Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind and Temperature Consensus at Horn Point, HU-Beltsville, Piney Run (Maryland) in support of CoURAGE

The Maryland Department of the Environment (MDE) operates a ground-based atmospheric profiling network consisting of collocated radar wind profilers (RWP) and radio acoustic sounding systems (RASS) as part of its Ambient Air Monitoring Program. This network provides continuous observations of wind and temperature structure in the lower troposphere to support air quality forecasting, regulatory analysis, and atmospheric research. The network currently includes three fixed sites across Maryland: Horn Point (HP, lower eastern shore) [38.587525°,-76.141006°], Howard University-Beltsville (HUB, central Maryland) [39.055277°, -76.878632°], and Piney Run (PR, western Maryland) [39.705950°, -79.012000°] The network is designed to capture regional variability in atmospheric transport and boundary-layer processes. These systems measure vertical profiles of horizontal wind speed and direction using Doppler radar techniques, with observations typically spanning from ~100 m above ground level up to approximately 2.5–4 km. Measurements are derived from the Doppler shift of backscattered electromagnetic signals, enabling retrieval of wind vectors at multiple altitudes with high temporal resolution (e.g., 30-minute averages reported every 6 minutes). Each radar wind profiler is paired with a Radio Acoustic Sounding System (RASS) to provide profiles of virtual temperature in the lower atmosphere (~100–200 m AGL) by measuring the propagation speed of acoustic waves. Together, the RWP/RASS system yields a coupled data set of thermodynamic and kinematic atmospheric structure, including additional parameters such as vertical velocity, radial velocity, signal-to-noise ratio, and spectral width for advanced analysis. There are two types of files for each station: wind data (files with a "w" prefix) and virtual temperature RASS data (files with a "t" prefix). The wind data files are in the format wYYDDD.cns, where YY is the 2-digit year and DDD is the day of the year. The RASS virtual temperature data files are in the format tYYDDD.cns. Each record has the following header structure: Line 1 : Station Name RASS files Line 2 : RASS rev DeTect_2.0, WINDS files Line 2 : WINDS rev ATI 5.1 Line 3 : N latitude, W longitude, and site elevation (m) Line 4 : Date and begin time of consensus: yy mm dd hh mn ss plus # minutes to add to get UTC Line 5 : Consensus averaging time (minutes); number of beams; number of range gates Line 6 : Number of records required to make consensus (num) total number of records (tot) and the consensus window size (m/s) in the format: num:tot (window) RASS files Line 7 : no. of coded cells, no. of spec, pulse width (ns), and inter-pulse period (µs), WINDS files Line 7 : No. of coded cells, no. of spectra, pulse width (ns), and inter-pulse period (µs), each with a pair of values: first value is for oblique beams, second for vertical RASS files Line 8 : Full scale Doppler value (m/s) Delay to first gate (ns) Number of gates Spacing of gates (ns), WINDS files Line 8 : Full scale Doppler velocity (m/s), oblique and vertical Vertical correction applied to oblique beams? (0 = no, 1 = yes) Delay to first gate (ns), oblique and vertical Number of gates, oblique and vertical Spacing of gates (ns), oblique and vertical Line 9 : Azimuth and elevation (9s indicate vertical beam not used) RASS files Line 10, values : HT = Height above ground (km), T = Uncorrected virtual temperature consensus (deg C), Tc = Corrected virtual temperature consensus (deg C), W = Vertical wind consensus (9s indicate vertical beam not used, w-component, positive upward, m/s), CNT = Number of records that made consensus (for the 3 values in same order), SNR = Average signal to noise ratio (dB) of records in consensus (same order) WINDS files Line 10, values : HT = Height above ground (km), SPD = Wind speed (m/s), DIR = Wind direction (deg E of N from N), RAD = Radial velocities for each beam (m/s) in order given in azimuth and elevation line (positive toward radar; 9s indicate vertical beam not used, CNT = Number of records that made consensus, SNR = Average signal to noise ratio (dB) of records in consensus

{"wind speed and direction",temperature}↗

Operating Temperatures of a Sodium-Cooled Exhaust Valve as Measured by a Thermocouple

A thermocouple was installed in the crown of a sodium-cooled exhaust valve. The valve was then tested in an air-cooled engine cylinder and valve temperatures under various engine operating conditions were determined. A temperature of 1337 F was observed at a fuel-air ratio of 0.064, a brake mean effective pressure of 179 pounds per square inch, and an engine speed of 2000 rpm. Fuel-air ratio was found to have a large influence on valve temperature, but cooling-air pressure and variation in spark advance had little effect. An increase in engine power by change of speed or mean effective pressure increased the valve temperature. It was found that the temperature of the rear spark-plug bushing was not a satisfactory indication of the temperature of the exhaust valve.

FUEL-AIR MIXTURES↗

The rate of the reaction between CN and C2H2 at interstellar temperatures

The rate coefficient for the important interstellar reaction between CN and C2H2 has been calculated as a function of temperature between 10 and 300 K. The potential surface for this reaction has been determined through ab initio quantum chemical techniques; the potential exhibits no barrier in the entrance channel but does show a small exit channel barrier, which lies below the energy of reactants. Phase-space calculations for the reaction dynamics, which take the exit channel barrier into account, show the same unusual temperature dependence as determined by experiment, in which the rate coefficient at first increases as the temperature is reduced below room temperature and then starts to decrease as the temperature drops below 50-100 K. The agreement between theory and experiment provides strong confirmation that the reaction occurs appreciably at cool interstellar temperatures.

NASA Discipline Exobiology↗

Control of continuous irradiation injury on potatoes with daily temperature cycling

Two controlled-environment experiments were conducted to determine the effects of temperature fluctuations under continuous irradiation on growth and tuberization of two potato (Solanum tuberosum L.) cultivars, Kennebec and Superior. These cultivars had exhibited chlorotic and stunted growth under continuous irradiation and constant temperatures. The plants were grown for 4 weeks in the first experiment and for 6 weeks in the second experiment. Each experiment was conducted under continuous irradiation of 400 micromoles per square meter per second of photosynthetic photon flux and included two temperature treatments: constant 18 degrees C and fluctuating 22 degrees C/14 degrees C on a 12-hour cycle. A common vapor pressure deficit of 0.62 kilopascal was maintained at all temperatures. Plants under constant 18 degrees C were stunted and had chlorotic and abscised leaves and essentially no tuber formation. Plants grown under the fluctuating temperature treatment developed normally, were developing tubers, and had a fivefold or greater total dry weight as compared with those under the constant temperature. These results suggest that a thermoperiod can allow normal plant growth and tuberization in potato cultivars that are unable to develop effectively under continuous irradiation.

NASA Program CELSS↗

Utilization of potatoes for life support in space. V. Evaluation of cultivars in response to continuous light and high temperature

Twenty-four potato (Solanum tuberosum L.) cultivars from different regions of the world were evaluated in terms of their responses to continuous light (24 h photoperiod) and to high temperature (30 C) in two separate experiments under controlled environments. In each experiment, a first evaluation of the cultivars was made at day 35 after transplanting, at which time 12 cultivars exhibiting best growth and tuber initiation were selected. A final evaluation of the 12 cultivars was made after an additional 21 days of growth, at which time plant height, total dry weight, tuber dry weight, and tuber number were determined. In the continuous light evaluation, the 12 selected cultivars were Alaska 114, Atlantic, Bintje, Denali, Desiree, Haig, New York 81, Ottar, Rutt, Snogg, Snowchip, and Troll. In the high temperature evaluation, the 12 selected cultivars were Alpha, Atlantic, Bake King, Denali, Desiree, Haig, Kennebec, Norland, Russet Burbank, Rutt, Superior, and Troll. Among the cultivars selected under continuous irradiation, Desiree, Ottar, Haig, Rutt, Denali and Alaska showed the best potential for high productivity whereas New York 81 and Bintje showed the least production capability. Among the cultivars selected under high temperature, Rutt, Haig, Troll and Bake King had best performance whereas Atlantic, Alpha, Kennebec and Russet Burbank exhibited the least production potential. Thus, Haig and Rutt were the two cultivars that performed well under continuous irradiation and high temperature conditions, and could have maximum potential for adaptation to varying stress environments. These two cultivars may have the best potential for use in future space farming in which continuous light and/or high temperature conditions may exist. However, cultivar responses under combined conditions of continuous light and high temperature remains for further validation.

NASA Discipline Life Support Systems↗

The Closure of the Ocean Mixed Layer Temperature Budget using Level-Coordinate Model Fields

Entrainment is an important element of the mixed layer mass, heat, and temperature budgets. Conventional procedures to estimate entrainment heat advection often do not permit the closure of heat and temperature budgets because of inaccuracies in its formulation. In this study a rigorous approach to evaluate the effect of entrainment using the output of a general circulation model (GCM) that does not have an explicit prognostic mixed layer model is described. The integral elements of the evaluation are 1) the rigorous estimates of the temperature difference between mixed layer water and entrained water at each horizontal grid point, 2) the formulation of the temperature difference such that the budget closes over a volume greater than one horizontal grid point, and 3) the apparent warming of the mixed layer during the mixed layer shoaling to account for the weak vertical temperature gradient within the mixed layer. This evaluation of entrainment heat advection is compared with the estimates by other commonly used ad hoc formulations by applying them in three regions: the north-central Pacific, the Kuroshio Extension, and the Nino-3 areas in the tropical Pacific. In all three areas the imbalance in the mixed layer temperature budget by the ad hoc estimates is significant, reaching a maximum of about 4 K yr(exp -1).

temperature gradient↗

Challenges in Characterizing Low-Temperature Regolith Properties

The success or failure of in-situ resource utilization for planetary surface exploration--be it for scientific, colonization or commercialization purposes--relies heavily on the ability to design and implement systems which effectively process the associated regolith and exploit its benefits. In most cases this challenge necessarily includes the characterization of low-temperature (cryogenic) properties; as many celestial destinations of interest, such as the moon, Mars and asteroids, have little or no atmosphere to help sustain the consistently "high" surface temperatures seen on planets such as Earth, and therefore can experience permanent cryogenic temperatures or dramatic cyclical changes. Characterization of physical properties (such as specific heat, thermal and electrical conductivity, etc.) over the entire temperature profile is undoubtedly an important piece of the puzzle; however, the impact on mechanical properties due to the introduction of icy deposit must also be explored in order to devise effective and robust excavation technologies. Currently the Granular Mechanics and Regolith Operations Lab and the Cryogenics Test Lab at NASA Kennedy Space Center are developing technologies and experimental methods to address these challenges and aid in the characterization of physical and mechanical properties of regolith at cryogenic temperatures. This presentation will review the current state of knowledge concerning lunar regolith at low temperature including that of icy regolith.

Cryogenics↗

Characterization and Correction of Aquarius Long Term Calibration Drift Using On-Earth Brightness Temperature Refernces

The Aquarius/SAC-D mission was launched on June 10, 2011 from Vandenberg Air Force Base. Aquarius consists of an L-band radiometer and scatterometer intended to provide global maps of sea surface salinity. One of the main mission objectives is to provide monthly global salinity maps for climate studies of ocean circulation, surface evaporation and precipitation, air/sea interactions and other processes. Therefore, it is critical that any spatial or temporal systematic biases be characterized and corrected. One of the main mission requirements is to measure salinity with an accuracy of 0.2 psu on montly time scales which requires a brightness temperature stability of about 0.1K, which is a challenging requirement for the radiometer. A secondary use of the Aquarius data is for soil moisture applications, which requires brightness temperature stability at the warmer end of the brightness temperature dynamic range. Soon after launch, time variable drifts were observed in the Aquarius data compared to in-situ data from ARGO and models for the ocean surface salinity. These drifts could arise from a number of sources, including the various components of the retrieval algorithm, such as the correction for direct and reflected galactic emission, or from the instrument brightness temperature calibration. If arising from the brightness temperature calibration, they could have gain and offset components. It is critical that the nature of the drifts be understood before a suitable correction can be implemented. This paper describes the approach that was used to detect and characterize the components of the drift that were in the brightness temperature calibration using on-Earth reference targets that were independent of the ocean model.

Aquarius↗

Surface Temperature Measurements from a Stator Vane Doublet in a Turbine Engine Afterburner Flame Using a YAG:Tm Thermographic Phosphor

Luminescence-based surface temperature measurements were obtained from a YAG:Tm-coated stator vane doublet exposed to the afterburner flame of a J85 test engine at University of Tennessee Space Institute (UTSI). The objective of the testing was to demonstrate that reliable surface temperatures based on luminescence decay of a thermographic phosphor producing short-wavelength emission could be obtained from the surface of an actual engine component in a high gas velocity, highly radiative afterburner flame environment. YAG:Tm was selected as the thermographic phosphor for its blue emission at 456 nm (1D23F4 transition) and UV emission at 365 nm (1D23H6 transition) because background thermal radiation is lower at these wavelengths, which are shorter than those of many previously used thermographic phosphors. Luminescence decay measurements were acquired using a probe designed to operate in the afterburner flame environment. The probe was mounted on the sidewall of a high-pressure turbine vane doublet from a Honeywell TECH7000 turbine engine coated with a standard electron-beam physical vapor deposited (EB-PVD) 200-m-thick TBC composed of yttria-stabilized zirconia (YSZ) onto which a 25-m-thick YAG:Tm thermographic phosphor layer was deposited by solution precursor plasma spray (SPPS). Spot temperature measurements were obtained by measuring luminescence decay times at different afterburner power settings and then converting decay time to temperature via calibration curves. Temperature measurements using the decays of the 456 and 365 nm emissions are compared. While successful afterburner environment measurements were obtained to about 1300C with the 456 nm emission, successful temperature measurements using the 365 nm emission were limited to about 1100C due to interference by autofluorescence of probe optics at short decay times.

thermographic phosphor↗

Long-Term Changes/Trends in Surface Temperature and Precipitation During the Satellite Era (1979-2012)

During the post-1979 period in which the satellite-based precipitation measurements with global coverage are available, global mean surface temperature rapidly increased up to late 1990s, followed by a period of temperature hiatus after about 19981999. Comparing observed surface temperature trends against the simulated ones by the CMIP5 historical experiments especially in the zonal mean context suggests that although the anthropogenic greenhouse-gases (GHG) forcing has played a major role, in addition to the anthropogenic aerosols and various natural forcings, the effects from decadal-to-interdecadal scale internal modes specifically the Pacific Decadal Oscillation(PDO) are also very strong. Evident temperature changes associated with the PDOs phase shift are seen in the Pacific basin, with decadal-scale cooling in the tropical central-eastern Pacific and most of the east basin and concurrent warming in the subtropics of both hemispheres,even though the PDOs net effect on global mean temperature is relatively weak. The Atlantic Multidecadal Oscillation(AMO) also changed its phase in the mid-1990s, and hence its possible impact is estimated and assessed as well.However, comparisons with CMIP5 simulations suggest that the AMO may have not contributed as significantly as the PDO in terms of the changes trends in global surface temperature, even though the data analysis technique used here suggests otherwise. Long-term precipitation changes or trends during the post-1979 period are further shown to have been modulated by the two major factors:anthropogenic GHG and PDO, in addition to the relatively weak effects from aerosols and natural forcings. The spatial patterns of observed precipitation trends in the Pacific,including reductions in the tropical central-eastern Pacific and increases in the tropical western Pacific and along the South Pacific Convergence Zone, manifest the PDOs contributions.Removing the PDO effect from the total precipitation trends makes the spatial structures of precipitation trends more similar to those simulated by CMIP5 historical full forcing experiments particularly in the context of zonal-mean results. This also confirms that in spite of the PDO effect specifically on regional scales, the anthropogenic GHG signals are still discernible in observed precipitation during the time period. Following the increase of GHG, precipitation tends to increase roughly along the climatological ITCZ and decrease south of the equator and in the subtropics of both hemispheres.

GPCP↗

Global Crop Production: Adaptation to Temperature Increase Is Possible by Maintaining the Current Growing Periods

Increasing temperature trends are expected to impact yields of major field crops by affecting various plant processes, such as phenology and growth. However, future projections, especially at the global scale, do not consider any agronomic adaptation in farming practices. We use an ensemble of seven Global Gridded Crop Models (GGCMs) contributing to the AgMIP-Gridded project to quantify the impacts and adaptation potential of field crops under increasing temperature. We study how uniform warming scenarios up to 6 K affect the productivity and growing period duration of five major crops. The design of the experiment aims at understanding adaptation measures targeted to temperature-driven impacts and therefore leaves out changes in any other climate variable. We find that, without adaptation the dominant effect of temperature increase is to shorten the growing period and to reduce yields and production, consistently across crops and regions. We then test the potential of two agronomic measures to contrast warming-induced yield reduction, assuming that (i) cultivars with adjusted phenology would be used to regain the reference growing period duration; (ii) rainfed systems would be converted to irrigated. Despite substantial uncertainties in model parametrization and little agreement in spatial patterns, at the global aggregation, model results are robust. We find that up to 3 K of temperature increase, production losses could be fully compensated by maintaining the original crop growing period. Irrigation would also compensate production losses, but would not reduce the temperature impacts. Across regions, the model ensemble estimates larger adaptation potentials from unchanged growing periods in continental and temperate regions, than in tropical and arid regions, where also irrigation has respectively little effects and availability.

Irrigation↗

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen↗

Steady State Temperature Profile in a Cylinder Heated by Microwaves

We have developed a new theory to calculate the steady state temperature profile in a cylindrical sample positioned along the entire axis of a cylindrical microwave cavity. Temperature profiles were computed for alumina rods of various radii contained in a cavity excited in one of the TM0n0 modes with n = 1, 2, or 3. Sample surface and center temperatures will be presented as a function of total sample absorbed power or electric field strength at the sample surface. An approach for attaining more uniform heating within the sample by reducing the magnitude of the inverted temperature profile using a concentric outer cylindrical tube will be discussed. Also, parametric studies will be reported for model calculations in which the total hemispherical emissivity was varied at boundaries of the sample and surrounding tube and at the cavity wall. The results will be discussed in the context of controlling both the average sample temperature and the temperature distribution in the sample during microwave processing.

steady-state↗

Impacts of Water Clarity Variability on Temperature and Biogeochemistry in the Chesapeake Bay

Estuarine water clarity depends on the concentrations of aquatic constituents, such as colored dissolved organic matter, phytoplankton, inorganic suspended solids, and detritus, which are influenced by variations in riverine inputs. These constituents directly affect temperature because when water is opaque, sunlight heats a shallower layer of the water compared to when it is clear. Despite the importance of accurately predicting temperature variability, many numerical modeling studies do not adequately account for this key process. In this study, we quantify the effect of water clarity on heating by comparing two simulations of a hydrodynamic-biogeochemical model of the Chesapeake Bay for the years 2001–2005, in which (1) water clarity is constant in space and time for the computation of solar heating, compared to (2) a simulation where water clarity varies with modeled concentrations of light-attenuating materials. In the variable water clarity simulation, the water is more opaque, particularly in the northern region of the Bay. This decrease in water clarity reduces the total heat, phytoplankton, and nitrate throughout the Bay. During the spring and summer months, surface temperatures in the northern Bay are warmer by 0.1 °C and bottom temperatures are colder by 0.2 °C in the variable light attenuation simulation. Warmer surface temperatures encourage phytoplankton growth and nutrient uptake near the head of the Bay, and fewer nutrients are transported downstream. These impacts are greater during higher river flow years, when differences in temperature, nutrients, phytoplankton, and zooplankton extend further seaward compared to other years. This study demonstrates the consequences of utilizing different light calculations for estuarine heating and biogeochemistry.

water clarity↗

Greenland and Canadian Arctic Ice Temperature Profiles Database

Here, we present a compilation of 95 ice temperature profiles from 85 boreholes from the Greenland ice sheet and peripheral ice caps, as well as local ice caps in the Canadian Arctic. Profiles from only 31 boreholes (36 %) were previously available in open-access data repositories. The remaining 54 borehole profiles (64 %) are being made digitally available here for the first time. These newly available profiles, which are associated with pre-2010 boreholes, have been submitted by community members or digitized from published graphics and/or data tables. All 95 profiles are now made available in both absolute (meters) and normalized (0 to 1 ice thickness) depth scales and are accompanied by extensive metadata. These metadata include a transparent description of data provenance. The ice temperature profiles span 70 years, with the earliest profile being from 1950 at Camp VI, West Greenland. To highlight the value of this database in evaluating ice flow simulations, we compare the ice temperature profiles from the Greenland ice sheet with an ice flow simulation by the Parallel Ice Sheet Model (PISM). We find a cold bias in modeled near-surface ice temperatures within the ablation area, a warm bias in modeled basal ice temperatures at inland cold-bedded sites, and an apparent underestimation of deformational heating in high-strain settings. These biases provide process level insight on simulated ice temperatures.

Greenland↗

Short-Term Elevated Temperature Mechanical Performance and Microstructure of A Niobium-Zirconium Alloy Produced via Laser Powder Bed Fusion In-Situ Alloying

Nb-1Zr is a readily fabricable, dispersion-strengthened niobium alloy with improved elevated temperature properties compared to commercially pure niobium. This low to moderate strength niobium alloy is desirable in thermal management systems for fission power and propulsion applications; however, pre-alloyed spherical feedstock for powder-based additive manufacturing processes is generally unavailable. Laser powder bed fusion (L-PBF) in-situ alloying of a Nb-1Zr chemistry was performed using a high-purity niobium feedstock coated with 1 wt% of zirconium-based ceramic compound nano-powders: ZrO 2 , ZrC, and ZrH 2 . The additively manufactured material was mechanically tested at elevated temperatures within a controlled environment in the as-built condition. For comparison, traditionally manufactured wrought feedstock was also tested within an identical environment. Examination of the materials’ microstructure and short-term elevated temperature mechanical response determined: in-situ alloying of spherical Nb powder feedstock with Zr-based ceramic nanoparticles can be successfully implemented; the ZrO 2 addition offered the greatest elevated temperature stability and strength but exhibited brittle behavior; the ZrC addition achieved a balance of room temperature ductility and elevated temperature strength; and the ZrH 2 -modified material had the lowest as-built interstitial content and showed high ductility with mechanical performance most similar to wrought Nb-1Zr.

Niobium Alloy↗

Study of effect of PWR cold leg temperature gradient on reactor core condition

Effects of temperature and flow gradients in Westinghouse designed three-loop Pressurized Water Reactor (PWR) cold legs, the piping between the main coolant pump and the reactor vessel, were evaluated using Computational Fluid Dynamics (CFD) code STAR CCM+ and coupled neutronic and thermal-hydraulic (T/H) code system VERA. In the parametric study, several symmetric and asymmetric temperature gradients that were significantly larger than those observed from plant measurements were applied to the cold leg inlets for comparison with the base case without any temperature gradient. A CFD model using the STAR-CCM+ code was developed for a portion of the RCS region between the Reactor Coolant Pump (RCP) and the core inlet based on previously validated modeling approach. The CFD simulation results were processed for the temperature and flow rate distributions at the core inlet as input to the VERA calculations. The VERA code system consists of COBRA-TF (CTF) for thermal-hydraulics, MPACT for reactor physics and neutron transport, and ORIGEN for isotopic depletion. The VERA model was for depletion calculations of a high-burnup loading pattern with the reactor core in pin-by-pin and subchannel resolution. The results of the study indicate that the postulated temperature gradients within the PWR cold legs do not result in any significant changes in the core inlet temperature distributions and the core power distributions during the reactor operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗