Instrumented adhesion tests on plasma sprayed thermal barrier coatings

The failure mechanisms of plasma-sprayed two-layer coatings consisting of an NiCrAlY or NiCrAlZr bond coat with an yttria-stabilized zirconia overlay are presently examined by tensile adhesion tests. It has been found that adhesive failure within the bond coat exhibits greater failure strain than the cohesive failure of the ceramic overlay, supporting the view of the intermediate coatings being highly compliant. The absolute extension exhibited by failures occurring only through the ceramic coating is greater than that of adhesive failure, since the ceramic coating is much thicker than the bond coat.

Berndt, Christopher C.↗

Case Study of Using Flocad to Model a Ground Test Station Ln2 Heat Exchanger

This paper presents a case study of using FLOCAD to model the heat transfer and boiling flow behavior of a Liquid Nitrogen (LN2) ground station equipment heat exchanger. The unique aspect of this work is that is one of very few studies documenting the use of FLOCAD in the spacecraft thermal control community. The results of the simulations described herein were used to guide and plan the execution of thermal vacuum testing spacecraft hardware using a ground test heat exchanger such as the one modeled herein. The paper will review the theory of two-phase boiling flow and correlations used by SINDA/FLUINT as well as the terminology and nomenclature used within Thermal Desktop / FLOCAD regarding two-phase boiling flow heat transfer modeling and simulation. Results for using the ground station heat exchanger as a heat sink in a thermal vacuum test set up are shown in order to demonstrate the set-up and execution of a typical FLOCAD model. Results indicate that properly modeling of the two-phase behavior is critical in order to ascertain the time constant associated with the heat exchanger, as well as understanding the temperature distribution across the test equipment and prediction of required LN2 flowrates to be used during testing. The paper is meant to augment the FLOCAD user’s manual and serve as a tutorial for thermal engineers and analysts wishing to learn and apply FLOCAD to industrial problems.

Anderson, Kevin R.↗

Development of a Thermal Oxidizer for Distributed Microturbine Based Generation

This project concerns the replacement of the catalytic bed in a microturbine with a thermal oxidizer. The advantage of a thermal oxidizer over a traditional combustion chamber is that the length and temperature of the device allows the volatile species to oxidize relatively slowly and without a flame front. With no flame, the temperature increase throughout the unit is spread over a much larger volume so there is no hot spot for thermal NO{sub x} formation, and the gas Btu level does not have to be above the ignition concentration. Project specific objectives included assessment of the materials and performance requirements of the thermal oxidizer, design the thermal oxidizer system, fabrication of the thermal oxidizer, testing of the oxidizer's performance in concert with the microturbine and comparison of the performance of the oxidizer with catalytic beds and traditional combustion chambers. The thermal oxidizer was designed and fabricated with the assistance of High Country Fabrication of Casper, Wyoming. The design consists of a long set of tubes surrounded by a packed bed of loose ceramic material. The outer vessel containing the tubes and packing is a 3-foot diameter steel shell with multiple layers of thermal insulation. After the metal components were fabricated, the vessel was shipped to Denver where the insulation was poured. The unit was shipped to the cosponsor site for integration with the 100 kW microturbine device. Connection of the thermal oxidizer to the Elliot microturbine turned out to be problematic. The high flow rate of gas tended to push the hot zone out of the oxidizer as assembled. The research team identified several approaches to improve the oxidizer performance including a longer gas path, increased residence time, higher surface area packing material and improved combustion catalysts. The cosponsor is working with an engineering form with oxidizer experience to reconfigure the hardware before moving to a field trial on landfill gas.

36 MATERIALS SCIENCE↗

Poly(methyl methacrylate)/layered zinc sulfide nanocomposites: Preparation, characterization and the improvements in thermal stability, flame retardant and optical properties

Highlights: • Layered zinc sulfide (LZnS) was synthesized successfully via hydrothermal method. • We prepare PMMA/LZnS nanocomposites by in situ bulk polymerization of MMA. • PMMA/LZnS nanocomposites were investigated by TGA, DSC, MCC, UV–vis and PL test. • The thermal stability, flame retardant and optical properties of PMMA are improved. - Abstract: Layered zinc sulfide (LZnS) was synthesized successfully via hydrothermal method and poly(methyl methacrylate) (PMMA)/layered zinc sulfide nanocomposites were obtained by in situ bulk polymerization of methyl methacrylate (MMA). X-ray diffraction (XRD) and transmission electron microscopy (TEM) were used to characterize the as-synthesized layered zinc sulfide and PMMA/layered zinc sulfide nanocomposites. Microscale combustion calorimeter (MCC), differential scanning calorimeter (DSC) and thermogravimetric analysis (TGA) were used to test the thermal properties of the composites. Ultraviolet visible (UV–vis) transmittance spectra and photoluminence (PL) spectra were obtained to investigate the optical properties of the composites. From the results, the thermal degradation temperature is increased by 20–50 °C, the peak of heat release rate (pHRR) and total heat release (THR) are both decreased by above 30%, and the photoluminence intensity is enhanced with the increasing loading of layered zinc sulfide.

36 MATERIALS SCIENCE↗

Purging of a tank-mounted multilayer insulation system by gas diffusion

The investigation was conducted on a multilayer insulation (MLI) system mounted on a spherical liquid hydrogen propellant tank. The MLI consisted of two blankets of insulation each containing 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The gaseous nitrogen initially contained within the MLI system and vacuum chamber was purged with gaseous helium introduced both underneath the MLI and into the vacuum chamber. The MLI panels were assumed to be purged primarily by means of gas diffusion. Overall, test results indicated that nitrogen concentrations well below 1 percent could be achieved everywhere within the MLI system. Typical times to achieve 1 percent nitrogen concentration within the MLI panels ranged from 69 minutes at the top of the tank to 158 minutes at the bottom of the tank. Four space-hold thermal performance tests indicated no significant thermal degradation of the MLI system had occurred due to the purge tests conducted. The final measured heat input attributed to the MLI was 7.23 watts as compared to 7.18 watts for the initial baseline thermal performance test.

Sumner, I. E.↗

Integrated Data Collection Analysis (IDCA) Program - Final Review September 12, 2012 at DHS

The Integrated Data Collection Analysis (IDCA) program conducted a final program review at the Department of Homeland Security on September 12, 2012. The review was focused on the results of the program over the complete performance period. A summary presentation delineating the accomplished tasks started the meeting, followed by technical presentations on various issues that arose during the performance period. The presentations were completed with a statistical evaluation of the testing results from all the participants in the IDCA Proficiency Test study. The meeting closed with a discussion of potential sources of funding for continuing work to resolve some of these technical issues. This effort, funded by the Department of Homeland Security (DHS), put the issues of safe handling of these materials in perspective with standard military explosives. The study added Small-Scale Safety and Thermal (SSST) testing results for a broad suite of different HMEs to the literature, and suggested new guidelines and methods to develop safe handling practices for HMEs. Each participating testing laboratory used identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results were compared among the laboratories and then compared to historical data from various sources. The testing performers involved were Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Naval Surface Warfare Center, Indian Head Division (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory, Tyndall AFB (AFRL/RXQL). These tests were conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a two axis motion simulation system for thermal/vacuum satellite testing

A two-axis motion simulation system for thermal vacuum testing of large satellites in a space simulation chamber was developed. Satellites as large as 3000 kilograms with a 4-meter diameter and a 5-meter length can be tested. This motion simulator (MS) incorporates several unique features which result in a less complicated design with improved performance when compared to previous satellite motion simulators. The design of the simulator is discussed in detail.

Henderson, David↗

Insulation Test Cryostat with Lift Mechanism

A multi-purpose, cylindrical thermal insulation test apparatus is used for testing insulation materials and systems of materials using a liquid boil-off calorimeter system for absolute measurement of the effective thermal conductivity (k-value) and heat flux of a specimen material at a fixed environmental condition (cold-side temperature, warm-side temperature, vacuum pressure level, and residual gas composition). An inner vessel receives liquid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including upper and lower guard chambers and middle test vessel, is suspended from a lid of the vacuum canister. Each of the three chambers is filled and vented through a single feedthrough. All fluid and instrumentation feedthroughs are mounted and suspended from a top domed lid allowing easy removal of the cold mass. A lift mechanism allows manipulation of the cold mass assembly and insulation test article.

Fesmire, James E.↗

Insulation Test Cryostat with Lift Mechanism

A multi-purpose, cylindrical thermal insulation test apparatus is used for testing insulation materials and systems of materials using a liquid boil-off calorimeter system for absolute measurement of the effective thermal conductivity (k-value) and heat flux of a specimen material at a fixed environmental condition (cold-side temperature, warm-side temperature, vacuum pressure level, and residual gas composition). The apparatus includes an inner vessel for receiving a liquid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the upper and lower guard chambers and a middle test vessel, is suspended from a lid of the vacuum canister. Each of the three chambers is filled and vented through a single feedthrough. All fluid and instrumentation feedthroughs are mounted and suspended from a top domed lid to allow easy removal of the cold mass. A lift mechanism allows manipulation of the cold mass assembly and insulation test article.

Fesmire, James E.↗

Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs), which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This study presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

43 PARTICLE ACCELERATORS↗

Use of unbalanced laminates as a screening method for microcracking

State-of-the-art, high temperature polyimide matrix composites, reinforced with continuous graphite fibers are known to be susceptible to intraply cracking when thermally cycled over their useful service temperature range. It is believed that the transply cracking, in part, results from residual stresses caused by differences in coefficients of thermal expansion (CTE) between the polymer matrix and the reinforcement. Thermal cycling tests to investigate this phenomenon involve expensive time and energy consuming programs which are not economically feasible for use as a part of a materials screening process. As an alternative to thermal cycling studies, a study of unbalanced crossply graphite fiber reinforcement composites was conducted to assess the effect of the composite ply layup and surface condition on the residual stresses that remain after the processing of these materials. The residual stresses were assessed by measuring the radii of curvature of the types of laminates that were studied. The temperature at which stress-free conditions existed were determined and a dye penetrant method was used to observe surface damage resulting from excessive residual stress buildup. These results are compared with some published results of thermal cycling tests that were previously conducted on balanced polyimide composites.

Papadopoulos, Demetrios S.↗

Use of unbalanced laminates as a screening method for microcracking

State-of-the-art, high temperature polyimide matrix composites, reinforced with continuous graphite fibers are known to be susceptible to intraply cracking when thermally cycled over their useful service temperature range. It is believed that the transply cracking, in part, results from residual stresses caused by differences in coefficients of thermal expansion (CTE) between the polymer matrix and the reinforcement. Thermal cycling tests to investigate this phenomenon involve expensive time and energy consuming programs which are not economically feasible for use as a part of a materials screening process. As an alternative to thermal cycling studies, a study of unbalanced crossply graphite fiber reinforcement composites was conducted to assess the effect of the composite ply layup and surface condition on the residual stresses that remain after the processing of these materials. The residual stresses were assessed by measuring the radii of curvature of the types of laminates that were studied. The temperature at which stress-free conditions existed were determined and a dye penetrant method was used to observe surface damage resulting from excessive residual stress buildup. These results are compared with some published results of thermal cycling tests that were previously conducted on balanced polyimide composites.

Papadopoulos, Demetrios S.↗

Arcjet Testing of Micro-Meteoroid Impacted Thermal Protection Materials

There are several harsh space environments that could affect thermal protection systems and in turn pose risks to the atmospheric entry vehicles. These environments include micrometeoroid impact, extreme cold temperatures, and ionizing radiation during deep space cruise, all followed by atmospheric entry heating. To mitigate these risks, different thermal protection material samples were subjected to multiple tests, including hyper velocity impact, cold soak, irradiation, and arcjet testing, at various NASA facilities that simulated these environments. The materials included a variety of honeycomb packed ablative materials as well as carbon-based non-ablative thermal protection systems. The present paper describes the results of the multiple test campaign with a focus on arcjet testing of thermal protection materials. The tests showed promising results for ablative materials. However, the carbon-based non-ablative system presented some concerns regarding the potential risks to an entry vehicle. This study provides valuable information regarding the capability of various thermal protection materials to withstand harsh space environments, which is critical to sample return and planetary entry missions.

Agrawal, Parul↗

Thermal support for space shuttle

The results are reported of research to provide thermal support in the design of the thermal protection system (TPS) of the space shuttles. Tasks discussed include: generation of temperature boundaries for space shuttle orbiter and booster during atmospheric reentry, leading edge and nose cap materials, TPS panel test facility support, thermal test facility support, and hot gas test facility support. A summary of thermal models generated for the space shuttle support is included.

Dean, W. G.↗

Effect of bond coat creep and oxidation on TBC integrity

The potential of thermal barrier coatings (TBCs) on high-pressure turbine (HPT) nozzles and blades is limited at present by the inability to quantitatively predict TBC life for these components. The goal is to isolate the major TBC failure mechanisms, which is part of the larger program aimed at developing TBC life prediction models. Based on the results of experiments to isolate TBC failure mechanisms, the effects of bond coat oxidation and bond coat creep on TBC integrity is discussed. In bond coat oxidation experiments, Rene prime 80 specimens coated with a NiCrAlY/ZrO2-8 percent Y2O3 TBC received isothermal pre-exposures at 2000 F in static argon, static air, or received no pre-exposure. The effects of oxidation due to the pre-exposures were determined by thermal cycle tests in both static air and static argon at 2000 F. To study the effect of bond coat creep on TBS behavior, four bond coats with different creep properties were evaluated by thermal cycle tests in air at 2000 F. The test results, the relative importance of these two failure mechanisms, and how their effects may be quantified will also be discussed.

Duderstadt, E. C.↗

Geoscience Laser Altimeter System (GLAS) Final Test Report of DM LHP TV Testing

Two loop heat pipes (LHPs) are to be used for thermal control of the Geoscience Laser Altimeter System (GLAS), planned for flight in 2001. One LHP will be used to transport 100 W from a laser to the radiator, the other will transport 210 W from electronic boxes to the radiator. In order to verify the LHP design for the GLAS application, an LHP Development Model has been fabricated, and ambient and thermal vacuum tested. Two aluminum blocks of 15 kg and 30 kg, respectively, were attached to the LHP to simulate the thermal masses connected to the heat sources. A 20 W starter heater was installed on the evaporator to aid the loop startup. A new concept to thermally couple the vapor and liquid line was also incorporated in the LHP design. Such a thermal coupling would reduce the power requirement on the compensation chamber in order to maintain the loop set point temperature. To avoid freezing of the liquid in the condenser during cold cases, propylene was selected as the working fluid. The LHP was tested under reflux mode and with adverse elevation. Tests conducted included start-up, power cycle, steady state and transient operation during hot and cold cases, and heater power requirements for the set point temperature control of the LHP. Test results showed very successful operation of the LHP under all conditions. The 20 W starter heater proved necessary in order to start the loop when a large thermal mass was attached to the evaporator. The thermal coupling between the liquid line and the vapor line significantly reduced the heater power required for loop temperature control, which was less than 5 watts in all cases, including a cold radiator. The test also demonstrated successful operation with a propylene working fluid, with successful startups with condenser temperatures as low as 100 C. Furthermore, the test demonstrated accurate control of the loop operating temperature within +/- 0.2 C, and a successful shutdown of the loop during the survival mode of operation.

Baker, Charles↗