Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target setting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Subintimal Angioplasty of Long Chronic Total Femoropopliteal Occlusions: Long-Term Outcomes, Predictors of Angiographic Restenosis, and Role of Stenting

Purpose: The purpose of this article is to report the results of a prospective single-center study analyzing the long-term clinical and angiographic outcomes of subintimal angioplasty (SIA) for the treatment of chronic total occlusions (CTOs) of the femoropopliteal artery. Materials and Methods: Patients with severe intermittent claudication or critical limb ischemia (CLI) were enrolled in the study. All lesions were treated with SIA and provisional stenting. Primary end points were technical success, patient survival, limb salvage, lesion primary patency, angiographic binary restenosis (>50%), and target lesion revascularization (TLR). Regular clinical and angiographic follow-up was set at 6 and 12 months and yearly thereafter. Study end points were calculated with life-table survival analysis. Proportional-hazards regression analysis with a Cox-model was applied to adjust for confounding factors of heterogeneity. Results: Between May 2004 and July 2009, 98 patients (105 limbs, patient age 69.3 {+-} 9.9 years) were included in the study. Technical success rate was 91.4% with a lesion length of 121 {+-} 77 mm. Limb-salvage and survival rates were 88.7% and 84.1% at 3 years, respectively. After 12, 24, and 36 months, primary patency was 80.1%, 42.3%, and 29.0%, angiographic binary restenosis was 37.2%, 68.6%, and 80.0%, and TLR was 84.8%, 73.0%, and 64.5%, respectively. CLI was the only adverse predictor for decreased primary patency (hazard ratio [HR] 0.36; 95% confidence interval [CI] 0.16-0.80, p = 0.012), whereas significantly less restenosis was detected after spot stenting of the entry and/or re-entry site (HR 0.31; 95% CI 0.10-0.89, p = 0.01 and HR 0.20; 95% CI 0.07-0.56, p = 0.002, respectively). Conclusions: Subintimal angioplasty is a safe and effective revascularization technique for the treatment of CTOs of the femoropopliteal artery. Provisional stenting may have a role at the subintimal entry or true lumen re-entry site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Therapeutic Intervention Using a Smad7-Based Tat Protein to Treat Radiation-Induced Oral Mucositis

Recent studies reported therapeutic effects of Smad7 on oral mucositis in mice without compromising radiation therapy–induced cancer cell killing in neighboring oral cancer. This study aims to assess whether a Smad7-based biologic can treat oral mucositis in a clinically relevant setting by establishing an oral mucositis model in dogs and analyzing molecular targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multiplexed bacterial two-hybrid for rapid characterization of protein–protein interactions and iterative protein design

Protein-protein interactions (PPIs) are crucial for biological functions and have applications ranging from drug design to synthetic cell circuits. Coiled-coils have been used as a model to study the sequence determinants of specificity. However, building well-behaved sets of orthogonal pairs of coiled-coils remains challenging due to inaccurate predictions of orthogonality and difficulties in testing at scale. To address this, we develop the next-generation bacterial two-hybrid (NGB2H) method, which allows for the rapid exploration of interactions of programmed protein libraries in a quantitative and scalable way using next-generation sequencing readout. We design, build, and test large sets of orthogonal synthetic coiled-coils, assayed over 8,000 PPIs, and used the dataset to train a more accurate coiled-coil scoring algorithm (iCipa). After characterizing nearly 18,000 new PPIs, we identify to the best of our knowledge the largest set of orthogonal coiled-coils to date, with fifteen on-target interactions. Our approach provides a powerful tool for the design of orthogonal PPIs.

59 BASIC BIOLOGICAL SCIENCES↗

Inverse design of photonic surfaces via multi fidelity ensemble framework and femtosecond laser processing

We demonstrate a multi-fidelity (MF) machine learning ensemble framework for the inverse design of photonic surfaces, trained on a dataset of 11,759 samples that we fabricate using high throughput femtosecond laser processing. The MF ensemble combines an initial low fidelity model for generating design solutions, with a high fidelity model that refines these solutions through local optimization. The combined MF ensemble can generate multiple disparate sets of laser-processing parameters that can each produce the same target input spectral emissivity with high accuracy (root mean squared errors < 2%). SHapley Additive exPlanations analysis shows transparent model interpretability of the complex relationship between laser parameters and spectral emissivity. Finally, the MF ensemble is experimentally validated by fabricating and evaluating photonic surface designs that it generates for improved efficiency energy harvesting devices. Our approach provides a powerful tool for advancing the inverse design of photonic surfaces in energy harvesting applications.

97 MATHEMATICS AND COMPUTING↗

Stochastic optimization of a uranium oxide reaction mechanism using plasma flow reactor measurements

Abstract In this work, a coupled Monte Carlo Genetic Algorithm (MCGA) approach is used to optimize a gas phase uranium oxide reaction mechanism based on plasma flow reactor (PFR) measurements. The PFR produces a steady Ar plasma containing U, O, H, and N species with high temperature regions (3000–5000 K) relevant to observing UO formation via optical emission spectroscopy. A global kinetic treatment is used to model the chemical evolution in the PFR and to produce synthetic emission signals for direct comparison with experiments. The parameter space of a uranium oxide reaction mechanism is then explored via Monte Carlo sampling using objective functions to quantify the model-experiment agreement. The Monte Carlo results are subsequently refined using a genetic algorithm to obtain an experimentally corroborated set of reaction pathways and rate coefficients. Out of 12 reaction channels targeted for optimization, four channels are found to be well constrained across all optimization runs while another three channels are constrained in select cases. The optimized channels highlight the importance of the OH radical in oxidizing uranium in the PFR. This study comprises a first step toward producing a comprehensive experimentally validated reaction mechanism for gas phase uranium molecular species formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predictive process simulation of cryogenic implants for leading edge transistor design

Two cryogenic implant TCAD-modules have been developed: (i) A continuum-based compact model targeted towards a TCAD production environment calibrated against an extensive data-set for all common dopants. Ion-specific calibration parameters related to damage generation and dynamic annealing were used and resulted in excellent fits to the calibration data-set. (ii) A Kinetic Monte Carlo (kMC) model including the full time dependence of ion-exposure that a particular spot on the wafer experiences, as well as the resulting temperature vs. time profile of this spot. It was calibrated by adjusting damage generation and dynamic annealing parameters. The kMC simulations clearly demonstrate the importance of the time-structure of the beam for the amorphization process: Assuming an average dose-rate does not capture all of the physics and may lead to incorrect conclusions. The model enables optimization of the amorphization process through tool parameters such as scan speed or beam height.

36 MATERIALS SCIENCE↗

The kinetics of SARS-CoV-2 infection based on a human challenge study

Studying the early events that occur after viral infection in humans is difficult unless one intentionally infects volunteers in a human challenge study. Here, we use data about severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in such a study in combination with mathematical modeling to gain insights into the relationship between the amount of virus in the upper respiratory tract and the immune response it generates. We propose a set of dynamic models of increasing complexity to dissect the roles of target cell limitation, innate immunity, and adaptive immunity in determining the observed viral kinetics. We introduce an approach for modeling the effect of humoral immunity that describes a decline in infectious virus after immune activation. We fit our models to viral load and infectious titer data from all the untreated infected participants in the study simultaneously. We found that a power-law with a power h < 1 describes the relationship between infectious virus and viral load. Viral replication at the early stage of infection is rapid, with a doubling time of ~2 h for viral RNA and ~3 h for infectious virus. We estimate that adaptive immunity is initiated ~7 to 10 d postinfection and appears to contribute to a multiphasic viral decline experienced by some participants; the viral rebound experienced by other participants is consistent with a decline in the interferon response. Altogether, we quantified the kinetics of SARS-CoV-2 infection, shedding light on the early dynamics of the virus and the potential role of innate and adaptive immunity in promoting viral decline during infection.

59 BASIC BIOLOGICAL SCIENCES↗

Gauge issues in extended gravity and f(R) cosmology

We consider issues related to the conformal mapping between the Einstein and Jordan frames in f(R) cosmology. We consider the impact of the conformal transformation on the gauge of a perturbed system and show that unless the system is written in a restricted set of gauges the mapping could produce an inconsistent result in the target frame. Newtonian gauge lies within the restricted group but synchronous gauge does not. If this is not treated carefully it could in principle contaminate numerical calculations.

79 ASTRONOMY AND ASTROPHYSICS↗

Target of 1 Rapamycin kinase is a positive regulator of plant fatty acid 2 and lipid synthesis

In eukaryotes, Target of Rapamycin (TOR), a conserved protein sensor kinase, integrates a diverse set of environmental cues, including growth factor signals, energy availability, and nutritional status, to direct cell growth. In plants, TOR is activated by light and sugars and regulates a wide range of cellular processes, including protein synthesis and metabolism. Fatty acid synthesis is key to membrane biogenesis that in turn, is required for cell growth. To elucidate the primary regulatory role(s) of TOR in lipid metabolism, we followed fatty acid and lipid changes in plants with altered TOR protein levels or activity for short durations, using Nicotiana benthamiana leaves, Arabidopsis seedlings and Brassica napus cell suspension cultures. Transient expression of TOR significantly elevated the levels of total fatty acids in Nicotiana benthamiana leaves, while treatment of Arabidopsis seedlings with Torin 2, a TOR specific inhibitor, for one day, caused significant reductions in fatty acids and membrane lipids. Similarly, incubating oil-producing Brassica napus suspension culture cells with Torin 2 for eight hours led to significant decreases in the levels of TFA and TAG. Taken together the results from three independent systems presented here establishes that TOR positively regulates lipid synthesis in plants, consistent with its role in animals. Furthermore, RNA-seq analysis of Torin 2-treated Arabidopsis seedlings showed that TOR promotes the upregulation of a number of genes involved in de novo fatty acid synthesis while downregulating genes involved in lipid turnover, which we propose as a mechanistic explanation for its promotion of lipid synthesis and accumulation.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 2, Methods and Dose Calculations

This paper is part two of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Assumptions about equilibrium with long-lived parents are made for the 28 other radionuclides in these series lacking data. This paper describes the methods developed to group the collected data into source regions described in the Radiation Dose Assessment Resource (RADAR) dosimetric methodology. Methods for converting the various units of data published over 50 years into a standard form are developed and described. Often, meaningful values of uncertainty of measurements were not published so that variability in data sets is confounded with measurement uncertainty. A description of the methods developed to estimate variability is included in this paper. The data described in part one are grouped by gender and age to match the RADAR dosimetric phantoms. Within these phantoms, concentration values are grouped into source tissue regions by radionuclide, and they are imputed for source regions lacking tissue data. Radionuclide concentrations are then imputed for other phantoms’ source regions with missing concentration values, and the uncertainties of the imputed values are increased. The content concentrations of hollow organs are calculated, and activities are apportioned to the bone source regions using assumptions about each radionuclide’s bone-seeking behavior. The data sets are then ready to be used to estimate equivalent doses to target tissues from these source regions. The target tissues are then mapped to lists of tissues with International Commission on Radiation Protection (ICRP) tissue weighting factors, or they are mapped to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue weighting factors recommended in 1977, 1990, and 2007, are calculated from tissue and organ equivalent doses.

59 BASIC BIOLOGICAL SCIENCES↗

Interpretable AI forecasting for numerical relativity waveforms of quasicircular, spinning, nonprecessing binary black hole mergers

We present a deep-learning artificial intelligence model (AI) that is capable of learning and forecasting the late-inspiral, merger and ringdown of numerical relativity waveforms that describe quasicircular, spinning, nonprecessing binary black hole mergers. We used the NRHybSur3dq8 surrogate model to produce train, validation and test sets of ℓ = |m| = 2 waveforms that cover the parameter space of binary black hole mergers with mass ratios q ≤ 8 and individual spins |s$^{z}_ {(1,2)}$| ≤ 0.8. These waveforms cover the time range t ∊ [-5000 M, 130 M], where t = 0M marks the merger event, defined as the maximum value of the waveform amplitude. We harnessed the ThetaGPU supercomputer at the Argonne Leadership Computing Facility to train our AI model using a training set of 1.5 million waveforms. We used 16 NVIDIA DGX A100 nodes, each consisting of 8 NVIDIA A100 Tensor Core GPUs and 2 AMD Rome CPUs, to fully train our model within 3.5 h. Our findings show that artificial intelligence can accurately forecast the dynamical evolution of numerical relativity waveforms in the time range t ∊ [-100 M, 130 M]. Sampling a test set of 190,000 waveforms, we find that the average overlap between target and predicted waveforms is ≳99% over the entire parameter space under consideration. We also combined scientific visualization and accelerated computing to identify what components of our model take in knowledge from the early and late-time waveform evolution to accurately forecast the latter part of numerical relativity waveforms. This work aims to accelerate the creation of scalable, computationally efficient and interpretable artificial intelligence models for gravitational wave astrophysics

79 ASTRONOMY AND ASTROPHYSICS↗

Search for flavor-changing neutral-current couplings between the top quark and the Z boson with proton-proton collisions at s = 13 TeV with the ATLAS detector

A search for flavor-changing neutral-current couplings between a top quark, an up or charm quark, and a $Z$ boson is presented, using proton-proton collision data at $\sqrt{s}$ = 13 TeV collected by the ATLAS detector at the Large Hadron Collider. The analyzed data set corresponds to an integrated luminosity of 139 fb -1 . The search targets both single-top-quark events produced as $gq$ → $tZ$ (with $q$ = $u, c$) and top-quark-pair events, with one top quark decaying through the $t$ → $Zq$ channel. The analysis considers events with three leptons (electrons or muons), a $b$-tagged jet, possible additional jets, and missing transverse momentum. The data are found to be consistent with the background-only hypothesis and 95% confidence-level limits on the $t$ → $Zq$ branching ratios, assuming only tensor operators of the Standard Model effective field theory framework contribute to the $tZq$ vertices. These are 6.2 x 10 -5 (13 x 10 -5 ) for $t$ → $Zu$ ($t$ → $Zc$) for a left-handed $tZq$ coupling, and 6.6 x 10 -5 (12 x 10 -5 ) in the case of a right-handed coupling. These results are interpreted as 95% CL upper limits on the strength of the corresponding couplings, yielding limits for |${C}^{(13)*}_{uW}$| and |${C}^{(13)*}_{uB}$| (|${C}^{(31)}_{uW}$| and |${C}^{(31)}_{uB}$|) of 0.15 (0.16), and limits for |${C}^{(23)*}_{uW}$| and |${C}^{(23)*}_{uB}$| (|${C}^{(32)}_{uW}$| and |${C}^{(32)}_{uB}$|) of 0.22 (0.21), assuming a new-physics energy scale Λ NP of 1 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Centroid and Envelope Dynamics of High-Intensity Charged-Particle Beams in an External Focusing Lattice and Oscillating Wobbler

The centroid and envelope dynamics of a high-intensity charged-particle beam are investigated as a beam smoothing technique to achieve uniform illumination over a suitably chosen region of the target for applications to ion-beam-driven high energy density physics and heavy ion fusion. The motion of the beam centroid projected onto the target follows a smooth pattern to achieve the desired illumination, for improved stability properties during the beam-target interaction. The centroid dynamics is controlled by an oscillating 'wobbler', a set of electrically biased plates driven by rf voltage.

43 PARTICLE ACCELERATORS↗

Global Microscopic Description of Nucleon-Nucleus Scattering with Quantified Uncertainties

We develop for the first time a microscopic global nucleon-nucleus optical potential with quantified uncertainties suitable for analyzing nuclear reaction experiments at next-generation rare-isotope beam facilities. Within the improved local density approximation and without any adjustable parameters, we begin by computing proton-nucleus and neutron-nucleus optical potentials from a set of five nuclear forces from chiral effective field theory for 1800 target nuclei in the mass range 12 ≤ A ≤ 242 for energies between 0 MeV < E ≲ 150 MeV. We then parameterize a global optical potential for each chiral force that depends smoothly on the projectile energy as well as the target nucleus mass number and isospin asymmetry. Uncertainty bands for elastic scattering observables are generated from a full covariance analysis of the parameters entering in the description of our global optical potential and benchmarked against existing experimental data for stable target nuclei. Since our approach is purely microscopic, we anticipate a similar quality of the model for nucleon scattering on unstable isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams

Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were removed from the beam path, leaving only the exit window. With the x-ray target and flattener out of the beam, uncertainties in physical characteristics and relative position of the target and flattening filter, and in spot size, did not contribute to uncertainty in the energy. Beam current was lowered to reduce recombination effects. The measured dose distributions were compared with Monte Carlo simulation of the electron beam through the treatment head to extract the electron source characteristics. For the nominal 6 and 18 MV x-ray beams, the energies were 6.51{+-}0.15 and 13.9{+-}0.2 MeV, respectively, with the uncertainties resulting from uncertainties in the detector position in the measurement and in the stopping power in the simulations. Gaussian spectral distributions were used, with full widths at half maximum ranging from 20{+-}4% at 6 MV to 13{+-}4% at 18 MV required to match the fall-off portion of the percent-depth ionization curve. Profiles at the depth of maximum dose from simulations that used the manufacturer-specified exit window geometry and no beam divergence were 2-3 cm narrower than measured profiles. Two simulation configurations yielding the measured profile width were the manufacturer-specified exit window thickness with electron source divergences of 3.3 degree sign at 6 MV and 1.8 deg. at 18 MV and an exit window 40% thicker than the manufacturer's specification with no beam divergence. With the x-ray target in place (and no flattener), comparison of measured to simulated profiles sets upper limits on the electron source divergences of 0.2 deg. at 6 MV and 0.1 deg. at 18 MV. A method of determining source characteristics without mechanical modification of the treatment head, and therefore feasible in clinics, is presented. The energies and spectral widths determined using this method agree with those determined with only the exit window in the beam path.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-544: Microscopic Dose Enhancement of Gold Nanoparticles in Water for Proton Therapy: A Simulation Study

Purpose: To quantify the microscopic dose and linear energy transfer (LET) enhancement of gold nanoparticles (GNPs) in water for proton therapy. Methods: The GEANT4 toolkit (version 10) with low energy electromagnetic classes was used to create a series of simulations where three radii (r=5, 20, 100 nm) of gold nanoparticles (GNPs) were irradiated with 5 × 106 80 MeV protons. A cubic detector (10 × 10 × 10 um, divided in 25 × 25 × 25 voxels) were placed in a water phantom where the GNP rests in the center. The size of incident proton beam was set to be same as the GNPs and perpendicularly aiming to the target. Dose deposited to each voxel were recorded to calculate the overall deposited dose and the dose-averaged LET. The emitted secondary electron spectra were also collected in a spherical customized scorer (radius = 150 nm). Results: The average dose from a single GNP in a cubic water phantom was increased by 0.12 %, 1.12% and 2.3% and the mean dose-averaged LET was increased by 5.87% and 27.67% and 0.31% for GNP radius of 5 nm, 20 nm and 100 nm, respectively. Conclusion: The dose enhancement effect from the presence of a single GNP was qualified in a water phantom. A significant increase in the mean dose-averaged LET was found for 20 nm GNP.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-206-03: Metal Artifact Reduction in X-Ray Computed Tomography Based On Local Anatomical Similarity

Purpose: Metal implants such as orthopedic hardware and dental fillings cause severe bright and dark streaking in reconstructed CT images. These artifacts decrease image contrast and degrade HU accuracy, leading to inaccuracies in target delineation and dose calculation. Additionally, such artifacts negatively impact patient set-up in image guided radiation therapy (IGRT). In this work, we propose a novel method for metal artifact reduction which utilizes the anatomical similarity between neighboring CT slices. Methods: Neighboring CT slices show similar anatomy. Based on this anatomical similarity, the proposed method replaces corrupted CT pixels with pixels from adjacent, artifact-free slices. A gamma map, which is the weighted summation of relative HU error and distance error, is calculated for each pixel in the artifact-corrupted CT image. The minimum value in each pixel’s gamma map is used to identify a pixel from the adjacent CT slice to replace the corresponding artifact-corrupted pixel. This replacement only occurs if the minimum value in a particular pixel’s gamma map is larger than a threshold. The proposed method was evaluated with clinical images. Results: Highly attenuating dental fillings and hip implants cause severe streaking artifacts on CT images. The proposed method eliminates the dark and bright streaking and improves the implant delineation and visibility. In particular, the image non-uniformity in the central region of interest was reduced from 1.88 and 1.01 to 0.28 and 0.35, respectively. Further, the mean CT HU error was reduced from 328 HU and 460 HU to 60 HU and 36 HU, respectively. Conclusions: The proposed metal artifact reduction method replaces corrupted image pixels with pixels from neighboring slices that are free of metal artifacts. This method proved capable of suppressing streaking artifacts, improving HU accuracy and image detectability.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-09: Proton Minibeam Radiation Therapy Increases Normal Tissue Resistance

Purpose: The dose tolerances of normal tissues continue being the main limitation in radiotherapy. To overcome it, we recently proposed a novel concept: proton minibeam radiation therapy (pMBRT) [1]. It allies the physical advantages of protons with the normal tissue preservation observed when irradiated with submillimetric spatially fractionated beams (minibeam radiation therapy) [2]. The dose distributions are such that the tumor receives a homogeneous dose distribution, while normal tissues benefit from the spatial fractionation of the dose. The objective of our work was to implement this promising technique at a clinical center (Proton therapy center in Orsay) in order to evaluate the potential gain in tissue sparing. Methods: Dose distributions were measured by means of gafchromic films and a PTW microdiamond detector (60019). Once the dosimetry was established, the whole brain of 7 weeks old male Fischer 344 rats was irradiated. Half of the animals received conventional seamless proton irradiation (25 Gy in one fraction). The other rats were irradiated with pMBRT (58 Gy peak dose in one fraction). The average dose deposited in the same targeted volume was in both cases 25 Gy. Results: The first complete set of dosimetric data in such small proton field sizes was obtained [3]. Rats treated with conventional proton irradiation exhibited severe moist desquamation and permanent epilation afterwards. The minibeam group, on the other hand, exhibited no skin damage and no clinical symptoms. MRI imaging and histological analysis are planned at 6 months after irradiation. Conclusion: Our preliminary results indicate that pMBRT leads to an increase in tissue resistance. This can open the door to an efficient treatment of very radioresistant tumours. [1] Prezado et al. Med. Phys. 40, 031712, 1–8 (2013).[2] Prezado et al., Rad. Research. 184, 314-21 (2015). [3] Peucelle et al., Med. Phys. 42 7108-13 (2015).

60 APPLIED LIFE SCIENCES↗