Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Precision processing of earth image data

Precise corrections of Landsat data are useful for generating land-use maps, detecting various crops and determining their acreage, and detecting changes. The paper discusses computer processing and visualization techniques for Landsat data so that users can get more information from the imagery. The elementary unit of data in each band of each scene is the integrated value of intensity of reflected light detected in the field of view by each sensor. To develop the basic mathematical approach for precision correction of the data, differences between positions of ground control points on the reference map and the observed control points in the scene are used to evaluate the coefficients of cubic time functions of roll, pitch, and yaw, and a linear time function of altitude deviation from normal height above local earth's surface. The resultant equation, termed a mapping function, corrects the warped data image into one that approximates the reference map. Applications are discussed relative to shade prints, extraction of road features, and atlas of cities.

Bernstein, R.↗

High-Procession Eye Tracking Using Fundus Images

Fundus images provide high optical gain for eye movement tracking, i.e. large image displacements occur as a result of small eye rotations. Subpixel registration techniques can provide resolution better than 1 arc minute using images acquired with a CCD camera. Ocular torsion may also be estimated, with a precision of approximately 0.1 degree. This talk will discuss the software algorithms used to attain this performance.

Mulligan, Jeffrey B.↗

Image-based novel fault detection with deep learning classifiers using hierarchical labels

One important characteristic of modern fault classification systems is the ability to flag the system when faced with previously unseen fault types. This work considers the unknown fault detection capabilities of deep neural network-based fault classifiers. Specifically, we propose a methodology on how, when available, labels regarding the fault taxonomy can be used to increase unknown fault detection performance without sacrificing model performance. To achieve this, we propose to utilize soft label techniques to improve the state-of-the-art deep novel fault detection techniques during the training process and novel hierarchically consistent detection statistics for online novel fault detection. Lastly, we demonstrated increased detection performance on novel fault detection in inspection images from the hot steel rolling process, with results well replicated across multiple scenarios and baseline detection methods.

42 ENGINEERING↗

Atomic force microscopy phase imaging of epitaxial graphene films

Abstract Dynamic mode atomic force microscopy phase imaging is known to produce distinct contrast between graphene areas of different atomic thickness. But the intrinsic complexity of the processes controlling the tip motion and the phase angle shift excludes its use as an independent technique for a quantitative type of analysis. By investigating the relationship between the phase shift, the tip-surface interaction, and the thickness of the epitaxial graphene areas grown on silicon carbide, we shed light on the origin of such phase contrast, and on the complex energy dissipation processes underlying phase imaging. In particular, we study the behavior of phase shift and energy dissipation when imaging the interfacial buffer layer, single-layer, and bilayer graphene regions as a function of the tip-surface separation and the interaction forces. Finally, we compare these results with those obtained on differently-grown quasi free standing single- and bilayer graphene samples.

Lavini, Francesco (ORCID:0000000257223040)↗

Correlation of SWIR imaging with LPBF 304L stainless steel part properties

In the Laser Powder Bed Fusion (LPBF) process, the local thermal history can vary significantly over a part as the heat transfer characteristics and the laser scan path are geometry dependent. The variations introduce the potential for defects that lead to part failure, some of which are difficult to identify non-destructively with common ex-situ evaluation techniques. These defects include significant microstructural and mechanical property differences in the part interiors. In this paper, thermal features are extracted from in-situ Short-Wave Infrared (SWIR) imaging measurements to compile voxel based part representations and understand how the complexities in the thermal history affect part performance. The deviations in thermal features due to different laser processing parameters and complex scan pathing are explored. Empirical correlations are developed to map thermal features with the engineering properties (bulk yield strength, area percentage porosity, and local state) of 304L stainless steel parts manufactured by LPBF. Processing modes (insufficient melting and keyholing) are determined by mapping part property measurements with multiple thermal features. Generating the relationships between thermographic measurements and resulting SLM part properties lays the foundation for in-situ part qualification.

36 MATERIALS SCIENCE↗

Dynamic fracture processes in hydrogen embrittled iron

Mechanistic understanding of hydrogen embrittlement is critical to the transport and storage of hydrogen as a sustainable fuel. Experimental observation of dynamic fracture processes in hydrogen environments has been challenging. Here, in-situ transmission X-ray microscopy is used to image polycrystalline iron foils that are concurrently strained and electrochemically charged with hydrogen. Using this technique, voids and microcracks down to ∼30 nm in size are identified at or near the crack tip and tracked as strain is increased. We observe both hydrogen-induced transgranular failure and hydrogen-induced intergranular failure with distinct fracture processes. We find that transgranular fracture occurs through the formation of sharp branched structures at the main crack tip that are reminiscent of slip band formation. This is followed by void growth and coalescence, and interaction with secondary cracks that lead to propagation of the main crack. Intergranular fracture is found to occur through void coalescence along grain boundaries, along with significant secondary cracking near the crack tip. The crack growth rate is greater for void-mediated intergranular failure than for slip-mediated transgranular failure. Additionally, the removal of hydrogen results in recovered ductility for a crack initially propagated under hydrogen charging.

36 MATERIALS SCIENCE↗

A sub-sampled approach to extremely low-dose STEM

The inpainting of deliberately and randomly sub-sampled images offers a potential means to image specimens at a high resolution and under extremely low-dose conditions (≤1 e - /Å 2 ) using a scanning transmission electron microscope. We show that deliberate sub-sampling acquires images at least an order of magnitude faster than conventional low-dose methods for an equivalent electron dose. More importantly, when adaptive sub-sampling is implemented to acquire the images, there is a significant increase in the resolution and sensitivity which accompanies the increase in imaging speed. Lastly, we demonstrate the potential of this method for beam sensitive materials and in-situ observations by experimentally imaging the node distribution in a metal-organic framework.

47 OTHER INSTRUMENTATION↗

End-of-injection fuel dribble of multi-hole diesel injector: Comprehensive investigation of phenomenon and discussion on control strategy

The needle shutdown of fuel injectors leads to an undesired fuel dribble that forms unburned hydrocarbons and decreases the engine thermal efficiency in modern engines. Understanding of the fuel dribbling process is of great importance to establish its minimization strategy for optimal use of conventional fuels. However, the detailed needle dynamics and in- and near-nozzle flow characteristics governing the fuel dribble process have not been thoroughly understood. In this study, the needle dynamics, in- and near-nozzle flow characteristics and fuel dribble of a mini-sac type three-hole diesel injector were investigated using a highspeed X-ray phase-contrast imaging technique at different injection pressures. The results showed that an increase in injection pressure increased the flow evacuation velocity at the needle close that induced a more intense fuel cavitation and air ingestion inside the nozzle. The fuel dribbling process showed a high shot-toshot deviation. A statistical analysis of 50-shot results exhibited two breakup modes of fuel dribble determined by the flow evacuation velocity at the needle close and presence of air ingestion. In the first mode, the fast breakup with a short residence time of fuel dribble occurred. Meanwhile, the dripping of undisturbed liquid column with a long residence time of fuel dribble occurred in the second mode. An increase in injection pressure increased the population of the first mode due to more intense air ingestion that primarily caused by an increase in needle closing speed other than an increase in peak injection velocity. Based on the results, the formation mechanism and control strategies of the fuel dribble from modern diesel injectors were discussed.

Moon, Seoksu↗

Ultrasound Thermal Field Imaging of Opaque Fluids

We have initiated an experimental program to develop an ultrasound system for non-intrusively imaging the thermal field in opaque fluids under an externally imposed temperature gradient. Many industrial processes involve opaque fluids, such as molten metals, semiconductors, and polymers, often in situations in which thermal gradients are important. For example, one may wish to understand semiconductor crystal growth dynamics in a Bridgman apparatus. Destructive testing of the crystal after the process is completed gives only indirect information about the fluid dynamics of the formation process. Knowledge of the coupled thermal and velocity fields during the growth process is then essential. Most techniques for non-intrusive velocity and temperature measurement in fluids are optical in nature, and hence the fluids studied must be transparent. In some cases (for example, LDV (laser Doppler velocimetry) and PIV (particle imaging velocimetry)) the velocities of small neutrally buoyant seed particles suspended in the fluid, are measured. Without particle seeding one can use the variation of the index of refraction of the fluid with temperature to visualize, through interferometric, Schlieren or shadowgraph techniques, the thermal field. The thermal field in turn gives a picture of the pattern existing in the fluid. If the object of study is opaque, non-optical techniques must be used. In this project we focus on the use of ultrasound, which propagates easily through opaque liquids and solids. To date ultrasound measurements have almost exclusively relied on the detection of sound scattered from density discontinuities inside the opaque material of interest. In most cases it has been used to visualize structural properties, but more recently the ultrasound Doppler velocimeter has become available. As in the optical case, it relies on seed particles that scatter Doppler shifted sound back to the detector. Doppler ultrasound techniques are, however, not useful for studying convective fluid flow in crystal growth, because particle seeding is unacceptable and flow velocities are typically too low to be resolved, and may be even lower in microgravity conditions where buoyancy forces are negligible. We will investigate a different use of ultrasound to probe the flows of opaque fluids non-intrusively and without the use of seed particles: our goal is to ultrasonically visualize the thermal field of opaque fluids with relatively high spatial resolution. The proposed technique relies upon the variation of sound speed with temperature of the fluid. A high frequency ultra-sound pulse passing through a fluid-filled chamber will traverse the chamber in a time determined by the relevant chamber dimension and the temperature of the fluid through which the pulse passes. With high time-resolution instrumentation that compares the excitation signal with the received pulse we can detect the influence of the fluid temperature on the pulse travel time. This is effectively an interferometric system, which in its optical form is an extremely sensitive approach to measuring thermal fields in fluids. Moreover, the temperature dependence of sound velocity in liquid metals is comparable to the temperature dependence of the speed of light required for accurate interferometric thermal images in transparent fluids. With an array of transducers scanned electronically a map of the thermal field over the chamber could be produced. An alternative approach would be to use the ultrasound analog of the shadowgraph technique. In the optical version, collimated light passes through the fluid, where it is focused or defocused locally by temperature field induced variations of the index of refraction. The resulting image reveals the thermal field through the spatial pattern of light intensity variations. By analogy, an ultrasound plane wave traversing an opaque fluid sample would be also locally focused or defocused depending on the speed of sound variations, giving rise to spatial variations in sound intensity that will reveal the thermal field pattern. These approaches could be applied to any situation in which temperature differences are expected to occur, and will rapidly provide information about the flow that simply cannot be obtained by any current intrusive or non-intrusive diagnostic technique. As materials processing in microgravity matures it will become increasingly important to have available simple and versatile diagnostic tools, such as we will develop, for studying the flows of opaque fluids under thermal forcing.

Andereck, C. David↗

Data-driven materials research enabled by natural language processing and information extraction

Given the emergence of data science and machine learning throughout all aspects of society, but particularly in the scientific domain, there is increased importance placed on obtaining data. Data in materials science are particularly heterogeneous, based on the significant range in materials classes that are explored and the variety of materials properties that are of interest. This leads to data that range many orders of magnitude, and these data may manifest as numerical text or image-based information, which requires quantitative interpretation. The ability to automatically consume and codify the scientific literature across domains - enabled by techniques adapted from the field of natural language processing - therefore has immense potential to unlock and generate the rich datasets necessary for data science and machine learning. This review focuses on the progress and practices of natural language processing and text mining of materials science literature and highlights opportunities for extracting additional information beyond text contained in figures and tables in articles. Here, we discuss and provide examples for several reasons for the pursuit of natural language processing for materials, including data compilation, hypothesis development, and understanding the trends within and across fields. Current and emerging natural language processing methods along with their applications to materials science are detailed. We, then, discuss natural language processing and data challenges within the materials science domain where future directions may prove valuable.

36 MATERIALS SCIENCE↗

Optical correlator techniques applied to robotic vision

Vision processing is one of the most computationally intensive tasks required of an autonomous robot. The data flow from a single typical imaging sensor is roughly 60 Mbits/sec, which can easily overload current on-board processors. Optical correlator-based processing can be used to perform many of the functions required of a general robotic vision system, such as object recognition, tracking, and orientation determination, and can perform these functions fast enough to keep pace with the incoming sensor data. We describe a hybrid digital electronic/analog optical robotic vision processing system developed at Ames Research Center to test concepts and algorithms for autonomous construction, inspection, and maintenance of space-based habitats. We discuss the system architecture design and implementation, its performance characteristics, and our future plans. In particular, we compare the performance of the system to a more conventional all digital electronic system developed concurrently. The hybrid system consistently outperforms the digital electronic one in both speed and robustness.

Hine, Butler P., III↗

Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First application of dynamic infrared imaging in boron neutron capture therapy for cutaneous malignant melanoma

Purpose: The purpose of this study is to assess the potential of dynamic infrared imaging (DIRI) as a functional, noninvasive technique for evaluating the skin acute toxicity and tumor control within the framework of the Argentine boron neutron capture therapy (BNCT) program for cutaneous malignant melanoma. Methods: Two patients enrolled in the Argentine phase I/II BNCT clinical trial for cutaneous malignant melanoma were studied with DIRI. An uncooled infrared camera, providing a video output signal, was employed to register the temperature evolution of the normal skin and tumor regions in patients subjected to a mild local cooling (cold stimulus). In order to study the spatial correlation between dose and acute skin reactions, three-dimensional representations of the superficial dose delivered to skin were constructed and cameralike projections of the dose distribution were coregistered with visible and infrared images. Results: The main erythematous reaction was observed clinically between the second and fifth week post-BNCT. Concurrently, with its clinical onset, a reactive increase above the basal skin temperature was observed with DIRI in the third week post-BNCT within regions that received therapeutic doses. Melanoma nodules appeared as highly localized hyperthermic regions. 2 min after stimulus, these regions reached a temperature plateau and increased in size. Temperature differences with respect to normal skin up to 10 deg. C were observed in the larger nodules. Conclusions: Preliminary results suggest that DIRI, enhanced by the application of cold stimuli, may provide useful functional information associated with the metabolism and vasculature of tumors and inflammatory processes related to radiation-induced changes in the skin as well. These capabilities are aimed at complementing the clinical observations and standard imaging techniques, such as CT and Doppler ultrasound.

61 RADIATION PROTECTION AND DOSIMETRY↗

An immersed interface method for microstructure-scale electrochemical battery models: numerical formulation and performance portable implementation

We present the numerical formulation, verification, and performance portable implementation of an immersed interface method for microstructure scale electrochemical modeling of batteries. The innovation in this approach is the resolution of chemical species and electrostatic potential discontinuities at active interfaces without the use of interface conforming unstructured grids. A unified formulation on Cartesian grids for all domains (electrodes and electrolyte) is used with interfacial flux conditions applied using volume fraction or “color” function gradients. We have developed one dimensional and two dimensional test cases with analytic solutions for electrochemical modeling using which we verified the consistency and accuracy of our scheme. Our solver is also validated against solutions from a macroscale model and an unstructured multi-subdomain solver for a full lithium ion cell. We then demonstrated the utility of our solver on an image-based complex battery electrode microstructure at high charging rate. Our technique also exhibits good scalability on distributed memory architectures using central processing units (CPU), with problem sizes up to 1.8 billion degrees of freedom and with 5400 ranks. Initial performance studies of our open-source performance portable solver showed about 70 times speed up using a graphics processing unit (GPU) compared to single compute core for a problem with 4 million cells.

25 ENERGY STORAGE↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensing performances of ZnO nanostructures grown under different oxygen pressures to hydrogen

Graphical abstract: Display Omitted Highlights: ► Surface morphology depends on the oxygen pressure. ► Structural degradation was observed for the ZnO samples when oxygen pressure was overhigh. ► The sensitivity of the ZnO-based sensors increase with grown oxygen pressure. -- Abstract: For extensive use in an industrialized process of individual ZnO nanostructures applied in gas sensors, a simple, inexpensive, and safe synthesis process is required. Here, nanostructured ZnO films were grown by a pulsed laser deposition technique under different oxygen pressures. Scanning electron microscopy images show nanopores, nanotips, and nanoparticles are obtained and energy dispersive X-ray spectroscopy data indicate oxygen concentration of the synthesized samples increases monotonously with oxygen pressure. The sensor based on ZnO with high oxygen concentration has high sensitivity, rapid response (9 s) and recovery (80 s) behavior to 500 ppm hydrogen below 150 °C. Experimental data indicate that high oxygen concentration effectively improves the sensing properties of nanostructured ZnO.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond photoelectron point projection microscope

By utilizing a nanometer ultrafast electron source in a point projection microscope we demonstrate that images of nanoparticles with spatial resolutions of the order of 100 nanometers can be obtained. The duration of the emission process of the photoemitted electrons used to make images is shown to be of the order of 100 fs using an autocorrelation technique. The compact geometry of this photoelectron point projection microscope does not preclude its use as a simple ultrafast electron microscope, and we use simple analytic models to estimate temporal resolutions that can be expected when using it as a pump-probe ultrafast electron microscope. These models show a significant increase in temporal resolution when comparing to ultrafast electron microscopes based on conventional designs. We also model the microscopes spectroscopic abilities to capture ultrafast phenomena such as the photon induced near field effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗