainty ranges, which are useful for power system risk analyses.

load forecast↗

The Hybrid X-Pinch as a Source of XUV Radiation

The first detailed study of hybrid X-pinch (HXP) radiation in the wavelength range 10–200 Å on the BIN pulser (270 kA, 100 ns rise time) is introduced here. X-pinch loads were made from Al, Mo, Ag, and W wires with 13–30 μm diameters. Time-integrated images were obtained using open pinholes with 100 μm aperture. Spatially resolved XUV spectra were recorded using a transmission grating spectrograph on UF-4 film and with Fuji TR image plates. Signals from calibrated photoconducting detectors enabled estimates of the absolute yield of radiation and demonstrated that Mo HXPs radiate about 100× more energy in UV radiation than in X-rays with energy above 1 keV.

Hot spot (HS)↗