Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Accretion-Driven Sources in Spatially Resolved Lyα Emitters

Lyα emission is a standard tracer of starburst galaxies at high redshift. However, a number of local Lyα emitters (LAEs) are X-ray sources, suggesting a possible origin of Lyα photons other than young, hot stars, and which may be active at much later ages relative to the parent starburst. Resolved, nearby LAEs offer the opportunity to discriminate between diffuse X-ray emission arising from supernova-heated gas, high-mass X-ray binaries (HMXBs), or low-luminosity active galactic nuclei (LLAGN). We examine archival X-ray imaging from Chandra and XMM-Newton for 11 galaxies with spatially resolved Lyα imaging to determine the luminosity, morphology, and spectral hardness of the X-ray sources. The data are consistent with 9 of the 12, bright Lyα sources being driven by luminous, >1040 erg s-1 X-ray sources. Half of the eight Chandra sources are unresolved. The data suggest that nuclear activity, whether from LLAGN or nuclear starbursts, may play an important role in Lyα emission. Our results also suggest a significant link between Lyα emission and HMXBs, ultraluminous X-ray sources, and/or LLAGN, which would imply that Lyα may be generated over timescales 1–2 orders of magnitude longer than produced by photoionization from OB stars. This highlights a critical need to quantify the relative contributions of different sources across cosmic time, to interpret Lyα observations and the resulting properties of distant galaxies.

Benjamin Dittenber↗

2SXPS: An Improved and Expanded Swift X-Ray Telescope Point-source Catalog

We present the 2SXPS (Swift-XRT Point Source) catalog, containing 206,335 point sources detected by the Swift X-ray Telescope (XRT) in the 0.3–10 keV energy range. This catalog represents a significant improvement over 1SXPS, with double the sky coverage (now 3790 deg2), and several significant developments in source detection and classification. In particular, we present for the first time techniques to model the effect of stray light—significantly reducing the number of spurious sources detected. These techniques will be very important for future, large effective area X-ray missions, such as the forthcoming Athena X-ray observatory. We also present a new model of the XRT point-spread function and a method for correctly localizing and characterizing piled-up sources. We provide light curves—in four energy bands, two hardness ratios, and two binning timescales—for every source, and from these deduce that over 80,000 of the sources in 2SXPS are variable in at least one band or hardness ratio. The catalog data can be queried or downloaded via a web interface at https://www.swift.ac.uk/2SXPS, via HEASARC, or in Vizier (IX/58).

Catalogs↗

Multiplanar Synthetic Arrays and Their Application to Full-Scale Landing Gear Noise Source Identification

Identification and quantification of noise sources generated by the landing gears of large civil transports are critical for the development of viable abatement technologies that can be applied locally to affect solely the source regions. Leveraging validated computational data sets obtained from airframe noise simulations of a full-scale B777-300ER aircraft, a frame-work based on multiplanar synthetic arrays was developed to examine landing gear sources. The position of the arrays relative to the aircraft nose or main landing gears, the number of microphones in each array, and their distribution pattern were judiciously selected to provide adequate spatial resolution of the sources in the primary flyover, sideline, and upstream directions while maintaining reasonable signal-to-noise ratio and beamwidth over a wide frequency range. Overall, seven synthetic arrays with 800 microphones each, for a total of 5,600 microphones, were used in the framework. Fully synchronous synthetic pressure records at each microphone location were obtained from the simulated data sets via a Ffowcs-Williams and Hawkings integral approach, with flow quantities on a permeable data surface enclosing the source regions used as input. Various applications of synthetic multiplanar arrays to acoustic data analysis are presented; the advantages of the framework in properly resolving and identifying the B777 landing gear sources is demonstrated by comparing three-dimensional source distribution maps with those obtained from a synthetic version of the ground-based microphone array used during flight tests of the same aircraft.

airframe noise↗

Titanium oxidation state and coordination in the lunar high-titanium glass source mantle

XANES and EXAFS spectra from synthetic HiTi lunar glasses determine coordination of Ti in the HiTi source region. The amount of Ti{sup 3+} present affects the olivine-opx equilibrium, and the total amount of Ti{sup 3+} present requires a pyx bearing source. Lunar high-titanium (HiTi) ultramafic glasses provide us with evidence of the mantle processes that led to the melting of the lunar magma ocean cumulates nearly one billion years after the magma ocean solidified. Constraints on the depth, temperature and melting processes that formed the HiTi glasses are crucial for understanding the melting history of LMO products. The Apollo 17 orange glass (A17O) and Apollo 15 red glass (A15R) represent two of the HiTi compositions in the spectrum of pristine ultramafic glasses returned from the moon. The difference between these two compositions is that the A15R contains {approx}40% more TiO{sub 2} than the A17O. The low f{sub O2} of the ultramafic glass source regions allows for a certain amount of Ti{sup 3+} in the source mineralogy; however the amount of Ti{sup 3+} in the source and the host mineral for this element remain relatively unconstrained. In addition to the unknown mineralogy of the source region, the high amount of TiO*{sub 2} and FeO* in the HiTi magmas makes the phase relations extremely sensitive to changes in the oxidation state of the source region. We have previously investigated the oxidation state effect on the olivine-orthopyroxene multiple saturations points of the A15R and A17O and shown that the magnitude of the effect is proportional to the amount of Ti in the system. X-ray absorption near-edge spectroscopy (XANES) and extended X-ray absorption fine-structure (EXAFS) measurements have been made on minerals and glasses in experiments on synthetic analogues to the A17O and A15R. Our results show that Ti{sup 3+} concentration does indeed affect the multiple saturation points, and is an important constituent in the lunar interior.

79 ASTRONOMY AND ASTROPHYSICS↗

GAMMA DOSE RATE NEAR A NEW (252)Cf BRACHYTHERAPY SOURCE

A new generation of medical grade (252)Cf sources was developed in 2002 at the Oak Ridge National Laboratory. The combination of small size and large activity of (252)Cf makes the new source suitable to be used with the conventional high-dose-rate remote afterloading system for interstitial brachytherapy. A recent in-water calibration experiment showed that the measured gamma dose rates near the new source are slightly greater than the neutron dose rates, contradicting the well established neutron-to-gamma dose ratio of approximately 2:1 at locations near a (252)Cf brachytherapy source. Specifically, the MCNP-predicted gamma dose rate is a factor of two lower than the measured gamma dose rate at the distance of I cm, and the differences between the two results gradually diminish at distances farther away from the source. To resolve this discrepancy, we updated the source gamma spectrum by including in the ORIGEN-S data library the experimentally measured (252)Cf prompt gamma spectrum as well as the true (252)Cf spontaneous fission yield data to explicitly model delayed gamma emissions from fission products. We also investigated the bremsstrahlung X-rays produced by the beta particles emitted from fission product decays. The results show that the discrepancy of gamma dose rates is mainly caused by the omission of the bremsstrahlung X-rays in the MCNP runs. By including the bremsstrahlung X-rays, the MCNP results show that the gamma dose rates near a new (252)Cf source agree well with the measured results and that the gamma dose rates are indeed greater than the neutron dose rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of a Position-Sensitive Multi-Anode Photomultiplier Tube for Finding Gamma-Ray Source Direction

In an urban environment where gamma-ray background counts vary rapidly, it is important to determine the angle (with respect to the detector system) of a discrete gamma-ray–emitting source for localization purposes. We have recently developed a handheld gamma-ray detection system that provides gamma-ray energy spectral data and angular position of the target source. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. The objectives of this project were to design and build a prototype, light-weight, hand-held, gamma-ray spectrometer with directional sensitivity. It is important for first responders in a radiological emergency to have an easy-to-use gamma spectrometric detection system that determines the incident gamma-ray energy along with the relative angular position of a point-like radioactive source in a near-field measurement (≤3 meters from the source). The technical challenge of this project, driven by search scenarios for monitoring crowds in a national special security events was to determine the relative angle of a gamma-ray–emitting source (50 μCi strong) at a distance of 3 meters from the detector in 3 minutes. We designed and built small, portable, light-weight directional gamma energy spectrometers using a position-sensitive multi-anode photomultiplier. All of three spectrometers showed remarkable (ΔΘ = ± 2°) sensitivity to relative angular position of the source in near-field laboratory measurements.

position-sensitive photomultiplier tube (PMT), mul↗

Identification of mixed sources with an organic scintillator-based radiation portal monitor

We have developed radionuclide identification algorithms for radiation portal monitor applications. One algorithm uses a spectral angle mapper to match the power spectral density of modified cumulative distribution functions of measured pulse height distributions to reference spectra, while the others rely on the decomposition of the observed spectrum as a linear mixture of known radionuclide spectra. Three algorithms were then tested for their ability to perform on-the-fly radionuclide identification on datasets acquired with a liquid organic scintillator-based pedestrian radiation portal monitor on moving special nuclear material and industrial radiological sources, as well as common medical isotopes. We quantified and compared the relative efficacies of the algorithms considered using F-score analysis. Measured radiation sources included 51 g of highly enriched uranium, 6.6 g of weapons grade plutonium, 241 Am, 133 Ba, 57 Co and 137 Cs sources with activities of several hundred kBq, as well as 260 kBq liquid solution samples of the medical isotopes 99m Tc, 111 In, 67 Ga, 123 I, 131 I, and 201 Tl. We achieved 100% positive identification, for three-second measurements of single sources moving at a source-transit speed of 1.2 m/s. For mixed sources with strongest and weakest sources having no more than a 5:1 ratio of detected counts, encouraging positive identification results were achieved with the un-mixing algorithms. Current radiation portal monitor designs suffer from a high incidence rate of nuisance radiation alarms caused in radiation portal monitor primary screenings by recent nuclear medicine patients and cargo containing large amounts of naturally occurring radioactive materials. Integrating reliable on-the-fly radionuclide identification into the radiation portal monitors could lower the number of nuisance alarms requiring time-consuming secondary inspections.

47 OTHER INSTRUMENTATION↗

Heuristic based analytics for gas leak source identification

Heuristic-based techniques for gas leak source identification are provided. In one aspect, a method for identifying a location of a gas leak source includes: obtaining gas sensor data and wind data synchronously from a gas leak detection system having a network of interconnected motes comprising gas sensors and wind sensors, with the gas sensors arranged around possible gas leak sources in a given area of interest; identifying the location of the gas leak source using the gas sensor data and wind data; and determining a magnitude of gas leak from the gas leak source using the location of the gas leak source and a distance d between the location of the gas leak source and a select one of the gas sensors from which the gas sensor data was obtained. A gas leak detection system is also provided.

03 NATURAL GAS↗

Source identification by non-negative matrix factorization combined with semi-supervised clustering

Machine-learning methods and apparatus are provided to solve blind source separation problems with an unknown number of sources and having a signal propagation model with features such as wave-like propagation, medium-dependent velocity, attenuation, diffusion, and/or advection, between sources and sensors. In exemplary embodiments, multiple trials of non-negative matrix factorization are performed for a fixed number of sources, with selection criteria applied to determine successful trials. A semi-supervised clustering procedure is applied to trial results, and the clustering results are evaluated for robustness using measures for reconstruction quality and cluster separation. The number of sources is determined by comparing these measures for different trial numbers of sources. Source locations and parameters of the signal propagation model can also be determined. Disclosed methods are applicable to a wide range of spatial problems including chemical dispersal, pressure transients, and electromagnetic signals, and also to non-spatial problems such as cancer mutation.

97 MATHEMATICS AND COMPUTING↗

Data Release Report for the Source Physics Experiment Phase II: Dry Alluvium Geology Experiments (DAG-1 through DAG-4), Nevada National Security Site

The Dry Alluvium Geology (DAG) project was Phase II of the Source Physics Experiment and consisted of a series of four chemical explosive tests conducted in the same source hole on the Nevada National Security Site. This hole is located at 37.1146°N and -116.0693°W, with a surface elevation of 1,285.2 meters (m) (4,216.5 feet [ft]) above sea level. The first test (DAG-1) was conducted on July 20, 2018, at 16:51:52.67838 Coordinated Universal Time (UTC). The explosive source for DAG-1 was nitromethane initiated by a small plastic-bonded explosive (PBX) charge, detonated at the depth of 385.0 m (1,263.2 ft) below ground surface. DAG-1 had a trinitrotoluene (TNT) equivalent yield of 0.908 metric tons (2,002 pounds [lbs]). DAG-2 was conducted on December 19, 2018, at 18:45:56.92115 UTC. This test was the largest in the series, with a TNT equivalent yield of 50.997 metric tons (112,429 lbs). The explosive source for DAG-2 was nitromethane initiated by a small PBX charge, detonated at the depth of 299.8 m (983.6 ft) below ground surface. DAG-3 was conducted on April 27, 2019, at 15:49:01.84183 UTC. The explosive source for this test was nitromethane initiated by a small PBX charge, detonated at the depth of 149.9 m (492.0 ft) below ground surface. DAG-3 had a TNT equivalent yield of 0.908 metric tons (2,002 lbs). The final DAG test (DAG-4) was conducted on June 22, 2019, at 21:06:19.87632 UTC. The explosive source for DAG-4 was nitromethane initiated by a small PBX charge, detonated at the depth of 51.6 m (169.3 ft) below ground surface. DAG-4 had a TNT equivalent yield of 10.357 metric tons (22,833 lbs). The four tests were recorded by an extensive set of instrumentation that included sensors both at near-field (less than 200 m) and far-field (200 m or greater) distances. The near-field instruments consisted of three-component (3C) accelerometers installed at various depths ranging from 51.6 to 385 m (169.3 to 1,263.1 ft) below ground surface in boreholes positioned around the source hole, and arrays of single-component and 3C accelerometers on the surface. The far-field network comprised a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and 3C accelerometers at distances of 200 m to 400 kilometers. In addition, the DAG-2, DAG-3, and DAG-4 explosions were recorded by a temporary array of 496 geophones arranged in a densely spaced grid pattern known as “Large N.” This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the four DAG tests and the various types of near-field, far-field, and other data that are available. Assembled data sets are accessible through: Incorporated Research Institutions for Seismology, Data Management Center 1408 NE 45th Street, Suite 201, Seattle, Washington 98105 USA. www.iris.washington.edu

58 GEOSCIENCES↗

Study of Classifiers for U-235 Source Signatures Using Gamma Spectral Measurements

Signatures associated with low-level U-235 sources are studied from a classification analytics perspective, using NaI gamma-ray spectral measurements from detectors located at various distances from the source. Data sets collected at a shielded facility are utilized, wherein the source is introduced via a conduit into a formation of 21 NaI detectors deployed over 6 x 6 meters area in a formation of two concentric circles and one spiral. The activity levels in the spectral regions associated with potential U-235 signatures are estimated as counts at 1 second intervals, and are used as features to train classifiers for detecting the presence of the source. Eight different classifiers are trained and tested using the background and source measurements collected over multiple experimental runs. As expected, the classifier performance improved overall as measurements from the detectors closer to source are used, but also revealed unexpectedly low performance by two detectors that are identically produced and configured as others. Six of eight classifiers have an overall comparable performance, for example, three of them achieved zero training error and 99% detection at 4% false alarm rate for a detector located 1.3 meters away from the source. Also, larger training sets led to improved classification performance across all classifiers, and interestingly, the classifiers with the minimum training error did not necessarily achieve the highest classification performance on test data.

Rao, Nageswara↗

Source identification by non-negative matrix factorization combined with semi-supervised clustering

Machine-learning methods and apparatus are provided to solve blind source separation problems with an unknown number of sources and having a signal propagation model with features such as wave-like propagation, medium-dependent velocity, attenuation, diffusion, and/or advection, between sources and sensors. In exemplary embodiments, multiple trials of non-negative matrix factorization are performed for a fixed number of sources, with selection criteria applied to determine successful trials. A semi-supervised clustering procedure is applied to trial results, and the clustering results are evaluated for robustness using measures for reconstruction quality and cluster separation. The number of sources is determined by comparing these measures for different trial numbers of sources. Source locations and parameters of the signal propagation model can also be determined. Disclosed methods are applicable to a wide range of spatial problems including chemical dispersal, pressure transients, and electromagnetic signals, and also to non-spatial problems such as cancer mutation.

Alexandrov, Boian S.↗

The Impacts of Source Location in Tomographic Gamma Scanning - 17324

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has been equipped to use various collimators and attenuators to assay containers under a wide range of operational conditions. In this paper, we report on experimental work using TGS systems aimed at evaluating the effects of source locations at the limits of volume elements, or voxels, defined in the image reconstruction. These include sources placed at voxel boundaries within a single vertical layer and sources placed in the lowest and highest possible vertical positions within the containers. Building upon previous studies, the accuracy of the TGS system was also assessed by varying the radial position of a point source within a vertical segment. The robustness of the TGS image reconstruction algorithm to location of the sources location was also analyzed as a function of matrix density and gamma-ray energy. Methods to reduce the biases from source location at extreme positions within the container were implemented and tested. The results from this work have been used to better understand the total measurement uncertainty (TMU) and analysis methodology used in TGS systems currently deployed and under development. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reconstruction of Irradiation History of Am-241/Be Startup Sources for Disposal at WIPP - 18644

The National Nuclear Security Administration, Global Material Security (GMS)/ Off-site Source Recovery Program (OSRP) requires an approved final disposition pathway for sealed neutron startup sources with undocumented or questionable irradiation histories. To obtain approval for WIPP disposal, a reliable method is required to determine yields of transmutation, as well as fission and activation products contained within the source at the time of disposal. This paper presents a method to reconstruct the irradiation history of americium beryllium (Am/Be) reactor startup sources using gamma spectroscopy, ORIGEN modeling and the initial composition of the source. Using this method, measured isotopes in the Am/Be startup sources are related to the WIPP disposal requirements. Maximum allowable measurement uncertainties have been quantified and related to uncertainties in the WIPP required isotopes. Characterization calculations and experimental measurements of irradiated Am/Be sources are discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comprehensive Approach to Gamma-Ray Source Identification in the GLAST-LAT Era

Unveiling the nature of a vast number of unidentified sources is the most compelling problem facing today's high-energy (MeV-to-GeV) gamma-ray astronomy. However, unidentified sources are not peculiar to high-energy gamma-ray astronomy, they have been an ever-present phenomenon in astronomy. Indeed, every time a new astronomical window was opened, astronomers found sources they were not able to identify, i.e. to associate with previously known objects. This can happen either because such sources belong to a genuinely new (thus unknown) class or because their positions are not known accurately enough to allow for an unambiguous association between the newly found emitter and a known object. Thus, the lack of identification is frequently ascribed to poor angular resolution. Being unidentified, however, is a 'temporary' status: sooner or later better tools will allow the source identification, i.e. either its classification within a given class of astronomical objects or its recognition as belonging to a new class. Owing to the intrinsic limitations of gamma-ray detection technique, however, the instruments' angular resolution has not yet reached the minimum level required to permit the transition from the unidentified limbo to the paradise of known objects, thus creating a continuing unidentified high-energy gamma-ray source problem. Different approaches towards source identification have been pursued in the past. Here we will review the state of the art as well as the strategies devised for the GLAST era.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fundamental role of the retarded potential in the electrodynamics of superluminal sources: reply to comment

Neither Eq. (6.52) of Jackson [Classical Electrodynamics, 3rd ed. (Wiley, 1999)], or Hannay's derivation of that dquation in the preceding Comment [J. Opt. Soc. Am. A, ... (2009)], are applicable to a source whose distribution pattern moves faster than light in vacuo with nonzero acceleration. It is assumed in Hannay's derivation that the retarded distribution of the density of any moving source would be smooth and differentiable if its rest-frame distribution is. By working out an explicit example of a rotating superluminal source with a bounded and smooth density profile, we show that this assumption is erroneous. The retarded distribution of a rotating source with a moderate superluminal speed is, in general, spread over three disjoint volumes (differing in shape from each other and from the volume occupied by the source in its rest frame) whose boundaries depend on the spacetime position of the observer. Hannay overlooks the fact that the limits of integration in his expression for the retarded potential (which delineate the boundaries of the retarded distribution of the source) are not differentiable functions of the coordinates of the observer at those points on the source boundary that approach the observer, along the radiation direction, with the speed of light at the retarded time. In the superluminal regime, derivatives of the integral representing the retarded potential are well defined only as generalized functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗