Modeling Creep-Induced Stress Relaxation at the Leading Edge of SiC/SiC Airfoils

Anticipating the implementation of advanced SiC/SiC composites into internally cooled airfoil components within the turbine section of future aero-propulsion engines, the primary objective of this study was to develop physics-based analytical and finite-element modeling tools to predict the effects of composite creep and stress relaxation at the airfoil leading edges, which will generally experience large thermal gradients at high temperatures. A second objective was to examine how some advanced NASA-developed SiC/SiC systems coated with typical EBC materials would behave as leading edge materials in terms of long-term steady-state operating temperatures. Because of the complexities introduced by mechanical stresses inherent in internally cooled airfoils, a simple cylindrical thin-walled tube model subjected to thermal stresses only is employed for the leading edge, thereby obtaining a best-case scenario for the material behavior. In addition, the SiC/SiC composite materials are assumed to behave as isotropic materials with temperature-dependent viscoelastic creep behavior as measured in-plane on thin-walled panels. Key findings include: (1) without mechanical stresses and for typical airfoil geometries, as heat flux is increased through the leading edge, life-limiting tensile crack formation will occur first in the hoop direction on the inside wall of the leading edge; (2) thermal gradients through all current SiC/SiC systems should be kept below approx.300 F at high temperatures to avoid this cracking; (3) at temperatures near the maximum operating temperatures of advanced SiC/SiC systems, thermal stresses induced by the thermal gradients will beneficially relax with time due to creep; (4) although stress relaxation occurs, the maximum gradient should still not exceed 300oF because of residual tensile stress buildup on the airfoil outer wall during cool-down; and (5) without film cooling and mechanical stresses, the NASA-developed N26 SiC/SiC system with thru-thickness Sylramic-iBN fiber reinforcement and a typical EBC coating has the potential of offering a maximum long-term steady-state operating temperature of approx.3100 F at the surface of the EBC.

Lang, Jerry↗

Effects of Energy Capture and Recovery on an N+3 Technology Level Reference Propulsion System

An initial, parametric study was performed to assess the benefits and drawbacks of waste heat recovery on a gas turbine engine. The NASA N+3 technology level reference propulsion system model, an advanced, single-aisle class, gas turbine engine was the baseline cycle. The amount of thermal energy removed from the high-energy core flow and transferred to lower-energy bypass or removed from the cycle was varied. Total pressure losses were included parametrically, as well as the effects of converting some of that thermal energy to work used within the cycle. Propulsion system thrust and thrust specific fuel consumption (TSFC) were minimally affected by total pressure losses or thermal energy removal from the core stream. However, total pressure losses in the bypass stream had significant thrust and TSFC penalties. Those penalties were partially offset if core thermal energy is transferred to the bypass stream. Core thermal energy converted to work for use within the engine cycle via a bottoming cycle showed significant thrust and TSFC benefits. In addition to these results, an engine dataset is also being made available. The dataset contains engine conditions (mass flow rate, total temperature and pressure, flow velocities, etc.) at four flight conditions (maximum climb limit, cruise, rolling takeoff and sea level static) that can be used for specific information to guide heat exchanger design to best realize these benefits with further research. The data set is a .csv (comma-separated values) file and is provided as a supplement to this report (available online from www.sti.nasa.gov).

propulsion↗

Parametric Analysis of Cyclic Phase Change and Energy Storage in Solar Heat Receivers

A parametric study on cyclic melting and freezing of an encapsulated phase change material (PCM), integrated into a solar heat receiver, has been performed. The cyclic nature of the present melt/freeze problem is relevant to latent heat thermal energy storage (LHTES) systems used to power solar Brayton engines in microgravity environments. Specifically, a physical and numerical model of the solar heat receiver component of NASA Lewis Research Center's Ground Test Demonstration (GTD) project was developed. Multi-conjugate effects such as the convective fluid flow of a low-Prandtl-number fluid, coupled with thermal conduction in the phase change material, containment tube and working fluid conduit were accounted for in the model. A single-band thermal radiation model was also included to quantify reradiative energy exchange inside the receiver and losses through the aperture. The eutectic LiF-CaF2 was used as the phase change material (PCM) and a mixture of He/Xe was used as the working fluid coolant. A modified version of the computer code HOTTube was used to generate results in the two-phase regime. Results indicate that parametric changes in receiver gas inlet temperature and receiver heat input effects higher sensitivity to changes in receiver gas exit temperatures.

Hall, Carsie A., III↗

Thermal Ablation Modeling for Silicate Materials

A general thermal ablation model for silicates is proposed. The model includes the mass losses through the balance between evaporation and condensation, and through the moving molten layer driven by surface shear force and pressure gradient. This model can be applied in the ablation simulation of the meteoroid and the glassy ablator for spacecraft Thermal Protection Systems. Time-dependent axisymmetric computations are performed by coupling the fluid dynamics code, Data-Parallel Line Relaxation program, with the material response code, Two-dimensional Implicit Thermal Ablation simulation program, to predict the mass lost rates and shape change. The predicted mass loss rates will be compared with available data for model validation, and parametric studies will also be performed for meteoroid earth entry conditions.

Ablation↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Automated Control for Nuclear Thermal Propulsion Start-Up using MOOSE-based Applications

This report presents a Griffin/Bison/RELAP-7 numerical model of a prototypical NTP system that features fuel assemblies arranged in rings, and which was designed to simulate rapid startup transients. The physics modeled include full-core neutronics, assembly-wise heat conduction, and conjugate heat transfer, with the balance of plant mainly imposed through boundary conditions. In addition, various forms of automated reactivity control were deployed by using the MOOSE to autonomously drive the model and simulate the reactor transitioning from assumed initial conditions to nominal power in a fraction of a minute. To generate the cross-sections of the neutronics model, and in an effort to simultaneously account for the tremendous axial temperature gradients in the reactor and to limit the number of state points required for cross-section generation, the average component temperatures and hydrogen densities in the cooling channels were correlated to the average fuel and moderator temperatures, and fixed axial profiles were derived for nominal conditions and then used during the transient. With this approximation, a tractable cross-section library tabulated with fuel/moderator temperatures and CD angles was generated using Serpent. The full-core SPH correction procedure and the CD decusping technology in Griffin, respectively, ensure preservation of the multiplication factor and reaction rates at state points, along with a reasonably accurate reactivity worth between tabulated CD angles, despite using a coarse mesh. Feedback from other physics was calculated by modeling one representative fuel assembly per ring, along with the corresponding fuel and moderator cooling channels. To limit power overshoots during startup, another layer of multiphysics coupling was added to the model in order to automatically control the drums. Two different technologies presented herein showed outstanding performance in this regard: (1) a novel hybrid PID controller based on both power and reactivity signals, and (2) a PGC that relies on kinetics parameters and reactivity coefficients to predict future behavior and adjust the desired signal accordingly. A challenging benchmark was devised, featuring a power demand curve that exponentially increases by a factor of 500 within 30 seconds, then levels out after that. Both control approaches create a simulated power curve that closely follows the power demand curve and limits power overshoots to 1% or less. While the former approach requires more tuning of the internal parameters, the latter requires additional knowledge of the reactivity feedback coefficients and rates of change of the corresponding variables, including fuel and moderator temperature, which could be difficult to dynamically measure for a real NTP system. Fortunately, some inaccuracy in these quantities will not drastically degrade the PGC performance. Subsequently, a more realistic startup sequence was considered, in which the mass flow rate and outlet pressures are ramped up to model bootstrap and thrust build-up phases prior to reaching steady-state conditions, demonstrating the ability of the hybrid PID and PGCs to handle such transients, with both types of controllers exhibiting very similar behavior. Nevertheless, a significant chamber temperature overshoot was observed, caused by the demanded power signal and assumed mass flow rate. This issue could be mitigated by deploying a reactor controller that follows the chamber temperature signal and actuates both the control valves and drums (rather than using a power signal based solely on the drums to control reactivity). Enhancement of the hydrogen fluid properties available in MOOSE, as well as a better understanding of prototypical initial conditions, are also needed to further enhance this startup model. Finally, a study was performed to model decay heat post-shutdown, and to prepare for extending this model to predict shutdown behavior and post-shutdown pulsed cooling requirements.

33 ADVANCED PROPULSION SYSTEMS↗

Cooperative Transmission Expansion Planning Experiment Data and Results

GO WEST is an open-source power grid modeling framework for U.S. Western Interconnection, which allows users to tailor the model depending on their research study and science questions. It covers 28 balancing authorities (BA) and 12 states in U.S. Western Interconnection. GO WEST allows users to select different number of nodes and come up with a simplified network by utilizing 10,000 nodal topology of U.S. Western Interconnection created by Texas A&M University. Users can try and select different number of nodes, mathematical formulations (linear programming vs. mixed-integer linear programming), transmission line limit scaling factors, and hurdle rate scaling factors. GO WEST offers a unit commitment and economic dispatch (UC/ED) module to simulate grid operations on an hourly scale. In this sense, users can calibrate and validate their model versions by comparing model outputs to historical datasets. TEP is an open-source transmission capacity expansion model, built on GO WEST framework. It utilizes linear programming to optimize transmission capacity addition investment on existing lines within GO WEST framework. In this sense, TEP model only increases the thermal capacity of existing transmission lines and does not add new lines to the system, which leaves the topology preserved. TEP minimizes the total cost of the system which comprises the operational cost of satisfying electricity demand (i.e., generation cost), cost of loss of load (i.e., unserved energy), cost of power flow, and cost of new transmission capacity additions (i.e., investment cost). In order to use TEP model, users need to create scenarios with GO WEST framework. In this analysis, outputs from several models are used to create future inputs to GO WEST and TEP models, including GCAM-USA, TELL, CERF and reV. This dataset includes experiment inputs and outputs from three different transmission expansion scenarios (cooperative, intermediate, and individual) for 2019 and 2059. For 2019, a base scenario to illustrate the default (i.e., historical) power grid operations is also included. This study utilizes rcp45hotter_ssp3 scenario from a previous version of GCAM-USA simulations. Sources of the shapefiles in supplementary data are HIFLD Open and U.S. Energy Atlas. Please see the README file for a detailed description of the main and supplementary data.

Capacity Expansion Model↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage (FTES) in Crystalline Rock Formations (DEMO-FTES) (CRADA Final Report)

The DEMO-FTES project sought to demonstrate the thermal efficiency of fracture thermal energy storage (FTES) through numerical simulations, laboratory and meso-scale field tests. A detailed dimensional and scaling analysis was performed to identify key parameters and how they can be most effectively scaled to the laboratory and decameter scale. Numerical models were developed and used for three purposes: 1. Before field experiments, numerical modelling can be used to estimate fracture properties based on previous data from the EGS Collab experiment and then predict thermal hydrological behaviors of the fracture system with hot water injection/withdrawal, therefore, help to design the experiments (e.g., to decide the duration of the cycles based on the flow rate the pump can provide, and the estimated fracture properties); 2. After the field experiment, to estimate the system properties during the experiment (as the size and shape of a fracture could change over time), and understand why system performance is different than what has been predicted, i.e., to help understand the meso-scale test; and, 3. To model the lab experiments and estimate fracture properties and storage efficiency. Ultimately, the experiment and numerical models could shed light on the processes and uncertainty happening during fracture activation and help understand the scaling between lab and field test, and finally, the design and optimization of potential fracture thermal energy storage systems.

25 ENERGY STORAGE↗

A view of future technology needs for space transportation

This paper addresses an independent assessment of space transportation requirements within the NASA and Military Space Systems Technology Models. A critical examination is made of the system needs of the various flight elements with the models as compared to independent technology forecasts and possible technology deficiencies are discussed. These deficits impact the requisite developments needed for chemical propulsion, thermal protection systems, fuel cells, guidance, avionics and data processing for both launch vehicles and orbital transfer vehicles. Also addressed are potential alternative propellant technologies and their impact upon transfer vehicle systems. The primary focus of these anticipated technology developments will be to reduce operational costs, expand flexibility, and increase the payload capability of space transportation.

Gartrell, C. F.↗

Theoretical Analysis of a Single-Stage Gas-Fired Ejector Heat Pump Water Heater

Ejector driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this investigation, a single-stage gas-fired ejector heat pump (EHP) is investigated and thermodynamically modeled in order to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) temperatures on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Results show that an optimized COP of the EHP system exists which depends on HTE and LTE temperatures, primary nozzle throat diameters. In addition, it is found that the EHP COP is independent of the ejector COP. From this investigation a maximum EHP COP of 1.31 is able to be achieved for a HTE temperature of 160 °C and a LTE temperature of 19.5 °C with a total heat capacity of 15.98 kW.

Spitzenberger, Jeremy↗

Evaluating the impact of peat soils and snow schemes on simulated active layer thickness at pan-Arctic permafrost sites

Abstract Permafrost stability is significantly influenced by the thermal buffering effects of snow and active-layer peat soils. In the warm season, peat soils act as a barrier to downward heat transfer mainly due to their low thermal conductivity. In the cold season, the snowpack serves as a thermal insulator, retarding the release of heat from the soil to the atmosphere. Currently, many global land models overestimate permafrost soil temperature and active layer thickness (ALT), partially due to inaccurate representations of soil organic matter (SOM) density profiles and snow thermal insulation. In this study, we evaluated the impacts of SOM and snow schemes on ALT simulations at pan-Arctic permafrost sites using the Energy Exascale Earth System Model (E3SM) land model (ELM). We conducted simulations at the Circumpolar Active Layer Monitoring (CALM) sites across the pan-Arctic domain. We improved ELM-simulated site-level ALT using a knowledge-based hierarchical optimization procedure and examined the effects of precipitation-phase partitioning methods (PPMs), snow compaction schemes, and snow thermal conductivity schemes on simulated snow depth, soil temperature, ALT, and CO 2 fluxes. Results showed that the optimized ELM significantly improved agreement with observed ALT (e.g. RMSE decreased from 0.83 m to 0.15 m). Our sensitivity analysis revealed that snow-related schemes significantly impact simulated snow thermal insulation levels, soil temperature, and ALT. For example, one of the commonly used snow thermal conductivity schemes (quadratic Sturm or SturmQua) generally produced warmer soil temperatures and larger ALT compared to the other two tested schemes. The SturmQua scheme also amplified the model’s sensitivity to PPMs and predicted deeper ALTs than the other two snow schemes under both current and future climates. The study highlights the importance of accurately representing snow-related processes and peat soils in land models to enhance permafrost dynamics simulations.

54 ENVIRONMENTAL SCIENCES↗

Constraining the Thermal and Textural Evolution of Evolved Achondrite DOM 10100: Implications for Volatile Loss

Identification of evolved achrondritic clasts suggests that some early planetesimals experienced extensive differentiation and formed chemically evolved crusts. Many of these samples contain volatile-bearing phases (i.e., apatite, merrillite, nominally anhydrous minerals), which can be used to constrain volatile budgets and abundancies via in-situ measurements. These ancient crustal rocks are subject to high heat, moderate pressures, potentially hot mineral-rich fluids, and degassing that has likely modified many of these volatiles, and their abundancies do not represent the composition of the primary magma from which these achondrites formed. In this work we attempt to deconvolve the thermal evolution of these samples to provide petrologic information that can be used for making inferences regarding their volatile history, and ultimately constraining volatile budgets on planetary bodies in the early Solar System. Here, we combine in-situ major element geochemistry, thermodynamic modeling, and detailed textural and microstructural observations to reconstruct the thermal and textural evolution of howardite DOM 10100, which contains a dacite within its matrix. Previous analyses of several sections of DOM 10100 suggest that the dacitic clast is evidence for partial melting of Vesta’s differentiated basaltic crust, making it an ideal candidate for evolved crustal studies. While its igneous petrogenesis has been well constrained, there is still opportunity to better characterize its post-crystallization thermal history, including possible thermal metamorphism and cooling.

J S Gorce↗

Thermal metamorphism

Most chondrites have experienced thermal metamorphism, resulting in changes in texture, mineralogy and possibly chemical composition. The physical conditions for metamorphism range from approximately 400 to 1000 C at low lithostatic pressure. Metamorphism may have resulted from decay of short-lived radionuclides, electromagnetic induction or accretion of hot materials. Several thermal models for chondrite parent bodies have been proposed. The least metamorphosed type-3 chondrites probably carry the most information about the early solar system, but even these have been affected to some degree by thermal processing.

Mcsween, Harry Y., Jr.↗

Thermal Modeling of a Novel Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC)

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO 2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO 2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. The current investigation addresses the thermal modeling of potential AC-TSAC designs. An initial thermal model was created and validated by comparing the model outputs to experimental data for the heating phase. Several design trades were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), and configuration of heat spreading elements within the bed. Also investigated is AC-TSAC performance sensitivity to the thermal conductivity of the adsorbent material and the heat pipes as well as the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah S. Alpert↗

FY21 Status Report on the Molten Salt Thermal Properties Database (MSTDB) Development

This report describes the thermodynamic assessments for the ZrF 4 -BeF 2 , AlCl 3 -NaCl, AlCl3-KCl and the PuCl 3 -CsCl pseudo-binary subsystems. Calculation results are compared to the inputs used to optimize the adjustable model parameters. The data came from experimental studies reported in the open literature, from the MSR research community, and/or computational results generated within the NEAMS program and from collaborators. The models from the thermodynamic assessment of these salt systems are integrated into the MSTDB-TC (Molten Salt Thermal Properties Database-Thermochemical). A brief description of the companion MSTDB-TP (Molten Salt Thermal Properties Database-Thermophysical) is given along with an overview of the approach for predicting both thermodynamic and thermophysical property behavior of multicomponent systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Form-drag instability, multiple equilibria and propagating planetary waves in baroclinic, orographically forced, planetary wave systems

A two-layer baroclinic model is used to study the planetary-scale motions of a thermally driven atmosphere in the presence of topography, and in doing so to extend previous results obtained with a barotropic model. Highly truncated spectral equations are used to obtain multiple wavelike stationary equilibrium states, to examine the instabilities that produce them, and to study the instabilities that feed on them and give rise to traveling planetary waves. Although the equilibria cannot exist without orography, their energy comes from the potential energy of the mean flow, not from kinetic energy transfer via the mountain torque. Low-index (blocking) equilibria as well as high-index equilibria require a large thermal driving and are associated with both orographic and baroclinic instability of the Hadley circulation. It is suggested that blocking in nature is a quasi-stable circulation arising from orographic instability with strong thermal driving; and that observed low-frequency, propagating planetary waves are due to instabilities of the quasi-stationary, topographically forced equilibria.

Charney, J. G.↗

Automotive Gas Turbine Power System-Performance Analysis Code

An open cycle gas turbine numerical modelling code suitable for thermodynamic performance analysis (i.e. thermal efficiency, specific fuel consumption, cycle state points, working fluid flowrates etc.) of automotive and aircraft powerplant applications has been generated at the NASA Lewis Research Center's Power Technology Division. The use this code can be made available to automotive gas turbine preliminary design efforts, either in its present version, or, assuming that resources can be obtained to incorporate empirical models for component weight and packaging volume, in later version that includes the weight-volume estimator feature. The paper contains a brief discussion of the capabilities of the presently operational version of the code, including a listing of input and output parameters and actual sample output listings.

Juhasz, Albert J.↗

Development and Demonstration of a Reduced-Order PWR Power Dispatch Simulator

This report describes the development, modeling, and results of a reduced-order thermal power dispatch pressurized water reactor (RO-TPD-PWR) power plant simulator that incorporates coupled electrical and thermal power dispatch to an industrial process. The simulator is built on models that have been developed in previous work, including a Rancor Microworld model previously developed by INL and the University of Idaho [Ref] and reactor core and secondary system models that have been published previously [Ref]. The simulator also includes a scalable model of a high temperature electrolysis (HTE) system that has been developed at INL. A particular benefit of the Rancor Microworld model is that it is compatible with a human-system interface (HMI) that has already been developed by the Human System Simulation Laboratory (HSSL) at INL that can emulate the control room of a PWR for realistic human-in-the-loop studies with mock nuclear power plant operating procedures. The results of these human-in-the-loop tests will be compared with similar tests using a commercial full-scope generic PWR (GPWR) simulator that has been modified to include thermal power dispatch, referred to as the TPD-GPWR [ , ]. The simplicity of the RO-TPD-PWR helps to better understand and verify the results of the TPD-GPWR, which employs >1,000 variables and has much greater complexity. A second key purpose of the RO-TPD-PWR simulator is that its relative simplicity allows it scale between lab-size equipment (~100 kW) and full-scale nuclear power plants (~1 GW) by adjusting only a few parameters in the models, such as fluid masses and heat exchanger areas. The RO-TPD-PWR simulator will be used to guide the controls of lab tests, so that equipment in those tests, such as the Thermal Energy Distribution System (TEDS) and pilot-scale high temperature electrolysis (HTE) units at scales of 50-250 kW, may operate in a manner that is relevant to full-scale PWR operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗